• Title/Summary/Keyword: QM

Search Result 342, Processing Time 0.026 seconds

Noise Modeling and Performance Evaluation in Nanoscale MOSFETs (나노 MOSFETs의 노이즈 모델링 및 성능 평가)

  • Lee, Jonghwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.3
    • /
    • pp.82-87
    • /
    • 2020
  • The comprehensive and physics-based compact noise models for advanced CMOS devices were presented. The models incorporate important physical effects in nanoscale MOSFETs, such as the low frequency correlation effect between the drain and the gate, the trap-related phenomena, and QM (quantum mechanical) effects in the inversion layer. The drain current noise model was improved by including the tunneling assisted-thermally activated process, the realistic trap distribution, the parasitic resistance, and mobility degradation. The expression of correlation coefficient was analytically described, enabling the overall noise performance to be evaluated. With the consideration of QM effects, the comprehensive low frequency noise performance was simulated over the entire bias range.

Piezoelectric and Dielectric Properties of PZW-PMN-PZT Piezoelectric Ceramic according to Sintering Aid Li2CO3 Addition (소결조제 Li2CO3 첨가에 따른 PZW-PMN-PZT 압전 세라믹의 압전 및 유전 특성)

  • Lee, Kab-Soo;Lee, Il-Ha;Yoo, Ju-Hyun;Ryu, Sung-Lim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.12
    • /
    • pp.1034-1038
    • /
    • 2007
  • In order to develop the composition ceramics capable of being sintered at low temperature with high piezoelectric properties for multilayer piezoelectric actuator application, PZW-PMN-PZT system ceramics were manufactured according to sintering aid $Li_2CO_3$ addition and their microstructural, dielectric and piezoelectric properties were investigated. The crystal structure of the specimens showed a perovskite phase and no pyrochlore or other second phase was detected. At the sintering temperature of $900\;^{\circ}C,\;0.2\;wt%Li_2CO_3$ added specimen showed a optimum values of kp = 0.562, $d_{33}\;=\;360\;pC/N$ and Qm = 1184, respectively.

Assessment of Insulation Condition in Operating Large Turbine Generator (운전중인 대형 터빈발전기에서 절연상태 평가)

  • 김희동
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.6
    • /
    • pp.324-329
    • /
    • 2004
  • Six stator slot couplers(SSC) and a flux probe sensor installed on the stator winding slots of large turbine generator. Assessment of insulation condition has been based upon the measurements of partial discharge(PD) of stator windings and shorted-turn of rotor windings in operating large turbine generator. The maximum PD magnitude(Qm), normalized quantify number(NQN), PD pattern and shorted-turn were measured using on-line insulation condition monitoring system. The NQN and Qm of slot PD side in the phase A are indicated the highest value in six SSC sensors. Monitoring system results showed that discharge at conductor surface and internal discharge were detected at the surface of stator winding and in voids of the groundwall insulation. Insulation of stator and rotor windings in large turbine generator was judged to be in good condition.

Electrical Characteristics of the PSN-PMN-PZT Ceramics with Microstructure (PSN-PMN-PZT 세라믹스의 미세구조에 따른 전기적 특성)

  • 민석규;윤광희;류주현;홍재일;이수호;임인호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.234-237
    • /
    • 2000
  • In this paper, the structural, dielectric and piezoelectric properties of the Pb[(S $b_{1}$2/N $b_{1}$2/)$_{0.035}$- $_Mn_{1}$3/N $b_{2}$3/)$_{0.065}$-(Z $r_{0.49}$, $Ti_{0.51}$)$_{0.90}$] $O_3$ ceramics were investigated with respect to the variation of the milling time. Grain size was decreased as the increase of milling time. As the milling time is increased, the particle size of the powder was decreased. Dielectric constant and electromechanical coupling factor (Qm)were slowly increased with the increase of milling time. The highest value of Qm was 1,497 at milling time 8 hour. Temperature coefficient of resonant frequency(TC $F_{r}$) was moved to positive side with the increase of milling time.e.e.e.e.e.e.

  • PDF

Piezoelectric properties of multilayer actuator as a function of the number of multilayer (층수 변화에 따른 적층형 압전액츄에이터의 압전특성)

  • Lee, Kab-Soo;Lee, Il-Ha;Yoo, Ju-Hyun;Jeong, Yeong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.270-271
    • /
    • 2007
  • In this study, piezoelectric properties of PZW-PMN-PZT multilayer actuator sintered at $900^{\circ}C$ low temperature have been investigated. The multilayer actuator was fabricated by tape casting methods. The density above $8[g/cm^3]$ was obtained at all the specimens. Also, according to increasing the number of multilayer, effective electromechanical coupling factor$(k_{eff})$ showed increasing trend. The $k_{eff}$ of multilayer actuator showed the maximum value of 0.283 at 11 layer. However, according to increasing the number of multilayer, mechanical quality factor(Qm') showed decreasing tend. The Qm' of multilayer actuator showed the maximum value of 920 at 5 layer.

  • PDF

A study on the Dielectric and piezoelectric characteristic of PSN-PZT system ceramics (PSNI-PZT계 세라믹스의 유전적, 압전적 특성에 관한 연구)

  • 이용우;류주현;윤광희;정회승;김종선
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.260-264
    • /
    • 1999
  • In this paper, the structural, dielectrial and piezoelectrical properties of 0.03Pb(Sb$\sub$1/2/Ti$\sub$0.495/)O$_3$+Xwt% MnO(x= 0, 0.3, 0.4, 0.5, 0.7) system ceramics were investigated as a function of the addition of MnO. As a result, the samples of 0.3wt% MnO content showed the highest mechanical quality factor(Qm) of 1487, and its dielectric constant and electro mechanical coupling factor(Kp) 1357, 54.3%, respectively. Therefore, the dielectrial and piezoelectrical properties of the composition ceramics were indicated as the materials suitable for piezoelectric transformer.

  • PDF

Low temperature sintering properties of the $Pb(Mg_{1/2}W_{1/2})O_3-Pb(Mn_{1/3}Nb_{2/3})O_3-Pb(Zi,Ti)O_3$ ceramics with the addition of sintering aids (소결조제 첨가에 따른 PMW-PMN-PZT 세라믹의 저온소결 특성)

  • Lee, Hyun-Seok;Yoo, Ju-Hyun;Lee, Chang-Bae;Jeong, Yeong-Ho;Paik, Dong-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.350-351
    • /
    • 2005
  • In this study, in order to develop the low temperature sintering multilayer piezoelectric transformer, PMW-PMN-PZT system ceramics were manufactured with the addition of sintering aids, and their dielectric and piezoelectric characteristics were investigated. At the composition ceramics sintered at $900^{\circ}C$, dielectric constant(${\varepsilon}r$), electromechanical coupling factor(kp) and mechanical quality factor(Qm) showed the optimal value of 1043, 0.44 and 793, respectively, for multilayer piezoelectric transformer application.

  • PDF

Piezoelectric and dielectric properties of PZW-PMN-PZT piezoelectric ceramic according to variation of sintering aids. (소결조제 변화에 따른 PZW-PMN-PZT 압전 세라믹의 압전 및 유전 특성)

  • Lee, Kad-Soo;Lee, Il-Ha;Yoo, Ju-Hyun;Ryu, Sung-Lim
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.290-291
    • /
    • 2007
  • In this study, in order to develop the low temperature sintering multilayer piezoelectric actuator, PZW-PMN-PZT system ceramics were manufactured according to variation of sintering aids. At the sintering temperature of $900^{\circ}C$, $0.3wt%Li_2CO_3$, $0.2wt%Bi_2O_3$ and 0.2wt%CuO added specimen showed a maximum value of kp = 0.552, $d_{33}\;=\;344pC/N$ and Qm = 1320, respectively.

  • PDF

사중극 질량 분석기[QMS]를 이용한 미세 농도의 수소기체 분석

  • Im, Han-Na;Kim, Jin-Tae;Jeong, Su-Hwan;Gang, Sang-U;Yun, Ju-Yeong;Sin, Yong-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.331-331
    • /
    • 2010
  • 반도체 제조, 디스플레이 산업 등의 진공공정에서 잔류기체의 종류와 양에 대한 관심이 높아지면서 사용이 쉽고 높은 정확도를 가지는 사중극 질량 분석기(QMS)가 널리 쓰이고 있다. 특히 고진공으로 내려가면서 리크디텍션(leak detection)과 미세량의 잔류기체 감지가 더욱더 요구된다. 그중에서도 진공공정에서의 수소 가스를 감지하는 것은 매우 중요하므로 $H_2$/Ar 혼합가스를 이용하여 미세농도의 수소를 측정하였다. 측정하려는 가스를 부피확장 방법으로 가스챔버로 희석하여 이동시키고 핀홀에서 가스유량을 더 줄여서 QMS가 기체를 감지하는 압력범위를 유지하면서 측정하였다. 미세량의 수소기체를 감지하기 위해 이온소스의 emission current, Ion ref. voltage, cathode voltage의 변수를 조절하여 QMS를 최적화 하였으며, 그 결과 수십 ppm 농도까지 측정이 가능하다.

  • PDF

Quality Monitoring Comparison of Global Positioning System and BeiDou System Received from Global Navigation Satellite System Receiver

  • Son, Eunseong;Im, Sung-Hyuck
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.7 no.4
    • /
    • pp.285-294
    • /
    • 2018
  • In this study, we implemented the data quality monitoring algorithm which is the previous step for real-time Global Navigation Satellite System (GNSS) correction generation and compared Global Positioning System (GPS) and BeiDou System (BDS). Signal Quality Monitoring (SQM), Data QM, and Measurement QM (MQM) that are well known in Ground Based Augmentation System (GBAS) were used for quality monitoring. SQM and Carrier Acceleration Ramp Step Test (CARST) of MQM result were divided by satellite elevation angle and analyzed. The data which are judged as abnormal are removed and presented as Root Mean Square (RMS), standard deviation, average, maximum, and minimum value.