• 제목/요약/키워드: R-C circuit

검색결과 288건 처리시간 0.032초

적분근사를 이용한 거리 계전 알고리즘 (A Distance Relaying Algorithm Based on the Integral Approximation of a Differential Equation)

  • 정병태;서장철;조경래;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.180-182
    • /
    • 1993
  • A distance protection algorithm for detecting faults at power transmission lines is presented in this paper. The algorithm is based on the differential equation related to the voltage and the current at an equivalent circuit of a transmission line which is composed of the lumped resistance and inductance. The presented integration method has high performance at though the fault voltage and the current are heavily distorted with the DC offset and harmonics which occurred at transient states after faults.

  • PDF

단상 AC/DC 승압형 컨버터를 이용한 피복 아크 용접기 역률 개선에 관한 연구 (A Study On Power Factor Correction of SMAW(shielded metal-arc welding) Using Single Phase AC/DC Boost Converter)

  • 유영진;김이훈;김준호;원충연;김영렬;이상용
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.556-559
    • /
    • 2001
  • In this paper, we proposed AC/DC boost converter to improve input current harmonic reduction in SMAW(shielded metal-arc welding). The proposed harmonic reduction with the boost converter design and the UC2854 integrated circuit which controls the converter, The topology of welding power supply is made of a pair of boost converter and welder half-bridge IGBT inverter. The voltage arc is modeled by a variable resistance in series with a voltage source. The results has been confirmed by PSIM simulation tool. The simulation results show that input at current is nearly sinusoidal with low harmonic contents and sinusoidal input current waveform at high power factor.

  • PDF

FEM을 이용한 유도 전동기의 벡터제어 특성 해석 연구 (The Analysis on Vector Control Characteristics of IM Using Finite Element Method)

  • 임달호;권병일;이중호;우경일;김창업
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.56-58
    • /
    • 1995
  • Dynamic characteristics of the vector controlled induction motor has been analysed using d-q equivalent circuit. However, for the design of the induction motor, the analysis of an accurate response characteristic are needed. In this paper, dynamic characteristic analysis method using 2-D Finite Element Method (FEM), which takes the motion equation of the rotor into account and considers the physical motion of the rotor by an automatic subdivision of mesh, are explained.

  • PDF

새로운 저항성 누전전류 측정 방법 (A New Method for Resistive Leakage Current Measurement)

  • 함승진;한송엽;고창섭
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1397-1404
    • /
    • 2007
  • It is important to measure the resistive component separately from the total leakage current at power distribution line. It is because electric disasters such as electric shock and fire are caused mainly by the resistive component of the total leakage current. In this paper, a new theory for measuring the resistive component separately from the total leakage current is suggested, and is embodied to an actual circuit using operational amplifiers, analog switch and R-C low pass filter. Through experiments for various cases containing both the resistive and capacitive leakage currents, the suggested algorithm is confirmed to be able to measure the resistive leakage current within 4.1% of error even when the capacitive leakage current is much bigger than the resistive one. The suggested method is expected to lower the total cost because it can be realized using simple and cheap devices, and implies the measuring time can be possibly reduced because the resistive leakage current is computed exactly from the signals during only a half period of power voltage.

급전방식에 따른 레일전류 분포 예측 (The Estimation of Rail Current Distribution According to Feeding Scheme)

  • 이장무;한문섭;정호성;김주락;김형철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1619-1621
    • /
    • 2005
  • AC electric railway feeding system classifies into three groups such as normal, TIE and PP feeding method. If the feeding scheme of ac electric railway is changed, current distribution flowing through the line is also modified. And if the current distribution is altered according to the feeding scheme, returned tendency through rail load current or fault current of the train is changed. So the investigation about error correcting method of protective relay is needed considering feeding scheme. In this paper prior to error correcting of protective relay, through interpreting feeding circuit, changes in current distribution of the rail in accordance with feeding would be predicted and analyzed.

  • PDF

분진 및 질소산화물 동시처리를 위한 1톤 중유 보일러용 세라믹 필터 집진기의 성능실험 (Performance Test of Ceramic Filter Collector for the heavy-oil boiler for Concurrent treatment Dust and Nitrogen Oxides)

  • 정완보;조정식
    • 한국산업융합학회 논문집
    • /
    • 제21권6호
    • /
    • pp.355-360
    • /
    • 2018
  • The product developed in this study is a ceramic catalyst filter for 1 ton heavy-oil boiler that can simultaneously process dust and nitrogen oxides. This has been developed for simultaneous processing of nitrogen oxides and dust at high efficiency of hot exhaust gas (approximately $300^{\circ}C$) generated after burning 1 ton heavy oil boiler. Ceramic catalytic filters for 1 tonne heavy-duty glass display are technologies that remove 90% of dust and 85% or more of nitrogen oxides. This is an improved new technology to integrate exhaust ventilation and desiccation devices into one, thereby reducing the production process and improving the economy. To this end, the performance test of the catalytic filter for heavy oil boilers was carried out, and the durability of the PLC circuit was constructed.

STATCOM Helps to Guarantee a Stable System

  • Andersen, B.R;Gemmell, B.D.;Horwill, C.;Hanson, D.J.
    • Journal of Power Electronics
    • /
    • 제1권2호
    • /
    • pp.65-70
    • /
    • 2001
  • Transmission System Operators are governed by operational security standards that are applied in real time. During system disturbances, the System Operators must rely on the installed protection and control equipment, prior to human intervention. New power electronic solutions bring rapid and repeatable responses to disturbances, which will help System Operators to guarantee a stable system. Last year, Alstom completed the world's first competitively bid STATCOM to support the voltage on National Grid's 400kV network that supplies London and the Southeast from the north of the UK. It is rated ${\pm}75MVAr$ and forms part of a Static Var System (SVS) with a total rating of 0 to 225MVAr. This paper will describe the reasons for its size, location, its chain-link configuration and give examples of its operating performance. The paper will also describe the features that allow this STATCOM to deliver much more than reactive compensation in support of a wider transmission service objective, as system conditions require.

  • PDF

고온 초전도 경사형 모서리 접합을 이용한 4단 쉬프트 레지스터의 동작 (Operation of a Single Flux Quantum 4-stage Shift Register Fabricated with High $T_c$ Ramp-edge Junction Technology)

  • 김준호;박종혁;김상협;정구락;강준희;성건용;한택상
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.83-86
    • /
    • 2001
  • We have fabricated a single flux quantum 4-stage shift register with interface-controlled $Y_1$$Ba_2$$Cu_3$$O_{7-x}$(YBCO) Josephson junction. The YBCO Josephson junctions showed RSJ-like current-voltage(I-V) curves at temperatures 45~80K. We tested load and shift operation of shift register with binary data sequences “1000”, “1010”, “1011”, and “1111” at 58K. For all the binary data sequences, the shift register operated successfully. By operating the circuit with proper current pulses, we observed no errors during at least 12 hours operation for all the data sequences.s.

  • PDF

EIS를 활용한 철근 부식에 따른 콘크리트 손상 모니터링 (Monitoring of Concrete Deterioration Caused by Steel Corrosion using Electrochemical Impedance Spectroscopy(EIS))

  • 우성엽;김제경;이정재;기성훈
    • 한국건축시공학회지
    • /
    • 제22권6호
    • /
    • pp.651-662
    • /
    • 2022
  • 이 연구에서는 전기화학적 임피던스분광법(Electrochemical Impedance Spectroscopy, EIS)을 활용하여 콘크리트 속 철근 부식의 개시, 전파 및 이로 인한 콘크리트의 손상을 관찰하기 위한 실험을 수행하였다. 먼저, 직경 25mm, 높이 70mm 원주형 콘크리트 실험체 중심에 지름 5mm의 탄소강봉을 매입한 실험체를 제작하였다. 실험체에 사용된 콘크리트는 물-시멘트 비 0.4, 0.5, 0.6을 갖는 세 가지 배합을 제작하였다. 촉진부식시험을 수행하여 위하여 철근 콘크리트 실험체는 0.5M NaCl 수용액에 침지한 후 0C, 13C, 65C, 130C의 네 가지 수준의 전하량을 인가하였다. 이 연구에서는 부식촉진 및 이 과정에서 EIS의 주기적 모니터링을 자동화하여 실험의 효율을 향상시켰다. 이 연구의 실험 결과를 통하여 EIS 주요 특성인자를 활용하여 콘크리트 속 철근의 부식상태를 효과적으로 평가할 수 있음을 확인하였다. 전하이동저항(Rc)값은 전하인가량이 0C에서 13C로 증가함에 따라 급격히 감소하여 대략 10kΩcm2 값을 나타내었다. 하지만 부식개시 이후 전하인가량을 13C에서 130C로 증가하였을 때 Rc값의 민감도는 현저히 감소하는 것을 확인하였다. 한편 이중층용량값(Cdl)값은 전하인가량이 0C에서 130C로 증가함에 따라 대략 50×10-6μF/cm2 에서 250×10-6μF/cm2 수준으로 선형비례관계를 보였다. 이러한 결과는 Cdl 모니터링을 통하여 부식물질에 팽창에 따라 유발된 콘크리트 내부 손상의 진전을 효과적으로 평가할 수 있음을 보여준다. 이 연구의 결과는 EIS를 활용하여 콘크리트 속 철근 부식의 확산 및 이에 따른 콘크리트 손상의 실시간 모니터링을 위한 매입형 센서 및 EIS 신호 분석방법의 고도화를 위한 기본 데이터를 제공하는데 의미가 있다.

MBF 20으로 브레이징한 STS304 콤팩트 열교환기 접합부의 미세조직에 미치는 가열속도의 영향 (Effect of Heating Rates on Microstructures in Brazing Joints of STS304 Compact Heat Exchanger using MBF 20)

  • 김준태;허회준;김현준;강정윤
    • Journal of Welding and Joining
    • /
    • 제34권2호
    • /
    • pp.46-53
    • /
    • 2016
  • Effect of heating rate on microstructure of brazed joints with STS 304 Printed Circuit Heat Exchanger (PCHE),which was manufactured as large-scale($1170(L){\times}520(W)){\times}100(T)$, mm), have been studied to compare bonding phenomenon. The specimens using MBF 20 was bonded at $1080^{\circ}C$ for 1hr with $0.38^{\circ}C/min$ and $20^{\circ}C/min$ heating rate, respectively. In case of a heating rate of $20^{\circ}C/min$, overflow of filler metal was observed at the edge of a brazed joints showing the height of filler metal was decreased from $100{\mu}m$ to $68{\mu}m$. At the center of the joints, CrB and high Ni contents of ${\gamma}$-Ni was existed. For the joints brazed at a heating rate of $0.38^{\circ}C/min$, the height of filler was decreased from $100{\mu}m$ to $86{\mu}m$ showing the overflow of filler was not appeared. At the center of the joints, only ${\gamma}$-Ni was detected gradating the Ni contents from center. This phenomenon was driven from a diffusion amount of Boron in filler metal. With a fast heating rate $20^{\circ}C/min$, diffusion amount of B was so small that liquid state of filler metal and base metal were reacted. But, for a slow heating rate $0.38^{\circ}C/min$, solid state of filler metal due to low diffusion amount of B reacted with base metal as a solid diffusion bonding.