• Title/Summary/Keyword: QC

Search Result 473, Processing Time 0.024 seconds

A Study of the Stagnant QC Circle Activities (품질관리분임조(品質管理分任組) 활성화(活性化) 방안(方案)에 관한 연구(硏究) -한국(韓國)과 일본(日本)의 활동(活動) 비교를 중심(中心)으로-)

  • Kim, Won-Jung
    • Journal of Korean Society for Quality Management
    • /
    • v.9 no.1
    • /
    • pp.46-50
    • /
    • 1981
  • The aim of this study lies in seeking the desirable countermeasure for the QC Circle Activities in Stagnation, through the componative study of QC Circle Activities in the companies of the two nations Korea and Japan. This study will be treated in the various aspects, for example, the motives of the initation of QC Circle, aim of the activities, themes of QC meeting, meeting time, the extent of support of superior of staff, over times payment, the cause of mactivity, etc. And according to the data and experience, the reasonable way of QC Circle Activities will be suggested.

  • PDF

COMMON FIXED POINT THEOREMS FOR TWO SELF MAPS SATISFYING ξ-WEAKLY EXPANSIVE MAPPINGS IN DISLOCATED METRIC SPACE

  • Kim, Jong Kyu;Kumar, Manoj;Preeti, Preeti;Poonam, Poonam;Lim, Won Hee
    • Nonlinear Functional Analysis and Applications
    • /
    • v.27 no.2
    • /
    • pp.271-287
    • /
    • 2022
  • In this article, we shall prove a common fixed point theorem for two weakly compatible self-maps 𝒫 and 𝔔 on a dislocated metric space (M, d*) satisfying the following ξ-weakly expansive condition: d*(𝒫c, 𝒫d) ≥ d* (𝔔c, 𝔔d) + ξ(∧(𝔔c, 𝔔d)), ∀ c, d ∈ M, where $${\wedge}(Qc,\;Qd)=max\{d^*(Qc,\;Qd),\;d^*(Qc,\;\mathcal{P}c),\;d^*(Qd,\;\mathcal{P}d),\;\frac{d^*(Qc,\;\mathcal{P}c){\cdot}d^*(Qd,\;\mathcal{P}d)}{1+d^*(Qc,\;Qd)},\;\frac{d^*(Qc,\;\mathcal{P}c){\cdot}d^*(Qd,\;\mathcal{P}d)}{1+d^*(\mathcal{P}c,\;\mathcal{P}d)}\}$$. Also, we have proved common fixed point theorems for the above mentioned weakly compatible self-maps along with E.A. property and (CLR) property. An illustrative example is also provided to support our results.

Quality Control of Agro-meteorological Data Measured at Suwon Weather Station of Korea Meteorological Administration (기상청 수원기상대 농업기상 관측요소의 품질관리)

  • Oh, Gyu-Lim;Lee, Seung-Jae;Choi, Byoung-Choel;Kim, Joon;Kim, Kyu-Rang;Choi, Sung-Won;Lee, Byong-Lyol
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.1
    • /
    • pp.25-34
    • /
    • 2015
  • In this research, we applied a procedure of quality control (QC) to the agro-meteorological data measured at the Suwon weather station of Korea Meteorological Administration (KMA). The QC was conducted through six steps based on the KMA Real-time Quality control system for Meteorological Observation Data (RQMOD) and four steps based on the International Soil Moisture Network (ISMN) QC modules. In addition, we set up our own empirical method to remove erroneous data which could not be filtered by the RQMOD and ISMN methods. After all these QC procedures, a well-refined agro-meteorological dataset was complied at both air and soil temperatures. Our research suggests that soil moisture requires more detailed and reliable grounds to remove doubtful data, especially in winter with its abnormal variations. The raw data and the data after QC are now available at the NCAM website (http://ncam.kr/page/req/agri_weather.php).

Quality Control Probes for Spot-Uniformity and Quantitative Analysis of Oligonucleotide Array

  • Jang, Hyun-Jung;Cho, Mong;Kim, Hyung-Hoi;Kim, Cheol-Min;Park, Hee-Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.7
    • /
    • pp.658-665
    • /
    • 2009
  • Quality control QC for spot-uniformity is a critical point in fabricating an oligonucleotide array, and quantification of targets is very important in array analysis. We developed two new types of QC probes as a means of confirming the quality of the uniformity of attached probes and the quantification of targets. We compared the signal intensities and fluorescent images of the QC and target-specific probes of arrays containing only target-specific probes and those containing both QC and target-specific probes. In a comparison of quality control methods, it was found that the arrays containing QC probes could check spot-uniformity or spot defects during all processes of array fabrication, including after spotting, after washing, and after hybridization. In a comparison of quantification results, the array fabricated by the method using QC probes showed linear and regular results because it was possible to normalize variations in spot size and morphology and amount of attached probe. This method could avoid errors originating in probe concentration and spot morphology because it could be normalized by QC probes. There were significant differences in the signal intensities of all mixtures (P<0.05). This result indicates that the method using QC probes is more useful than the ordinary method for quantification of mixed target. In the quantification of mixed targets, this method could determine a range for mixed targets of various amounts. Our results suggest that methods using QC probes for array fabrication are very useful to the quality control of spots in the fabrication processes of quantitative oligonucleotide arrays.

New methods for optical distance indicator and gantry angle quality control tests in medical linear accelerators: image processing by using a 3D phantom

  • Shandiz, Mahdi Heravian;Layen, Ghorban Safaeian;Anvari, Kazem;Khalilzadeh, Mohammadmahdi
    • Radiation Oncology Journal
    • /
    • v.33 no.1
    • /
    • pp.42-49
    • /
    • 2015
  • Purpose: In order to keep the acceptable level of the radiation oncology linear accelerators, it is necessary to apply a reliable quality assurance (QA) program. Materials and Methods: The QA protocols, published by authoritative organizations, such as the American Association of Physicists in Medicine (AAPM), determine the quality control (QC) tests which should be performed on the medical linear accelerators and the threshold levels for each test. The purpose of this study is to increase the accuracy and precision of the selected QC tests in order to increase the quality of treatment and also increase the speed of the tests to convince the crowded centers to start a reliable QA program. A new method has been developed for two of the QC tests; optical distance indicator (ODI) QC test as a daily test and gantry angle QC test as a monthly test. This method uses an image processing approach utilizing the snapshots taken by the CCD camera to measure the source to surface distance (SSD) and gantry angle. Results: The new method of ODI QC test has an accuracy of 99.95% with a standard deviation of 0.061 cm and the new method for gantry angle QC has a precision of $0.43^{\circ}$. The automated proposed method which is used for both ODI and gantry angle QC tests, contains highly accurate and precise results which are objective and the human-caused errors have no effect on the results. Conclusion: The results show that they are in the acceptable range for both of the QC tests, according to AAPM task group 142.

Measurement uncertainty for QC/QA applied to the chemical analysis (화학 분석 결과의 QA/QC를 위한 측정 불확도)

  • Woo, Jin-Chun;Oh, Sang-Hyub;Kim, Byoung-Moon;Bae, Hyun-Kil;Kim, Kwang-Sub;Kim, Young-Doo
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.475-482
    • /
    • 2005
  • The expression of uncertainty applied to the chemical analysis is highly recommended with increasing demands upon the systematic quality assurance and control(QA/QC) with ISO 17025. For the quantification of quality source, 7 major common sources of uncertainty, normally contributing to the quality of the chemical analysis, were selected from QA/QC literatures of chemical analysis. They were classified into repeatability, drift, uncertainty in standards, linearity of calibration, homogeneity, stability of sample, and matrix effect. And, the quantification of the sources by means of measurement uncertainty was proposed as a prerequisite steps for QA/QC. Examples applied to the quantification procedures of modelling, combination and expression of standard uncertainty for the 7 major common sources were presented as a reference guide for QA/QC in chemical analysis.

Pipeline-Aware QC-IRA-LDPC Code and Efficient Decoder Architecture (Pipeline-Aware QC-IRA-LDPC 부호 및 효율적인 복호기 구조)

  • Ajaz, Sabooh;Lee, Hanho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.72-79
    • /
    • 2014
  • This paper presents a method for constructing a pipeline-aware quasi-cyclic irregular repeat accumulate low-density parity-check (PA-QC-IRA-LDPC) codes and efficient rate-1/2 (2016, 1008) PA-QC-IRA-LDPC decoder architecture. A novel pipeline scheduling method is proposed. The proposed methods efficiently reduce the critical path using pipeline without any bit error rate (BER) degradation. The proposed pipeline-aware LDPC decoder provides a significant improvement in terms of throughput, hardware efficiency, and energy efficiency. Synthesis and layout of the proposed architecture is performed using 90-nm CMOS standard cell technology. The proposed architecture shows more than 53% improvement of area efficiency and much better energy efficiency compared to the previously reported architectures.

An Empirical Study on the Activation of QC Circle Activities in terms of TQC (TQC적(的) 분임조활동(分任組活動)의 활성화(活性化) 진단(診斷)에 관한 실증적(實證的) 연구(硏究))

  • Lee, Sun-Yo;Park, Se-Jin
    • Journal of Korean Society for Quality Management
    • /
    • v.12 no.1
    • /
    • pp.2-8
    • /
    • 1984
  • This paper is a study on the activation of Factory Saemaul QC circle activities contributing much to the management of enterprises. One hundred seventy leaders of QC circles were served as subjects. The factors to activate QC circle activity have been obtained in terms of multivariate analysis. It was observed from the result of the diagnosis that the independency, the relationship of the office-organization and the ability of the achievement-expression are the general problems of Korean enterprises.

  • PDF

Studies on Failure Kind Analysis of the Radiologic Medical Equipment in General Hospital (종합병원 진단용방사선장비의 고장유형 분석)

  • Lee, Woo-Cheul;Kim, Jeong-Lae
    • Journal of radiological science and technology
    • /
    • v.22 no.2
    • /
    • pp.33-39
    • /
    • 1999
  • This paper included a data analysis of the unit of medical devices using mainternance recording card that had medical devices of unit failure mode, hospital of failure mode and MTBF. The results of the analysis were as follows : 1. Medical devices of unit failure mode was the highest in QC/PM such A hospital as 33.9%, B hospital 30.9%, C hospital 30.3%, second degree was the Electrical and Electronic failure such A hospital as 23.5%, B hospital 25.3%, C hospital 28%, third degree was mechanical failure such A hospital as 19.5%, B hospital 22.5%, C hospital 25.4%. 2. Hospital of failure mode was the highest in Mobile X-ray device(A hospital 62.5%, B hospital 69.5%, C hospital 37.4%), and was the lowest in Sono devices(A hospital 16.76%, B hospital 8.4%, C hospital 7%). 3. Mean time between failures(MTBT) was the highest in SONO devices and was the lowest in Mobile X-ray devices which have 200 - 400 failure hours. 4. Anverage failure ratio was the highest in Mobile X-ray devices(A hospital 31.3%, B hospital 34.8%, C hospital 18.7%), and was the lowest in Sono(Ultrasound) devices (A hospital 8.4%, B hospital 4.2%, C hospital 3.5%). 5. Failure ratio results of medical devices according to QC/PM part of unit failure mode were as follows ; A hospital was the highest part of QC/PM (50%) in Mamo X-ray device and was the lowest part of QC/PM(26.4%) in Castro X-ray. B hospital was the highest part of QC/PM(56%) in Mobile X-ray device, and the lowest part of QC/PM(12%) in Gastro X-ray. C hospital was the highest part of QC/PM(60%) in R/F X-ray device, and the lowest a part of QC/PM(21%) in Universal X-ray. It was found that the units responsible for most failure decreased by systematic management. We made the preventive maintenance schedule focusing on adjustement of operating and dust removal.

  • PDF

A Study of Iterative QC-BC Method for AMSU-A in the KIAPS Data Assimilation System (KIAPS 자료동화 시스템에서 AMSU-A의 품질검사 및 편향보정 반복기법에 관한 연구)

  • Jeong, Han-Byeol;Chun, Hyoung-Wook;Lee, Sihye
    • Atmosphere
    • /
    • v.29 no.3
    • /
    • pp.241-255
    • /
    • 2019
  • Bias correction (BC) and quality control (QC) are essential steps for the proper use of satellite observations in data assimilation (DA) system. BC should be calculated over quality controlled observation. And also QC should be performed for bias corrected observation. In the Korea Institute of Atmospheric Prediction Systems (KIAPS) Package for Observation Processing (KPOP), we adopted an adaptive BC method that calculates the BC coefficients with background at the analysis time rather than using static BC coefficients. In this study, we have developed an iterative QC-BC method for Advanced Microwave Sounding Unit-A (AMSU-A) to reduce the negative feedback from the interaction between BC and QC. The new iterative QC-BC is evaluated in the KIAPS 3-dimensional variational (3DVAR) DA cycle for January 2016. The iterative QC-BC method for AMSU-A shows globally significant benefits for error reduction of the temperature. The positive impacts for the temperature were predominant at latitudes of $30^{\circ}{\sim}90^{\circ}$ of both hemispheres. Moreover, the background warm bias across the troposphere is decreased. Even though AMSU-A is mainly designed for atmospheric temperature sounding, the improvement of AMSU-A pre-processing module has a positive impact on the wind component over latitudes of $30^{\circ}S$ near upper-troposphere, respectively. Consequently, the 3-day-forecast-accuracy is improved about 1% for temperature and zonal wind in the troposphere.