• 제목/요약/키워드: R-peak

Search Result 1,502, Processing Time 0.036 seconds

Estimation of CTD and Peak-to-Peak CDV Allocation to Nodes in Domestic Region (국내영역에서 셀전달지연 추정 및 peak-to-peak CDV 노드별 할당)

  • Park, Chun-Kwan;Han, Jong-Seok
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.2
    • /
    • pp.6-12
    • /
    • 2001
  • When CBR source traffics are loaded to ATM switch and broadband network termination, CTD values of ATM switch and broadband network termination are measured and then the values of CTD in the domestic region arc estimated. The estimation values of CTD satisfy the objective of CTD in the domestic region allocated by allocation rules of 1.356. The peak-to-peak CDV allocation method based On Chernoff accumulation method is proposed and applied to the nodes of national portion. From the result of numerical analysis, the proposed method is more accurate than the equal allocation method for peak -to-peak CDV in case that the CDVs at each node and the number of ATM nodes on the path increase.

  • PDF

A Study of Crystalline Behaviour on $\textrm{As}^{+}$ Ion-Implanted Silicon (As 이온 주입된 Si의 결정성 거동에 관한 연구)

  • Mun, Yeong-Hui;Song, Yeong-Min;Kim, Jong-O
    • Korean Journal of Materials Research
    • /
    • v.9 no.1
    • /
    • pp.99-103
    • /
    • 1999
  • We investigated the crystalline behavior in active ion implanted silicon through Raman spectroscopy. Four a-Si(amorphous Si) peaks were observed that are related to the ion implantation induced a-Si layer. After the isochronical anneal(30min). and isothermal anneal($450^{\circ}C$), noticeable recovery of crystalline-Si peak at 519cm\ulcorner and peak center shift of the a-Si TO from 465cm\ulcorner to 480cm\ulcorner were observed by RNM(Random Network Model). By applying RNM and SCLM(Spatial Correlation Length Model), the peak center and FWHM(the Full Width at half Maximum) of a-Si were changed dramatically between T\ulcorner=$200^{\circ}C$ and 30$0^{\circ}C$. From the results, it can be said that there is an abrupt structural change at this temperature region.

  • PDF

Effect of Surface Grinding on Low Temperature Degradation of 3Y-TZP (표면 연마가 3Y-TZP의 저온열화에 미치는 영향)

  • 김대준;이홍림;정형진
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.2
    • /
    • pp.164-168
    • /
    • 1993
  • Grinding of 3mol% Y-TZP enhanced the texturing of t-ZrO2, which is represented by the increased I(002)t/I(200)t peak intensity ratio, and an asymetric broadening of (111)t peak. The degree of texturing and asymetric broadening depended on a seversity of grinding. The asymetric (111)t peak broadening was resulted by the formation of r-ZrO2. When aged at 25$0^{\circ}C$ for 120h, r-ZrO2 transformed to t-ZrO2 due to the relief of stressed surface area and the amount of tlongrightarrowm transformation inversely varied with the I(002)t/I(200)t. The inverse dependence was interpreted by that the degree of texturing determines the magnitude of residual surface stress and the lattice relaxation of t-ZrO2, which causes the low temperature degradation, is retarded as the residual stress becomes greater.

  • PDF

Attenuation of Peak Horizontal Acceleration in the Sino-Korea Craton (Sino-Korea Craton에서 최대수평가속도의 감쇠)

  • 이기화;조광현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.3-10
    • /
    • 2002
  • The strong ground motion data recorded in the Sino-Korea Craton are analysed toobtain attenuation relations valid for 5 < M < 8, r < 400 km applicable to the Korean Peninsula. The result is logA : -1.83+0.386M- log${\gamma}$-0.0015${\gamma}$ where A is peak horizontal acceleration in g, M is surface-wave magnitude, and r is hypocentral distance in km. Our result is compared with the existing attenuation relations of Western North America and Eastern North America and the prior predictive equations for the Southern part of Korean Peninsula. Our result compares better with those of North America than those of the Southern part of the Korean Peninsula. More theoretical and empirical studies are required for better attenuation relations appropriate for the Korean Peninsula.

  • PDF

Solid-Phase crystallization of amorphous silicon films deposited by plasma-enhanced chemical vapor deposition

  • Lee, Jung-Keun
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.2 no.1
    • /
    • pp.49-54
    • /
    • 1998
  • The effect of deposition paratmeters on the solid-phase crystallization of amorphous silicon films deposited by plasma-enhanced chemical vapor deposition has been investigated by x-ray diffraction. The amorphous silicon films were prepared on Si(100) wafers using SiH4 gas with and without H2 dilution at the substrate temperatures between 12$^{\circ}C$ and 38$0^{\circ}C$. The R. F. powers and the deposition pressures were also varied. After crystallizing at $600^{\circ}C$ for 24h, the films exhibited (111), (220), and (311) x-ray diffraction peaks. The (111) peak intensity increased as the substrate temperature decreased, and the H dilution suppressed the crystallization. Increasing R.F. powers within the limits of etching level and increasing deposition pressures also have enhanced the peak intensity. The peak intensity was closely related to the deposition rate, which may be an indirect indicator of structural disorder in amorphous silicon films. Our results are consistent with the fact that an increase of the structural disorder I amorphous silicon films enhances the grain size in the crystallized films.

A comparative study on aseismic performances of base isolation systems for multi-span continuous bridge (다경간 연속교에 대한 면진용 교좌장치의 내진성능 비교연구)

  • Park, Kyu-Sik;Lee, Chong-Heon;Lee, In-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.383-390
    • /
    • 2001
  • Various base isolation systems, which are widely used, are compared for aseismic performances of multi-span continuous bridge. They are the P-F, RB, LRB, R-FBI and EDF systems. Sensitivity analyses are carried out to determine the design parameters of various devices. The design parameters, natural period of the isolated bridge and friction coefficient of the bearing, are determined by the reciprocal relationship between displacement and bending moment of the structure. Then the relative effectiveness of the bearings is described. Bridge with the R-FBI system shows the smallest peak displacement of deck whereas bridge with the EDF system shows the smallest peak bending moment of the lower end of pier in numerical examples. Furthermore, the peak responses of bridge with the friction type bearing are less sensitive to substantial variations in the frequency range and intensity of the ground excitation than those with the rubber type bearing.

  • PDF

Antibacterial Activity and Component Analysis of Persicaria perfoliata Extracts (며느리배꼽 추출물의 항균 작용과 성분 분석)

  • Kim, Sun-Young;Won, Doo-Hyun;Park, Soo-Nam
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.3
    • /
    • pp.278-282
    • /
    • 2010
  • In this study, the antibacterial activity and component analysis of Persicaria perfoliata extracts were investigated. MIC (Minimum Inhibitory Concentration) values of ethyl acetate fraction from P. perfoliata on Escherichia coli, Propionibacterium acnes, and Staphylococcus aureus were 0.25%, equally. The results showed that the antibacterial activity of the ethyl acetate fraction was the highest in the S. aureus and P. acnes. Ethyl acetate fraction from P. perfoliata extracts showed 5 bands in TLC and 8 peaks in HPLC (320nm). In HPLC chromatogram of ethyl acetate fraction, first main peak 2 (24.99%) and peak 3 (22.65%) were identified as quercetin-3-o-glucuronide and isoquercitrin in the order of elution time. Also, in HPLC chromatogram of deglycosylated fraction, main peak 2 (76.93%) was identified as quercetin in the order of elution time. And these components are very effective as antioxidants. Thus, these results indicate that extract/fractions of P. perfoliata can be applicable to new functional cosmetics for antioxidant, antibacterial activity.

The Normal Predicted Value of Peak Expiratory Flow(PEF) Measured by the Peak Flow Meter and Correlation Between PEF and Other Ventilatory Parameters (Peak Flow Meter로 측정한 최대호기류속도(PEF)의 추정정상치 및 가타 환기기능검사와의 상관관계)

  • Kim, Min-Chul;Kwon, Kee-Buem;Yim, Dong-Hyun;Song, Chang-Seuk;Jung, Yong-Seuk;Jang, Tae-Won;Yeu, Ho-Dae;Jung, Maan-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1000-1011
    • /
    • 1998
  • Background: For the diagnosis or evaluation of airway obstruction in bronchial asthma and chronic obstructive lung disorders, various parameters derived from the forced expiratory volume curve and maximal expiratory flow volume curve have been used. Recently the peak expiratory flow(PEF) measured by the peak flow meter is widely used because of its simplicity and convenience. But there were still no data of the predicted normal values measured by the peak flow meter in Korea. This study was to obtain the predicted normal value of PEF and to know the accuracy of this value to predict $FEV_1$. Method: The measurements of PEF by the MiniWright peak flow meter and several parameters derived from the forced expiratory volume and maximal expiratory flow volume curves by the Microspiro HI 501(Chest Co.) were done in 129 men and 125 women without previous history of the respiratory diseases. The predicted normal values of parameters according to the age and the height were obtained, and the regression equation of $FEV_1$ by PEF was calculated. Results: The predicted normal values of PEF(L/min) were -2.45$\times$Age(year) +1.36 $\times$ Height(cm)+427 in men, and -0.96 $\times$ Age (year) + 2.01 $\times$ Height (cm) + 129 in women. FEFmax derived from the maximal expiratory flow volume curve was less than by 125 L/min in men and 118 L/min in women respectively compared to PEF. $FEV_1$(ml) predicted by PEF was 5.98 $\times$ PEF(L/min) + 303 in men, and 4.61 $\times$ PEF(L/min) + 291 in women respectively. Conclusion : The predicted normal value of PEF measured by the peak flow meter was calculated and it could be used as a standard value of PEF while taking care of patients with airway obstruction. $FEV_1$, the gold standard of ventilatory function, could be predicted by PEF to a certain extent.

  • PDF

A Study of the Thermoluminescent Properties of Korean Natural Quartz for Possible Use in Gamma-ray Dosimetry

  • Lee, Hee-Yong;Kim, Hi-Gyu;Lee, Chul
    • Nuclear Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.229-239
    • /
    • 1970
  • Various thermoluminescent properties of Korean natural quartz for possible use in ${\gamma}$-ray dosimetry has been studied. If the heating is exactly linear, ${\gamma}$-irradiated radiation sensitive (type 1) $\alpha$-quartz can yield a glow curve of single peak, hence glow peak height could be taken as a ${\gamma}$-dose for its dosimetry. Quartz crystal dosimeter exhibited the linearity of thermoluminescent intensity in the range from about 2$\times$10$^{3}$R to 2$\times$10$^{6}$ R, and also had an advantage of low fading because of the high peak temperature (300$\pm$4$0^{\circ}C$). The pulverized quartz sample having the grain size of 0.3<ø<0.9mm showed the linearity of T. L. intensity in the range from 50R to 2$\times$10$^3$R. Therapeutic application of the pulverized sample on the correct measurement of the absorbed dose in a body region of a cancer patient seems to be successful.

  • PDF

Heart Beat Interval Estimation Algorithm for Low Sampling Frequency Electrocardiogram Signal (낮은 샘플링 주파수를 가지는 심전도 신호를 이용한 심박 간격 추정 알고리즘)

  • Choi, Byunghun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.898-902
    • /
    • 2018
  • A novel heart beat interval estimation algorithm is presented based on parabola approximation method. This paper presented a two-step processing scheme; a first stage is finding R-peak in the Electrocardiogram (ECG) by Shannon energy envelope estimator and a secondary stage is computing the interpolated peak location by parabola approximation. Experimental results show that the proposed algorithm performs better than with the previous method using low sampled ECG signals.