An Experimental Study on the Engineering Properties of the Three Components Middle Fluidity Concrete (3성분계 중유동 콘크리트의 공학적 특성에 관한 실험적 연구)

  • 김갑수;조봉석;윤종기;윤문기;장종호;김무한
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.9-12
    • /
    • 2003
  • High flowing concrete has not spread whole in the normal concrete structure, because it requires special quality control technique. And recently owing to the lack of natural resources and reinforcement of environmental standard, the construction cost of cement is increased rapidly. Also remicon industry has gone through various economical difficulty as the manufacture cost of concrete is increased. So, the purpose of this study is to evaluate the qualities of middle fluidity concrete using the fly-ash and portland blast-furnace slag cement in order to decrease the amount of cement and resolve the problem of the quality control of high flowing concrete and the manufacture cost. The results of this study show that it reduce the amount of addition of superplasticizer and develope properties of concrete to the use the fly-ash and portland blast-furnace slag cement.

  • PDF

An Experimental Study on the Engineering Property of Concrete With Replacement Ratio of Crushed Sand (부순모래 대체율에 따른 콘크리트의 공학적 특성에 관한 실험적 연구)

  • Park Jong Ho;Lee Eui Bae;Choi Se Jin;Lee Seong Yeun;Kim Gyu Yong;Kim Moo Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.451-454
    • /
    • 2005
  • Recently, Trouble of sand supply is occurred according to exhaustion of natural sand resources. therefore, various measures are proposed for solution of trouble of sand supply and crushed sand among measures is used as one of most universal measures. but because crushed sand have poor particle shape and plenty of makes micro particle, the quality of concrete using crushed sand deteriorated. Therefore, this study evaluated engineering property of concrete with replacement ratio of crushed sand and applied evaluation result to fundamental data for quality control of concrete using crushed sand. The result of this study have shown that quality of concrete using crushed sand independently is poor against general concrete. but, the concrete mixing crushed sand with general sand can be similar in workability of concrete used general sand and increase compressive strength of concrete as against concrete using general sand.

  • PDF

A Fundamental Study on the Vafiation of Quality by the Freezing of Admixture Agent for Concrete (콘크리트용 혼화제의 동결에 따른 품질변화에 관한 기초적 연구)

  • 이건철;한경익;이진규;윤기원;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.65-68
    • /
    • 1996
  • As a fundamental study on the quality control according to the freezing of admixture agent for concrete, this study instends to investigate the variation of quality of admixture according to the freezing by analyzing flow, unit weight, and compressive, tensil, flexural strength of cement mortar using admixture agent before and after freezing.

  • PDF

TEMPERATURE CONTROL AND COMPRESSIVE STRENGTH ASSESSMENT OF IN-PLACE CONCRETE STRUCTURES USING THE WIRELESS TEMPERATURE MEASURING SYSTEM BASED ON THE UBIQUITOUS SENSOR NETWORK

  • Ho Kyoo JO;Hyung Rae KIM;Tae Koo KIM
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.794-799
    • /
    • 2009
  • The temperature control of in-place concrete is the most important factor for an early age of curing concrete. Heat stress of mass concrete caused by the heat of hydration can induce the crack of concrete, and a frost damage from cold weather casting concrete results defect on compressive strength and degradation of durability. Therefore, success and failure of concrete work is dependant on the measurement and control of concrete temperature. In addition, the compressive strength assessment of in-place concrete obtained from the maturity calculated from the history of temperature make a reduction of construction cycle time, possible. For that purpose, wireless temperature measuring system was developed to control temperature and assess strength of concrete. And, it was possible to monitor the temperature of concrete over 1km apart from site office and to take a proper measure; mesh-type network was developed for wireless sensor. Furthermore, curing control system that contains the program capable to calculate the maturity of concrete from the history of temperature and to assess the compressive strength of concrete was established. In this study, organization and practical method of developed curing control system are presented; base on in-place application case.

  • PDF

Thermal Crack Control of LNG Tank Roof (LNG 탱크 Roof의 온도균열 제어)

  • 김태홍;하재담;유재상;이종열;권영호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.421-424
    • /
    • 2002
  • Concrete roof in In-Chon LNG tank #15~18 is a very important structure. Precise control of quality is needed. This roof has 0.6~1.5m thickness, 36.23m radius, and, 12.7m height. So in this structure thermal crack caused by hydration heat should be controled. In this project belite cement plus LSP concrete is used. As a result of ambient temperature rising test and thermal analysis using FEM, this belite cement plus LSP concrete is expected to control the thermal crack well.

  • PDF

Quality Inspection for Cast-In-Place Concrete with the Device to Record Curing Temperature (양생온도 이력 기록장치를 이용한 현장타설 콘크리트의 품질검사)

  • Cho, Yeong-Kweon;Kim, Kwan-Ho;Kim, Meyong-Won;Lee, Jun-Gu;Yoo, Jung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.351-354
    • /
    • 2005
  • Quality of concrete required to achieve the desired levels of strength and durability depend on the effectiveness of the curing method. During cold weather, the concrete at the time of placement should be taken to prevent damage to concrete due to freezing. Since the cement-water reaction is exothermic by nature, the temperature within mass concrete can be quite high. The temperature control for massive sections should be taken more careful than for shallow sections. However, in the constructing hydraulic structures, the curing temperature control for concrete had been very difficult to be taken in a proper way because the conditions constructing them are poor and contractors are small enterprises. For several. reasons including above, Rural Research Institute has developed a device and program for recording curing temperature history in cold weather concrete and mass. As there are two major advantages of the device, namely cheapness and availability, this program and device has been recommended to the use of curing temperature control in cold weather concrete and mass.

  • PDF

The Study on Earlier Evaluation of Concrete Strength Using Electric Resistance Method (전기 저항법을 이용한 콘크리트 조기 강도 판정에 관한 연구)

  • 김화중;이도현;윤상천;박정민;최신호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.130-135
    • /
    • 1995
  • We can consider that the study on early evaluation of strength of concrete is useful to raise safety of building and utility of quality control of concrete is useful to raise safety of building and utility of quality control of concrete. In this paper, was proposed to method early to predict strength of concrete with key parameters, such as Water/Cement(W/C) ratio and Sand / Aggregate(S/A) ratio. Through a series of experiment, the obtained results are summarized as follow. $\circled1$ The ratio of resistance was decteased as the increase of W/C ratio. $\circled2$ The maximum value for the ratio of resistance and compressive strength was presented in the case of 40% S/A ratio. $\circled3$ The relationship. of the ratio of resistance and compressive strength on 28days according to the change of W/C and S/A ratio is to be: $F_{28}=-0.00104R^2 + 2.263R - 935.5$ (W/C Ratio) $F_{28} = 0.007R^2 - 10.693R - 4269.1$ (S/A Ratio)

  • PDF

Performance test of Concrete IoT Management System for concrete early-age quality control (콘크리트 초기 품질관리를 위한 CIMS의 개발성능 Test)

  • Lee, Young-Jun;Choi, Yoon-Ho;Seo, Hang-Goo;Hyun, Seung-Yong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.161-162
    • /
    • 2019
  • The aim of the research is analyzing the performance of the concrete IoT management system invented with similar technique from 'G' company to certify the performance of CIMS. As a results, the compressive strength assessing performance was compared. Since both systems assess concrete compressive strength with maturity method based on measured concrete temperature, both systems measured concrete temperature similarly, and maturity was calculated similarly. Therefore, the assumed compressive strength values were similar for both systems. Therefore, through the test, compressive strength assessing performance of CIMS was considered as a similar level of the 'G' company's system. Furthermore, it is considered that the CIMS has an additional advantage of reusability, adding capability of additional sensor, and wider range of Bluetooth communication.

  • PDF