• Title/Summary/Keyword: Quality Diagnostic

Search Result 857, Processing Time 0.025 seconds

Bacterial contaminants in extended boar semen and selection of effective antimicrobials (돼지 희석정액의 세균오염도 및 유효 항생제 선발)

  • Kim, Ha-Young;Byun, Jae-Won;Shin, Dong-Ho;Kim, Hyoung-Soon;Yoon, Hachung;Park, Choi-Kyu;Lee, O-Soo;Jung, Byeong Yeal
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.2
    • /
    • pp.125-131
    • /
    • 2010
  • Bacterial contamination is an unavoidable finding of the semen collection process in boar and can lead in deleterious effects on semen quality and longevity if left uncontrolled. The purpose of this study is to identify the bacteria in extended boar semen and to select the effective antimicrobials to control of the contaminants. Of 116 extended boar semen samples submitted from eight AI centers in Korea, 39 (33.6%) samples were positive for bacterial contamination. Among 39 contaminated semen, most of them (84.6%) were contaminated with one or two bacterial species and there was no significant difference between two age groups $(\leq\;24\;and\;>\;24\;month\;old).$ Stenotrophomonas maltophilia (n = 18) was the most predominant bacterium followed by Elizabethkingia meningoseptica (n = 12), Sphingomonas paucimobilis (n = 12), Myroides spp. (n = 5), Ochrobactrum anthropi (n = 3), and so on. Enrofloxacin (72.9%), florfenicol (72.9%), bacitracin (49.2%) and tylosin (49.2%) showed higher sensitivity compared with penicillin (13.6%) or aminoglycosides (6.8%-18.6%). Brucella spp., Leptospira spp., Mycoplasma hyopneumoniae, Mycoplasma hyorhinis, Mycobacterium tuberculosis complex were not detected in semen by PCR.

Diagnostic Accuracy of Clinical Test for Anterior Cruciate Ligament Injury: Systematic Review

  • Deniz Yasemin;Sang-Woo Pyun;HyungSu Lee;Seong-Eun Kim;SunGyu Han;Dongyeop Lee;Ji-Heon Hong;Jae-Ho Yu;Jin-Seop Kim;Seong-gil Kim
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.3
    • /
    • pp.57-63
    • /
    • 2023
  • Purpose: The aim of this study was to conduct a systematic review of randomized controlled studies from 2012 to present that explore the diagnostic accuracy of clinical tests used for diagnosing anterior cruciate ligament (ACL) injury. Methods: Study design: Systematic review. Literature search of the PubMed and Scholar databases was conducted using keywords related to diagnostic accuracy of clinical tests for ACL injury. The PRISMA Guidelines were followed to conduct this study. The Cochrane Risk of Bias Tool was utilized to assess the quality of each included study. Results: As a result, 8 studies were included, and 6 clinical tests used in ACL tears were evaluated for diagnostic accuracy. The pivot shift test was reported as having the highest +LR (29.5) value with a sensitivity of 59% and a specificity of 98%. However, the test with the lowest -LR value was the lever test, and the values were as follows: -LR (0.08), +LR (4.7), specificity (80%), sensitivity (94%). Conclusion: In this study, it was concluded that a single clinical test is not sufficient to determine the presence of ACL injury. Test combinations have a higher diagnostic accuracy than a single test. In this study, the accuracy of the clinical tests was examined without considering the amount of ACL rupture and acute-chronic condition. Further research is required to examine the impact of these two factors on diagnostic accuracy of clinical test.

Comparison of Clinical and Psychological Characteristics between Self-Reported Bruxism and Clinically Detected Bruxism by Wear Facet on Splint

  • Shim, Young-Joo;Kang, Jin-Kyu;Lee, You-Mee;Lim, Hyun-Dae
    • Journal of Oral Medicine and Pain
    • /
    • v.40 no.4
    • /
    • pp.140-145
    • /
    • 2015
  • Purpose: Bruxism is commonly considered a major risk factor for temporomandibular disorders (TMD), and the psychosocial factors had been one of the etiologic factor of bruxism. But there are still unsolved issues on the relationship between sleep bruxism and TMD and the etiologic factors of bruxism. This study is aim to evaluate the clinical and psychosocial characteristics according to diagnostic grade of bruxism in TMD patients. Methods: Three hundred subjects were enrolled who were under the stabilization splint therapy for TMD. Recently international consensus proposed a diagnostic grading system of "possible", "probable", and "definite" sleep or awake bruxism for clinical and research purpose. According to their suggestion, we classified these subjects as self-reported bruxism (SRB) and wear facet bruxism (WFB). We investigated the clinical characteristics (sex, age, chief complaint, pain duration, visual analogue scale), sum of tenderness (temporomandibular joint, masticatory muscles, cervical muscles), diagnosis of TMD according to research diagnostic criteria (the Research Diagnostic Criteria for Temporomandibular Disorders, RDC/TMD), headache, subjective sleep quality (Pittsburgh Sleep Quality Index, PSQI), and psychosocial characteristics (Symptom Checklist-90-Revised, SCL-90-R) in enrolled subjects. We compared the clinical and psychosocial characteristics between these bruxism groups. Results: There were no significant correlation between self-reported and WFB (p=0.13). SRB subjects more reported pain as a chief complain than subject who did not report bruxism (p=0.014). The mean score of global PSQI was significantly higher in SRB than in did not report positively subjects (p=0.045). The mean score of anxiety and phobic anxiety was significantly higher in SRB than in did not reported positively subjects (p=0.045, p=0.041). Conclusions: Although bruxism is regarded as risk factor of TMD, this study showed inconsistent result between SRB and clinically detected bruxism by wear facet on slpint. We suggest that the clinician should consider with extreme caution when they assess SRB.

Characteristics of Insulation Failure in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 절연파괴 특성)

  • Kim, Hee-Dong;Kim, Kyeong-Yeol;Park, Deok-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.124-124
    • /
    • 2010
  • Diagnostic tests were performed on six high voltage motors. These tests included ac current, dissipation factor(tan6) and partial discharge(PD) magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 1 and No.2 motors(4.16 kV) failed near rated voltage of 12.3 kV and 14.2 kV, respectively. The breakdown voltage of No.3 and No.4 motors(6.6 kV) was 17.6 kV and 17.8 kV, respectively. These motors are higher that expected for good quality coils in 6.6 kV class motors.

  • PDF

Remote Patient Monitoring System for Diagnostic Pure-tone Audiometry (순음 청력검사를 위한 원격진단 모니터링 시스템)

  • Lee, Kang-Ho;Kwon, Yeong-Eun;Kwon, Ohwon
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.289-293
    • /
    • 2019
  • This paper presents a remote patient monitoring system for diagnostic pure-tone audiometry. A pure-tone audiometer was developed for basic hearing screening; its performance was evaluated according to international standards in terms of linearity, accuracy, and total harmonic distortion. Pure-tone audiometry has a maximum hearing level of 104.9 dB HL that is comparable with other commercial products. The audiometer shows satisfactory linearity with a deviation of ${\pm}0.4dB$, an accuracy of ${\pm}0.025%$, and a total harmonic distortion (THD) of 0.21%. The remote patient monitoring systems include remote control devices based on wide area network (WAN) connections and an audiometer connected in series. Through experimentation, we successfully performed real-time diagnostic communication without delay in transferring audiometric data. This system is expected to supply domestic equipment in the audiometric market and to improve the quality of life of patients in non-clinical environments.

Research Case of Military Maintenance Depot Technology Level Diagnosis System Using Delphi Technique and CMMI (델파이 기법과 CMMI를 활용한 군 정비창 기술수준 진단체계 연구사례)

  • Jihoon Cho
    • Journal of Korean Society for Quality Management
    • /
    • v.52 no.2
    • /
    • pp.357-376
    • /
    • 2024
  • Purpose: The purpose of this study is to design an objective and comparable diagnostic system for diagnosing the technology level of military maintenance depots and verify its actual applicability. Methods: Literature Review, Capability Maturity Model Integration, Analytic Hierarchy Process. Results: Military maintenance depot maintenance quality level diagnosis items, Maintenance quality level by maintenance technology area, Guidelines for diagnosing maintenance quality level, Quality level comparison results by area and implications for improvement. Conclusion: In order to systematically evaluate the maintenance quality of military maintenance depots, this study was conducted with the goal of designing an overall maintenance quality diagnosis system, including diagnosis areas, diagnosis items, and a diagnosis score award system, by improving the existing evaluation method. In addition, the newly developed maintenance quality diagnosis system was applied to actual evaluation activities and the results were returned to members, confirming the usefulness of the developed maintenance quality diagnosis system in the field.

A Study on the Usefulness of an Examination Information Printout during Ordinary X-Ray Examinations (일반촬영 검사 시 검사안내 유인물의 유용성에 관한 고찰)

  • Kang, Sang-Oh;Hong, Seong-Kwon;Son, Seok-Ho;Lee, Min-Woo;Kim, Kyeong-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.13-20
    • /
    • 2012
  • In a normal x-ray examination, the cooperation of a patient in positioning greatly influences the improvement of work performance, the quality of the images and the reduction in time spent on the examination. An attempt was made to discover the connection between an examination information printout and the effects of the examination by informing the patient before the examination on the examination positions in order to increase the level of cooperation by the patient and by surveying the degree of satisfaction of the patient during the examination proceedings. An examination information printout was prepared on five positions that patients consider to be difficult while receiving normal x-ray examinations and were shown to 257 male and female patients between the ages of 30 to 79 who had visited this hospital between January 1 to February 29, 2012 or to a person who had accompanied the patients before the examination to research the degree of satisfaction regarding the printout. In addition, the examination explanation printout was given to Radiologic Technologists with over 1 year experience in this hospital to use while taking the x-rays and the degree of satisfaction was surveyed and it was examined if the increase of the degree of satisfaction had an effect on the reduction in the examination time. The patients who utilized the examination information printout revealed results of approximately a 7.8% higher degree of satisfaction among the patients who had previous experience receiving x-ray examinations compared to those were having an x-ray for the first time. In the age groups between 30 to 70 years of age, the age group in the 30's revealed the lowest level of satisfaction at approximately 69% and the group in the 50's showed the highest degree of satisfaction of 87.94%. In the survey of the Radiologic Technologists, 85% responded that they were satisfied. In the question that stated "Will the examination information printouts reduce the time involved in unnecessary conversations with the patients?," the responses showed a 95% degree of satisfaction. The degree of satisfaction was high over the examination information printout by both the patients and the Radiologic Technologists. Although the effects of examination time reduction varied based on the ages of the patients and physical conditions that they were in and could not be given measurement values, it was able to be seen through the survey that reduction of the unnecessary communication between the patient and the Radiologic Technologists contributed to the increase in the degree of satisfaction. As a result, both the patients and the Radiologic Technologists had an increased degree of satisfaction over the examination information printout and it was possible for improvements to be made in the quality of medical service provided as well. Nevertheless, it is considered that a more developed manual in terms of quality and quantity must be produced using a more systematic approach and design.

  • PDF

A Diagnostic Study on the Registered Beneficiaries of Health Centers - From the Perspective of the Precede Model - (보건소 건강관리회원의 진단적 연구 - PRECEDE 모형을 중심으로 -)

  • Yun, Soon-Nyung;Park, Jung-Ho;Park, Sung-Ae;Park, Hyeoun-Ae;Kim, Chun-Mi
    • Research in Community and Public Health Nursing
    • /
    • v.13 no.2
    • /
    • pp.292-305
    • /
    • 2002
  • Purpose: The purpose of this study was to conduct a systematic assessment on the level of health status, and quality of life of the health care beneficiaries registered in health management programs of public health centers. In order to investigate the level of health status and the quality of life and to find factors affecting them, the PRECEDE model, that was developed by Green, et al. for the purpose of a comprehensive diagnostic research, was used. Method: The subjects were 81 residents who resided K-gu, Seoul. Data were collected from September, 1999 to August, 2000 using a self reported questionnaire. The data were analyzed by descriptive statistics, t-test, Kruskall-Wallis test, Pearson's correlation coefficient. and path analysis. Results: 1. The quality of life and the level of health promoting lifestyle were moderate or more, but were not significantly different by sex, age, marital status, educational level. occupation, and monthly household income. 2. Self-efficacy was significantly correlated to be a perceived benefit, social support and health-promoting lifestyle. Perceived benefit had a significant correlation with social support and health promoting lifestyle. There was also a significant correlation between the level of satisfaction, and the availability of the health promotion program. 3. Social support, health promoting lifestyle, and health status were found to influence the quality of life directly, whereas self efficacy and perceived benefit affected the quality of life indirectly through social support. Conclusion: The results of this study suggest that the health promotion program should include strategies to strengthen self efficacy and perceived benefit to enhance social support, and to encourage health promoting behaviors in order to improve the quality of life of the health care beneficiary.

  • PDF

Evaluation of compression ratios using JPEG 2000 on diagnostic images in dentistry (치과병원에서 사용되는 진단영상에 대한 JPEG2000 압축률에 대한 평가)

  • Jung Gi-Hun;Han Won-Jeong;Yoo Dong-Soo;Choi Soon-Chul;Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.35 no.3
    • /
    • pp.157-165
    • /
    • 2005
  • Purpose : To find out the proper compression ratios without degrading image quality and affecting lesion detectability on diagnostic images used in dentistry compressed with JPEG 2000 algorithm. Materials and Methods : Sixty Digora periapical images, sixty panoramic computed radiographic (CR) images, sixty computed tomographic (CT) images, and sixty magnetic resonance (MR) images were compressed into JPEG 2000 with ratios of 10 levels from 5:1 to 50:1. To evaluate the lesion detectability, the images were graded with 5 levels (1 : definitely absent; 2: probably absent; 3: equivocal; 4: probably present; 5: definitely present), and then receiver operating characteristic analysis was performed using the original image as a gold standard. Also to evaluate subjectively the image quality, the images were graded with 5 levels (1 definitely unacceptable; 2: probably unacceptable; 3: equivocal, 4: probably acceptable; 5· definitely acceptable), and then paired t-test was performed. Results : In Digora, CR panoramic and CT images, compressed images up to ratios of 15 : 1 showed nearly the same lesion detectability as original images, and in MR images, compressed images did up to ratios of 25 : 1. In Digora and CR panoramic Images, compressed images up to ratios of 5 : 1 showed little difference between the original and reconstructed images in subjective assessment of image quality In CT images, compressed images did up to ratios of 10: 1 and in MR images up to ratios of 15 : 1 Conclusion : We considered compression ratios up to 5 : 1 in Digora and CR panoramic images, up to 10 : 1 in CT images, up to 15 : 1 in MR images as clinically applicable compression ratios.

  • PDF

A Study on Production and Its Usefulness of AAPM TG18 Guiding Instrument for Diagnostic Monitor QC (영상의학 검사 판독용 모니터 정도관리 Guiding Instrument 제작과 유용성 고찰)

  • Son, Gi-Gyeong;Sung, Dong-Wook;Jeong, Jae-Ho;Kang, Hui-Doo;Ryu, Kyung-Nam
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.21-28
    • /
    • 2008
  • Diagnostic display monitor QA according to AAPM TG18 is usually performed by PACS administrator, product manager and reading doctor, and for acceptance testing and periodic quality control evaluation, a combination of visual and quantitative tests can be used, as outlined in sections 5 and 6 of 'assessment of display performance for medical imaging systems'. Although many display tests can be performed visually, a more objective and quantitative evaluation of display performance requires special test tools. The required instruments vary in their complexity and cost, depending on the context of the evaluation(research, acceptance testing, or quality control) and how thorough the evaluation needs to be. Objective and reliable assessment of many display characteristics can be performed with relatively inexpensive equipment, So, we made 'AAPM TG18 guiding instrument' to ues variable purpose of the evaluation of 'geometrical distortions(quantitative"', 'veiling glare(visual)' and 'sensor calibration'. The spatial measurements for the quantitative evaluation of geometric distortions, and the measurement of the veling-glare ring response function which provides information regarding the spatial extent of the luminance spread, can be performed using the TG18 guiding instrument can be used to sensor calibration to standardize the basic rate of 0% luminance when periodic calibration.

  • PDF