• Title/Summary/Keyword: Q 인자

Search Result 250, Processing Time 0.036 seconds

Effects of Water Temperature and Photoperiod on the Oxygen Consumption Rate of Juvenile Dark-banded Rockfish, Sebastes inermis (수온과 광주기에 따른 볼락, Sebastes inermis 치어의 산소 소비율)

  • Oh Sung-Yong;Noh Choong-Hwan
    • Journal of Aquaculture
    • /
    • v.19 no.3
    • /
    • pp.210-215
    • /
    • 2006
  • An experiment was conducted to investigate the effects of four water temperatures (10, 15, 20, and $25^{\circ}C$) in combination with three photoperiods (24L:0D, 12L: 12D, and OL:24D) on the oxygen consumption rate of juvenile dark-banded rockfish, Sebastes inermis (mean body weight $20.5{\pm}0.7g$). The oxygen consumption rates of S. inermis were measured in triplicate for 24 hours using a continuous flow-through respirometer. Different combinations of water temperatures and photoperiods resulted in significant differences in the mean oxygen consumption rate of S. inermis (P<0.001). The oxygen consumption increased with increasing water temperatures for all photoperiod treatments (P<0.01). Mean oxygen consumption rates at 10, 15,20 and $25^{\circ}C$ ranged $178.3\sim283.5,\;386.7\sim530.7,\;529.2\sim754.3$ and $590.0\sim785.5mg\;O_2kg^{-1}h^{-1}$, respectively. $Q_{10}$ values ranged $3.17\sim5.51$ between 10 and $15^{\circ}C,\;1.87\sim2.10$ between 15 and $20^{\circ}C$ and $1.08\siml.24$ between 20 and $25^{\circ}C$, respectively. Fish held in continuous darkness (OL:24D) used consistently less okygen than fish exposed to continuous light (P<0.05). The mean oxygen consumption offish in a 12L:12D photoperiod was higher than that offish in 24L:0D and 0L:24D photoperiods under all temperature treatments except $10^{\circ}C$. The oxygen consumption of fish exposed to the 12L:12D photoperiod was significantly higher during the light phase than during the dark phase under all temperature treatments except $10^{\circ}C\;(P<0.05)$. This study provides empirical data for estimating oxygen consumption of S. inermis under given condition. This result has application for culture management and bioenergetic model for growth of this species.

Onion Beverages Improve Amyloid β Peptide-Induced Cognitive Defects via Up-Regulation of Cholinergic Activity and Neuroprotection (양파(Allium cepa L.) 음료의 콜린성 활성 증가 및 뇌신경세포 보호로 인한 Amyloid β Peptide 유도에 대한 인지장애 개선 효과)

  • Park, Seon Kyeong;Kim, Jong Min;Kang, Jin Yong;Ha, Jeong Su;Lee, Du Sang;Kim, Ah-Na;Choi, Sung-Gil;Lee, Uk;Heo, Ho Jin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.11
    • /
    • pp.1552-1563
    • /
    • 2016
  • To examine the cognitive function of onion (Allium cepa L.) beverages (odourless and fortified), we analyzed in vitro neuronal cell protection against $H_2O_2$-induced cytotoxicity and performed in vivo tests on amyloid beta ($A{\beta}$)-induced cognitive dysfunction. Cellular oxidative stress and cell viability were evaluated by DCF-DA assay and MTT assay. These results show that fortified beverage resulted in better neuronal cell protection than odourless beverage at lower concentration ($0{\sim}100{\mu}g/mL$). Fortified beverage also showed more excellent acetylcholinesterase (AChE) inhibitory activity ($IC_{50}$: 4.20 mg/mL) than odourless beverage. The cognitive functions of odourless beverage and fortified beverage in $A{\beta}$-induced neurotoxicity were assessed by Y-maze, passive avoidance, and Morris water maze tests. The results show improved cognitive function in both groups treated with beverages. After in vivo tests, cholinergic activities were determined based on AChE inhibition and acetylcholine levels, and antioxidant activities were measured as SOD, oxidized glutathione (GSH)/total GSH ratio, and MDA levels in mouse brain tissue. In a Q-TOF UPLC/MS system, main compounds were analyzed as follows: odourless beverage (five types of sugars and three types of phenolics) and fortified beverages (six types of phenolics and two types of steroidal saponins).

Operator exposure risk assessment of benzimidazole fungicides on Korean agricultural condition (Benzimidazole계 살균제의 농작업자 위해성평가)

  • Lee, Je-Bong;Shin, Jin-Sup;Jeong, Mi-Hye;Park, Yeon-Ki;Im, Geon-Jae;Kang, Kyu-Young
    • The Korean Journal of Pesticide Science
    • /
    • v.9 no.4
    • /
    • pp.347-353
    • /
    • 2005
  • Pesticide risk assessment for pesticide operators as well as for consumers has become one of the pesticide regulatory tools to reduce any unreasonable adverse health effects from pesticide use. The risk for pesticide operators can be quantified by comparing the acceptable operator exposure level(AOEL) with exposure level during pesticide application. This study is to evaluate the risk of benzimidazole fungicides application worker. The exposure level of pesticide applicators were calculated using Japanese operator exposure study tested with EPN 45% EC. The AOELs for pesticides were obtained dividing relevant lowest no observed abuse effect levels(NOAELs) for the exposure scenario into uncertainty factor, 100. For the non-cancer and cancer occupational risk assessment, $Q_1^*$ produced by US/EPA and life time average daily dose(LADD) calculated from average daily dose(ADD), treatment days per year, worked years for life time were used. Operator exposure for benzimidazole fungicides application were benomyl 0.2, carbendazim 0.36 and thiophanate-methyl 0.42 mg/kg/day. Short-term AOELs for benomyl, carbendazim and thiophanate-methyl were 0.3, 0.1, and 0.2 mg/kg/day, and long-term AOEL were 0.025, 0.025, 0.08 mg/kg/day, respectively. LADDs were benomyl 0.0038, carbendazim 0.0067, thiophanate-methyl 0.0081 mg/kg/day. The ratios of exposure to AOEL were $0.28{\sim}1.5$ for short-term and $3.73{\sim}9.88$ for long-term. Cancer risk for operator were $9.12{\times}10^{-6}$ for benomyl, $1.61{\times}10^{-5}$ for carbendazim and $1.13{\times}10^{-4}$ for thiophanate-methyl by the standard application scenario. The result showed 3 fungicides exceed the risk criteria, $1.0{\times}10^{-6}$. The above risk assessments were based upon conservative assumptions and therefore are believed to be protective of the applicator. To refine the risk at the more actual conditions, further risk assessment with more realistic data would be needed.

Analysis of extreme cases of climate change impact on watershed hydrology and flow duration in Geum river basin using SWAT and STARDEX (SWAT과 STARDEX를 이용한 극한 기후변화 사상에 따른 금강유역의 수문 및 유황분석)

  • Kim, Yong Won;Lee, Ji Wan;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.10
    • /
    • pp.905-916
    • /
    • 2018
  • The purpose of this study is to evaluate the climate change impact on watershed hydrology and flow duration in Geum River basin ($9,645.5km^2$) especially by extreme scenarios. The rainfall related extreme index, STARDEX (STAtistical and Regional dynamical Downscaling of EXtremes) was adopted to select the future extreme scenario from the 10 GCMs with RCP 8.5 scenarios by four projection periods (Historical: 1975~2005, 2020s: 2011~2040, 2050s: 2041~2070, 2080s: 2071~2100). As a result, the 5 scenarios of wet (CESM1-BGC and HadGEM2-ES), normal (MPI-ESM-MR), and dry (INM-CM4 and FGOALS-s2) were selected and applied to SWAT (Soil and Water Assessment Tool) hydrological model. The wet scenarios showed big differences comparing with the normal scenario in 2080s period. The 2080s evapotranspiration (ET) of wet scenarios varied from -3.2 to +3.1 mm, the 2080s total runoff (TR) varied from +5.5 to +128.4 mm. The dry scenarios showed big differences comparing with the normal scenario in 2020s period. The 2020s ET for dry scenarios varied from -16.8 to -13.3 mm and the TR varied from -264.0 to -132.3 mm respectively. For the flow duration change, the CFR (coefficient of flow regime, Q10/Q355) was altered from +4.2 to +10.5 for 2080s wet scenarios and from +1.7 to +2.6 for 2020s dry scenarios. As a result of the flow duration analysis according to the change of the hydrological factors of the Geum River basin applying the extreme climate change scenario, INM-CM4 showed suitable scenario to show extreme dry condition and FGOALS-s2 showed suitable scenario for the analysis of the drought condition with large flow duration variability. HadGEM2-ES was evaluated as a scenario that can be used for maximum flow analysis because the flow duration variability was small and CESM1-BGC was evaluated as a scenario that can be applied to the case of extreme flood analysis with large flow duration variability.

Dynamic Changes of Urban Spatial Structure in Seoul: Focusing on a Relative Office Price Gradient (오피스 가격경사계수를 이용한 서울시 도시공간구조 변화 분석)

  • Ryu, Kang Min;Song, Ki Wook
    • Land and Housing Review
    • /
    • v.12 no.3
    • /
    • pp.11-26
    • /
    • 2021
  • With the increasing demand for office space, there have been questions on how office rent distribution produces a change in the urban spatial structure in Seoul. The purpose of this paper is to investigate a relative price gradient and to present a time-series model that can quantitatively explain the dynamic changes in the urban spatial structure. The analysis was dealt with office rent above 3,306 m2 for the past 10 years from 1Q 2010 to 4Q 2019 within Seoul. A modified repeat sales model was employed. The main findings are briefly summarized as follows. First, according to the estimates of the office price gradient in the three major urban centers of Seoul, the CBD remained at a certain level with little change, while those in the GBD and the YBD continued to increase. This result reveals that the urban form of Seoul has shifted from monocentric to polycentric. This shows that the spatial distribution of companies has gradually accelerated decentralized concentration implying that the business networks have become significant. Second, contrary to small and medium-sized office buildings that have undertaken no change in the gradient, large office buildings have seen an increase in the gradient. The relative price gradients in small and medium-sized buildings were inversely proportional among the CBD, the GBD, and the YBD, implying their heterogeneous submarkets by office rent movements. Presumably, those differences in the submarkets were attributed to investment attraction, industrial competition, and the credit and preference of tenants. The findings are consistent with the hierarchical system identified in the Seoul 2030 Plan as well as the literature about Seoul's urban form. This research claims that the proposed method, based on the modified repeat sales model, is useful in understanding temporal dynamic changes. Moreover, the findings can provide implications for urban growth strategies under rapidly changing market conditions.

Lipoprotein and Lipid Abnormalities in Uremic Children with Maintenance Dialysis (투석 치료중인 만성 신부전 소아에서의 지질 및 지질단백 이상)

  • Kim Jung-Sue;Song Jung-Han;Park Hye-Won;Cheong Hae-Il;Kim Jin-Q;Choi Yong;Ko Kwang-Wook
    • Childhood Kidney Diseases
    • /
    • v.1 no.2
    • /
    • pp.109-116
    • /
    • 1997
  • Purpose : Chronic renal failure is often accompanied by severe dyslipidemia, a known risk factor for cardiovascular disease. Lipoprotein(a) [Lp(a)] has recently been characterized as a risk factor for atherosclerosis and thrombosis. Cardiovascular disease is the leading cause of death in adult patients on dialysis. However, there are only limited data available concerning risk factors for atherosclerosis in uremic children. We have measured serum levels of lipids, lipoproteins, apolipoproteins and Lp(a) in uremic children with maintenance dialysis. Methods : Ten uremic children with hemodialysis (HD) and 14 with peritoneal dialysis (PD) in our dialysis unit were included in this study. The mean age of HD patients was $162{\pm}59$ months and the male to female ratio was 7:3. The mean age and sex ratio of PD patients were $123{\pm}63$ months and 6:8, respectively. The levels of cholesterol, triglyceride, lipoproteins, apolipoproteins and Lp(a) were measured from serum sampled after 14 hours of fasting. The normal control levels were cited from 2 articles presenting the normal blood lipid and lipoprotein levels of primary school and middle school children in Korea. Results : There was no difference in age, sex ratio, body mass index and duration of dialysis between the HD and the PD group. The serum concentration of the cholesterol, triglyceride and apolipoprotein B were significantly elevated in dialysis patients compared with normal subjects. The serum level of Lp(a) was significantly elevated in only PD group. The serum Lp(a) level was below 30 mg/dl in 13 and above 30 mg/dl in 11 patients. The serum albumin level was significantly decreased in high Lp(a) group than in low Lp(a) group. Conclusion : The uremic children receiving dialysis reveal abnormal serum lipid and lipoprotein profiles. These results suggest that they have a higher risk for coronary heart disease, although there has been no clinical evidence of coronary heart disease at present. A long-term follow-up study of these children to clarify the suggestion should be started now.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

Mid-Term Results of 292 cases of Coronary Artery Bypass Grafting (관상동맥 우회술 292례의 중기 성적)

  • 김태윤;김응중;이원용;지현근;신윤철;김건일
    • Journal of Chest Surgery
    • /
    • v.35 no.9
    • /
    • pp.643-652
    • /
    • 2002
  • As the prevalence of coronay artery disease is increasing, the surgical treatment has been universalized and operative outcome has been improved. We analyzed the short and mid-term results of 292 CABGs performed in Kangdong Sacred Heart Hospital. Material and Method: From June 1994 to December 2001, 292 patients underwent coronary artery bypass grafting. There were 173 men and 119 women and their ages ranged from 39 to 84 years with a mean of $61.8{\pm}9.1$ years. We analyzed the preoperative risk factors, operative procedures and operative outcome. In addition, we analyzed the recurrence of symptoms, long-term mortality and complications via out-patient follow-up for discharged patients. Result: Preoperative clinical diagnoses were unstable angina in 137(46.9%), stable angina in 34(11.6%), acute myocardial infarction in 40(13.7%), non-Q myocardial infarction in 25(8.6%), postinfarction angina in 22(7.5%), cardiogenic shock in 30(10.3%) and PTCA failure in 4(1.4%) patients. Preoperative angiographic diagnoses were three-vessel disease in 157(53.8%), two-vessel disease in 35 (12.0%), one-vessel disease in 11(3.8%) and left main disease in 89(30.5%) patients. We used saphenous veins in 630, internal thoracic arteries in 257, radial arteries in 50, and right gastoepiploic arteries in 2 distal anastomoses. The mean number of distal anastomoses per patient was $3.2{\pm}1.0$ There were 18 concomitant procedures ; valve replacement in 8(2.7%), left main coronary artery angioplasty in 6(2.1%), patch closure of postinfarction ventricular septal defect(PMI-VSD) in 2(0.7%), replacement of ascending aorta in 1(0.3%) and coronary endarterectomy in 1(0.3%) patient. The mean ACC time was $96.6{\pm}35.3 $ minutes and the mean CPB time was $179.2{\pm}94.6$ minutes. Total early mortality was 8.6%, but it was 3.1% in elective operations. The most common cause of early mortality was low cardiac output syndrome in 6(2.1%) patients. The stastistically significant risk factors for early mortality were hypertension, old age($\geq$ 70 years), poor LV function(EF<40%), congestive heart failure, preoperative intraaortic balloon pump, emergency operation and chronic renal failure. The most common complication was arrhythmia in 52(17.8%) patients. The mean follow-up period was $39.0{\pm}27.0$ months. Most patients were free of symptoms during follow-up. Fourteen patients(5.8 %) had recurrent symptoms and 7 patients(2.9%) died during follow-up period. Follow-up coronary angiography was performed in 13 patients with recurrent symptoms and they were managed by surgical and medical treatment according to the coronary angiographic result. Conclusion: The operative and late results of CABG in our hospital, was acceptable. However, There should be more refinement in operative technique and postoperative management to improve the results.

Quantitative Expression Analysis of Functional Genes in Four Dog Breeds (개의 네 품종에서 기능 유전자들에 대한 정량적 발현 분석)

  • Gim, Jeong-An;Kim, Sang-Hoon;Lee, Hee-Eun;Jeong, Hoim;Nam, Gyu-Hwi;Kim, Min Kyu;Huh, Jae-Won;Choi, Bong-Hwan;Kim, Heui-Soo
    • Journal of Life Science
    • /
    • v.25 no.8
    • /
    • pp.861-869
    • /
    • 2015
  • One of the domesticated species; the dog has been selectively bred for various aims by human. The dog has many breeds, which are artificially selected for specific behaviors and morphologies. Dogs contribute their life to human as working dogs for guide, rescue, detection or etc. Working dogs requires good personality, such as gentleness, robustness and patience for performing their special duty. Many studies have concentrated on finding genetic marker for selecting the high-quality working dog. In this study, we confirmed quantitative expression patterns of eight genes (ABAT; 4-Aminobutyrate Aminotransferase, PLCB1; Phospholipase C, Beta 1, SLC10A4; Solute Carrier Family 10, Member 4, WNT1; Wingless-Type MMTV Integration Site Family, Member 1, BARX2; BarH-Like Homeobox 2, NEUROD6; Neuronal Differentiation 6, SEPT9; Septin 9 and TBR1; T-Box, Brain, 1) among brains tissues from four dog breeds (Beagle, Sapsaree, Shepherd and Jindo), because these genes were expressed and have functions in brain mostly. Specially, BARX2, SEPT9, SLC10A4, TBR1 and WNT1 genes were highly expressed in Beagle and Jindo, and Sapsaree and German Shepherd were vice versa. The biological significance of total genes was estimated by database for annotation, visualization and integrated discovery (DAVID) to determine a different gene ontology (GO) class. In these analyses, we suppose to these eight genes could provide influential information for brain development, and intelligence of organisms. Taken together, these results could provide clues to discover biomarker related to functional traits in brain, and beneficial for selecting superior working dogs.

Anti-inflammatory Activity of Antimicrobial Peptide Zophobacin 1 Derived from the Zophobas atratus (아메리카왕거저리 유래 항균 펩타이드 조포바신 1의 항염증활성)

  • Shin, Yong Pyo;Lee, Joon Ha;Kim, In-Woo;Seo, Minchul;Kim, Mi-Ae;Lee, Hwa Jeong;Baek, Minhee;Kim, Seong Hyun;Hwang, Jae Sam
    • Journal of Life Science
    • /
    • v.30 no.9
    • /
    • pp.804-812
    • /
    • 2020
  • The giant mealworm beetle, Zophobas atratus (Coleoptera: Tenebrionidae) has been used as a protein source for small pets and mammals. Recently, it was temporarily registered in the list of the Food Code. We previously performed an in silico analysis of the Zophobas atratus transcriptome to identify putative antimicrobial peptides and identified several antimicrobial peptide candidates. Among them, we assessed the antimicrobial and anti-inflammatory activities of zophobacin 1 that was selected bio-informatically based on its physicochemical properties against microorganisms and mouse macrophage Raw264.7 cells. Zophobacin 1 showed antimicrobial activities against microorganisms without inducing hemolysis and decreased the nitric oxide production of the lipopolysaccharide-induced Raw264.7 cells. Moreover, ELISA and Western blot analysis revealed that zophobacin 1 reduced expression levels of pro-inflammatory enzymes such as inducible nitric oxide synthase (iNOS) and cyclooxygenase-2 (COX-2). We also investigated expression of pro-inflammatory cytokines (interleukin-6 and interleukin-1β) production through quantitative real time-PCR and ELISA. Zophobacin 1 markedly reduced the expression level of cytokines through the regulation of mitogen-activated protein kinases (MAPKs) and nuclear factor kappa B (NF-κB) signaling. We confirmed that zophobacin 1 bound to bacterial cell membranes via a specific interaction with lipopolysaccharides. These data suggest that zophobacin 1 could be promising molecules for development as antimicrobial and anti-inflammatory therapeutic agents.