• Title/Summary/Keyword: Quantity of drainage

Search Result 72, Processing Time 0.024 seconds

COMPARATIVE STUDY ON DEWATERING SLUDGE WITH SOLAR DRYING AND SIPHON METHODS

  • Tong, Jun;Yasufuku, Noriyuki;Omine, Kiyoshi;Kobayashi, Taizo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09c
    • /
    • pp.125-128
    • /
    • 2010
  • A large quantity of purified water sludge is generated in modern cities around the world. Dewatering is essential to reduce the volumes transported off-site for disposal. Traditionally employed methods such as solar drying methods are time-consuming. There are urgent demands for developing alternatives to dewater the sludge in a less time-consuming manner. In this paper, siphon method is proposed to dewater the high-water-content sludge with plastic drainage plate installed horizontally. A group of comparative tests are conducted to preliminarily investigate the dewatering behavior of the purified water sludge with siphon and solar drying methods, respectively. On the basis of the test results, the availability and effectiveness of the new method is verified. It may provide an innovative solution to treat the purified water sludge more effectively.

  • PDF

The Characteristics on Compressive Strength of Mixed Coal Ash in Ash Pond (회사장 혼합석탄재의 압축강도 특성)

  • Koh, Yongil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.11
    • /
    • pp.61-66
    • /
    • 2014
  • The various recycling methods of mixed coal ash have been developed considerably and it's recycling quantity has been increased. However, the more relatively finer grain content of coal ash in ash pond is increased the more it's quantity is increased in recycling as products for drainage in soft ground etc. Accordingly, the geotechnical properties of mixed coal ash in ash pond would be inferior and it's recycling rate should reach the limitations in increase. In this study, to recycle mixed coal ash contained fine grain in considerably amount as products for strength, etc. By adding binder to it and manifesting, it's compressive strength is stronger than the criteria, these are suggested; 1) the variety of compressive strength test performed on mixed coal ash of various grain distributions as main material, 2) the kind of binder, it's mixing quantity and the optimum content rate range of fine grain coal ash that the compressive strength stronger than a certain compressive strength is manifested. Cement is more excellent than quicklime as binder in manifesting stronger compressive strength and the sieve type to sort it is #40 sieve in order to recycle all mixed coal ash in ash pond efficiently as products for drainage as well as products for strength, etc. And, it could increase insufficient compressive strength remarkably that content of pure sand is more in the rate as pure sand and the part of mixed coal ash in ash pond to pass through #40 sieve is mixed in the ratio of 2 to 8.

The Classification of Dam Heightening Reservoir using Factor and Cluster Analysis (논문 - 인자 및 군집분석을 이용한 둑 높이기 저수지 유형분류에 관한 연구)

  • Kim, Hae-Do;Lee, Kwang-Ya;Jung, In-Kyun;Jung, Kwang-Wook;Kwon, Jin-Wook
    • KCID journal
    • /
    • v.18 no.2
    • /
    • pp.66-75
    • /
    • 2011
  • Multivariate statistical analysis was applied to 110 dam heightening reservoir to classify the building conditions for waterfront centered around cultivated area using data of land cover, landscape, additional water quantity, local economic, tourism resources, and accessibility related variables. Five factors were extracted through factor analysis based on eigen value criteria of more than one. These five factors together account for 68.2% of the total variance. Characteristics of five factors for the downstream of dam heightening reservoirs are building conditions of waterfront, economic conditions, additional water quantity, eco-tours, and accessibility of tourism resources respectively. Five clusters were classified through cluster analysis based on factor score. The classified result shows that third cluster has remunerative terms for building waterfront.

  • PDF

A Study on Use and improvement of Construction type infiltration gallery (조립식 집수암거의 개량과 이용에 관한 연구)

  • 함준호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.14 no.2
    • /
    • pp.2593-2602
    • /
    • 1972
  • Plastic pipes Wrapped with synthetic filter are recently used for drainage or Collecting of Underground water. But it's use is possible only for small size of diameter less than 300mm, because large size plastic pipes are not readily availabe. For large diameter infiltration gallery, porous concrete pipes are now used, but it's heavy weight brings difficulties in making, moving and setting of the pipes. With it's conventional method of filter setting, fine sands are brought into the pipes to make trouble to lifting pumps and channels Therefore, initial construction cost and maintenance cost become high. To solve-this problem, new method is developed and tested. Small PVC pipes(diameter 14mm) are assembled at the site of construction to newly devised I beam type circls. The size of circular inpiltration gallery is optionally determined by I beam type circle which support small PVC pipes and is made of PVC amterial. This gallery are wrappd with syntheitc filter to prevent sand instruction. In this test, the diameter of 300, 400, 500mm were used. I beam type circles were made with PVC plated with thickness. t=6, 9, 12mm. Water quantity collected through the PVC circulor gallery are measured and the strengths of the gallery. 1. Allowable setting depth of gallery pipe below graund for the case of t=6mm, D=500mm is 2.72m. 2. Collected water quantity depends on soil texture, depth of water grandient of water surface, filter material angle of setting etc. 3. About 126% of water quantity collected from the one gallery pipe measured in two gallery pipes of two parallel installation.

  • PDF

Effect of infiltration/inflow by rainfall for sewerage facilities in the area with partially separate sewer system (불완전 분류식 하수처리구역의 강우에 의한 하수도시설의 침입수/유입수 영향 분석)

  • Shin, Jungsub;Han, Sangwon;Yook, Junsu;Lee, Chungu;Kang, Seonhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.3
    • /
    • pp.177-190
    • /
    • 2019
  • The purpose of this study was to analyze the effects of sewerage facilities through I/I analysis by rainfall by selecting areas where storm overflow diverging chamber is remained due to the non-maintenance drainage equipment when the sewerage system was reconstructed as a separate sewer system. Research has shown that wet weather flow(WWF) increased from 106.2% to 154.8% compared to dry weather flow(DWF) in intercepting sewers, and that the WWF increased from 122.4% to 257.6% in comparison to DWF in storm overflow diverging chamber. As a result, owing to storm overflow diverging chamber of partially separate sewer system with untreated tributary of sewage treatment plant, rainfall-derived infiltration/inflow(RDII) has been analyzed 2.7 times higher than the areas without storm overflow diverging chamber. Meanwhile, infiltration quantity of this study area was relatively higher than that of other study areas. Therefore, it is necessary to reduce infiltration quantity through sewer pipe maintenance nearby river. Drainage equipment maintenance should be performed not to operate storm overflow diverging chamber in order to handle the appropriate sewage treatment plant capacity for rainfall because it is also expected that RDII due to rain will occur after maintenance. In conclusion, it is necessary to recognize aRDII(allowance of rainfall-derived infiltration/inflow) and to be reflected it on sewage treatment plant capacity because aRDII can occur even after maintenance to the complete separate sewer system.

Analysis of Flow Duration and Estimation of Increased Groundwater Quantity Due to Groundwater Dam Construction (지하댐 건설로 인한 지하수 증가량 계산 및 유황 분석)

  • Kim, Jong-Tae;Kim, Gyoo-Bum;Chung, Il-Moon;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.24 no.1
    • /
    • pp.91-98
    • /
    • 2014
  • This paper aims to calculate the increase in groundwater quantity following groundwater dam construction, and to assess its impact on surface water. In the study area of Osib-cheon, Yeongdeok, we estimated groundwater quantity, groundwater level, and effective porosity, and examined surface water fluctuations with respect to the increased groundwater quantity based on the flow duration. The results reveal that the increased groundwater quantity was at most $91,746m^3$ in the total drainage basin of the groundwater dam, and the reduced groundwater quantity was at most $11,259m^3$ in the lower zone of the groundwater dam. Therefore, the total groundwater resources secured was $80,487m^3$ and the decrease in groundwater quantity was just 12.27% of the amount of increase. There were changes in discharge rate by up to $3.00{\times}10^{-2}m^3/s$, as deduced from an analysis offlow duration as a result of groundwater dam construction. The overall difference between before and after construction of the dam was almost insignificant compared with the previous dam. The present results indicate that dammed groundwater can serve as an alternative water resource with sufficient quantity.

The Characteristics on Infiltration of Fine-Grained Soil into Various Materials for Ground Drainage (지반 배수재에 따른 세립토의 관입특성)

  • Koh, Yongil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.11
    • /
    • pp.39-43
    • /
    • 2015
  • In this study, the infiltration quantity of fine-grained soil into coarse-grained soil or aggregate for methods to accelerate consolidation drainage is checked by laboratory tests under various conditions and those characteristics on infiltration are examined closely. Irrespectively of pressures to fine-grained soil corresponding to stresses in a soil mass or moisture contents of fine-grained soil, fine-grained soil does not infiltrate into standard sand and marine sand, so it is verified that drain-resistance into sand mass of drainage / pile does not occur entirely and its shear strength would increase highly by water compaction. It is known that the infiltration depth of fine-grained soil into aggregate increases according that those size is larger in case of aggregates and it increases according that the pressure or the moisture contents is higher in case of same size aggregate. It is thought that drain-resistance into aggregate mass of drainage / pile would occurs by infiltrated fine-grained soil in advance though the infiltration depth of fine-grained soi of lower moisture content than liquid limit into 13 mm aggregate is low quietly. So gravel drain method or gravel compaction pile method, etc. using aggregate of gravels or crushed stones, etc. larger than sand particle size should be not applied in very soft fine-grained soil mass of higher natural moisture contents than liquid limit, and it is thought that its applying is not nearly efficient also in soft fine-grained soil mass of lower natural moisture contents than liquid limit.

Neutralization Processes of Acid Mine Drainage (AMD) from the Abandoned Donghae Coal Mine (동해 폐탄광 일대 산성 광산폐수의 중화처리)

  • 김정엽;전효택;오대균
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.2 no.1
    • /
    • pp.38-47
    • /
    • 1995
  • This study was carried out in order to provide basic information on neutralization processes of acid mine drainage (AMD) from the abandoned Donghae coal mine in the Samchuk coalfield. The contents of potentially toxic elements in stream water increase and the level of pH decreases during dry season. Hydrated lime is turned out to be the best neutralizer of the acid mine water from a technical and economic viewpoint. From the results of equilibrium calculation, Fe and Al could be precipitated as FeOOH, and Al(OH)$_3$, respectively, in the neutralization process. The sites of holding basins necessary to equalize quantity and quality of AMD are recommended by GIS analysis, and the capacities of holding basins are determined by hydrological calculation.

  • PDF

Experimental Study on Rainfall Runoff Reduction Effects by Permeable Polymer Block Pavement (투수성 폴리머 블록 포장에 의한 우수 유출 저감 효과에 관한 실험적 연구)

  • Sung, Chan-Yong;Kim, Young-Ik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.2
    • /
    • pp.157-166
    • /
    • 2012
  • Most of the roads are paved with impermeable materials such as asphalt concrete and cement concrete, and in the event of heavy rainfall, rainwater directly flows into river through a drainage hole on the pavement surface. This large quantity of rainwater directly spilled into the river frequently leads to the flooding of urban streams, damaging lowlands and the lower reaches of a river. In recent years there has been a great deal of ongoing research concerning water permeability and drainage in pavements. Accordingly, in this research, a porous polymer concrete was developed for permeable pavement by using unsaturated polyester resin as a binder, recycled aggregate as coarse aggregate, fly ash and blast furnace slag as filler, and its physical and mechanical properties were investigated. Also, 3 types of permeable polymer block by optimum mix design were developed and rainfall runoff reduction effects by permeability pavement using permeable polymer block were analyzed based on hydraulic experimental model. The infiltration volume, infiltration ratio, runoff initial time and runoff volume in permeability pavement with permeable polymer block of $300{\times}300{\times}80$ mm were evaluated for 50, 100 and 200mm/hr rainfall intensity.

Best Site Identification for Spatially Distributed On-Site Stormwater Control Devices in an Urban Drainage System (도시유역에서 공간적으로 분포된 소규모 강우유출수 관리시설의 최적설치위치선정)

  • Kim, Sangdan;Lim, Yong Kun;Kim, Jin Kwan;Kang, Dookee;Seo, Seongcheol;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.986-993
    • /
    • 2010
  • Spatially distributed on-site devices such as bioretentions and bioboxfilters are becoming more common as a means of controlling urban stormwater quality. One approach to modeling the cumulative catchment-scale effects of such devices is to resolve the catchment down to the scale of a land parcel or finer, and then to model each device separately. The focus of this study is to propose a semi-distributed model for simulating urban stormwater quantity and identifying best sites for spatially distributed on-site stormwater control devices in an urban drainage system. A detailed model for urban stormwater improvement conceptualization simulation is set up for a $0.9342km^2$.