• Title/Summary/Keyword: Quick

Search Result 2,952, Processing Time 0.032 seconds

Progress Measurement of Structural Frame Construction using Point Cloud Data (포인트 클라우드 데이터를 활용한 골조공사 진도측정 연구)

  • Kim, Ju-Yong;Kim, Sanghee;Kim, Gwang-Hee
    • Korean Journal of Construction Engineering and Management
    • /
    • v.25 no.3
    • /
    • pp.37-46
    • /
    • 2024
  • Recently, 3D laser scanning technology, which can collect accurate and quick information on phenomena, has been attracting attention among smart construction technologies. 3D laser scanning technology can obtain information most similar to reality at construction sites. In this study, we would like to apply a new member identification method to an actual building and present the possibility of applying point cloud data, which can be collected using 3D laser scanning technology, to measuring progress at construction sites. In order to carry out the research, we collected location information for component identification from BIM, set a recognition margin for the collected location information, and proceeded to identify the components that make up the building from point cloud data. Research results We confirmed that the columns, beams, walls, and slabs that make up a building can be identified from point cloud data. The identification results can be used to confirm all the parts that have been completed in the actual building, and can be used in conjunction with the unit price of each part in the project BOQ for prefabricated calculations. In addition, the point cloud data obtained through research can be used as accurate data for quality control monitoring of construction sites and building maintenance management. The research results can contribute to improving the timeliness and accuracy of construction information used in future project applications.

A Phenomenological Study of Occupational Therapists' Experiences of Transitioning from Adult to Child Occupational Therapy (성인작업치료에서 아동작업치료로 전환한 작업치료사의 임상경험에 관한 현상학적 연구: 감각통합치료 중심으로)

  • Roh, Geummi;Jung, Minye
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.22 no.1
    • /
    • pp.54-68
    • /
    • 2024
  • Purpose : This study aimed to explore the clinical experiences of occupational therapists who have transitioned from adult to child occupational therapy to provide a basis for developing programs to facilitate rapid clinical adjustment for transitioning occupational therapists. Method : Telephone interviews and Colaizzi's phenomenological research method were employed. The interviewees were six occupational therapists with at least three years of clinical experience who had transitioned from hospital-based adult occupational therapy to sensory integration-focused children's occupational therapy. The interviews were recorded, transcribed, and analyzed with the participants' consent. Results : The analysis of the interview transcripts yielded 3 categories, 7 themes, and 17 meanings. The three categories were the challenges facing transitioning occupational therapists in clinical practice, the strengths gained from their post-transition clinical experiences, and the facilitators needed before the transition to ensure quick clinical adjustment. Conclusion : Training and institutional arrangements must be in place to ensure that adult occupational therapists transitioning to sensory integration-focused child occupational therapy can quickly adapt clinically and professionally to their new environments.

A Study on Automatic Bridge Lantern Support for Safe Bridge Lantern Inspection (안전한 교량등 점검을 위한 자동 교량등 지지대에 관한 연구)

  • Min-Yong Lim;Seung-Gi Gug
    • Journal of Navigation and Port Research
    • /
    • v.48 no.4
    • /
    • pp.267-273
    • /
    • 2024
  • Bridge lanterns are installed on bridges or piers to signal the presence of these structures on navigational routes and navigable waters, and they fall under the category of light wave signals in Aids to Navigation. In Korea, medium to large bridges installed over major rivers and seas are equipped with bridge lanterns, which are necessary for routes frequented by ships and require periodic inspections on a monthly or multi-month basis. However, most bridge lanterns are mounted externally on bridge railings as fixed or manual rotary supports, posing a high risk of fatal falls during inspections. Furthermore, high -traffic bridges demand quick maintenance works due to complaints about traffic disruption, thus increasing work hazards. Consequently, this study introduced a tailored automatic bridge lantern support concept based on different types of bridge lantern installations, aiming for safe and rapid inspections. Additionally, the study sought to achieve full automation of the bridge lighting system by integrating it with a management program for monitoring and controlling bridge lanterns, utilizing both wired and wireless communication technologies. These findings provide foundational design data for new and refurbished bridges that will be installed in the future.

Open-ended Coaxial Probe Technique for the Dielectric Characterization of Propylene Carbonate, Dimethyl Carbonate and Their Mixtures from 0.1 to 8 GHz at 288.15, 298.15, and 308.15 K (개방 단말 동축선을 활용한 프로필렌 카보네이트, 디메틸 카보네이트 및 이들의 이성분계 혼합물의 유전 이완 측정과 해석)

  • Hyo Jung Kim;Seung-Wan Song;Tae Jun Yoon
    • Clean Technology
    • /
    • v.30 no.3
    • /
    • pp.228-238
    • /
    • 2024
  • Electrolytes are one of the essential components of a lithium-ion battery. They determine the battery's lifespan and cell characteristics. The dielectric constant is a key thermophysical property for determining how much salt can be dissociated and solvated in a solution. Hence, fast and reliable dielectric constant measurement is essential when formulating an electrolyte solution. This work implemented an open-ended coaxial probe (OECP) station as a quick and reliable tool to measure the complex permittivity spectra of electrolyte solutions. The capability of the OECP station was tested by measuring the complex permittivity of propylene carbonate (PC), dimethyl carbonate (DMC), and their mixtures from 0.1 to 8 GHz at 288.15, 298.15, and 308.15 K. The obtained dielectric spectra were then interpreted based on dielectric relaxation models and thermodynamic theories. The measured static dielectric constant data agreed well with the data from previous studies. They were also correlated using the Wang-Anderko thermodynamic model, showing approximately a 1% deviation from the experimental data. In addition, the relaxation characteristics, including the relaxation time and the Cole-Davidson exponent, showed that the microstructure of the solution significantly changes at the propylene carbonate mole fraction of 0.4. These results and methodologies are expected to contribute to the further understanding of electrolyte solutions and ultimately lead to the optimization of electrolyte formulation for lithium-ion batteries.

Evaluation of a rapid diagnostic kit "BIOLINE RSVTM" for the detection of respiratory syncytial virus (Respiratory Syncytial Virus 감염의 조기 진단 kit "바이오라인 알에스브이TM"의 평가)

  • Kim, So-Hee;Sung, Ji-Yeon;Yang, Mi-Ae;Eun, Byung-Wook;Lee, Jin-A;Choi, Eun-Hwa;Lee, Hoan-Jong
    • Pediatric Infection and Vaccine
    • /
    • v.14 no.1
    • /
    • pp.91-96
    • /
    • 2007
  • Purpose : This study was performed to evaluate a new rapid diagnostic kit (BIOLINE $RSV^{TM}$; Standard Diagnostics Inc., Yongin, Korea), a lateral-flow immunoassay, in the detection of respiratory syncytial virus (RSV) from the nasopharyngeal aspirates (NPA) of children with lower respiratory tract infections (LRTIs) in comparison with other diagnostic methods. Methods : Three hundred and nineteen NPAs were selected from a large pool of NPAs that had been obtained from children with LRTIs. All specimens had already been tested for RSV by culture and immunofluorescent (IF) test, and had been kept frozen. Tests with BIOLINE $RSV^{TM}$ were performed at least twice. All who conducted the experiments or interpreted the test results were blinded to the results of both culture and IF tests. Results : One hundred seven (97.3%) of 110 specimens that were positive for RSV by both culture and IF test, 29 (87.9%) of 33 that were positive by IF test only, 20 (76.9%) of 26 that were positive by culture only, and 140 (93.3%) of 150 that were negative by both methods were negative for RSV by BIOLINE $RSV^{TM}$. By combining the above results, the following 5 diagnostic values of BIOLINE $RSV^{TM}$ were determined in comparison with viral culture or IF test; sensitivity, 92.3% (156/169, 95% confidence interval [CI], 87.1-97.5%); specificity, 93.3% (140/150, 95% CI, 88.4-98.2%); positive predictive value, 94.0% (156/166, 95% CI, 89.5-98.5%); negative predictive value, 91.5% (140/143, 95% CI, 86.0-97.0%); and agreement, 95.9% (306/319, 95% CI, 92.1-99.7%), respectively. Conclusion : This study revealed that BIOLINE $RSV^{TM}$ demonstrated good sensitivity and specificity for the detection of RSV antigen from NPAs of children with LRTIs. Because of simple methods and quick results, this test may be useful for the diagnosis of RSV infection during the epidemic periods.

  • PDF

Multi-residue Pesticide Analysis in Cereal using Modified QuEChERS Samloe Preparation Method (곡물류 중 잔류농약 다성분 분석을 위한 개선된 QuEChERS 시료 정제법의 개발)

  • Yang, In-Cheol;Hong, Su-Myeong;Kwon, Hye-Young;Kim, Taek-Kyum;Kim, Doo-Ho
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.4
    • /
    • pp.314-334
    • /
    • 2013
  • This study explored an efficient modified Quick, Easy, Cheap, Effective, Rugged and safe (QuEChERS) method combined with liquid chromatography-electrospray ionization with tandem mass spectrometric detection for the analysis of residues of 76 pesticides in brown rice, barley and corn including acidic sulfonylurea herbicides. Formic acid (1%) acid in acetonitrile and dispersive solid phase extractions used for extraction of pesticides and clean-up of the extract respectively. Two fortified spikes at 50 and 200 ng $g^{-1}$ levels were performed for recovery test. Mean recoveries of majority of pesticides at two spike levels ranged from 73.2 to 132.2, 80.9 to 136.8, 66.6 to 143.5 for brown rice, barley and corn respectively with standard error (CV) less than 10%. Good linearity of calibration curves were achieved with $R^2$ > 0.9907 within the observed concentration ranged. The modified method also provided satisfactory results for sulfonylurea herbicides. The method was applied to the determination of residues of target pesticides in real samples. A total of 26 pesticides in 36 out of 98 tasted samples were observed. The highest concentration was observed for tricyclazole at 1.17 mg $kg^{-1}$ in brown rice. This pesticide in two brown rice samples exceeded their MRLs regulated for rice in republic of Korea. Except tricyclazole none of the observed pesticides' concentration was higher than their MRLs. The results reveal that the method is effectively applicable to routine analysis of residues of target pesticides in brown rice, barley and corn.

The correlation between dental compensation and craniofacial morphology in skeletal Class III malocclusion (골격성 III급 부정교합자의 치성보상과 두개안면골격의 상관관계에 관한 연구)

  • Jeon, Young-Jin;Park, Su-Byung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.209-219
    • /
    • 1997
  • This investigation was designed to analyze the degree of dental compensation according to horizontal components of craniofacial skeleton and to investigate correlation between dental compensation and craniofacial pattern in skeletal class III malocclusion. The material selected for this study consisted of standard lateral cephalogram of 59 subjects in normal occlusion group, 91 subjects in mild skeletal class III malocclusion group and 58 subjects in severe skeletal class III malocclusion group. The mild skeletal class III malocclusion group was divided into two groups, one was class III malocclusion without anterior crossbite group and the other was class III malocclusion with anterior crossbite group. The data were analyzed by Quick-ceph image program. The results were as follows. 1. Mild skeletal class III malocclusion without anterior crossbite group showed the most labial inclination of upper incisors, followed by severe skeletal class III malocclusion group and mild skeletal class III malocclusion with anterior crossbite group, the Latter showing the least. The amount of lingual inclination of lower incisors was the largest in severe skeletal class III malocclusion group, and there was no statistically significant difference between mild skeletal claw III malocclusion without anterior crossbite group and mild skeletal class III malocclusion with anterior crossbite group. 2. There were little differences in vertical skeletal structure between mild skeletal class III malocclusion without anterior crossbite group and mild skeletal class III malocclusion with anterior cwssbite group, they showed statistically significant differences in the upper incisors measurements. 3. The measurements of lower incisors in mild skeletal class III malocclusion without anterior crossbite group and upper incisors in mild skeletal class III malocclusion with anterior crossbite group represented a high correlation with skeletal structure. Especially, ∠IMPA and ∠FMIA of lower incisor measurements, and ∠U1-FH ∠U1-SN of upper incisor measurements showed high correlation with skeletal structure in each group. 4. ∠IMPA and ∠FMIA of lower incisor measurements showed high correlation with skeletal structure in all groups. ∠U1-FH, ∠U1-SN and U1-facial plane(mm) of upper incisor measurements represented higher correlation with skeletal structure than any other upper incisor measurements.

  • PDF

Implementation of An Automatic Authentication System Based on Patient's Situations and Its Performance Evaluation (환자상황 기반의 자동인증시스템 구축 및 성능평가)

  • Ham, Gyu-Sung;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.21 no.4
    • /
    • pp.25-34
    • /
    • 2020
  • In the current medical information system, a system environment is constructed in which Biometric data generated by using IoT or medical equipment connected to a patient can be stored in a medical information server and monitored at the same time. Also, the patient's biometric data, medical information, and personal information after simple authentication using only the ID / PW via the mobile terminal of the medical staff are easily accessible. However, the method of accessing these medical information needs to be improved in the dimension of protecting patient's personal information, and provides a quick authentication system for first aid. In this paper, we implemented an automatic authentication system based on the patient's situation and evaluated its performance. Patient's situation was graded into normal and emergency situation, and the situation of the patient was determined in real time using incoming patient biometric data from the ward. If the patient's situation is an emergency, an emergency message including an emergency code is send to the mobile terminal of the medical staff, and they attempted automatic authentication to access the upper medical information of the patient. Automatic authentication is a combination of user authentication(ID/PW, emergency code) and mobile terminal authentication(medical staff's role, working hours, work location). After user authentication, mobile terminal authentication is proceeded automatically without additional intervention by medical staff. After completing all authentications, medical staffs get authorization according to the role of medical staffs and patient's situations, and can access to the patient's graded medical information and personal information through the mobile terminal. We protected the patient's medical information through limited medical information access by the medical staff according to the patient's situation, and provided an automatic authentication without additional intervention in an emergency situation. We performed performance evaluation to verify the performance of the implemented automatic authentication system.

Comparison of crown designs of different dental occupational groups, using CAD-CAM (CAD-CAM을 이용하여 디자인한 금관의 치과 직업군에 따른 형태 비교)

  • Kim, TaeHyeon;Kim, Jong-Eun;Lee, Ah-Reum;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.234-238
    • /
    • 2016
  • Purpose: Increasing use of computer aided design-computer aided manufacturing (CAD-CAM) system and number of design software made design of restoration easy and quick. Outcome of restoration has been dependent on dental technician's wax up proficiency, dentists can design restoration for themselves now. This study aims to investigate the outcome of restoration designs, according to handling skill of CAD-CAM design tool. Materials and methods: A patient's mandibular right 1st molar was prepared. After taking impression, stone model was made, scanned the stone model with 3 shape intra-oral scanner, stereolithography (STL) file was extracted. With 3shape dental designer, one dental technician with more than 5 years work experience (designer 0) and three dental technicians with less than 2years work experience (designer 1, 2, 3-group DT) and 4 1st year residents (designer 4, 5, 6, 7-group RT) designed gold crown on the same STL file. Designed crown's MD (mesio-distal) and BL (bucco-lingual) diameter, height of crown, inter-cuspal distance, number of occlusal contact points were compared. Statistical analysis was carried out, test of normality within each group, using independent t-test. Number of contact points were compared, using Wilcoxon signed-rank test. Results: There was no significant difference between group DT and group RT. Number of contact points also resulted in no significant difference. Conclusion: The outcome of each designed crowns showed no statistical differences, in values which can be expressed as numbers. Subjective factors were different. With increasing proficiency in handling designing software, fabrication of restorations according to each designer's occlusal concept can be made easy.

Effect of Light-Induced ROS Generation Unit on Inactivation of Foodborne Pathogenic Bacteria in Water (광유도 ROS 발생장치의 세척용수 중 식중독 세균에 대한 불활성화 효과)

  • Choi, Jaehyuk;Kim, Dawoon;Jung, Kyu-Seok;Roh, Eunjung;Ryu, Kyoung-Yul;Ryu, Jae-Gee
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.583-590
    • /
    • 2019
  • As the consumption of fresh fruits and vegetables increases, food poisoning caused by foodborne pathogen contamination is not decreasing. To prevent the contamination of produce, a quick and easy, low-cost, environmentally-safe disinfection method that does not affect produce freshness or quality is needed. This study demonstrates a new-concept, circulating-water disinfection system that purifies water by using newly developed 'LED-PS (photosensitizer)-induced ROS generation unit'. Using various types of LED-PS induced ROS generation units, we investigated the conditions for reducing the density of various pathogenic bacteria by more than 3 log CFU / mL in 1 hour. The major operational factors affecting the density reduction of the LED-PS-induced ROS generation unit were analyzed. Depending on bacteria species, the density reduction rate was varied. The effect of the units on reducing the density of Bacillus cereus and Pectobacterium carotovorum subsp. carotovorum was high, but the effect on foodborne bacteria such as Escherichia coli was relatively low. In this circulating water disinfection system, the density reduction effect tended to increase as the flow rate increased and the initial bacterial density decreased. As the amount of PS absorbed beads increased, the density reduction effect increased exponentially in some bacteria. Model 3280, a double cylindrical unit connecting two single cylindrical units, could completely sterilize more than 3 log CFU/mL of B. cereus and P. carotovorum subsp. carotovorum in 30 minutes of LED irradiation.