• Title/Summary/Keyword: Quality Measurement Method

Search Result 1,469, Processing Time 0.022 seconds

A Method of an Accurate Six Sigma Financial Effect Measurement and Connecting the Financial Effect to the Corporate Income Performance (6시그마 재무성과의 정확한 측정과 기업 손익실적과의 연계 방안)

  • Kim, Ho-In;Jeong, Jae-Ho;Kim, Chan-Mo
    • Journal of Korean Society for Quality Management
    • /
    • v.37 no.3
    • /
    • pp.94-101
    • /
    • 2009
  • It is important to measure financial effect of six sigma projects accurately for successful implementation of six sigma in a company. However, researches on methods of six sigma financial effect measurement are relatively new. In this study, frequent error patterns of six sigma financial effect measurement are defined and accurate measurement methods are suggested. And a method of connecting six sigma financial effect to corporate income performance is also suggested which not only assures reliability of financial effect measurement but also helps to align with business strategy.

Study on establish for unit of measure for Quality Feature (다구찌의 품질특성 측정에 대한 고찰과 사례 연구)

  • Park, No-Guk;Lee, Sang-Bok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.04a
    • /
    • pp.163-172
    • /
    • 2013
  • In this Paper, We study on establish for unit of measure. Quality means abstract for customer needs. we surveyed unit of measurement of quality feature of Juran, Taguchi, 6 sigma method. We suggest unit of measurement of quality feature. Each enterprise can use defining own unit of measurement of quality feature. Effect is expected in enterprise that these proposals do quality control. There is meaning in direction that measuring mean of quality feature that propose in this treatise understands actuality to be deeply and reconcile exact point of theory.

  • PDF

Study on establish for unit of measure for Quality Feature (품질 특성의 측정에 대한 분석 사례 연구)

  • Lee, Hui-Chun;Park, No-Guk;Lee, Sang-Bok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.157-165
    • /
    • 2011
  • In this Paper, We study on establish for unit of measure. Quality means abstract for customer needs. we surveyed unit of measurement of quality feature of Juran, Taguchi, 6 sigma method. We suggest unit of measurement of quality feature. Each enterprise can use defining own unit of measurement of quality feature. Effect is expected in enterprise that these proposals do quality control. There is meaning in direction that measuring mean of quality feature that propose in this treatise understands actuality to be deeply and reconcile exact point of theory.

  • PDF

A Study of Matrix Model for Core Quality Measurement based on the Structure and Function Diagnosis of IoT Networks (구조 및 기능 진단을 토대로 한 IoT네트워크 핵심품질 매트릭스 모델 연구)

  • Noh, SiChoon;Kim, Jeom Goo
    • Convergence Security Journal
    • /
    • v.14 no.7
    • /
    • pp.45-51
    • /
    • 2014
  • The most important point in the QoS management system to ensure the quality of the IoT system design goal is quality measurement system and the quality evaluation system. This research study is a matrix model for the IoT based on key quality measures by diagnosis system structure and function. Developing for the quality metrics measured Internet of Things environment will provide the foundation for the Internet of Things quality measurement/analysis. IoT matrix system for quality evaluation is a method to describe the functional requirements and the quality requirements in a single unified table for quality estimation performed. Comprehensive functional requirements and quality requirements by assessing the association can improve the reliability and usability evaluation. When applying the proposed method IoT quality can be improved while reducing the QoS signaling, the processing, the basis for more efficient quality assurances as a whole.

A Method for Generation of Grinding Map based on Automatic Mold Measurement (금형 자동측정에 의한 사상맵 생성)

  • Jeoung, Nam-Yeoung;Cho, Jin-Hyung;Oh, Hyun-Seung;Lee, Sae-Jae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.248-255
    • /
    • 2018
  • Ensuring the quality of molds is one of the major issues in mass production. In general, securing the quality of the molds is achieved by repeating grinding and die spotting after machining the molds based on engineer's decision. However, this heuristic method is affected by the engineer's skill and working environment. Therefore, a lot of time and resources are needed in order to ensure quality. In this study, ensuring the quality of molds using grinding map which is generated using automatic measurement is proposed. An automatic measuring system based on CMM (Coordinate Measuring Machine) is developed for measuring the molds. This system generates the measurement path automatically using the 3D CAD model of products. CAD (ComputerAided-Design), CAM (Computer-Aided-Manufacturing), and CAQ (Computer-Aided-Quality) technology is integrated using DMIS (Dimensional Measuring Interface Standard) format in the automatic measuring system. After measuring the molds, a grinding map is generated using the gap between the CAD model and measured values of mold. The grinding map displays the machining tendency and the required amount of grinding with values on a 3D map. Therefore, the quality of molds can be ensured with exactness and quickness based on the grinding map. This study shows that integrating the planning, measuring, and analyzing based on computer technology can solve the problem of quality assurance of mold using the proposed method, therefore the productivity can be increased.

Estimations of Measurement System Variability and PTR under Non-normal Measurement Error (비정규 측정오차의 경우 측정시스템 변동과 PTR 추정)

  • Chang, Mu-Seong;Kim, Sang-Boo
    • Journal of Korean Society for Quality Management
    • /
    • v.35 no.1
    • /
    • pp.10-19
    • /
    • 2007
  • ANOVA is widely, used for measurement system analysis. It assumes that the measurement error is normally distributed, which nay not be seen in some industrial cases. In this study the estimates of the measurement system variability and PTR (precision-to-tolerance ratio) are obtained by using weighted standard deviation for the case where the measurement error is non-normally distributed. The Standard Bootstrap method is used foy estimating confidence intervals of measurement system variability and PTR. The point and confidence interval estimates for the cases with normally distributed measurement error are compared to those with non-normally distributed measurement errors through computer simulation.

A Study on Quantitative Measurement of Metadata Quality for Journal Articles (학술지 기사에 대한 메타데이터 품질의 계량화 방법에 관한 연구)

  • Lee, Yong-Gu;Kim, Byung-Kyu
    • Journal of the Korean Society for information Management
    • /
    • v.28 no.1
    • /
    • pp.309-326
    • /
    • 2011
  • Most metadata quality measurement employ simple techniques by counting error records. This study presents a new quantitative measurement of metadata quality using advanced weighting schemes in order to overcome the limitations of exiting measurement techniques. Entropy, user tasks, and usage statistics were used to calculate the weights. Integrated weights were presented by combining these weights and were applied to actual journal article metadata. Entropy weights were found to reflect the characteristics of the data itself. User tasks presented the required metadata elements to solve user's information need. Integrated weights showed balanced measures without being affected by the influence of error elements, This finding indicates the new method being suitable for quantitative measurement of metadata quality.

Evaluating LIMU System Quality with Interval Evidence and Input Uncertainty

  • Xiangyi Zhou;Zhijie Zhou;Xiaoxia Han;Zhichao Ming;Yanshan Bian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.11
    • /
    • pp.2945-2965
    • /
    • 2023
  • The laser inertial measurement unit is a precision device widely used in rocket navigation system and other equipment, and its quality is directly related to navigation accuracy. In the quality evaluation of laser inertial measurement unit, there is inevitably uncertainty in the index input information. First, the input numerical information is in interval form. Second, the index input grade and the quality evaluation result grade are given according to different national standards. So, it is a key step to transform the interval information input by the index into the data form consistent with the evaluation result grade. In the case of uncertain input, this paper puts forward a method based on probability distribution to solve the problem of asymmetry between the reference grade given by the index and the evaluation result grade when evaluating the quality of laser inertial measurement unit. By mapping the numerical relationship between the designated reference level and the evaluation reference level of the index information under different distributions, the index evidence symmetrical with the evaluation reference level is given. After the uncertain input information is transformed into evidence of interval degree distribution by this method, the information fusion of interval degree distribution evidence is carried out by interval evidential reasoning algorithm, and the evaluation result is obtained by projection covariance matrix adaptive evolution strategy optimization. Taking a five-meter redundant laser inertial measurement unit as an example, the applicability and effectiveness of this method are verified.

Development of a Method for Measuring Image Quality of Intra Vascular Ultrasound Images using Image Analysis Program (영상 분석 프로그램을 이용한 혈관 내 초음파 영상의 화질 측정 방법 고안)

  • Seo, Young-Hyun;Han, Jae-Bok;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.621-628
    • /
    • 2021
  • Prior studies on frequency-related image quality analysis of intravascular ultrasound catheters are lacking both in Korea and abroad. Therefore, this study was conducted to prepare a standard for measuring the image quality using the program and to suggest a measuring method to researchers related to the quality analysis of intravascular ultrasound images. For the target, the vessel lumen size is 3.0 - 4.0 mm. Before using intravascular ultrasound, thoroughly clean the ultrasound catheter so that no air or foreign substances enter it. Normal vascular images and lesion vascular images of sufficiently dilated images were used. As a standard image acquisition method, the image of the end-systolic section, which has the best evaluation of vascular lesions when using intravascular ultrasound, was acquired retrospectively through the DCAS PACS program to set the standard. When setting the measurement method criteria, we proposed a standard setting method that corresponds to the concentric and eccentric circles of normal and lesion vessels. By applying this criterion, we proposed a method for measuring the lumen and lateral cavities of normal and lesion vessels of interest and background area. In conclusion, if the image quality of intravascular ultrasonography is measured through the method devised by these researchers, consistent quality measurement is possible regardless of the type of intravascular ultrasound catheter. Therefore, it is thought that it can be applied as a guideline for the actual image quality measurement method in the study related to intravascular ultrasound image quality.

Two-dimensional Spatial Distribution Analysis Using Water Quality Measurement Results at River Junctions (하천 합류부에서의 수질계측결과를 활용한 2차원 공간분포 해석)

  • Lee, Chang Hyun;Park, Jae Gon;Kim, Kyung Dong;Ryu, Si Wan;Kim, Dong Su;Kim, Young Do
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.343-350
    • /
    • 2022
  • High-resolution data are needed to understand water body mixing patterns at river junctions. In particular, in river analysis, hydrological and water quality characteristics are used as basic data for aquatic ecological health, so observation through continuous monitoring is necessary. In addition, since measurement is carried out through a one-dimensional and fixed measurement method in existing monitoring systems, a hydrological and water quality characteristics investigation of an entire river, except for in the immediate vicinity of the measurement point, is not undertaken. In order to obtain high-resolution measurement data, a measurer has to consider multiple factors, and the area or time that can be measured is limited. Although the resolution might be lowered, an appropriate interpolation method must be selected in order to acquire a wide range of data. Therefore, in this study, a high-elevation measurement method at a river junction was introduced, and the interpolation method according to the measurement results was compared. The overall hydraulic and water quality information of the river was indicated through the visualization of the prediction and interpolation method in the low-resolution measurement result. By comparing each interpolation method, Inverse Distance Weighting, Natural Neighbor, and Kriging techniques were applied in river mapping to improve the precision of river mapping through visualized data and quantitative evaluation. It is thought that this study will offer a new method for measuring rivers through spatial interpolation.