A study on the quantity of shear-wall by seismic retrofit of wall-type apartment (벽식 아파트 내진보강을 위한 신설벽체 벽량에 관한 연구)

  • Jung, Woo-Kyung;Hong, Geon-Ho;Song, Jin-Gyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.169-172
    • /
    • 2006
  • Wall construction apartment built before 1988 years need internal examination reinforcement according to existing laws ans regulations at remodeling because do not earthquake resistant design. Established newly wall to interest paid back at the same time a the principal direction for wall construction apartment internal examination reinforcement, and satisfied internal examination standard because uses width displacement between floor. This study analyzes displacement value such as latitude and presented position of efficient reinforcement wall and wall quantity at earthquake resistant design of wall construction apartment.

  • PDF

A Study for Automated Division of Composite Walls for Quantity Take-off in Construction Document Phase (실시설계단계에서 수량산출을 위한 복합벽체 자동분할에 관한 연구)

  • Park, Seunghwa;Kim, Heungsoo;Yoon, Dooyung
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.2
    • /
    • pp.124-132
    • /
    • 2015
  • When Building Information Modeling (BIM) was introduced at the early stage, it was only utilized as a three-dimensional visualization tool. Nowadays, however, BIM is being studied for increasing design productivity and managing enormous information on building life cycle. One of the representative research is developing 'common prototype BIM libraries'. BIM data made of common prototype libraries should be utilized in various ways, quantity takeoff, code checking, energy analysis and so on. However, common prototype BIM libraries are not enough to estimate accurate cost. For example, composite wall libraries should be divided into several single objects, wall structure and finishes, for the quantity takeoff and construction cost calculation. In this paper, we are suggesting an automated division algorithm of composite wall and developing a system prototype for it. This study is expected to reduce extra modeling work and contribute to fast and accurate cost calculation in the construction.

Selection of the Large Diameter Pipe Wall Thickness by Value Engineering for a Plant (플랜트에서 가치공학 개념을 적용한 대관경 배관두께 선정에 관한 연구)

  • Choi, Gayoung;Yoo, Hoseon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.7 no.3
    • /
    • pp.65-73
    • /
    • 2011
  • This research has suggested a method to select pipe wall thickness by application of the value engineering to reduce the cost and quantity that are major part of construction materials. This research shows that the application of value engineering reduces the cost of piping materials by optimizing pipe wall thickness while maintaining process flow date of design pressure and design temperature. Based on this knowledge, the application of the value engineering will lead to the cost reduction and quantity reduction by effective selection of pipe wall thickness. The application of the value engineering will help the EPC companies to win a contract in the overseas plant market.

  • PDF

The study of using living room furniture in the apartment size for the common people (국민주택규모 APT 거실의 가구사용에 관한 연구)

  • 이명옥
    • Journal of the Korean Home Economics Association
    • /
    • v.30 no.2
    • /
    • pp.87-95
    • /
    • 1992
  • This study attempts to fix an appropriate quantity of space evaluation, focusing on important furniture room visual environment elements. The major results of the study can be summarized as follows; 1. The degree of satisfaction in the living room is affected by an evaluational factor among factors of space evaluation. 2. In the space estimation for the furniture, the wall furniture is important in the living room because the arragement and occupying proportion of the wall furniture varies widely. 3. In the living room of the APT siza for the common people an appropriate quantity of furniture is classified into 3 types of the occuppying proportion. As the floor occupancy proportion supporting furniture is 13~19%, wall furniture is 10~16% and total furniture which combined both the supporting furniture and the wall furniture is 23~34%. Second, the proportion occupying the wall is 6~9% for the supporing furniture, 9~20% for the wall furniture, and 21~31% for the total furniture. Finaly the proportion occupying the space is 6~9% for the supporting furniture, 9~20% for the wall furniture, and 21~31% for the total furniture. Finaly the proportion occupying the space is 6~9% for the supporting, 6~10% for the wall furniture, and 11~16% for the total furniture.

  • PDF

Origin of the Initial Permeabiliy of Ni0.8-xZn0.2CoxFe2O4+δ Ferrite (Ni0.8-xZn0.2CoxFe2O4+δ조성 페라이트의 투자율 변화 기구)

  • 안용운;김종령;오영우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.1
    • /
    • pp.46-51
    • /
    • 2004
  • The cause for the variation of the initial permeability according to the Co substitution of Ni-Zn ferrite used in the LC resonance filter for the power line communication is studied. The initial permeability decreases as the quantity of Co diminishes, and the saturation magnetization increases as the quantity increases. Because the sintering density and the microstructure of ferrite show little change, the variation of the initial permeability can't be explained by the density, microstructure nor the saturation magnetization factor. The magnetocrystalline anisotropy increases, similar with the saturation magnetization, as the quantity of Co increases. The increase of magnetocrystalline anisotropy value makes the domain wall energy grow, which leads to the decrease of the initial permeability, because there's linear law between the magnetocrystalline anisotropy and the domain wall energy. The resonance frequency to Co substitution moved to high frequency band, due to the close relationship with domain wall energy, Initial permeability decreaed a little with an increase of Co contents, but resonace frequency moved to high frequency band. as a result of that, when Co was added 0.05 mol, initial permeability and resonace frequency was 75 and 25 MHz respectively.

Quantity Estimation Method for High-Performance Insulated Wall Panels with Complex Details Using BIM Family Libraries (BIM의 패밀리 라이브러리를 이용한 복잡한 상세를 갖는 고단열 벽체 판넬의 물량 산출 방법)

  • Mun, Ju-Hyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.4
    • /
    • pp.447-458
    • /
    • 2024
  • This study investigates the effectiveness of Building Information Modeling(BIM) software, specifically SketchUp and Revit, in reducing errors during quantity take-off(QTO) for complex building elements. While 3D modeling offers advantages, existing software may not fully account for manufacturing discrepancies, such as variations in concrete cover thickness and reinforcing bar radius. To address this limitation, this research proposes a BIM-based QTO method for high-insulation wall panels with intricate details. The method utilizes a BIM family library, focusing on key parameters like concrete cover thickness and inner radius of shear reinforcement. A case study compared the cross-sectional details of a wall panel modeled in Revit with the actual manufactured specimen. The analysis revealed a 12% reduction in modeled concrete cover thickness and a 1.27 times larger modeled inner radius of the shear bar compared to the real-world values. The proposed method incorporates these manufacturing variations into the Revit model of the high-insulation wall panel. Software like Navisworks facilitates the identification and correction of any material interferences arising from these adjustments. Furthermore, the method employs a unit wall concept(1m2) to account for the volume of various materials, including insulation and splice sleeves at joints. This allows for the identification of a similar existing family within the BIM library(e.g., "Double RC wall with embedded insulation") that reflects the actual material quantities used in the wall panel. By incorporating these manufacturing-induced variations, the proposed method offers a more accurate QTO process for complex high-insulation wall panels. The "Double RC wall with embedded insulation" family within the Revit program serves as a valuable tool for material quantity estimation in such scenarios.

Influence of reset pulse form on electrical characteristics in AC-PDP

  • Cho, T.S.;Ko, J.J.;Lee, C.W.;Cho, G.S.;Choi, E.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.159-161
    • /
    • 2000
  • After the square type reset pulse, the condition of remaining wall charge has been experimentally investigated in AC-PDP with VDS (Versatile Driving Simulator) system, in which arbitrary driving waveform and sequence can be used. After the self-discharge process, almost wall charges are eliminated. But some wall charges are not and its quantity is dependent on the voltage of the reset pulse. When the voltage of the reset pulse is growing, its quantity is decreased. But if the voltage of the reset pulse is above 300V, the wall voltage due to remaining wall charge is constant and its value is found out 6V. Also it is found that its polarity is always same with the one made by the reset pulse. It means that the polarity is not changed by the self-discharge.

  • PDF

An experimental study on performance comparison of waterproof concrete using admixture and penetrability waterproof admixture of concrete (구체방수와 침투성방수의 방수성능 비교에 대한 실험적 연구)

  • Park, Ki-Woo;Oh, Sang-Geun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.229-230
    • /
    • 2011
  • We could see that, the thinner the retaining wall is, the more advantageous Premixed Agent Type Waterproof method is in the aspect of economic efficiency. The reason is because, in the case of Premixed Agent Type Waterproof method, the thicker the retaining wall is, the higher the construction cost increases due to increase in the material quantity required which increases in proportion to the area in the case of Premixed Agent Type Waterproof method. We could see that, the thinner the retaining wall is, the more inferior the economic efficiency of Infiltration Type Waterproof method is to that of Premixed Agent Type Waterproof method, as, in the case of Infiltration Type Waterproof method, the quantity of material required is fixed in proportion to the area. Consequently, we concluded that Premixed Agent Type Waterproof method is economically advantageous up to the wall thickness of 700 mm and Infiltration Type Waterproof from 800 mm.

  • PDF

Effect by reinforcement wall position for apartment remodeling (아파트 리모델링을 위한 보강벽체 위치에 따른 영향)

  • Jung, Woo-Kyung;Hong, Geon-Ho;Song, Jin-Gyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.354-357
    • /
    • 2006
  • Recently, remodeling of the reinforced concrete apartment became hot issue of the housing policy in Korea. In Korea, the seismic design regulation has been revised since it was established in 1988 first, in order to minimize the economic losses. It has studied that the apartments that built in 1980's and their new remodeling for seismic performance. Also lateral displacement of remodeling analysis about variation of shear-wall for apartment on the architetural remodeling. Position change by wall quantity is state that study about efficient guide line about apartment wall quantity changed at remodeling because it is factor that can influence on motion of whole building is insufficient.

  • PDF

Development of material for a Light weight partition wall using material of Gypsum (석고 재료를 이용한 경량칸막이 벽체 소재 개발에 대한 연구)

  • 박준철;윤요현;류희정;최영준;김화중
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.134-137
    • /
    • 2000
  • A study on the development of material for a light weight partition wall using material of gypsum and waste paper is be considered to improve workability, setting time, properties of strength by use of $\beta$-Gypsum for controling setting time. According th the experiments, as quantity of gypsum in binder increase, workability and strength of specimens deteriorate. Appropriate quantity of $\beta$-Gypsum was 3~6% of binder and When it was used more than 10%, setting time was so fast. When additive quantity of waste paper has increased to 1%, flexural strength decreased to some 8~12% and density decreased abort 3% in comparison with otherwise specimen.