• Title/Summary/Keyword: Quantitative rehabilitation evaluation

Search Result 47, Processing Time 0.021 seconds

Investigation of the Regression Analysis Method for a Quantitative Evaluation of Implant Crestal Bone Stresses (회귀분석법에 의한 임플란트 경부골 응력의 정량적 분석에 대한 연구)

  • Kim, Woo-Shik;Jo, Kwang-Hun;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.299-310
    • /
    • 2008
  • In this study, the regression analysis method was tested for the estimation of peak stress at stress concentration area in the cervical bone. Submerge type EZ plus implant (Megagen. Daegu, Korea), 4.1 mm in cervical diameter and 9.6 mm in endosseous length, were axisymmetrically modelled together with surrounding alveolar bone of which the width was 10 mm. Vertical force of 100 N was applied to a head of crown above 8.5 mm from the outer surface of the cortical bone. Four different mesh models were composed of differently sized elements in vicinity of sharp corners, and they include 6 stress monitoring points that are located in the same geometrical points regardless of the differences in the meshes. Primary consideration was given to the stresses in the cortical bone surrounding the implant neck. The results showed that virtually all the stresses were concentrated in the cortical bone regardless of mesh designs. The peak stresses were successfully calculated by a regression analysis in a stable manner, as far as the mesh is designed to represent the acute gradient of stresses near the sharp corner.

Reliability of Modified Ashworth Scale Using a Haptic Robot Finger Simulating Finger Spasticity (손가락 경직을 모사하는 로봇 시뮬레이터를 이용한 경직도 검진의 신뢰도 평가)

  • Ha, Dokyeong;Park, Hyung-Soon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.2
    • /
    • pp.125-133
    • /
    • 2017
  • This paper presents the inter-rater reliability of finger spasticity assessment tested realized by using finger simulator that mimics finger spasticity of patients after a stroke. For controlling the simulator torque, finger spasticity was modeled, and the model parameters were obtained by measuring quantitative data while grading based on Modified Ashworth Scale (MAS). A robotic finger simulator was designed for mimicking finger spasticity. Evaluation of this simulator with the help of seven rehabilitation doctors showed that the simulator had a Cohen's kappa value of 0.619 for Metacarpophalangeal Joint and 0.514 for Proximal Interphalangeal Joint. Fleiss' kappa between raters is 0.513 for Metacarpophalangeal Joint and 0.486 for Proximal Interphalangeal Joint. Therefore, the spasticity assessment made by MAS grade system is not reliable owing to the subjectivity of the assessment. The proposed robotic simulator can be used as a training tool for improving the reliability of the spasticity assessment.

Comparison of Maximum Fingertip Force Distribution in Cylindrical Grasping Between Healthy Adults and Patients With Spinal Cord Injury (원통형 물체 쥐기 시 건강한 성인과 척수마비 환자의 최대 손가락 끝 힘 분포 비교)

  • Hwang, Jisun;Ree, Jae Sun;Hwang, Seonhong
    • Physical Therapy Korea
    • /
    • v.29 no.1
    • /
    • pp.28-36
    • /
    • 2022
  • Background: It is known that hand strength and fingertip force are used as an indicator of muscle strength and are also highly related to the various chronic symptoms and even lifespan. To use the individual fingertip force (IFF) as a quantitative index for clinical evaluation, the IFF should be measured and analyzed with various variables from various subjects, such as the normal range of fingertip force and the difference in its distribution by disease. Objects: We tried to measure and analyze the mean maximum IFF distribution during grasping a cylindrical object in healthy adults and patients with spinal cord injury (SCI). Methods: Five Force-sensitive resistor (FSR) sensors were attached to the fingertips of 24 healthy people and 13 patients with SCI. They were asked to grip the object three times for five seconds with their maximum effort. Results: The mean maximum IFF of the healthy adult group's thumb, index, and middle finger was similar statistically and showed relatively larger than IFF of the ring and small finger. It is a 3-point pinch grip pattern. All fingertip forces of patients with SCI decreased by more than 50% to the healthy group, and their IFF of the middle finger was relatively the largest among the five fingertip forces. The cervical level injured SCI patients showed significantly decreased IFFs compared to thoracic level injured SCI patients. Conclusion: We expect that this study results would be helpful for rehabilitation diagnosis and therapy goal decision with robust further study.

The analysis of tissue elasticity using computer-controlled ultrasonography in the affected upper limb of patients after breast cancer surgery

  • Chan-Hyuk Kwon;Min Woo Ha
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.6
    • /
    • pp.167-173
    • /
    • 2024
  • In this paper, we propse a quantitative research by investigating the subcutaneous tissue elasticity by using ultrasonography in lymphedema patients after breast cancer surgery. Lymphedema patients who took breast cancer operation were included. Thickness of subcutaneous tissue was assessed at two spots; 10cm below elbow (forearm) and 10cm above elbow (upper arm), not only in affected side but also in sound side. By using probe attached to real-time pressure sensor, stress-strain curves were obtained. We defined tissue elasticity as slope of that curve at range of 7.5~15% of strain to avoid toe region. By comparing the elasticity of normal side and that of affected side, lymphedema tissues were classified into 'softer' and 'harder' tissues. Overall 30 cases of lymphedema tissues and 30 cases of sound tissues were checked. The difference of the elasticity between normal and affected side ranged from -3.98 N/m2 to 1.40 N/m2. The lymphedema tissues were classified into 17 softer tissues and 13 harder tissues. No demographic and clinical values, including clinical stage of lymphedema, showed statistically meaningful differences between two groups. Evaluation of subcutaneous tissue elasticity with ultrasonography and real-time pressure sensor could be one of the useful tools for investigation of lymphedema tissue characteristics.

Detection of HER2 Status in Breast Cancer: Comparison of Current Methods with MLPA and Real-time RT-PCR

  • Pazhoomand, Reza;Keyhan, Elahe;Banan, Mehdi;Najmabad, Hossein;Karimlou, Masoud;Khodadad, Faranak;Iraniparast, Alireza;Feiz, Farnaz;Majidzadeh, Keivan;Bahman, Ideh;Moghadam, Fatemeh Aghakhani;Sobhani, Atoosa Madadkar;Abedin, Seyedeh Sedigheh;Muhammadnejad, Ahad;Behjat, Farkhondeh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7621-7628
    • /
    • 2013
  • Human epidermal growth factor receptor (HER) status is an important prognostic factor in breast cancer. There is no globally accepted method for determining its status, and which method is most precise is still a matter of debate. We here analyzed HER2 mRNA expression by quantitative reverse transcription-PCR (qRT-PCR) and HER2 DNA amplification using multiplex ligation-dependent probe amplification (MLPA). In parallel, we performed a routine evaluation of HER2 protein by immunohistochemistry (IHC). To assess the accuracy of the RT-PCR and MLPA techniques, a combination of IHC and fluorescence in situ hybridization (FISH) was used, substituting FISH when the results of IHC were ambiguous (2+) and for those IHC results that disagreed with MLPA and qRT-PCR, this approach being termed IHC-FISH. The IHC results for four samples were not compatible with the MLPA and qRT-PCR results; the MLPA and qRT-PCR results for these samples were confirmed by FISH. The correlations between IHC-FISH and qRT-PCR or MLPA were 0.945 and 0.973, respectively. The ASCO/CAP guideline IHC/FISH correlation with MLPA was (0.827) and with RT-PCR was (0.854). The correlations between the IHC results (0, 1+ as negative, and 3+ as positive) and qRT-PCR and MLPA techniques were 0.743 and 0.831, respectively. Given the shortcomings of IHC analysis and greater correlations between MLPA, qRT-PCR, and FISH methods than IHC analysis alone with each of these three methods, we propose that MLPA and real-time PCR are good alternatives to IHC. However a suitable cut-off point for qRTPCR is a prerequisite for determining the exact status of HER2.

Case Study on the Application and Evaluation of an Integrated Medical Service Model to Improve the Quality of Life for Breast Cancer Patients and Caregivers (유방암 환자와 보호자의 삶의 질 증진을 위한 통합의료서비스모델 적용평가 사례 연구)

  • Moon Joo Cheong;Do-Eun Lee;Un Jong Choi;Han Baek Cho;Hyung Won Kang
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.3
    • /
    • pp.163-178
    • /
    • 2024
  • Purpose : This study aimed to evaluate the effectiveness of an integrative medical service model applied to breast cancer patients and their caregivers, exploring its feasibility and challenges within the context of South Korean healthcare system. Methods : A case study approach was chosen to assess the integrative medical service model's efficacy, involving one breast cancer patient and her primary caregiver from W University Hospital. The patient had completed reconstructive surgery and chemotherapy and was undergoing radiotherapy. The model included standard treatments alongside psychological counseling, aromatherapy, axillary rehabilitation exercise, make-up program, art therapy, laughter therapy, horticultural therapy, and yoga programs, and meditation programs delivered over eight weeks. Quantitative and qualitative data were collected through surveys, psychological tests, and feedback assessments. Results : The integrative medical service model demonstrated notable improvements in the quality of life for both breast cancer patients and their caregivers. Participants reported enhanced emotional well-being, reduced stress levels, and improved coping mechanisms throughout the treatment journey. Qualitative feedback highlighted the positive impact of holistic interventions in alleviating psychological distress and fostering resilience. Quantitative data corroborated these findings, showing statistically significant improvements in various psychosocial parameters assessed. Conclusions : Our findings underscore the benefits of integrative medical service model with standard medical treatments in the care of breast cancer patients and their caregivers. The holistic approach not only addresses physical symptoms but also enhances overall well-being and quality of life. However, the implementation of such models faces challenges within the South Korean healthcare system, including fragmented service networks and financial constraints. Addressing these structural barriers is crucial for the widespread adoption and sustainability of integrative care models in oncology practice. Future research should focus on larger-scale studies to further validate these findings and inform policy decisions aimed at optimizing cancer care delivery.

Evaluation of periopathogenic bacteria of peri-implantitis using real-time PCR in Koreans: pilot study (한국인의 임플란트 주위 질환에서 real time PCR법을 이용한 치주세균 평가: pilot study)

  • Lee, Mun-Young;Kwon, Eun-Young;Kim, Hyun-Joo;Lee, Ju-Youn;Joo, Ji-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.186-195
    • /
    • 2018
  • Purpose: We performed quantitative and qualitative analysis of typical periodontal bacteria using real time PCR method to investigate the microbiological difference according to the severity of peri-implant disease in Koreans. Materials and Methods: Total of 60 implants were divided into three groups (healthy group, peri-implant mucositis group, peri-implantitis group) through periapical radiographs and clinical indices. The evaluated clinical parameters were pocket depth, plaque index, suppuration and bleeding on probing. Using a sterilized curette instrument, microbial samples were collected from the subgingival plaque and real-time PCR was performed on five periodontal bacteria. The relative expression levels of microorganisms were compared by comparative delta-CT method. Results: The relative expression levels of E. corrodens and T. denticola were significantly higher in the peri-implantitis group (P < 0.017). On the other hand, the relative expression level of F. nucleatum and P. gingivalis was relatively high in the healthy implant group regardless of the severity of disease. P. intermedia was significantly lower in the healthy implant group (P < 0.017). Conclusion: Periodontal bacteria were detected in Koreans with peri-implant diseases, but there was no microbiological distribution similar to periodontitis.