Performance Test of Ceramic Filter Collector for the heavy-oil boiler for Concurrent treatment Dust and Nitrogen Oxides

분진 및 질소산화물 동시처리를 위한 1톤 중유 보일러용 세라믹 필터 집진기의 성능실험

  • Received : 2018.09.27
  • Accepted : 2018.12.04
  • Published : 2018.12.31

Abstract

The product developed in this study is a ceramic catalyst filter for 1 ton heavy-oil boiler that can simultaneously process dust and nitrogen oxides. This has been developed for simultaneous processing of nitrogen oxides and dust at high efficiency of hot exhaust gas (approximately $300^{\circ}C$) generated after burning 1 ton heavy oil boiler. Ceramic catalytic filters for 1 tonne heavy-duty glass display are technologies that remove 90% of dust and 85% or more of nitrogen oxides. This is an improved new technology to integrate exhaust ventilation and desiccation devices into one, thereby reducing the production process and improving the economy. To this end, the performance test of the catalytic filter for heavy oil boilers was carried out, and the durability of the PLC circuit was constructed.

Keywords

SOOOB6_2018_v21n6_355_f0001.png 이미지

Fig. 1 Performance test device of ceramic filters

SOOOB6_2018_v21n6_355_f0002.png 이미지

Fig. 2 Ceramic filter area measurement

SOOOB6_2018_v21n6_355_f0003.png 이미지

Fig. 3 Pressure loss experiment

SOOOB6_2018_v21n6_355_f0004.png 이미지

Fig. 4 Pressure Loss data of ceramic filter

SOOOB6_2018_v21n6_355_f0005.png 이미지

Fig. 5 Durable life test device

SOOOB6_2018_v21n6_355_f0006.png 이미지

Fig. 6 Durable life test data

SOOOB6_2018_v21n6_355_f0007.png 이미지

Fig. 8 Measurement at the rear of the baghouse(C1)

SOOOB6_2018_v21n6_355_f0008.png 이미지

Fig. 7 NOx reduction by temperature

SOOOB6_2018_v21n6_355_f0009.png 이미지

Fig. 9 Exhaust gas temperature

Table 1. Regulation of nitrogen oxides on ships

SOOOB6_2018_v21n6_355_t0001.png 이미지

Table 2. Regulation of sulfur oxides in the seas

SOOOB6_2018_v21n6_355_t0002.png 이미지

Table 3. Concentration of dust emission

SOOOB6_2018_v21n6_355_t0003.png 이미지

References

  1. Han, B. W., Kim, H. J., Kim, Y. J., Song, D. K., Hong, W. S. and Shin, W. H., 2011, "Characteristics of Charging and Collection of 10nm Class Ultrafine Nanoparticles in an Electrostatic Precipitator", Trans. Korean Soc. Mech Eng. B, Vol. 35, No. 10, pp.1013-1018 https://doi.org/10.3795/KSME-B.2011.35.10.1013
  2. Witt, P. J., Solnordal, C. G., Mittoni, L. J., Finn, S., Pluta, J. 2006, "Optimizing the design of fume extraction hoods using a combination of engineering and CFD modelling", Applied Mathematical Modelling, Vol. 30, pp.1167-1179. https://doi.org/10.1016/j.apm.2006.02.003
  3. Lim, K. B., Lee, K. S. and Lee, C. H., 2006, "A numerical study on the flow characteristics of kitchen hood system", Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 18, No. 4 pp. 359-369.
  4. Sung-Cheol Jang, Jung-Sick Cho, 2018, "A Basic Study on the Portable Collector of Ship Gausing", KSPSE Spring Conference, pp.139-141.
  5. Sung-Cheol Jang, Dae-Young Jung, Jung-Sick Cho, 2018, "Flow Analysis of Cyclone-Cartridge Filter Gausing Collector", KSIC, Vol. 21, No. 3 pp. 133-140.
  6. Test report, KIST, R0004290.