• Title/Summary/Keyword: Quantitative CT

Search Result 325, Processing Time 0.027 seconds

Silver Diamine Fluoride Compound for Dental Caries and Its Characterisation Using Microscopic Computed Tomography and Nanoindentation

  • So-Youn An;Myung-Jin Lee;Min-Kyung Kang;Youn-Soo Shim
    • Journal of dental hygiene science
    • /
    • v.23 no.1
    • /
    • pp.60-67
    • /
    • 2023
  • Background: In our study, a silver diamine fluoride (SDF) compound for the treatment of dental caries was synthesized to characterize its remineralization activity upon direct application to deciduous teeth. This study aimed to use microscopic computed tomography (microCT) and nanoindentation to evaluate whether SDF composite application could effectively arrest dental caries in five exfoliated primary molars. Methods: Carious teeth were extracted and visually examined using quantitative photofluorescence devices (Qraycam and QraypenTM). After performing microCT, the SDF composite was applied to the teeth according to the manufacturer's instructions. The researchers exchanged and precipitated the irritant saliva once daily for 1 week. The teeth were sectioned longitudinally through the centers of the mesial and distal surfaces, embedded, polished, and measured using nanoindentation. Thereafter, microCT was repeated. Statistical analyses were performed using GraphPad Prism software. Results: Following SDF composite application, a remineralized layer was observed on microCT images, and the hardness increased when measured using nanoindentation. We found that demineralized enamel presented with an increased number of irregular crystals in the deep carious lesion group compared with those in the shallow carious lesion group, resulting in a rougher surface. Conclusion: The SDF composite may be used for remineralization of early caries and cessation of advanced caries in primary molars.

A study of beam hardening effect reduction occur in brain CT (Brain CT에서 발생하는 선속경화현상 감소방안에 관한 연구)

  • Kim, Hyeon-ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8479-8486
    • /
    • 2015
  • This study aim is occur in brain CT cause of beam hardening effect and reducing method, We will scan Bone opaque bead phantom on variation of image on the influence factor with equipment called 'Samatom Senation 16' with following listed herein : tube voltage, tube current, slice thickness, gantry angle, base line which affect beam-hardening effect. After that we are going to start Quantitative Analysis resulted in previous scanning and Qualitative Assessment with CT image sheet evaluation. result of quantitative analysis 140kVp $31.56{\pm}2.89HU$ on tube voltage, 150mA $-3.87{\pm}0.12HU$ on tube current, 3mm on slice thickness, and $13.31{\pm}1.03HU$ IOML on gantry angle which was the least beam-hardening effect. Like Qualitative Analysis, we went through Qualitative Assessment and most of valuers got a result of 140kVp on tube voltage, 150mA on tube current, 3mm on slice thickness. As before valuers evaluated gantry angle that scanned image from IOML or OML was the least beam-hardening effect occured. There are meaningful differences when we compare all theses factors statistically(P<0.05). therefore We consider that Minimizing artifact that caused by beam-hardening effect can provide better quality of image to deciphers and patients. if we rise tube voltage in permissible dose limit, set tube current in a limit that does not effect to image quality, use slice thickness too thin enough to harm resolution, use IOML or OML on gantry angle.

Quantitative analysis of hemothorax by computed tomography (흉부 전산화 단층촬영을 이용한 혈흉의 정량분석)

  • 강청희
    • Journal of Chest Surgery
    • /
    • v.28 no.3
    • /
    • pp.228-232
    • /
    • 1995
  • Computed tomography[CT is an effective technique for the evaluation of the thorax following blunt trauma. To evaluate multiply injured 30 patients who were diagnosed as hemothorax in emergency room, computed tomography of thorax was done. The thickness of slice was one centimeter and the entire pleural cavity from the apex to the costophrenic angle was included in the evaluation. Integration and addition of the hemothorax area for each CT slice was made and amount of blood in the pleural cavity was estimated. The slice which showed largest area of hemothorax was selected and the height and width of the hemothorax area were measured. The number of slices which showed radiographic evidence of hemothorax was counted. Regression analysis was done and measured amount of hemothorax, the height and width of the hemothorax area for each slice and number of slices were put as variables. And following equation was derived. V=108.3A-0.8B-7.4C+84.7 [R2=0.74 [ V: amount of hemothorax, A: height, B: width, C: number of slices Total amount of blood from thoracic drainage was compared to the measured amount by computed tomography and the relation between the two values was statistically significant.[p=0.001 In conclusion, quantitative estimation of size of hemothorax was possible by the above equation and the process was very helpful for determination policy of treatment of individual patient.

  • PDF

Quantitative Analysis of Lung Contusion (폐좌상의 정량분석)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.27 no.10
    • /
    • pp.833-837
    • /
    • 1994
  • Lung contusion due to blunt chest trauma is the most common lung injury and correlated with the clinical course and prognosis. Its diagnosis by CT[Computerized Tomogram] gives a more clear and understandable three dimensional view, by which we are able to measure the volume of the contused and entire lung. Other variables are arterial blood gas, number of rib fracture, presence of hemopneumothorax, sternal fracture and clavicle fracture, number of associated non-thoracic injuries, ventilator time and presence of pulmonary complication. Percentage[%] of lung contusion are expressed as mean $\pm$ standard deviation and data analysis was performed by means of multivariate repeated measures analysis of variance to detect significant differences in variables between positive thoracic injury group and negative group. The paired t-test was used. Differences of percentage of lung contusion between groups were assessed by one-way analysis of variance. Simple linear regression was used to perform correlation analysis in the number of rib fracture and ventilator time. A p value less than 0.05 was considered statistically significant. Pneumothorax and the number of associated other injuries affect the amount of lung contusion and pulmonary complication group has more contused lung volume. Arterial blood gas study shows no correlation with the amount of lung contusion statistically. The number of rib fracture correlated with the amount of lung contusion, which also correlated with ventilator time[r=0.56, p<0.05]. In conclusion, quantitative anlysis of lung contusion by CT predicts the clinical course and treatment such as ventilator care.

  • PDF

Quantitative Evaluation of Setup Error for Whole Body Stereotactic Radiosurgery by Image Registration Technique

  • Kim, Young-Seok;Yi, Byong-Yong;Kim, Jong-Hoon;Ahn, Seung-Do;Lee, Sang-wook;Im, Ki-Chun;Park, Eun-Kyung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.103-105
    • /
    • 2002
  • Whole body stereotactic radiosurgery (WBSRS) technique is believed to be useful for the metastatic lesions as well as relatively small primary tumors in the trunk. Unlike stereotactic radiosurgery to intracranial lesion, inherent limitation on immobilization of whole body makes it difficult to achieve the reliable setup reproducibility. For this reason, it is essential to develop an objective and quantitative method of evaluating setup error for WBSRS. An evaluation technique using image registration has been developed for this purpose. Point pair image registrations with WBSRS frame coordinates were performed between two sets of CT images acquired before each treatment. Positional displacements could be determined by means of volumetric planning target volume (PTV) comparison between the reference and the registered image sets. Twenty eight sets of CT images from 19 WBSRS patients treated in Asan Medical Center have been analyzed by this method for determination of setup random error of each treatment. It is objective and clinically useful to analyze setup error quantitatively by image registration technique with WBSRS frame coordinates.

  • PDF

Effects of Dexamethasone on the Burden of Marine Birnavirus (MABV) in Olive Flounder, Paralichthys olivaceus (Dexamethasone 투여가 넙치(Paralichthys olivaceus)의 marine birnavirus (MABV) 감염강도에 미치는 영향)

  • Kwon, Se Ryun;Nam, Yoon Kwon
    • Korean Journal of Ichthyology
    • /
    • v.19 no.2
    • /
    • pp.88-92
    • /
    • 2007
  • The effect of dexamethasone injection on the burden of marine birnavirus (MABV) in asymptomatically infected olive flounder (Paralichthys olivaceus) fingerlings was investigated. In real time PCR analysis, the threshold cycle (Ct) value of the fish injected with dexamethasone was significantly lower than that of the fish in the PBS-injected and no-handling groups. The higher amplification of the MABV gene in the dexamethasone-injected group than the 2 control groups was confirmed also by semi-quantitative RT-PCR. The results indicate an increase of MABV burden in olive flounder fingerlings after a single injection with dexamethasone.

Machine Learning-based Prediction of Relative Regional Air Volume Change from Healthy Human Lung CTs

  • Eunchan Kim;YongHyun Lee;Jiwoong Choi;Byungjoon Yoo;Kum Ju Chae;Chang Hyun Lee
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.2
    • /
    • pp.576-590
    • /
    • 2023
  • Machine learning is widely used in various academic fields, and recently it has been actively applied in the medical research. In the medical field, machine learning is used in a variety of ways, such as speeding up diagnosis, discovering new biomarkers, or discovering latent traits of a disease. In the respiratory field, a relative regional air volume change (RRAVC) map based on quantitative inspiratory and expiratory computed tomography (CT) imaging can be used as a useful functional imaging biomarker for characterizing regional ventilation. In this study, we seek to predict RRAVC using various regular machine learning models such as extreme gradient boosting (XGBoost), light gradient boosting machine (LightGBM), and multi-layer perceptron (MLP). We experimentally show that MLP performs best, followed by XGBoost. We also propose several relative coordinate systems to minimize intersubjective variability. We confirm a significant experimental performance improvement when we apply a subject's relative proportion coordinates over conventional absolute coordinates.

Impact of Photon-Counting Detector Computed Tomography on Image Quality and Radiation Dose in Patients With Multiple Myeloma

  • Alexander Rau;Jakob Neubauer;Laetitia Taleb;Thomas Stein;Till Schuermann;Stephan Rau;Sebastian Faby;Sina Wenger;Monika Engelhardt;Fabian Bamberg;Jakob Weiss
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.1006-1016
    • /
    • 2023
  • Objective: Computed tomography (CT) is an established method for the diagnosis, staging, and treatment of multiple myeloma. Here, we investigated the potential of photon-counting detector computed tomography (PCD-CT) in terms of image quality, diagnostic confidence, and radiation dose compared with energy-integrating detector CT (EID-CT). Materials and Methods: In this prospective study, patients with known multiple myeloma underwent clinically indicated whole-body PCD-CT. The image quality of PCD-CT was assessed qualitatively by three independent radiologists for overall image quality, edge sharpness, image noise, lesion conspicuity, and diagnostic confidence using a 5-point Likert scale (5 = excellent), and quantitatively for signal homogeneity using the coefficient of variation (CV) of Hounsfield Units (HU) values and modulation transfer function (MTF) via the full width at half maximum (FWHM) in the frequency space. The results were compared with those of the current clinical standard EID-CT protocols as controls. Additionally, the radiation dose (CTDIvol) was determined. Results: We enrolled 35 patients with multiple myeloma (mean age 69.8 ± 9.1 years; 18 [51%] males). Qualitative image analysis revealed superior scores (median [interquartile range]) for PCD-CT regarding overall image quality (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), edge sharpness (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), image noise (4.0 [4.0-4.0] vs. 3.0 [3.0-4.0]), lesion conspicuity (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), and diagnostic confidence (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]) compared with EID-CT (P ≤ 0.004). In quantitative image analyses, PCD-CT compared with EID-CT revealed a substantially lower FWHM (2.89 vs. 25.68 cy/pixel) and a significantly more homogeneous signal (mean CV ± standard deviation [SD], 0.99 ± 0.65 vs. 1.66 ± 0.5; P < 0.001) at a significantly lower radiation dose (mean CTDIvol ± SD, 3.33 ± 0.82 vs. 7.19 ± 3.57 mGy; P < 0.001). Conclusion: Whole-body PCD-CT provides significantly higher subjective and objective image quality at significantly reduced radiation doses than the current clinical standard EID-CT protocols, along with readily available multi-spectral data, facilitating the potential for further advanced post-processing.

A Study on Spinal Bone Mineral Density Measured with Quantitative Computed Tomography (정량적 전산화 단층촬영법을 이용한 척추 골밀도 측정)

  • Yeo, Jin-Dong;Park, Jae-Seong
    • The Korean Journal of Health Service Management
    • /
    • v.3 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • The purpose of this study is to evaluate the relationship between osteoporotic postmenopausal women and its bone mineral density value by using the single energy quantitative CT. 1. Decreasing BMD with age is evident. There is a significant low BMD value in the osteoporotic women compared with the healthy subgroup. 2. BMD decrease from T12 to L4, except in healthy premenopausal women. 3. Relationship of spinal BMD expressed as average BMD of T12 through L4 Show strong correlation with mean BMD in all vertebral levels. 4. There are significantly different BMD value from T12 through L4 in subgroup 1, 2, 3 but there is no statistically significant difference between subgroup 2 and 3. Conclusion, There is a significant decreasing BMD with age but it is difficult to differentiate postmenopausal relatively healthy women from osteoporotic women by BMD.

  • PDF

Assessment of the Caries Detection Ability of Quantitative Light-induced Fluorescence (QLF) in Primary Teeth in vitro (유치의 치아우식증 확인을 위한 정량형광분석(QLF) 검사법의 우식탐지능력 평가)

  • Cho, Kyung Hyun;Kang, Chung-Min;Jung, Hoi-In;Lee, Tae Yang;Song, Je Seon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.65-75
    • /
    • 2022
  • The aim of this study was to evaluate QLF (quantitative light-induced fluorescence) technology for the caries detection in primary teeth and validate the relationships between the cavity volume of carious lesions and QLF analysis results. Total 125 tooth surfaces include 53 occlusal surfaces, and 72 proximal surfaces were investigated with the portable QLF device for detection of dental caries in primary molars. Micro-CT radiograph was also performed to classify carious lesions and calculate the cavity volume. QLF showed good accuracy and reliability (sensitivity 0.75 - 0.94, specificity 0.82 - 0.95, and AUROC 0.88 - 0.98) for the caries detection in primary teeth except 𝚫R average results of proximal caries which showed relatively low values. Statistically significant relationships were found between 𝚫F average, QS-Index and the cavity volume according to Spearman rank-order correlation coefficients (r = 0.805 - 0.832, p < 0.001). QLF detection method would be a harmless and reliable way for children to diagnose dental caries without the concern about radiation exposure.