• Title/Summary/Keyword: Quantification method

Search Result 1,508, Processing Time 0.027 seconds

Establishment of an Analytical Method for Novobiocin in Livestock Products Using HPLC-UVD (HPLC-UVD를 이용한 축산식품 중 Novobiocin의 시험법 확립)

  • Park, Hee-Ra;Kwon, Chan-Hyeok;Lee, Jong-Goo;Kim, Hyung-Soo;Chae, Young-Sik;Oh, Jae-Ho;Kwon, Ki-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.263-268
    • /
    • 2012
  • Novobiocin is a coumarin-containing antibiotic, and has a longer half-life in various animals than other veterinary medicines. A simple and rapid high-performance liquid chromatography assay for the determination of residual novobiocin levels in chicken, beef and milk has been developed and validated. The separation condition for HPLC/UVD was optimized by a MG II $C_{18}$ (4.6 mm $ID{\times}250$ mm, 5 ${\mu}m$) column with 0.1% formic acid in $H_2O$/0.1% formic acid in Acetonitrile (40/60, v/v) as the mobile phase at a flow rate of 1.0 mL/min and the detection wavelength was set at 340 nm. Residues were extracted from tissue by blending with methanol. After liquid-liquid partitioning, lipid materials were removed with n-hexane and purification as Silica (1 g, 6 mL) cartridge with 10 mL acetone/dichloromethane (10/90, v/v). Limit of quantification and linearity performed by the analytical method were 0.02 mg/kg and 0.999 ($r^2$), and the recovery range was $88.8{\pm}5.6-100.3{\pm}4.4$, $88.8{\pm}7.2-97.0{\pm}3.2$ and $88.1{\pm}4.3-92.8{\pm}3.6%$. It is expected that this analytical method with regards to novobiocin in chicken, beef and milk could be applied as an official method to administer food safety on veterinary medicines.

Development of a Simultaneous Analytical Method for Determination of Trinexapac-ethyl and Trinexapac in Agricultural Products Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 식물생장조절제 Trinexapac-ethyl과 대사산물 Trinexapac의 동시분석법 개발)

  • Jang, Jin;Kim, Heejung;Ko, Ah-Young;Lee, Eun-Hyang;Ju, Yunji;Chang, Moon-Ik;Rhee, Gyu-Seek;Suh, Saejung
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.4
    • /
    • pp.318-327
    • /
    • 2015
  • BACKGROUND: Trinexapac-ethyl is a plant growth regulator (PGR) that inhibits the biosynthesis of plant growth hormone (gibberellin). It is used for the prevention of lodging, increasing yields of cereals, and reducing mowing of turf. The experiment was conducted to establish a determination method for trinexapac-ethyl and its metabolites trinexapac in agricultural products using LC-MS/MS.METHODS AND RESULTS: Trinexapac-ethyl and trinexapac were extracted from agricultural products with methanol/ distilled water and the extract was partitioned with dichloromethane and then detected by LC-MS/MS. Limit of detection(LOD) was 0.003 mg/kg and limit of quantification(LOQ) was 0.01 mg/kg, respectively. Matrix matched calibration curves were linear over the calibration ranges (0.01-1.0 mg/L) for all the analytes into blank extract withr2> 0.997. For validation purposes, recovery studies were carried out at three different concentration levels (LOQ, 10LOQ, 50LOQ,n=5). Recoveries of trinexapacethyl and trinexapac were within the range of 73.6-106.9%, 72.7-99.2%, respectively. The relative standard deviations (RSDs) were less than 9.0%. All values were consistent with the criteria ranges requested in the CODEX guideline(CAC/GL 40, 2003).CONCLUSION: The proposed analytical method was accurate, effective and sensitive for trinexapac-ethyl and trinexapac determination and it can be used to as an official method in Korea.

Method Validation for Determination of Lignan Content in Fermented Sesame by Bioconversion (생물전환된 참깨 발효물의 Lignan 화합물의 분석법 검증)

  • Jung, Tae-Dong;Kim, Jae-Min;Choi, Sun-Il;Choi, Seung-Hyun;Cho, Bong-Yeon;Lee, Jin-Ha;Lee, Sang Jong;Park, Seon Ju;Heo, In Young;Lee, Ok-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.5
    • /
    • pp.646-652
    • /
    • 2017
  • The aim of this study was to investigate method validation for determination of sesamol, sesamin, and sesamolin in non-fermented sesame and fermented sesame by bioconversion. For validation, the specificity, linearity, precision, accuracy, limits of detection (LOD), and quantification (LOQ) of sesamol, sesamin, and sesamolin were measured by HPLC. Linearity tests showed that the coefficients of calibration correlation ($R^2$) for sesamol, sesamin, and sesamolin were 0.9999. Recovery rates of lignan contents in non-fermented and fermented sesame were high in the ranges of 100.27~115.10% and 98.43~114.90%, respectively. The inter-day and intra-day precisions of sesamin and sesamolin analyses for non-fermented and fermented sesame were 0.27~1.94% and 0.25~0.69%, respectively. The LOD and LOQ were $0.23{\sim}0.34{\mu}g/g$ and $0.70{\sim}1.03{\mu}g/g$, respectively. These results indicate that the validated method is appropriate for the determination of sesamol, sesamin, and sesamolin.

Quantitative Elemental Analysis in Soils by using Laser Induced Breakdown Spectroscopy(LIBS) (레이저유도붕괴분광법을 활용한 토양의 정량분석)

  • Zhang, Yong-Seon;Lee, Gye-Jun;Lee, Jeong-Tae;Hwang, Seon-Woong;Jin, Yong-Ik;Park, Chan-Won;Moon, Yong-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.5
    • /
    • pp.399-407
    • /
    • 2009
  • Laser induced breakdown spectroscopy(LIBS) is an simple analysis method for directly quantifying many kinds of soil micro-elements on site using a small size of laser without pre-treatment at any property of materials(solid, liquid and gas). The purpose of this study were to find an optimum condition of the LIBS measurement including wavelengths for quantifying soil elements, to relate spectral properties to the concentration of soil elements using LIBS as a simultaneous un-breakdown quantitative analysis technology, which can be applied for the safety assessment of agricultural products and precision agriculture, and to compare the results with a standardized chemical analysis method. Soil samples classified as fine-silty, mixed, thermic Typic Hapludalf(Memphis series) from grassland and uplands in Tennessee, USA were collected, crushed, and prepared for further analysis or LIBS measurement. The samples were measured using LIBS ranged from 200 to 600 nm(0.03 nm interval) with a Nd:YAG laser at 532 nm, with a beam energy of 25 mJ per pulse, a pulse width of 5 ns, and a repetition rate of 10 Hz. The optimum wavelength(${\lambda}nm$) of LIBS for estimating soil and plant elements were 308.2 nm for Al, 428.3 nm for Ca, 247.8 nm for T-C, 438.3 nm for Fe, 766.5 nm for K, 85.2 nm for Mg, 330.2 nm for Na, 213.6 nm for P, 180.7 nm for S, 288.2 nm for Si, and 351.9 nm for Ti, respectively. Coefficients of determination($r^2$) of calibration curve using standard reference soil samples for each element from LIBS measurement were ranged from 0.863 to 0.977. In comparison with ICP-AES(Inductively coupled plasma atomic emission spectroscopy) measurement, measurement error in terms of relative standard error were calculated. Silicon dioxide(SiO2) concentration estimated from two methods showed good agreement with -3.5% of relative standard error. The relative standard errors for the other elements were high. It implies that the prediction accuracy is low which might be caused by matrix effect such as particle size and constituent of soils. It is necessary to enhance the measurement and prediction accuracy of LIBS by improving pretreatment process, standard reference soil samples, and measurement method for a reliable quantification method.

Study for Residue Analysis of Herbicide, Clopyralid in Foods (식품 중 제초제 클로피랄리드(Clopyralid)의 잔류 분석법)

  • Kim, Ji-young;Choi, Yoon Ju;Kim, Jong Su;Kim, Do Hoon;Do, Jung Ah;Jung, Yong Hyun;Lee, Kang Bong;Kim, Hyo Chin
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.283-290
    • /
    • 2018
  • BACKGROUND: Pesticide residue analysis is an essential activity in order to establish the food safety of agricultural products. Analytical approaches to the food safety are required to meet internationally the guideline of Codex (Codex Alimentarius Commission, CAC/GL 40). In this study, we developed a liquid chromatograph-tandem mass spectrometer (LC-MS/MS) method to determine the herbicide clopyralid in food matrixes. METHODS AND RESULTS: Clopyralid was extracted with aqueous acetonitrile containing formic acid and the extracts were mixed in a citrate buffer consisted of magnesium sulfate anhydrous, NaCl, sodium citrate dihydrate and disodium hydrogencitrate sesquihydrate followed by centrifugation. The supernatants were filtered through a nylon membrane filter and used for the analysis of clopyralid. The method was validated by accuracy and precision experiments on the samples fortified at 3 different levels of clopyralid. LC-MS/MS in positive mode was employed to quantitatively determine clopyralid in the food samples. Matrix-matched calibration curves were inearranged from 0.001 to 0.25 mg/kg with r2 > 0.994. The limits of detection and quantification were determined to be 0.001 and 0.01 mg/kg, respectively. There covery values of clopyralid for tified at 0.01 mg/kg in the control samples ranged from approximately 82 to 106% with relative standard deviations below 2 0%. CONCLUSION: The method developed in this study meets successfully the Codex guideline for pesticide residue analysis in food samples. This, the method could be applicable to determine pesticides in foods produced domestically and internationally.

Simultaneous Multicomponent Analysis of Preservatives in Cosmetics by Gas Chromatography (GC를 이용한 화장품 살균·보존제의 다성분 동시분석법)

  • Cho, Sang Hun;Jung, Hong Rae;Kim, Young Sug;Kim, Yang Hee;Park, Eun Mi;Shin, Sang Woon;Eum, Kyoung Suk;Hong, Se Ra;Kang, Hyo Jeong;Yoon, Mi Hye
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.1
    • /
    • pp.69-75
    • /
    • 2019
  • Preservatives of cosmetics is managed by positive list in Korea. Positive list requires a proper quantitative analysis method, but the analysis method is still insufficient. In this study, gas chromatography with flame ionization detector was used to simultaneously analyze 14 preservatives in cosmetics. As a result of method validation, the specificity was confirmed by the calibration curves of 14 preservatives showing good linearity correlation coefficient of above 0.9997 except dehydroacetic acid (0.9891). The limits of detection (LOD) and quantification (LOQ) of 14 preservatives were 0.0001 mg/mL ~ 0.0039 mg/mL and 0.0003 mg/mL ~ 0.0118 mg/mL, respectively, but they were 0.0204 mg/mL, 0.0617 mg/mL for dehydroacetic acid, respectively. The precision (Repeatability) of the values was less than 1.0%, but 7.1% for dehydroacetic acid. The Accuracy (% recovery) of 14 preservatives in cosmetics showed 96.9% ~ 109.2%. Finally, this method was applied to 50 cosmetics available in market. Results showed that the commonly used preservatives were chlorophene, phenoxyethanol, benzyl alcohol and parabens. However, the amount of the detected preservatives was within maximum allowed limits established by KFDA.

Development and Validation of Analytical Method and Antioxidant Effect for Berberine and Palmatine in P.amurense (황백의 지표성분 berberine과 palmatine의 분석법 개발과 검증 및 항산화 효능 평가)

  • Jang, Gill-Woong;Choi, Sun-Il;Han, Xionggao;Men, Xiao;Kwon, Hee-Yeon;Choi, Ye-Eun;Park, Byung-Woo;Kim, Jeong-Jin;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.6
    • /
    • pp.544-551
    • /
    • 2020
  • The aim of this study was to develop and validate a simultaneous analytical method for berberine and palmatine, which are representative substances of Phellodendron amurense, and to evaluate the antioxidant activity. We evaluated the specificity, linearity, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of analytical methods for berberine and palmatine using high-performance liquid chromatography. Our result showed that the correlation coefficients of the calibration curve for berberine and palmatine exhibited 0.9999. The LODs for berberine and palmatine were 0.32 to 0.35 µg/mL and the LOQs were 0.97 to 1.06 µg/mL, respectively. The inter-day and intra-day precision values for berberine and palmatine were from 0.12 to 1.93 and 0.19 to 2.89%, respectively. The inter-day and intra-day accuracies were 98.43-101.45% and 92.39-100.60%, respectively. In addition, the simultaneous analytical method was validated for the detection of berberine and palmatine. Moreover, we conducted FRAP and NaNO2 scavenging activity assays to measure the antioxidant activities of berberine and palmatine, and both showed antioxidant activity. These results suggest that P.amurense could be a potential natural resource for antioxidant activity and that the efficacy can be confirmed by investigating the content of the berberine and palmatine.

Development of simultaneous analytical method for investigation of ketamine and dexmedetomidine in feed (사료 내 케타민과 덱스메데토미딘의 잔류조사를 위한 동시분석법 개발)

  • Chae, Hyun-young;Park, Hyejin;Seo, Hyung-Ju;Jang, Su-nyeong;Lee, Seung Hwa;Jeong, Min-Hee;Cho, Hyunjeong;Hong, Seong-Hee;Na, Tae Woong
    • Analytical Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.136-142
    • /
    • 2022
  • According to media reports, the carcasses of euthanized abandoned dogs were processed at high temperature and pressure to make powder, and then used as feed materials (meat and bone meal), raising the possibility of residuals in the feed of the anesthetic ketamine and dexmedetomidine used for euthanasia. Therefore, a simultaneous analysis method using QuEChERS combined with high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry was developed for rapid residue analysis. The method developed in this study exhibited linearity of 0.999 and higher. Selectivity was evaluated by analyzing blank and spiked samples at the limit of quantification. The MRM chromatograms of blank samples were compared with those of spiked samples with the analyte, and there were no interferences at the respective retention times of ketamine and dexmedetomidine. The detection and quantitation limits of the instrument were 0.6 ㎍/L and 2 ㎍/L, respectively. The limit of quantitation for the method was 10 ㎍/kg. The results of the recovery test on meat and bone meal, meat meal, and pet food showed ketamine in the range of 80.48-98.63 % with less than 5.00 % RSD, and dexmedetomidine in the range of 72.75-93.00 % with less than 4.83 % RSD. As a result of collecting and analyzing six feeds, such as meat and bone meal, prepared at the time the raw material was distributed, 10.8 ㎍/kg of ketamine was detected in one sample of meat and bone meal, while dexmedetomidine was found to have a concentration below the limit of quantitation. It was confirmed that the detected sample was distributed before the safety issue was known, and thereafter, all the meat and bone meal made with the carcasses of euthanized abandoned dogs was recalled and completely discarded. To ensure the safety of the meat and bone meal, 32 samples of the meat and bone meal as well as compound feed were collected, and additional residue investigations were conducted for ketamine and dexmedetomidine. As a result of the analysis, no component was detected. However, through this investigation, it was confirmed that some animal drugs, such as anesthetics, can remain without decomposition even at high temperature and pressure; therefore, there is a need for further investigation of other potentially hazardous substances not controlled in the feed.

Analysis of Aminoglycoside Antibiotics in Meat and Cell Culture Medium Coupled with Direct Injection of an Ion-pairing Reagent (이온쌍 시약 직접 주입법을 활용한 육류 및 세포배양액 내 아미노글리코사이드계 항생제 분석)

  • Kyung-Ho Park;Song-Yi Gu;Geon-Woo Park;Jong-Jib Kim;Jong-soo Lee;Sang-Gu Kim;Sang-Yun Lee;Hyang Sook Chun
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.319-331
    • /
    • 2023
  • Aminoglycoside antibiotics, also known as aminoglycosides (AGs), are veterinary drugs effective against a wide range of gram-negative and gram-positive bacteria. Owing to their recent use in cultured meats, it has become essential to establish an analytical method for safety management. AGs are highly polar compounds, and ion-pair reagents (IPRs) are used to ensure component separation. Owing to the high possibility of potential mechanical problems resulting from IPR addition to the mobile phase, an analytical method in which IPRs are added directly to the vial was explored. In this study, methods for analyzing 10 AGs via liquid chromatography-tandem mass spectrometry (LC-MS/MS) with the addition of two IPRs were validated for selectivity, detection limit, quantitation limit, recovery, and precision. The detection limit was 0.0001-0.0038 mg/kg, the quantification limit was 0.004-0.011 mg/kg, and the linearity (R2) within the concentration range of 0.01-0.5 mg/kg was over 0.99. Recovery and precision (expressed as relative standard deviation) evaluated in the two matrices (beef and cell culture media) ranged from 70.7% to 120.6% and 0.2% to 24.7%, respectively. The validated AG analytical method was then applied to 15 meats prepared from chicken, beef, and pork, and 6 culture media and additives used in cultured meat. No AGs were detected in any of the 15 meats distributed in Korea; however, streptomycin and dihydrostreptomycin were detected at levels ranging from 695.85 to 1152.71 mg/kg and 6.35 to 11.11 mg/kg, respectively, in the culture media additives. The LC-MS/MS method coupled with direct addition of IPRs to the vial can provide useful basic data for AG analysis and safety evaluation of meats as well as culture media and additives for cultured meats.

A Refined Method for Quantification of Myocardial Blood Flow using N-13 Ammonia and Dynamic PET (N-13 암모니아와 양전자방출단층촬영 동적영상을 이용하여 심근혈류량을 정량화하는 새로운 방법 개발에 관한 연구)

  • Kim, Joon-Young;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Ju, Hee-Kyung;Kim, Yong-Jin;Kim, Byung-Tae;Choi, Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.73-82
    • /
    • 1997
  • Regional myocardial blood flow (rMBF) can be noninvasively quantified using N-13 ammonia and dynamic positron emission tomography (PET). The quantitative accuracy of the rMBF values, however, is affected by the distortion of myocardial PET images caused by finite PET image resolution and cardiac motion. Although different methods have been developed to correct the distortion typically classified as partial volume effect and spillover, the methods are too complex to employ in a routine clinical environment. We have developed a refined method incorporating a geometric model of the volume representation of a region-of-interest (ROI) into the two-compartment N-13 ammonia model. In the refined model, partial volume effect and spillover are conveniently corrected by an additional parameter in the mathematical model. To examine the accuracy of this approach, studies were performed in 9 coronary artery disease patients. Dynamic transaxial images (16 frames) were acquired with a GE $Advance^{TM}$ PET scanner simultaneous with intravenous injection of 20 mCi N-13 ammonia. rMBF was examined at rest and during pharmacologically (dipyridamole) induced coronary hyperemia. Three sectorial myocardium (septum, anterior wall and lateral wall) and blood pool time-activity curves were generated using dynamic images from manually drawn ROIs. The accuracy of rMBF values estimated by the refined method was examined by comparing to the values estimated using the conventional two-compartment model without partial volume effect correction rMBF values obtained by the refined method linearly correlated with rMBF values obtained by the conventional method (108 myocardial segments, correlation coefficient (r)=0.88). Additionally, underestimated rMBF values by the conventional method due to partial volume effect were corrected by theoretically predicted amount in the refined method (slope(m)=1.57). Spillover fraction estimated by the two methods agreed well (r=1.00, m=0.98). In conclusion, accurate rMBF values can be efficiently quantified by the refined method incorporating myocardium geometric information into the two-compartment model using N-13 ammonia and PET.

  • PDF