• Title/Summary/Keyword: Quality evaluation

Search Result 14,131, Processing Time 0.07 seconds

Estimating Forest Site Productivity and Productive Areas of Quercus acutissima and Quercus mongolica Using Environmental Variables (환경요인에 의한 상수리나무와 신갈나무의 임지생산력 및 적지 추정)

  • Shin, Man-Yong;Sung, Joo-Han;Chun, Jung-Hwa
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.2
    • /
    • pp.89-97
    • /
    • 2012
  • This study was conducted to estimate forest site productivity and productive areas of Quercus acutissima and Quercus mongolica using environmental factors including climatic variables. Using the data set from digital forest site map and forest climatic map, a total of 42 environmental variables were regressed on site index for developing the best site index equations for Quercus acutissima and Quercus mongolica. Five to six environmental factors by species were selected as independent variables in the best site index equations. For the site index equations, three evaluation statistics (i.e., mean difference, standard deviation of difference, and standard error of difference) were applied to the test data set for the validation of the results, The site index equations fitted well to the test data set with relatively low bias and variation. As a result, it was concluded that the site index equations by species were well capable of estimating site quality. Finally, based on the site index equations, the productive areas by species were estimated by applying GIS technique to the digital forest maps. In addition, the distribution of productive areas by species was illustrated.

Closed Static Chamber Methods for Measurement of Methane Fluxes from a Rice Paddy: A Review (벼논 메탄 플럭스 측정용 폐쇄형 정적 챔버법: 고찰)

  • Ju, Okjung;Kang, Namgoo;Lim, Gapjune
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.2
    • /
    • pp.79-91
    • /
    • 2020
  • Accurate assessment of greenhouse gas emissions is a cornerstone of every climate change response study, and reliable assessment of greenhouse gas emission data is being used as a practical basis for the entire climate change prediction and modeling studies. Essential, fundamental technologies for estimating greenhouse gas emissions include an on-site monitoring technology, an evaluation methodology of uncertainty in emission factors, and a verification technology for reductions. The closed chamber method is being commonly used to measure gas fluxes between soil-vegetation and atmosphere. This method has the advantages of being simple, easily available and economical. This study presented the technical bases of the closed chamber method for measuring methane fluxes from a rice paddy. The methane fluxes from rice paddies occupy the largest portion of a single source of greenhouse gas in the agricultural field. We reviewed the international and the domestic studies on automated chamber monitoring systems that have been developed from manually operated chambers. Based on this review, we discussed scientific concerns on chamber methods with a particular focus on quality control for improving measurement reliability of field data.

Implementation of Analysis System for H.323 Traffic (H.323 트래픽 분석 시스템의 개발)

  • Lee Sun-Hun;Chung Kwang-Sue
    • The KIPS Transactions:PartC
    • /
    • v.13C no.4 s.107
    • /
    • pp.471-480
    • /
    • 2006
  • Recently, multimedia communication services, such as video conferencing and voice over IP, have been rapidly spread. H.323 is an international standard that specifies the components, protocols and procedures that provide multimedia communication services of real-time audio, video, and data communications over packet networks, including IP based networks. H.323 is applied to many commercial services because it supports various network environments and has a good performance. But communication services based on H.323 may have some problem because of current network trouble or mis-implementation of H.323. The understanding of this problem is a critical issue because it improves the quality of service and is easy to service maintenance. In this paper, we implement the analysis system for H.323 protocol wihch includes H.245, H.225.0, RTP, RTCP, and so on. Tills system is able to capture, parse, and present the H.323 protocol in real-time. Through the operation test and performance evaluation, we prove that our system is a useful to analyze and understand the problems for communication services based on H.323.

A Study of the Selection of the Valuation Items of the Environmental Illumination Design for a Bridge (교량의 경관조명연출디자인 평가항목 도출에 관한 연구)

  • Cho, Hyun-Choul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.22-30
    • /
    • 2004
  • It is an attempt to suggest the standard valuation method of the environmental illumination for the bridges across the Han-river from an aesthetic point of view, deviating from the technical and traditional viewpoint. In Korea the current evaluation criterion to verify the value of bridge design has a partiality for the technical and structural safety rather than the sentient beauty on the whole. However, the recently cultural reform of Korean mass society with the elevation of the standard of living forces the engineering designers for bridges to focus not only on competing physical structures but also on enhancing the formative beauty including the illumination effects for night view. Additionally, the new policy, which transforms the environments around the Han-river into the major tourist attractions has been executing strongly by the city authorities to revitalize the symbolic, historic, and cultural identity of the capital city with the introduction of the high-quality environmental illumination for the bridges. As a result, It becomes necessary to establish the manual and standardization of the environmental illumination planning for the city in terms of the formative beauty, and this study is to suggest the valuation model method of the environmental illumination for the bridges as the initial step of the standardization. In the study, the valuation items of the standard questionnaire are selected by the documentary records and the consultation of various experts in architecture, design, fine art, urban planning and even administration to verify the essential elements of the aesthetic beauty with the local amenity and the environmental harmony for the chosen bridges across the Han-river.

The Property Evaluation of the Marine Concrete Structure Constructed in the Period of Japanese Occupancy (YoungDo Bridge) (일제시대 건설된 해양 콘크리트구조물의 물성 평가(영도대교))

  • Park, Dong-Cheon;Ahn, Jae-Cheol
    • Journal of Navigation and Port Research
    • /
    • v.37 no.2
    • /
    • pp.165-171
    • /
    • 2013
  • YoungDo bridge is the first suspension bridge in Busan which experienced several times repair and reinforcement after completion in 1934. The bridge is under demolition for extension and restoration work since 2011. The purpose of this research is to establish data base about modern concrete. The mix design of the concrete is like that cement : fine aggregate : coarse aggregate = 1 : 2 : 4 or 1 : 3 : 6 by the parts. The compressive strength is in the ranges from 50 to 55 MPa and the elastic modulus is in the ranges from 25 to 35 GPa. From the fact that the deviation is less than 10 %, considerably high quality control was conducted in those days. The carbonation depth is 5.92 cm at the bridge post and 14.3 cm at the machine room. That is why ocean environment keeps the high humidity. The diffusion coefficient of chloride ion through the pores in concrete is 1.052e-12 $m^2/s$ from the regression analysis using the experiment data. The water cement ration is estimated at approximately 35 % in case if the concrete using ordinary Portland cement.

Experimental Performance Evaluation on V-shaped Butt Welding Using GMA Welding Double Wire Reel and Remote Control Torch Welding Technique (GMAW 더블 와이어 릴, 원격제어토치 용접기술을 이용한 V형 맞대기 용접 부의 실험적 성능 평가)

  • Kim, Jeong-Hyeok;Oh, Seck-Hyeog;Lee, Hae-Gil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1339-1347
    • /
    • 2015
  • This study discusses a remote control torch system equipped with a GMAW double wire reel. The welding machine is 30m away from the wire feeder at the industrial site and the feeder is three to five meters away from the torch. Accordingly, the welders cannot control the current and voltage that meets the welding condition during work when they are working at a place that prevents them from seeing the control panel, such as inside a vehicle or tank or at a far work site. They also have no choice but to stop working to change the wire reel when it is burned out completely. Such work suspension resulting from frequent moves to adjust the current and voltage as well as to replace the wire and subsequent cooling causes welding defects. This study produced a remote control torch equipped with a double wire reel by simplifying and streamlining the existing GMAW functions to reduce the troubling issue. The remote control torch equipped with a double wire reel and the existing $CO_2$ /MAG welding torch were applied as a V-groove butt in the vertical position using 6mm rolled steel for a SM50A welding structure. After welding, the condition of welded surface beads underwent a visual inspection and radiographic inspection to analyze the welding quality inside the welded part. This study also evaluated the reduction of welding defects, cost saving, the replacing performance against the existing commercial welders, and the effects on possible compatibility.

The Physical Properties of Port Type Crack Injection Method Using Latex Elastic Storage Tube (라텍스 탄성 저장관을 활용한 포트식 균열주입 공법의 물리적 특성에 관한 연구)

  • Kim, Eun-Young;Sho, Kwang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.68-75
    • /
    • 2018
  • In this study, to solve the problems of the conventional crack repair and injection method, high elasticity latex was used as the material of the storage tube to withstand the high pressure in the center part differently from the general port. When the repair solution was injected into the crack part, The TPS method was developed so that the air existing in the TPS can be discharged. In addition, a new infusion port in which a valve blocking the backflow of the remediation solution was installed at the injection port was developed and the physical characteristics of the port were analyzed. As a result of the evaluation, it was found that the filling rate of the remedial solution was improved compared to the existing ordinary injector method, and the cracks were completely filled in the test conditions. Compressive strength and tensile strength after repair showed about 20% decrease after repair in case of using ordinary injector method, while TPS method showed about 2~7% increase after repair. The results of this study showed that the injection port method using the elastic storage tube increased the injection performance and the quality after repair compared to the conventional injector method. The result of this study is expected to be utilized as the basic data for application and commercialization of the result to the practical structure.

The Integration System for International Procurement Information Processing (국제입찰정보 통합시스템의 설계 및 구현)

  • Yoon, Jong-Wan;Lee, Jong-Woo;Park, Chan-Young
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.1
    • /
    • pp.71-81
    • /
    • 2002
  • The lack of specialties of the existing commercial web search systems stems from the fact that they have no capabilities to extract and gather the meaningful information from each information domain they cover. We are sure, however, that the necessity for the information integration system, not just search system, will be likely to become larger in the future. In this paper, we propose a design and implementation of an information integration system called TIC(target information collector). TIC is able to extract meaningful information from a specific information area in the internet and integrate them for the commercial service. We also show the evaluation results of our implementation. For the experiments we applied our TIC to the international procurement information area. The international procurement information is publicly and freely announced by each government to the world. To automatically extract common properties from the related source sites, we adopt information pointing technique using inter-HTML tag pattern parsing. And through the information integration framework design, we can easily implement a site-specific information integration engine. By running our TIC for about 8 months, we find out it can remove considerable amount of the duplicated information, and as a result, we can obtain high quality international procurement information. The main contribution of this paper is to present a framework design and it's implementation for extracting the information of a specific area and then integrating them into a meaningful one.

Actual condition on accuracy control of mammography equipment in Kyeongsangbuk-do (경상북도 유방촬영장비의 정도관리에 대한 실태조사)

  • Kim, Sang-Jin;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.29-37
    • /
    • 2006
  • The breast cancer has the highest occurrence rate among the female cancers, and as the living style changes, the occurrence is increasing gradually. For the breast cancer test among women, who comprises up to 50% of the total population, the mammography is mainly used as the screening test, and the accuracy control is the most important aspect of the testing. Therefore this research divided the northern part of Kyeongsangbuk-do into 4 regions and investigated the accordance ratio of examination field and light examination field, the total focus using the optical density and compression rate, and the overall maintenance of mammography within the regions. The equipments of 11 hospitals were investigated, and the 7 hospitals passed the standard level of the accordance ratio of examination field. 6 hospitals passed the standard optical density, and 7 hospitals had the passing performance in the compression rate. Fibers, group of specks, and masses within the Mammographic Accreditation Phantom scored 10, being within the standard range. However, only 3 hospitals were equipped with private development processor and illumination. The result reflects the fact that the image quality of breast is not correctly being maintained. Moreover, only 27.27% satisfied all the three categories of compression fitting, accordance ratio of examination field, and phantom image evaluation at the same time. The accuracy control must be maintained more precisely for the accurate diagnosis of breast cancer.

  • PDF

Study on Energy Performance And Economic Evaluation of Windows System with Built-in Type Blinds (블라인드 내장형 창호시스템의 에너지 성능 및 경제성 평가에 관한 연구)

  • Joe, Won-Hwa;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.2
    • /
    • pp.97-104
    • /
    • 2010
  • This study evaluated the energy efficiency of a windows system using built-in blinds, with regard to their insulation performance and their blocking of solar radiation. The study took advantage of the "Physibel Voltra" program as a physical simulation of heat transfer. To simulate the "Physibel Voltra" program, I practiced a mock-up test to determine heating quality and translation condition. I analyzed the propensity to annual energy consumption, the annual quantity of heat transfer, and the annual cooling and heating cost through a computer simulation for one general household in an apartment building. In the test, it was found that compared to a general windows system, a windows system with built-in blinds reduced the annual heat transfer by 10% in cooling states and by 11% in heating states when the blind was up. When the blind was down, the windows system with built-in blinds reduced the annual heat transfer by 25% in cooling states and 30% in heating states. When a windows system with built-in blinds is compared with a general windows system, the quantity of cooling and heating loads is reduced by 283.3kw in cooling states and 76.3kw in heating states. This leads to a reduction in the required cooling and heating energy of 359.6kw per house. It is thus judged that the use of a windows system with built-in blinds is advantageous in terms of reducing greenhouse gas emissions, because the annual TOE (tons of oil equivalent) per house is reduced by 0.078TOE, while $tCO_2$ is reduced by $0.16tCO_2$. In addition, compared with a general windows system, the cost of cooling and heating loads in the system reduces the annual cooling cost by 100,000won, and the annual heating cost by 50,000won. Ultimately, this means that cooling and heating loads are cut by 150,000won per year.