• 제목/요약/키워드: R/C buildings

검색결과 127건 처리시간 0.028초

Influence of bi-directional seismic pounding on the inelastic demand distribution of three adjacent multi-storey R/C buildings

  • Skrekas, Paschalis;Sextos, Anastasios;Giaralis, Agathoklis
    • Earthquakes and Structures
    • /
    • 제6권1호
    • /
    • pp.71-87
    • /
    • 2014
  • Interaction between closely-spaced buildings subject to earthquake induced strong ground motions, termed in the literature as "seismic pounding", occurs commonly during major seismic events in contemporary congested urban environments. Seismic pounding is not taken into account by current codes of practice and is rarely considered in practice at the design stage of new buildings constructed "in contact" with existing ones. Thus far, limited research work has been devoted to quantify the influence of slab-to-slab pounding on the inelastic seismic demands at critical locations of structural members in adjacent structures that are not aligned in series. In this respect, this paper considers a typical case study of a "new" reinforced concrete (R/C) EC8-compliant, torsionally sensitive, 7-story corner building constructed within a block, in bi-lateral contact with two existing R/C 5-story structures with same height floors. A non-linear local plasticity numerical model is developed and a series of non-linear time-history analyses is undertaken considering the corner building "in isolation" from the existing ones (no-pounding case), and in combination with the existing ones (pounding case). Numerical results are reported in terms of averages of ratios of peak inelastic rotation demands at all structural elements (beams, columns, shear walls) at each storey. It is shown that seismic pounding reduces on average the inelastic demands of the structural members at the lower floors of the 7-story building. However, the discrepancy in structural response of the entire block due to torsion-induced, bi-directionally seismic pounding is substantial as a result of the complex nonlinear dynamics of the coupled building block system.

유사동적실험에 의한 탄성패드 접합 H형 철골프레임공법으로 보강 된 기존 중·저층 R/C 골조의 내진성능 평가 (Seismic Capacity Evaluation of Existing Medium-and low-rise R/C Frame Retrofitted by H-section Steel Frame with Elastic Pad Based on Pseudo-dynamic testing)

  • 김진선;이강석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권4호
    • /
    • pp.83-91
    • /
    • 2021
  • 본 연구에서는 기존 철근콘크리트 (R/C) 구조체와 내진보강 부재의 접합부의 성능을 향상시키기 위해서 접합부에 탄성패드를 가지는 새로운 H형강 철골프레임 내부접합형 내진보강공법 (H-section Steel Frame with Elastic Pad, HSFEP)을 제안하였다. HSFEP 시스템은 필요 내진보강량 산정이 간편한 내력향상형 보강공법으로서, 전단파괴가 발생할 가능성이 매우 높은 비내진상세를 가지는 중·저층 R/C 건축물에 적합한 공법이다. 본 연구에서 제안한 HSFEP 내진보강공법의 유용성을 검증하기 위하여 비내진상세를 가지는 국내 R/C 건축물을 바탕으로 실물 2층 골조 실험체를 제작하여 유사동적실험을 수행하여 최대지진응답 하중 및 변위, 지진피해정도를 중심으로 내진보강효과를 검토하였다. 실험결과 본 연구에서 개발한 HSFEP 내부접합형 내진보강법은 접합부성능이 개선되었으며, 효과적으로 수평극한내력을 증진시킴과 동시에 대지진 입력 시에도 지진응답변위를 매우 효과적으로 억제시켰다.

Identifying stiffness irregularity in buildings using fundamental lateral mode shape

  • Vijayanarayanan, A.R.;Goswami, Rupen;Murty, C.V.R.
    • Earthquakes and Structures
    • /
    • 제12권4호
    • /
    • pp.437-448
    • /
    • 2017
  • Soft or extreme soft storeys in multi-storied buildings cause localized damage (and even collapse) during strong earthquake shaking. The presence of such soft or extremely soft storey is identified through provisions of vertical stiffness irregularity in seismic design codes. Identification of the irregularity in a building requires estimation of lateral translational stiffness of each storey. Estimation of lateral translational stiffness can be an arduous task. A simple procedure is presented to estimate storey stiffness using only properties of fundamental lateral translational mode of oscillation (namely natural period and associated mode shape), which are readily available to designers at the end of analysis stage. In addition, simplified analytical expressions are provided towards identifying stiffness irregularity. Results of linear elastic time-history analyses indicate that the proposed procedure captures the irregularity in storey stiffness in both low- and mid-rise buildings.

비선형동적해석에 의한 2016년 경주지진에서 지진피해를 받은 R/C 건물의 내진성능에 관한 연구 (A Seismic Capacity of R/C Building Damaged by the 2016 Gyeongju Earthquake Based on the Non-linear Dynamic Analysis)

  • 정주성;이강석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권1호
    • /
    • pp.137-146
    • /
    • 2018
  • 2016년 경주지진 이후로 국내에서도 본격적으로 건축물의 지진대책 강구가 시급한 시점에서 국내에 널리 보급되어 있는 R/C 건축물의 효율적인 내진성능 평가 및 내진보강을 포함한 내진대책을 위한 기초적인 자료를 얻고자, 2016년 경주지진에서 지진피해를 받은 R/C 저층 학교건축물(M학교)을 대상으로 지진피해도구분판정법을 이용하여 잔존내진성능과 지진피해정도를 평가함과 동시에, 부재수준의 비선형동적해석을 수행하여 지진피해정도와의 상관관계를 검토하였다. 지진피해도구분판정에 의한 손상도-I로 분류된 기둥은 2개, 손상도-II가 1개, 손상도-III으로 분류된 기둥이 3개로 각각 평가되어, 최종적으로 평가한 내진성능잔존율(R)은 88.2%로 피해분류는 소규모 피해로 판정되었으며, 또한 비선형동적해석 결과 1층 X방향의 최대응답을 나타낸 기둥의 휨변위는 0.7 mm, 전단변위는 6 mm로 전단균열은 발생하였지만, 전단파괴는 발생하지 않았다. 경주지진에서 지진피해를 입은 M학교의 지진피해가 1층의 X방향에 집중되어 있다는 사실, 휨균열보다는 전단균열이 발생하였다는 사실을 고려한다면 본 연구에서 수행한 비선형동적해석 결과는 2016년 경주지진에서 지진피해를 받은 M학교의 지진피해상황을 잘 반영하고 있다고 사료되며, 국내 기존 저층 R/C 건축물의 효율적인 내진성능 평가 및 내진보강을 포함한 내진대책을 위한 기초적인 자료로서 활용가능하다고 사료된다.

Effectiveness of R/C jacketing of substandard R/C columns with short lap splices

  • Kalogeropoulos, George I.;Tsonos, Alexander G.
    • Structural Monitoring and Maintenance
    • /
    • 제1권3호
    • /
    • pp.273-292
    • /
    • 2014
  • The effectiveness of a retrofitting method for concrete columns with particular weaknesses is experimentally evaluated and presented in this paper. Structural deficiencies namely the inadequacy of transverse reinforcement and short length of lap splices are very common in columns found in structures built prior to the 1960s and 1970s. Recent earthquakes worldwide have caused severe damages and collapses of these structures. Nevertheless, the importance of improving the load transfer capacity between the deficiently lap-spliced bars is usually underestimated during the strengthening procedures applied in old buildings, though critical for the safety of the residents' lives. Thus, the seismic performance of the enhanced columns is frequently overestimated. The retrofitting approach presented herein involves reinforced concrete jacketing of the column sub-assemblages and welding of the lap-spliced bars to prevent the splice failure and conform to the provisions of modern design Codes. The cyclic lateral loading response of poorly confined original column specimens with insufficient lap splices and the seismic behavior of the retrofitted columns are compared. Test results clearly demonstrate that the retrofitting procedure followed is an effective way of significantly improving the seismic performance of substandard columns found in old buildings.

저층 철근콘크리트 건물의 지진응답특성 (Seismic Response Characteristics of Low-Rise R/C Buildings)

  • 이강석;오재근;최창식;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.223-226
    • /
    • 2005
  • The purpose of this study is to discuss how strength and ductility of each system in low-rise R/C buildings combined with extremely brittle, shear and flexural failure systems have influence on seismic capacities of the overall system, which is based on seismic response analysis of SDOF structural systems. To simulate the triple lateral-load resisting system, structures are idealized as a parallel combination of two modified origin-oriented hysteretic models and degrading trilinear hysteretic model that fail primarily in extremely brittle, shear and flexure, respectively. Stiffness properties of three models are varied in terms of story shear coefficients, and structures are subjected to two ground motion components. By analyzing these systems, interaction curves of required strengths of the triple systems for various levels of ductility factors are finally derived for practical purposes.

  • PDF

Seismic assessment of a R/C strategic existing building

  • Mehani, Youcef;Kibboua, Abderrahmane
    • Structural Engineering and Mechanics
    • /
    • 제26권6호
    • /
    • pp.617-634
    • /
    • 2007
  • Algeria is a country with a high seismic activity. During the last decade, many destructive earthquakes occurred, particularly in the northern part, causing enormous losses in human lives, buildings and equipments. In order to reduce this risk in the capital and avoid serious damages to the strategic existing buildings, the government decided to invest into seismic upgrade, strengthening and retrofitting of these buildings. In doing so, seismic vulnerability study of this category of buildings has been considered. Structural analysis is performed on the basis of site investigation (inspection of the building, collecting data, materials, general conditions of the building, etc), and existing drawings (architectural plans, structural design, etc). The aim of these seismic vulnerability studies is to develop guidelines and a methodology for rehabilitation of existing buildings. This paper will provide insight to the vulnerability assessment and strengthening of the telecommunication centre, according to the new code RPA 99/version 2003. Both, static equivalent method and non linear dynamic analysis are performed in this study.

Seismic spectral acceleration assessment of masonry in-filled reinforced concrete buildings by a coefficient-based method

  • Su, R.K.L.;Lee, C.L.;Wang, Y.P.
    • Structural Engineering and Mechanics
    • /
    • 제41권4호
    • /
    • pp.479-494
    • /
    • 2012
  • This study explores a coefficient-based seismic capacity assessment method with a special emphasis on low-rise masonry in-filled (MI) reinforced concrete (RC) buildings subjected to earthquake motion. The coefficient-based method without requiring any complicated finite element analysis is a simplified procedure to assess the maximum spectral acceleration capacity of buildings. This paper first compares the fundamental periods of MI RC structures obtained, respectively, from experimental period data and empirical period-height formulas. The coefficient-based method for low-rise masonry buildings is then calibrated by the published experimental results obtained from shaking table tests. The comparison of the experimental and estimated results indicates that the simplified coefficient-based method can provide good approximations of the maximum spectral accelerations at peak loads of the low-rise masonry reinforced concrete buildings if a proper set of drift factors and initial fundamental vibration periods of structures are used.