• Title/Summary/Keyword: Quench characteristics

Search Result 220, Processing Time 0.032 seconds

Quench Protection System for the KSTAR Toroidal Field Superconducting Coil

  • Lee, Dong-Keun;Choi, Jae-Hoon;Jin, Jong-Kook;Hahn, Sang-Hee;Kim, Yaung-Soo;Ahn, Hyun-Sik;Jang, Gye-Yong;Yun, Min-Seong;Seong, Dae-Kyoung;Shin, Hyun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.178-183
    • /
    • 2012
  • The design of the integrated quench protection (QP) system for the high current superconducting magnet (SCM) has been fabricated and tested for the toroidal field (TF) coil system of the Korea Superconducting Tokamak Advanced Research (KSTAR) device. The QP system is capable of protecting the TF SCM, which consists of 16 identical coils serially connected with a stored energy of 495 MJ at the design operation level at 35.2 kA per turn. Given that the power supply for the TF coils can only ramp up and maintain the coil current, the design of the QP system includes two features. The first is a basic fast discharge function to protect the TF SCM by a dump resistor circuit with a 7 s time constant in case of coil quench event. The second is a slow discharge function with a time constant of 360 s for a daily TF discharge or for a stop demand from the tokamak control system. The QP system has been successfully tested up to 40 kA with a short circuit and up to 34 kA with TF SCM in the second campaign of KSTAR. This paper describes the characteristics of the TF QP systems and test results of the plasma experiment of KSTAR in 2009.

Equal Quench and Endurance Test of the BSCCO Superconducting Fault Current Limiter (BSCCO 초전도 한류기의 동시퀜치 및 내력 시험)

  • Sim, Jung-Wook;Park, Kwon-Bae;Lee, Bang-Wook;Oh, Il-Sung;Yim, Sung-Woo;Kim, Hae-Rim;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.933-934
    • /
    • 2007
  • We fabricated and tested a resistive type superconducting fault current limiter (SFCL) based on BSCCO-2212 bulk coils. Each bulk coils of the SFCL was designed to have the rated voltage of 220 $V_{rms}$ and the critical current($I_C$) of 320$\sim$340 A at 77K. Ten components in series, make the SFCL having the rated voltage of 2.2 $kV_{rms}$ for equal quench test. The fault test was conducted at an input voltage of 2.2 $kV_{rms}$ and fault current of 25 $kA_{rms}$. In addition, we examined the endurance characteristics for all bulk coils through repeat fault test. Test results shows that the SFCL successfully limited the fault current of 25$kA_{rms}$ to below $7{\sim}8kA_{p}$ within minimum 1.1msec after fault occurred. All bulk coils quenched together upon faults and shared the rated voltage evenly. The endurance test results show an equivalent among repeat fault test. During the quench process, average temperature of all bulk coils did not exceed 250 K, and the SFCL was totally safe during the whole operation.

  • PDF

Analysis on Current Limiting and Recovery Characteristics of a SFCL using a Trigger of Superconducting Element (초전도소자의 트리거를 이용한 초전도 전류제한기의 전류제한 및 회복특성 분석)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.112-116
    • /
    • 2010
  • As one of the countermeasures to improve the recovery characteristics of the SFCL (superconducting fault current limiter), the method using the trigger of high-TC superconducting element (HTSC) when the quench in the HTSC element occurred was proposed. To confirm the suggested method, the control circuit to detect the quench occurrence of HTSC element in case of the fault occurrence was designed and the current limiting and recovery experiments of the SFCL using the designed control circuit were performed. Through the analysis for the experimental results, the points of both the open time and the closing time of a power switch comprising the control circuit could be adjusted by the resistance amplitude of a normal conducting current limiting resistor (CLR) and the recovery characteristics of the SFCL together with the current limiting operation could be confirmed to be improved by using the control circuit.

The Fault Current Limiting Characteristics According to Increase of Voltage in a Flux-Lock Type High-Tc Superconducting Fault Current Limiter (전압 증가에 따른 자속구속형 고온 초전도 전류제한기의 사고전류 제한 특성)

  • Cho, Yong-Sun;Park, Hyoung-Min;Lim, Sung-Hun;Park, Chung-Ryul;Han, Byoung-Sung;Choi, Hyo-Sang;Hyun, Ok-Bae;Hwang, Jong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.93-96
    • /
    • 2004
  • In this paper, we analyzed the current limiting characteristics according to increase of source voltage in the flux-lock type high-Tc superconducting fault current limiter (SFCL). The flux-lock type SFCL consisted of two coils, which were wound in parallel each other through an iron core, and high-Tc superconducting (HTSC) element connected with coil 2 in series. The flux-lock type SFCL has the characteristics better in comparison with the resistive type SFCL because the fault current in the flux-lock type SFCL can be divided into two coils by the inductance ratio of coil 1 and coil 2. The fault current limiting operation of the flux-lock type SFCL can be different due to winding direction of the two coils. The winding method where the decrease of linkage flux between two coils in the accident happens is called the subtractive polarity winding and the winding method in case of the increase of linkage flux is called the additive polarity winding. The fault current limiting experiments according to the source voltage were performed for these two winding methods. Through the comparison and the analysis of the experimental data, we confirmed that the quench time was shorter, irrespective of the winding direction as the source voltage increased and that the fault current and the HTSC's resistance increased as the amplitude of the source voltage increased. The additive polarity winding made the fast quench time and the lower resistance of HTSC element in comparison with the subtractive polarity winding. The fault current of the subtractive polarity winding was larger than that of the additive polarity winding. In conclusion, we found that the additive polarity winding reduced the burden of SFCL because the quench time was shorter and the fault current was smaller than those of the subtractive polarity winding.

  • PDF

A Study on the Quench Propagation Properties of Bi-2223 Wire cooled in Liquid Nitrogen (액체질소로 냉각된 Bi-2223 선재의 퀜치 전파 특성에 관한 연구)

  • Yoon Kyung Yong;Bae Duck Kweon;Ahn Min Cheol;Kang Hyung Ku;Lee Chan Joo;Yoon Yong Soo;Lee Sang Jin;Ko Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.1
    • /
    • pp.32-36
    • /
    • 2005
  • With the successful commercialization of Bi-2223 powder-in-tube wire , various attempts in the R & D of the high-Tc superconducting (HTS) magnets for high magnetic field applications are being implemented actively. Operating temperature of HTS magnet has to be maintained at the designed level but the magnetic energy and mechanical disturbance can cause unstable operational temperature of HTS magnet. Especially the generated heat energy of inner HTS winding Is apt to be accumulated . so the normal region appears in HTS winding. This paper deals with the quenching characteristics of three kinds of selected Bi-2223 wires : the High Current Density Wire (HC-A) and the High Strength Wire (HS-A) made by AMSC and HTS wire(HW-I) made by Innost The Innost wire has the highest minimum quench energy (MQE). The High Current Density Wire has the highest normal zone Propagation velocity (NZPV).

A Characteristics of Large Current and Minimum Quench Energy on Prototype High-$T_c$ Superconducting Cable (Prototype 고온초전도 케이블의 최소 Quench에너지 및 대전류 특성)

  • Kim, Sang-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.236-242
    • /
    • 2000
  • NZP velocities were investigated on Ag sheathed multi filamentary Bi-2223 tape and direction type HTS cable. The critical current($I_c$) of Ag sheathed Bi-2223 tape and direction type HTS cable were 12 A, 63 A at 77 K, 0 T. NZP velocities of tape with two condition of DC and AC were almost same at each temperature. In case of DC, the NZP velocities of numerical analysis and experiment were almost same. NZP velocities of direction type HTS cable were 1.9-2.4 cm/sec. The result shows that the total transport current of spiral type HTS cable in $LN_2$ was 475[A], and transport current passed through almost the outer layer (2-layer). Also, AC transport losses in outer layer of HTS cable was proportion to $I^2$ and higher than losses of inner layer. And in case of $I_p=I_c$, calculated numerical loss density was concentrated on the edge of tape and most of loss density in cable was distributed outer layer more than inner layer.

  • PDF

Characteristics of 15 kVA superconducting fault current limiter (15 kVA급 저항형 초전도 한류기의 전류제한특성)

  • Choi, Hyo-Sang;Kim, Hye-Rim;Hwang, Si-Dole;Kim, Sang-Joon;Lim, Hae-Ryong;Kim, In-Seon;Hyun, Ok-Bae
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.272-275
    • /
    • 2000
  • We investigated a resistive superconducting fault current limiter (SFCL) fabricated using YBCO thin films on 2-inch diameter sapphire substrates. Nearly identical SFCL units were prepared and tested. The units were connected in series and parallel to increase the current and voltage ratings. A serial connection of the units showed significantly unbalanced power dissipation between the units. This imbalance was removed by introducing a shunt resistor to the firstly quenched unit. Parallel connection of the units increased the current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current 25 Ap, was produced and successfully tested at a 220 V circuit. From the resistance increase, we estimated that the film temperature increases to 200 K in 5 msec, and 300 K in 120 msec. Successive quenches revealed that this system is stable without degradation in the current limiting capability under such thermal shocks as quenches at 220 V.

  • PDF

Development of new current path pattern of YBCO thin films for Superconducting fault current limiters (초전도 한류기용 YBCO 박막 전류 Path Pattern 개발)

  • Lee B. W.;Kang J. S.;Park K. B.;Oh I. S.
    • Progress in Superconductivity
    • /
    • v.6 no.2
    • /
    • pp.113-117
    • /
    • 2005
  • In this study, electromagnetic analysis of current paths including meander pattern, spiral pattern, and bi-spiral pattern were performed and in order to verity the analysis results, experiments tests including quench test, and insulation tests were performed. In addition, bubble corner concepts were introduced to enhance insulation reliability. From our study, bi-spiral pattern of YBCO thin films were rather effective for quench and insulation than the other patterns. So this current path pattern was adopted for YBCO thin films in order to develop 6.6 kV resistive fault current limiters. Finally YBCO thin films were connected in series and parallel to enhance capacity, and the test results of current limiting characteristics of 6.6kV resistive SFCL were successful. The Progress in Superconductivity is published every six month and serves as a channel for publications on superconductivity and related topics. The author(s) are required to submit THREE copies of the manuscripts along with original figures directly to the Editor.

  • PDF

Improvement of Quench Properties of a Flux-Lock Type Superconducting Fault Current Limiter by the Connection Method of YBCO Elements (YBCO소자의 연결방법에 의한 자속구속형 초전도 한류기의 퀜치특성의 향상)

  • Chung, Soo-Bok;Park, Hyoung-Min;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.323-327
    • /
    • 2008
  • We investigated the quench characteristics of a flux-lock type superconducting fault current limiter (SFCL) depending on the methods of the serial and parallel connections between the superconducting elements. The flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil through an iron core, and the secondary coil is connected to the superconducting elements in series and parallel. In this paper, the analyses of voltage, current, and resistance of the superconducting elements connected in serial and parallel were performed to increase the power capacity of the flux-lock type SFCL. A part of the superconducting elements was not quenched in $2{\times}2$ serial connection between the elements and then the power burden of the quenched elements was increased. However the elements with $2{\times}2$ parallel connection was all quenched. This means that the power burden of each superconducting element can be reduced under the same conditions. We found that $2{\times}2$ parallel connection was more profitable for the current limiting effects and the increase of the power capacity.

Evaluation of a model coil characteristics for HTS rotating machine using conduction-cooled (전도 냉각을 이용한 고온 초전도 회전기용 모델 코일의 특성 평가)

  • Lee, J.D.;Baik, S.K.;Sohn, M.H.;Lee, E.Y.;Kim, Y.C.;Kwon, Y.K.;Park, M.W.;Yu, I.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.725-726
    • /
    • 2006
  • In large scale superconducting rotating machine, HTS field coils are constructed with many stacks of single or double pancake coils connected in series. In spite of its higher thermal stability, HTS field coil experiences some quench, which results in some part of burn-out in the field coils. Thus in the view point of the HTS rotating machine field coil design and testing, it was very important to predict the possibility of quench occurrence in the designed field coils. In this paper, a HTS racetrack coil constructed with two single pancake coils and one double pancake coil was tested in LN2 and cooling by GM refrigerator. It is wound using the Bi-2223 tape. The experimental details and results are presented in this paper.

  • PDF