• Title/Summary/Keyword: Quantitative ultrasound

Search Result 139, Processing Time 0.032 seconds

Comparative Study on Signal Strength of Mechanical Index Using Ultrasound Machines with SonoVue Contrast (Sonovue 초음파 조영제를 이용한 장비 간 Mechanical Index의 변화에 따른 신호 강도 비교연구)

  • Kim, Myung-Seok;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • The purpose of this study was to compare the MI using SonoVue along with different machines output and to infer the meaning of the signal difference under the same condition. All of the comparative instruments showed strong signal values at early stage as MI value increased. Over time, the inter-instrumental signal values showed signal attenuation under all conditions except for 10 min of the condition of MI 0.1 of RS85A. E9 and EPIQ7 showed signal degradation due to microbubble collapse over time at all MI values. In the comparison of equipment, the signal strengths of MI 0.1, 0.2, and 0.4 were high in order of EPIQ7, RS85A and E9. In the quantitative analysis, there were statistically significant from the SNR and CNR that were obtained from RS85A and E9 (P-value<0.05). In the quantitative analysis, Epiq7 was statistically significant except for CNR as the MI value was changed In the contrast-enhanced ultrasound, even though MI value was low (MI <0.05), it will be helpful for diagnosis, controlling the MI and scan time because a difference in signal intensity was shown between the three machines.

Effect of Cortical Bone on Acoustic Properties of Trabecular Bone in Bovine Femur In Vitro (생체 외 조건의 소 대퇴골에서 해면질골의 음향특성에 대한 피질골의 효과)

  • Hwang, Kyo Seung;Lee, Kang Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.181-189
    • /
    • 2013
  • The purpose of the present study is to investigate the effect of cortical bone on acoustic properties of trabecular bone, such as speed of sound (SOS) and normalized broadband ultrasound attenuation (nBUA), in bovine femur in vitro. Twelve trabecular bone samples and three cortical bone plates with thicknesses of 1.00, 1.47, and 2.00 mm were extracted from the proximal end of two bovine femurs. The correlations between acoustic properties and trabecular apparent bone density were also examined before and after attaching a cortical bone plate to the trabecular bone samples. SOS increased linearly with increasing thickness of the cortical plate attached to one side of ultrasonic incidence of the trabecular bone samples, whereas nBUA showed a nonlinear dependence on the thickness of the cortical plate. All the SOS (r = 0.95-0.97) and nBUA (r = 0.53-0.73) measurements with and without the cortical bone plate with various thicknesses were found to exhibit high correlations with the trabecular apparent bone density. These results imply that the acoustic properties measured in the femur with lateral cortical layers in vitro can be useful indices for the prediction of trabecular bone mineral density.

Ultrasonic image assessment of the degree of pancreatic fat deposition (췌장 지방 침착 정도에 따른 초음파 영상 평가)

  • Park, Hye-in;Park, Seung-hun;Beak, Yun-seung;Lee, Seon-bin;Lee, Eun-sol;Heo, Yeong-dae;Cho, Jin-young;Ko, Seong-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.490-492
    • /
    • 2016
  • Pancreatic ultrasound imaging is used to diagnose pancreatic hyperplasia, pancreatic steatosis, pancreatic cancer and the like. If the diagnosis of pancreatic steatosis is pancreatic parenchyma echo shades splashes spleen than in the pancreas ultrasound it determines that the fat is deposited. And research on ultrasound imaging of pancreatic cancer but is actively conducted research studies on pancreatic steatosis is insufficient In addition, pancreatic steatosis is often an error in accordance with the diagnostic criteria are vague and subjective diagnosis of the artisan. This study was a quantitative analysis using the feature value extracting a feature of an image extracted by applying a parameter to the algorithm GLCM image of the normal and pancreatic fat. Setting a region of interest ($5{\times}5pixel$) in the mild 89 case, moderate 89 case, severe 89 case, total image 267 case using GLCM algorithm, and using the Autocorrelation, Sum average, Sum of squares, Sum varience 4 kinds parameter in each image It was analyzed.

  • PDF

Early Prediction of Liver Fibrosis Using Shear Wave Elastography (전단파 탄성 초음파(Shear Wave Elastography)를 이용한 조기 간섬유화 예측)

  • Seo-Won Choo;Jong-Nam Song;Cheol-Min Jeon;Jae-Bok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1057-1065
    • /
    • 2023
  • Non-invasive liver fibrosis diagnosis is crucial for patients with chronic liver diseases. Many patients cannot undergo liver tissue biopsy, so predicting the degree of liver fibrosis early through meaningful methods can reduce complications related to chronic liver diseases, such as liver cell carcinoma and cirrhosis. This study compared and analyzed the quantitative measurement of liver fibrosis using shear wave elastography in conjunction with liver ultrasound findings and their associations with serum biomarkers (p<0.05). The results showed that the shear wave elastography measurement in the normal group was 4.55 ± 0.69 kPa, while the abnormal contrast group with echogenic patterns had a measurement of 8.27 ± 1.83 kPa. The hepatitis B carrier group exhibited higher shear wave elastography measurements, and among serum biomarkers, AST, ALT, GGT, and PT showed statistically significant positive correlations with fibrosis severity according to SWE categories (p<0.05), while ALP and TB did not demonstrate statistically significant differences (p=0.163, p=0.567). Conversely, Albumin and PLT showed significant negative correlations (p<0.05). Clinically, utilizing shear wave elastography measurements through liver ultrasound in the tracking and repeat testing of liver fibrosis in chronic hepatitis B patients without cirrhosis can assist in achieving more objective diagnoses among healthcare providers.

Quantitative Analysis of Enlarged Cervical Lymph Nodes with Ultrasound Elastography

  • Zhang, Jun-Peng;Liu, Hua-Yan;Ning, Chun-Ping;Chong, Jing;Sun, Yong-Mei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7291-7294
    • /
    • 2015
  • Purpsoe: To investigate the diagnostic value of quantitative analysis of a tissue diffusion and virtual touch tissue imaging quantification (VTIQ) technique with acoustic radiation force impulse (ARFI) elastography for assessing enlarged cervical lymph nodes. Materials and Methods: Fifty-six enlarged cervical lymph nodes confirmed by pathologic diagnoses were covered in the study. According to the results of pathologic diagnosis, patients were classified into benign and malignant groups. All the patients were examined by both conventional ultrasonography and elastography. AREA% and shear wave velocity (SWV) in ROI of different groups were calculated and compared using ROC curves. Cut-off points of AREA% and SWV were determined with receiver operating characteristic curves. Results: Final histopathological results revealed 21 cases of benign and 35 cases of malignant lymph nodes. The mean values of AREA% and SWV in benign and malignant groups were $45.0{\pm}17.9%$ and $2.32{\pm}0.57m/s$, and $61.3{\pm}21.29%$ and $4.36{\pm}1.25$)m/s, respectively. For the parameters of elastography, "AREA%" and SWV demonstrated significant differences between groups (p=0.002). AREA% was positively correlated with SWV with a correlation coefficient of 0.809 (P<0.001). Conclusions: Stiffness of different lymph node diseases in patients may differ. Elastography can evaluate changes sensitively and provide valuable information to doctors. The study proved that the VTIQ elastography technique can play an important role in differential diagnosis of lymph nodes.

Comparative Study on Nutrients Intake, Physical Activities and Bone Mineral Density of Specialized Game High School dentsaccording to Obesity Level (게임특성화 고등학교 학생의 비만도에 따른 영양상태, 생활습관 및 골밀도 비교 연구)

  • Oh, Yun-Kyoung;Sohn, Cheong-Min
    • Korean Journal of Community Nutrition
    • /
    • v.15 no.3
    • /
    • pp.393-402
    • /
    • 2010
  • The purpose of this study was performed to evaluate the prevalence of overweight and to compare the dietary behaviors, nutrient intake and physical activities of specialized game high school students. Total of 163 subjects participated and their weight, height, waist circumference, hip circumference and bone status by a quantitative ultrasound method were measured. The subjects were surveyed by a self-administered questionnaire about general characteristics, dietary behaviors and physical activities. Nutrient intakes of the subjects were assessed by semi-quantitative food frequency questionnaire. The subjects were divided into four groups on their obesity level by BMI. The prevalence of underweight, normal, overweight and obese group was 6%, 58%, 16%, and 20% respectively. BMI was negatively correlated with bone mineral density (p < 0.01) and positively correlated with WHR (p < 0.01). The dietary guideline compliance score for "Enjoy Korean rice food style" was 2.63, followed by "Prepare food sanitarily"2.48, "Do not skip breakfast"2.29, "Eat a variety of vegetables, fruits, dairy products daily"2.25, "Drink water instead of beverage"2.10, "Choose less fried foods"2.09 and "Maintain healthy weight"1.91. The exercise frequency of walking was not significantly different between groups; however, heavy exercise frequency was significantly lower in underweight group than the other groups (p < 0.05). The energy intake was 2153 kcal, which was 81.2% of the Estimate Energy Requirement, and the intake of calcium and vitamin $B_2$ was 66.7% and 77.8% of KDRIs. Particularly, the intake of iron, vitamin A and vitamin C was about 59.4%, 52.2% and 55.4% of KDRIs and INQ was 0.71, 0.63 and 0.65 respectively, and intake of folic acid fell behind 39.1% of KDRIs and INQ was 0.46. Our study suggests that the systematic and continuous nutrition education will have to be provided at schools to improve dietary and health behaviors and prevent chronic metabolic disease for students of specialized game high school.

High dairy products intake reduces osteoporosis risk in Korean postmenopausal women: A 4 year follow-up study

  • Park, Seon-Joo;Jung, Ji Hye;Ki, Myung-Sunny;Lee, Hae-Jeung
    • Nutrition Research and Practice
    • /
    • v.12 no.5
    • /
    • pp.436-442
    • /
    • 2018
  • BACKGROUND/OBJECTIVES: The aim of this study was to identify the effect of dairy products, milk and yogurt on osteoporosis incidence among Korean postmenopausal women using prospective cohort data. MATERIALS/METHODS: Between 2001 and 2003, 10,038 participants were recruited in rural and urban areas for a baseline examination of a community-based cohort study. Of those, 1,573 postmenopausal women (aged 40-69 years at baseline) were eligible for the present study. Intakes of dairy products, milk, and yogurt were assessed using a validated semi-quantitative food frequency questionnaire. The speed of sound at the radius and tibia were measured using a quantitative ultrasound device and osteoporosis was defined based on the WHO criteria (T-score ${\leq}-2.5$). RESULTS: During the 4-years follow-up study, the cumulative incidence of osteoporosis was 18.4% (273 cases) in the radius and 33.6% (407 cases) in the tibia. The subjects with higher frequency of dairy product consumption showed a decreased risk of radius osteoporosis after adjusting for potential confounders [hazard ratio (HR) = 0.51, 95% confidence interval (CI): 0.33-0.80 for >1 time/day vs. non consumer; P for trend = 0.0027]. Similarly, high frequency of milk and yogurt consumption had a protective effect on radius osteoporosis risk [milk: HR = 0.60, 95% CI: 0.42-0.87 for > 5-6 times/week vs. non consumer (P for trend = 0.0130), yogurt: HR = 0.51, 95% CI: 0.30-0.85 for > 5-6 times/week vs. non consumer (P for trend = 0.0167)]. However, high dairy products consumption was not related with tibia osteoporosis. CONCLUSIONS: This study suggests that daily intake of dairy products could potentially reduce radius osteoporosis incidence among Korean postmenopausal women.

Bone Mineral Density and Factors Affecting in Female College Students (여대생의 골밀도와 영향 요인에 관한 연구)

  • Cho, Dong-Sook;Lee, Jeung-Yun
    • Women's Health Nursing
    • /
    • v.14 no.4
    • /
    • pp.297-305
    • /
    • 2008
  • Purpose: This study was performed to assess the relationships among bone mineral density, dietary habits, life styles and anthropometric measurements in young women. Subjects included 229 female college students in Seoul and Kyunggi province. Method: The subjects were asked about dietary habits and life styles using questionnaire. A sampel of 229 young women was assessed anthropometric measurements and bone mineral density on calcaneous using quantitative ultrasound. Result: The percentages of the osteoporosis(T-score<-2.5), osteopenia(-2.5${\leq}$T-score<-1.0), and normal(T-score${\geq}$-1.0) groups were 1.75%, 13.53% and 84.71%, respectively. Weight, soft lean mass, and BMI were positively related with T-score and Z-score. But height was negative related with SOS(Speed of sounds). Conclusion: This study confirmed that one of the most effective ways to minimize bone mineral density less in young women is to maintain an adequate body weight, soft lean mass, and BMI. And the young women were recommended do not one-side eating, daily intakes of milk products, perform daily physical exercise, and do not drink coke or soft drinks for the bone health.

  • PDF

Ultrasonic Evaluation of Interfacial Stiffness for Nonlinear Contact Surfaces

  • Kim, Noh-Yu;Kim, Hyun-Dong;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.504-511
    • /
    • 2008
  • This paper proposes an ultrasonic measurement method for measurement of linear interfacial stiffness of contacting surface between two steel plates subjected to nominal compression pressures. Interfacial stiffness was evaluated by using shear waves reflected at contact interface of two identical solid plates. Three consecutive reflection waves from solid-solid surface are captured by pulse-echo method to evaluate the state of contact interface. A non-dimensional parameter defined as the ratio of their peak-to-peak amplitudes are formulated and used to calculate the quantitative stiffness of interface. Mathematical model for 1-D wave propagation across interfaces is developed to formulate the reflection and transmission waves across the interface and to determine the interfacial stiffness. Two identical plates are fabricated and assembled to form contacting surface and to measure interfacial stiffness at different states of contact pressure by means of bolt fastening. It is found from experiment that the amplitude of interfacial stiffness is dependent on the pressure and successfully determined by employing pulse-echo ultrasonic method without measuring through-transmission waves.

Postoperative Transesophageal Echocardiographic Evaluation in Patients with Cardiac Valve Replacement (경식도 심초음파 검사를 이용한 판막대치술 환자의 평가)

  • 조건현
    • Journal of Chest Surgery
    • /
    • v.24 no.3
    • /
    • pp.265-270
    • /
    • 1991
  • Since advent of the prosthetic cardiac valve replacement, much efforts for accurate assessing value function in-vivo have been attempted. To evaluate the postoperative functional and morphological status of the replaced cardiac valve prosthesis, 33 patients with valve replacement were studied by transthoracic and transesophageal 2-dimensional echocardiac imaging as well as by color Doppler flow velocity imaging. Twenty four patients had mitral valve replacement. 6 patients had aortic valve replacement and 3 patients had both mitral and aortic valve replacement. There were 34 mechanical and 2 biological prosthesis. Comparing to transthoracic echocardiography, transesophageal approach showed transvalvular regurgitant jet flow amid the prosthetic mitral valve ring during. systole and much clear visualization of cardiac chamber behind prosthesis which could give shadowing effect to ultrasound beam. According to the quantitative grading by the length and area of mitral regurgitant flow, 24 out of 27 mitral valves revealed mild degree regurgitation considered as physiological after prosthetic bileaflet valve replacement and the other 3 valves including 2 biological prosthesis had moderate degree regurgitation which was regarded as pathologic one. 2 cases of left atrial thromboses and 1 case of paravalvular leakage which were not visible by transthoracic approach were identified by transesophageal echocardiography in patients with mitral valve replacement and patients with aortic valve replacement respectively. We conclude that in patients with prosthetic mitral valve replacement, transesophageal 2-dimensional imaging with color Doppler can suggest reliable information beyond that available from the transthoracic access even though it gives patient some discomfort to proceed.

  • PDF