• Title/Summary/Keyword: R-test

Search Result 10,536, Processing Time 0.047 seconds

Influence of Filling Density in the Positive Active-material on the Cycle-life Performance of the Tubular Type Gelled Valve Regulated Lead Acid Batteries (튜브식 겔형 납축전지에 있어서 활물질 밀도에 따른 싸이클 수명 특성)

  • Yoon, Youn-Saup;Kim, Byung-Kwan;Lee, Soo;Kim, Kyu-Tea
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.415-418
    • /
    • 1999
  • The characteristics of VRLA (valve regulated Iead-acid) battery with the tubular positive plate and gel type electrolyte were examined as a function of active material filling density. The filling density of positive plate was 3.2 g/mL, 3.4 g/mL, and 3.6 g/mL, respectively. These VRLA batteries were cycled with 100% DOD (depth of discharge) at the $C_5/5$ rate, followed by IU-type recharge with $I_{max}=0.2C_{10}/10$ and a final voltage V=2.40 V/cell. The test was performed in a thermostatic room at $25{\pm}1^{\circ}C$. The result indicated that the initial capacity was independent of active material filling density, i.e., the highest initial capacity was 3.4 g/mL of filling density and the lowest was 3.6 g/mL. On aspect of the cycle-life performance of the VRLA battery, the filling density of 3.6 g/mL was similar to that of 3.4 g/mL in the positive plate, and both were higher than that of 3.2 g/mL. Water-loss and degradation of the VRLA battery were decreased according to an increase of the filling density in the positive plate. The optimum filling density of the active material was 3.4~3.6 g/mL.

  • PDF

Extrusion Process of Barley Flour for Snack Processing (스낵제조를 위한 보리의 압출성형공정)

  • Mok, Chul-Kyoon;Pyler, R.E.;Mcdonald, C.E.;Nam, Young-Jung;Min, Byong-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.429-436
    • /
    • 1984
  • To expand the utility of barley the experiments on the extrusion characteristics of barley flour for snack processing were carried out and the effects of the extrusion conditions on the quality of the extrudates were investigated. The optimum moisture content of barley flour for snack processing was 20%. The moisture content and the density of the extrudates decreased with increasing extrusion temperature and decreasing die size. The die swell ranged from 0.98 to 2.18 according to various extrusion conditions and decreased with increasing temperature above $150^{\circ}C$. The lightness, redness and yellowness increased at higher temperature. The water absorption index and the water solubility index showed their maximum values at $180^{\circ}C$.The gelatinization degree of the extrudates increased with increasing temperature. The fracture fore, Young's modulus and maximum fiber stress decreased, but the deformation to fracture increased, with increasing temperature and decreasing die size. The yield force in puncture test showed lower values at higher temperature. The size and the fraction of the air cells increased with increasing temperature and decreasing die size. The optimum extrusion conditions of barley for snack processing were at the temperature of $180^{\circ}C$, with the die size of 4.5mm when processed at 160 rpm.

  • PDF

Effects of Probiotic Microbes on Growth Performance, Innate Immunity, and Pathogen Sensitivity in Cultured Olive Flounder (Probiotic 기능을 가진 미생물을 함유한 양어용 생균제가 넙치의 성장, 선천성면역 및 항병능에 미치는 영향)

  • Lee, Ji-Hoon;Chae, Young-Sik;Park, Jung-Jin;Choi, Jun-Ho;Kim, Dong-Gun;Park, Kwan Ha
    • Journal of fish pathology
    • /
    • v.30 no.1
    • /
    • pp.41-49
    • /
    • 2017
  • Probiotic principles can be applied in aquaculture for the purpose of growth and immunity stimulation, disease prevention and eventually better production performance. This study was to assess effects of combinations of microbes containing two Bacillus sp., plus one Lactobacillus sp. as the basal preparation (BSL-LAB), and additional Nitrosomonas sp. (nitrifying bacteria consortium, NBS) in olive flounder (Paralichthys olivaceus). The effects examined were growth parameters, hematologic parameters, innate immunity and pathogen challenge test. Fish were assigned to 4 treatments as Control (no probiotics), Group A (Bacillius and Lactobacillus to culture water), Group B (Bacillius and Lactobacillus both in water and feed), Group C (same as Group B with additional Nitrosomonas in feed). Fish were allocated to the above 4 groups, each group being composed of triplicate 30 fish, for a 7-week feeding in the laboratory. Positive effects were observed both in growth and pathogen sensitivity with all three probiotic combinations. Such effects were attributed to improved innate immune functions. This result indicates that the tested probiotic microbes are beneficial to olive flounder aquaculture.

Soft Rot on Peach Caused by Rhizopus oryzae in Korea (Rhizopus oryzae에 의한 복숭아 무름병)

  • Kwon, Jin-Hyeuk;Kang, Dong-Wan;Ha, Jeong-Seok;Kim, Jin-Woo;Kwak, Youn-Sig
    • The Korean Journal of Mycology
    • /
    • v.40 no.1
    • /
    • pp.65-68
    • /
    • 2012
  • In July and August 2011, a disease suspected to be Rhizopus soft rot was observed on peach (Prunus persica var. vulgaris) at the Wholesale Market for Agricultural Products, Jinju, Korea. The first symptom of soft rot on peach is a water-soaked appearance of the affected tissue. The infected parts later disintegrated into a mushy mass of disorganized cells followed by rapid softening of the diseased tissue. The lesion on peach was rapidly softened and rotted, then became brown or dark brown. Optimum temperature for mycelial growth of the causal fungus on PDA was $30^{\circ}C$and growth was still apparent at $37^{\circ}C$Sporangiophores were 6~20 ${\mu}m$ in diameter. Sporangia were globose and 35~200 ${\mu}m$ in size. The color of sporangia was brownish-grey to blackish-grey at maturity. Sporangiospores were sub-globose, brownish- black streaked and 5~10 ${\mu}m$ in size. Columella were globose to sub-globose and 85~120 ${\mu}m$ in size. On the basis of mycological characteristics, pathogenicity test, and molecular identification, the causal fungus was identified as Rhizopus oryzae Went & Prinsen Geerligs. To our knowledge, this is the first report of soft rot caused by R. oryzae on peach in Korea.

The Epidemiologial Study on the Welders' Pneumoconiosis among Shipyard Welders in Pusan Area (부산지역 조선업 용접공들의 진폐증에 관한 역학적 조사연구)

  • Lee, C.U.;Lee, Jong-Tae;Shon, H.S.;Kim, S.C.;Pae, K.T.;Park, H.J.;Kim, Y.W.;Yun, I.G.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.1 s.25
    • /
    • pp.153-161
    • /
    • 1989
  • Authors studied on the prevalence of 94 cases of pneumoconiosis who were found out through the screening test on 1,062 workers engaged in welding process at 36 shipyard in Pusan area from March 1st, 1986 to November 30th, 1986. The result were as follows; 1. Dust concentration was measured $4.49{\pm}0.54mg/m^3$ in the small scale shipyard while it was $6.25{\pm}1.08mg/m^3$ in the large one. 2. The prevalence of welder's lung was 8.9% (male:8.5%, female:12.0%) and this is consist of 4.9% suspected pneumoconiosis and 4.0% pneumoconiosis more than category 1/0. 3. The prevalence was significantly increased according to the duration of dust exposure(p<0.05), and it showed the increasing tendency by the age group. 4. The prevalence was significantly higher in the large scale shipyard than is the small scale one(p<0.01). 5. The type and shape of opacities were 71.4% of p type and 28.6% of q type, however no pneumoconiosis with r type observed in this study. 6. The main subjective symptoms were the sputum(29.8%), coughing(25.5%), shortness of breath(20.2%), fatique(6.4%), and chest pain(5.3%). In other hand, 57.4% of pneumoconiosis were asymptomatic. 7. The prevalence of pulmonary tuberculosis was radiologically 1.7% in all subjects including 5.3% in pneumoconiosis and 1.3% in no pneumoconiosis(p<0.01).

  • PDF

A Study on Field Applicability of Underground Electric Heating Mesh (매설용 전기 발열 매시의 융설 효과에 대한 현장 적용성 연구)

  • Suh, Young-Chan;Seo, Byung-Seok;Song, Jung-Kon;Cho, Nam-Hyun
    • International Journal of Highway Engineering
    • /
    • v.15 no.2
    • /
    • pp.19-27
    • /
    • 2013
  • PURPOSES : This study aims to investigate the snow-melt effects of an underground electric heater's snow-melt system via a field performance test, for evaluating the suitability of the system for use on a concrete pavement. The study also investigates the effectiveness of dynamic measures for clearing snow after snowfall events. METHODS : In order to check the field applicability, in November 2010, specimens were prepared from materials used for constructing concrete pavements, and underground electric heating meshes (HOT-mesh) were buried at depths of 50 mm and 100 mm at the site of the Incheon International Airport Construction Research Institute. Further, an automatic heating control system, including a motion sensor and pavement-temperature-controlled sensor, were installed at the site; the former sensor was intended for determining snow-melt effects of the heating control system for different snowfall intensities. Pavement snow-melt effects on snowy days from December 2010 to January 2011 were examined by managing the electric heating meshes and the heating control system. In addition, data on pavement temperature changes resulting from the use of the heating meshes and heating control system and on the dependence of the correlation between the outdoor air temperature and the time taken for the required temperature rise on the depth of the heating meshes were collected and analyzed. RESULTS : The effects of the heating control system's preheat temperature and the hot meshes buried at depths of 50 mm and 100 mm on the melting of snow for snowfalls of different intensities have been verified. From the study of the time taken for the specimen's surface temperature to increase from the preheat temperature ($0^{\circ}C$) to the reference temperature ($5{\sim}8^{\circ}C$) for different snowfall intensities, the correlation between the burial depth and outdoor air temperature has been determined to be as follows: Time=15.10+1.141Depth-6.465Temp CONCLUSIONS : The following measures are suggested. For the effective use of the electric heating mesh, it should be located under a slab it may be put to practical use by positioning it under a slab. From the management aspect, the heating control system should be adjusted according to weather conditions, that is, the snowfall intensity.

Causes of Bacterial Growth in Gels and Gel Containers Used for Ultrasonography (초음파 검사용 젤과 젤 용기의 세균증식 원인)

  • Kim, A-Young;Cho, Pyoung-Kon;Song, Do-Young;Kim, Su-Jung
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.359-365
    • /
    • 2020
  • This study aimed to investigate the causes of bacterial growth to prevent infection caused by ultrasound gel and gel containers in contact with patients during ultrasonography. To investigate bacterial contamination during manufacturing or storage, we cultured ultrasound gels originally supplied from three manufacturers. To analyze bacterial growth according to the lapse of time and frequency of use of the ultrasound gel container, the gel and container were cultured at regular intervals every week for 4 weeks. In addition, to determine the source of infection, the examiner's hand was inspected with hand plate and the degree of bacterial contamination was measured before the test. As a result of the study, bacteria were not detected in the gel provided at the initial supply, and in the gel and gel container used repeatedly for 4 weeks, the same bacteria residing on the skin were identified in the examiner's hand, such as Staphylococcus epidermidis, Micrococcus luteus, Leuconostoc mesenteroid spp cremoris, Kocuria rhizophila, and etc. Separated strains were classified as those of the low- or non-pathogenicity; however, most of these strains may render fatal consequences to patients of lower level of immunity due to acquired tolerance to antibiotics. At week 1, when the number of tests was the highest, 44 colonies were identified, and at week 4, when the number of tests was the lowest, 4 colonies were identified. As r=0.994, it was found that the number of colonies increased as the number of tests increased. In conclusion, it was confirmed that the cause of the infection was not the ultrasound gel, but the examiner's hand. The ultrasound gel or gel container may be contaminated by skin flora of examiner's hands, which can cause opportunistic infection in patients with low immunity. The ultrasound gel or gel container may be contaminated by skin flora of examiner's hands, which can cause opportunistic infection in patients with low immunity. Therefore, it was confirmed that thorough hand disinfection was necessary to block healthcare-associated infections.

LC15-0133, a DPP IV Inhibitor: Efficacy in Various Animal Models (LC15-0133, DPP IV 저해제: 여러 동물 모델에서의 효능)

  • Yim, Hyeon-Joo
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 2008.04a
    • /
    • pp.5-20
    • /
    • 2008
  • GLP-1-based drugs (GLP-1 analogues and DPP IV inhibitors) and incretin mimetics are currently one of the most exciting classes of agents for type II diabetes. GLP-1, a gut peptide, is an incretin that potentiates glucose-dependent insulin release from the pancreas, slows GI-transit and stimulates the proliferation of beta-cells. DPP IV inhibitors act like incretins by inhibiting DPP IV which inactivates GLP-1. LC15-0133 is a competitive, reversible DPP IV inhibitor ($IC_{50}$ = 24 nM, Ki=0.247 nM) with excellent selectivity over other critical human proteases such as DPP II, DPP 8, elastase, trypsin. and urokinase. LC15-0133 showed long half-life and good bioavailability in rats and dogs. Inhibition of plasma DPP IV activity by LC15-0133 was kept more than 50% 24 hours after oral dosing in rats and dogs at 0.1 mg/kg and 0.02 mg/kg, respectively. The Minimum effective doses of LC15-0133 were 0.01 mg/kg for lowering blood glucose excursion during oral glucose tolerance test and 0.1 mg/kg for increasing glucose-induced GLP-1 response in C57BL/6 mice. Repeat oral administration of LC15-0133 for 1 month delayed the progression to diabetes and reduced HbA1c levels in a dose-dependent manner in Zucker Diabetic Fatty rats. In conclusion, LC15-0133 is a novel, potent, selective and orally active DPP IV inhibitor and showed an excellent blood glucose lowering effects in various animal models.

  • PDF

Allelopathic Effect of Sorghum Extract and Residues on Selected Crops and Weeds (수수의 타감작용(他感作用)에 관(關)한 연구(硏究))

  • Kim, S.Y.;De Datta, S.K.;Robles, R.P.;Kim, K.U.;Lee, S.C.;Shin, D.H.
    • Korean Journal of Weed Science
    • /
    • v.14 no.1
    • /
    • pp.34-41
    • /
    • 1994
  • To better understand the allelopathic effect of sorghum(Sorghum vulgare L.), the inhibitory activities of water extracts of the stem, leaf and root, and of residues of the stem to major crops and weeds associated with them were evaluated. The allelopathic activity of sorghum plants was species specific, and depended on source and concentration. Germination, and shoot and root length of all test species were inhibited by the different concentrations of the stem extract. Among the crop species, radish showed the most inhibition, followed by wheat and rice. Maize was the least sensitive species. Of the weed species, Ipomoea triloba was most inhibited, followed by Echinochloa colona and Rottboellia cochinchinensis. The water extracts of leaves, stems, and roots significantly inhibited germination and seedling growth in E. colona and radish. The stem extract gave the greatest inhibitory effect on E. colona while all three extracts produced similar response in radish. In the greenhouse trial, sorghum stem residue placed on the soil surface as mulch significantly inhibited seedling growth in E. colona and radish, but not that in rice.

  • PDF

An Assessment of Environmental Characteristics Associated with the Level of Endotoxin Concentration in Hospital Lobbies (일부 종합 병원 로비의 공기 중 엔도톡신 농도에 미치는 환경 요인 평가)

  • Lee, Kyeong-Min;Yeom, Jeongkwan;Lee, Wonjae;Ryu, Seung-Hun;Park, Dongjin;Park, Dong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.310-320
    • /
    • 2014
  • Backgrounds: Endotoxin, which found in the outer membrane of the gram-negative bacteria cell wall, makes up almost all of the lipopolysaccharide(LPS). When people are exposed to endotoxin,it can result in diverse health effects such as an airway irritation and inflammation, fever, malaise, bronchitis, allergic asthma, toxic pneumonitis, hypersensitivity lung disease. Cases among the elderly, children or pregnant can occur more frequently than a healthy adult if they are repeatedly exposed to the existing endotoxin. Therefore, we investigated and assessed the environmental characteristics associated with the airborne endotoxin concentration level in six hospital lobbies. Method: Endotoxin from indoor air in six hospital lobbies was measured by an area sampling method and analyzed according to American Society for Testing and Materials International(ASTM international) E2144-01. Total suspended particulate(TSP), carbon dioxide($CO_2$), temperature and humidity were also measured by using direct reading measurements or airborne sampling equipment at the same time. Environmental characteristics were appropriately divided into two or three groups for a statistics analysis. One-way analysis variable(one-way ANOVA) was used to examine a difference of the endotoxin concentration, depending on the environmental characteristics. In addition, only variables with p-value(p<0.25) were eventually designed to the best model by using multiple regression analysis. Results: The correlation analysis result indicated that TSP(p=0.003) and $CO_2$(p<0.0001) levels were significantly associated with endotoxin concentration levels. In contrast, temperature(p<0.068) and humidity(p<0.365) were not associated with endotoxin concentration. Levels of endotoxin concentration were statistically different among the environmental characteristics of Service time(p=0.01), Establishment of hospital(p<0.001), Scale of hospital(p=0.01), Day average people using hospital(p=0.03), Cleaning time of lobby(p=0.05), Season(p<0.001), and Cleaning of ventilation system(p<0.001) according to ANOVA. Finally, the best model(Adjusted R-square=72%) that we designed through a multiple regression test included environmental characteristics related to Service time, Area of lobby, Season, Cleaning of ventilation system, and Temperature. Conclusions: According to this study, our result showed a normal level of endotoxin concentration in the hospital lobbies and found environmental management methods to reduce the level of endotoxin concentration to a minimum. Consequently, this study recognized to be requirement for the management of ventilation systems and an indoor temperature in order to reduce the level of endotoxin concentration in the hospital lobbies.