• Title/Summary/Keyword: QA/QC

Search Result 91, Processing Time 0.024 seconds

A Practical Method to Quantify Very Low Fluxes of Nitrous Oxide from a Rice Paddy (벼논에서 미량 아산화질소 플럭스의 정량을 위한 실용적 방법)

  • Okjung, Ju;Namgoo, Kang;Hoseup, Soh;Jung-Soo, Park
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.24 no.4
    • /
    • pp.285-294
    • /
    • 2022
  • In order to accurately calculate greenhouse gas emissions in the agricultural field, Korea has been developing national-specific emission factors through direct measurement of gas fluxes using the closed-chamber method. In the rice paddy, only national-specific emission factors for methane (CH4) have been developed. It is thus necessary to develop those for nitrous oxide (N2O) affected by the application of nitrogen fertilizer. However, since the concentration of N2O emission from rice cultivation is very low, the QA/QC methods such as method detection and practical quantification limits are important. In this study, N2O emission from a rice paddy was evaluated affected by the amount of nitrogen fertilizer, by taking into account both method detection and practical quantification limits for N2O concentration. The N2O emission from a rice paddy soils affected by the nitrogen fertilizer application was estimated in the following order. The method detection limit (MDL) of N2O concentration was calculated at 95% confidence level based on the pooled standard deviation of concentration data sets using a standard gas with 98 nmol mol-1 N2O 10 times for 3 days. The practical quantification limit (PQL) of the N2O concentration is estimated by multiplying 10 to the pooled standard deviation. For the N2O flux data measured during the rice cultivation period in 2021, the MDL and PQL of N2O concentration were 18 nmol mol-1 and 87 nmol mol-1, respectively. The measured values above the PQL were merely about 12% of the total data. The cumulative N2O emission estimated based on the MDL and PQL was higher than the cumulative emission without nitrogen fertilizer application. This research would contribute to improving the reliability in quantification of the N2O flux data for accurate estimates of greenhouse gas emissions and uncertainties.

A Study on Quality Assurance(QA) Guideline for Diagnostic Monitor (판독용 모니터 정도관리 항목 및 시행기준안 개발 연구)

  • Son, Gi-Gyeong;Sung, Dong-Wook;Jung, Hae-Jo;Jeong, Jae-Ho;Kang, Hee-Doo;Shin, Jin-Ho;Lee, Sun-Geun;Kim, Yong-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.53-65
    • /
    • 2007
  • PACS has been run at the Kyung Hee University Medical Center(KHMC) since 2001, and the installation and operation of PACS have contributed to automation and quantification of KHMC's medical environment During these five years our greatest concern is how to make our own guiding principle of diagnostic monitor QA which is adapted to international standards. In accordance with the terms of 'KHMC QA Guideline', 'AAPM TG18', 'SMPTE RP133', 'DICOM Part14', 'DIN V 6868-57', 'JESRA X-0093', 'JIS Z4752-2-5' and 'KCARE', concern about quality assurance of medical images are on the increase. With the investigation of acceptance testing and quality control of international standards for medical display devices, and data collection and analysis for recommended guideline, it is reported that acceptance testing(quality control), including geometrical distortion, display reflection, luminance response, luminance uniformity, display resolution, display noise, veiling glare and color chromaticity being adequate and effective to domestic hospital environments for medical display devices and assessment methods according to each performance. Accordingly, KHMC classified the checkpoint items by period, at the time of monitor setting, monthly, quarterly, half-yearly and annually. Periodic classification of checkpoint items for monitor QA makes a good guideline for image QA/QC and useful guideline for persistent good quality of monitor.

  • PDF

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

QA/QC for PAMS Station and VOC Concentration Trends (광화학평가측정망 정도관리 현황과 VOC 농도 특성)

  • 한진석;홍유덕;김상균;김철희;김웅선;이창호;이석조
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.125-125
    • /
    • 2003
  • 우리나라 대기질은 자동차의 급격한 증가와 산업활동이 활달해짐에 따라 VOC, NOx 의 배출량이 급격히 늘어나고 있으며 이에따라 광화학 오존등 2차오염물질에 대한 대기오염문제가 심각해지고 있다. 오존에 의한 대기오염문제를 해결하기 위하여 환경부에서는 2002년부터 서울의 정동, 불광동 둥 수도권 8개 지점에서 광화학평가측정망을 운영하고 있으며, 본 연구에서는 이들 광화학평가측정망의 정도관리현황을 검토하고 측정지점별 오존전구물질(VOCs) 농도분포 특성을 분석하였다. (중략)

  • PDF

Study on Improvement in Reliability of Analysis for VOCs and Aldehydes (대기 중 휘발성유기화합물질 및 알데하이드의 분석 신뢰도 향상에 관한 고찰)

  • Lee M.D.;Lee S.U.;Lim Y.J.;Kim Y.M.;Kim S.Y.;Moon K.J.;Han J.S.;Chung I.R.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.4
    • /
    • pp.468-476
    • /
    • 2006
  • Hazardous air pollutants (HAPs) have high toxicity and bioaccurnulation potentials into human body even inbsmall amount (levels of ng/$m^3$). As the levels of HAPs might be controversial, it has been become essential to establish the analysis method for correct results. In this study, various analysis methods of VOCs and Aldehydes were compared in order to select the proper methods in our condition. Sampling and analysis method of VOCs were followed to EPA TO-14a and TO-17. VOCs were collected in absorption tube and separated by thermal desorption unit then analyzed by GC/MSD. Aldehydes were sampled in DNPH-cartridge and extracted into solution then analyzed by HPLC as the same condition of EPA TO-13a. This study also shows the results of QA/QC system of selected methods. Some experiments could be improving the data assurance blank test, calibration check, repetition precision check, the determination of detection limit and reproducibility of the retention time. Precisions of VOCs and aldehydes were ranged in 2$\sim$9% and 1$\sim$4% RSD, respectively. Recovery rate of VOCs showed variable ranges from 60 to 133.5%. MDL of VOCs and aldehydes were 0.044$\sim$0.284 ppb and 0.14$\sim$1.02 ng, respectively.

Some Insights into the Basic QA/QC for the Greenhouse Gas Analysis: Methane and Carbon Dioxide (온실가스 기기분석의 정도관리를 위한 고려사항 연구 - CH4과 CO2를 중심으로 -)

  • Jeong, Jae-Hak;Lim, Ho-Soo;Kim, Ki-Hyun;Bae, Wi-Sup;Jeon, Eui-Chan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.5
    • /
    • pp.712-718
    • /
    • 2006
  • In order to investigate the analytical uncertainties associated with sampling and analysis of major greenhouse gaseous pollutants(carbon dioxide and methane), we attempted to quantify their adsorptive loss due to the contact with the container wall(such as Tedlar bag and vial). Using the GC/FID method, some basic experimental parameters(such as reproducibility and method detection limit) have been evaluated as part of the essential QA/QC The reproducibilities of carbon dioxide and methane were estimated as 2.02 and 0.2%, respectively. In addition, method detection limits were measured as 0.61 and 0.06 ng, respectively. A test of sample loss rate has also been made for Tedlar bag and vial by assessing the absolute amount of sample loss on the wall. By transferring the samples contained in Tedlar bag to various sizes of Tedlar bags, we measured differences in the absolute loss quantity due to such transfer. In addition, we also examined such loss mechanism as a function of elapsed time and light penetration rate for vial. As results, carbon dioxide and methane have shown about 2% of sample loss due to such contact. It is also noticed that the amount of loss with vial surface is lower than that of Tedlar bag. Therefore, field collection of greenhouse gases using various container types should be made more cautiously to minimize the possibility of sample loss and bias related to such loss.

Preparation of a CRM for QA/QC in dioxin analysis and inter-laboratory study (다이옥신 정도 관리용 CRM 제조와 실험실간 비교평가)

  • Yu, Byeong-Woon;Moon, Young-Hoon;Kim, Min-Kwan;Kyoung, Jong-Dai;Chang, Yoon-Seok
    • Analytical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.153-162
    • /
    • 2004
  • Dioxin CRM for QA/QC was prepared with fly ash collected from municipal waste incinerator. With that CRM inter-laboratory test was carried out. The collected fly ash was conducted several homogeneity steps including sievings and mixing. Homogeneity test and estimation of uncertainty was performed by one-way ANOVA based on ISO guide 35. Compared concentrations of fly ash of participants to CRM values, PCDDs value was lower than that of CRM in almost participants, and showed higher PCDFs concentration than that of CRM. Although there is a small difference in PCDD/Fs concentrations with congeners of extract, the result was close to mean value.

A CT Simulator Phantom for Geometrica1 Test (CT 시뮬레이터의 기하학적 성능평가용 팬톰)

  • Min, Chul-Kee;Yi, Byong-Yong;Ahn, Seung-Do;Choi, Eun-Kyung;Chang, Hye-Sook
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.337-344
    • /
    • 2000
  • Purpose :To design and test test CT simulator phantom for geometrical test. Materials and Methods : The PMMA phantom was designed as a cylinder which is 20 cm in diameter and 24 cm in length, along with a 25$\times25\times31cm^{3}$ rectangular parallelepiped. Radio-opaque wires of which diameter is 0.8 mm are attached on the other surface of the phantom as a spiral. The rectangular phantom was made of four 24$\times24\times0.5 cm^{3}$ square plates and each plate had a 24$\times24 cm^{2}$, 12$\times12cm^{2}$, 6$\times6 cm$^{2}$ square line. The squares were placed to face the cylinder at angles 0 $^{\circ}$ , 15 $^{\circ}$ , 30 $^{\circ}$ ,respectively. The rectangular phantom made it possible to measure the field size, couch angle, the collimator angle, the isocenter shift and the SSD, the measurements of the gantry angle from the cylindrical part. A virtual simulation software, AcOSim, offered various conditions to perform virtual simulations and these results were used to perform the geometrical Quality assurance of CT simulator. Results : A 0.3$\~$0.5 mm difference was found on the 24 cm field size which was created with the DRR measurements obtained by scanning of the rectangular phantom. The isocenter shift, the collimator rotation, the couch rotation, and the gantry rotation test showed 0.5$\~$1 mm, 0.5$\~$l$^{\circ}$ 0.5$\~$ 1$^{\circ}$ , and 0.5-1 $^{\circ}$ differences, respectively. We could not find any significant differences between the results from the two scanning methods. Conclusion :The geometrical test phantom developed in the study showed less than 1 mm (or 1 $^{\circ}$ ) differences. The phantom could be used as a routine geometrical QC/QA tools, since the differences are within clinically acceptable ranges.

  • PDF

Functions of the Plant Qbc SNARE SNAP25 in Cytokinesis and Biotic and Abiotic Stress Responses

  • Won, Kang-Hee;Kim, Hyeran
    • Molecules and Cells
    • /
    • v.43 no.4
    • /
    • pp.313-322
    • /
    • 2020
  • Eukaryotes transport biomolecules between intracellular organelles and between cells and the environment via vesicle trafficking. Soluble N-ethylmaleimide-sensitive factor attachment protein receptors (SNARE proteins) play pivotal roles in vesicle and membrane trafficking. These proteins are categorized as Qa, Qb, Qc, and R SNAREs and form a complex that induces vesicle fusion for targeting of vesicle cargos. As the core components of the SNARE complex, the SNAP25 Qbc SNAREs perform various functions related to cellular homeostasis. The Arabidopsis thaliana SNAP25 homolog AtSNAP33 interacts with Qa and R SNAREs and plays a key role in cytokinesis and in triggering innate immune responses. However, other Arabidopsis SNAP25 homologs, such as AtSNAP29 and AtSNAP30, are not well studied; this includes their localization, interactions, structures, and functions. Here, we discuss three biological functions of plant SNAP25 orthologs in the context of AtSNAP33 and highlight recent findings on SNAP25 orthologs in various plants. We propose future directions for determining the roles of the less well-characterized AtSNAP29 and AtSNAP30 proteins.

Survey Study on Basic Procedures for Establishment of National Greenhouse Gas Inventory (IPCC Guidelines) (국가온실가스 인벤토리 구축 기본절차(IPCC 지침)에 대한 조사 연구)

  • Paik, Chun-Hyun;Yoo, Jong-Hun;Kim, Ho-Gyun
    • IE interfaces
    • /
    • v.22 no.4
    • /
    • pp.317-328
    • /
    • 2009
  • For a comprehensive understanding of human impact on a change of the global climate, it is necessary to obtain reliable information on man-induced fluxes of greenhouse gases (GHGs) into the atmosphere. Intergovernmental Panel on Climate Change (IPCC) guidelines (IPCC 1996, IPCC 2000, IPCC2006) provide the methods and procedures of estimating the national GHG emission inventories. Particularly, IPCC 2006 contains new chapter of key conceptions uncertainties, including the types of uncertainties and assessment methods of uncertainties in GHG emission inventories. In this paper, a compact and clear survey on volume 1 of IPCC 2006, which contains the general information on inventory compilation, uncertainty and guidance on the choice of methods, and QC/QA, is given with emphasis on uncertainty analysis.