• Title/Summary/Keyword: Putty

Search Result 65, Processing Time 0.026 seconds

Guided Bone Regeneration Using a Putty-type Demineralized Bone Matrix: Case Report (Putty형 탈회동종골을 이용한 골유도 재생술: 증례보고)

  • Jang, Han-Seung;Kim, Su-Gwan;Moon, Seong-Yong;Oh, Ji-Su;Park, Jin-Ju;Jeong, Mi-Ae;Yang, Seok-Jin;Jung, Jong-Won;Kim, Jeong-Sun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.5
    • /
    • pp.420-424
    • /
    • 2011
  • Allomatrix (Wright Medical Tech, Inc., Arlington, Tenn, USA), is a newly designed, injectable putty with a reliable demineralized bone matrix (DBM), derived from human bone. The compound contains 86% DBM and other bone growth factors such as bone morphogenic protein (BMP)-2, BMP-4, insulin-like growth factor (IGF)-1, and transforming growth factor (TGF)-${\beta}1$. It has excellent osteoinduction abilities. In addition, DBM is known to have osteoconduction capacity as a scaffold due to its collagen matrix. This product contains a powder, which is a mix of DBM and surgical grade calcium sulfate as a carrier. A practitioner can blend the powder with calcium sulfate solution, making a putty-type material which has the advantages of ease of handling, better fixation, and no need for a membrane, because it can function as membrane itself. This study reports the clinical and radiographic results of various guided bone regeneration cases using Allomatrix, demonstrating its strong potential as a graft material.

Characteristic Analysis of Paint used in Defense Industries Equipments of Korean Conflict in The War Memorial of Korea (전쟁기념관 소장 6·25전쟁 방산장비의 도료 특성 분석)

  • Kang, Hyun Sam;Kim, Soo Chul;Park, Min Soo
    • Journal of Conservation Science
    • /
    • v.32 no.2
    • /
    • pp.215-221
    • /
    • 2016
  • This study conducted analysis of paint samples from defense industries equipments of Korean Conflict in The War Memorial of Korea to identify the characteristics of the modern paint. The samples were analyzed by microscopic observation, infrared spectroscopy and SEM-EDS. Cross-section of paint samples are made up of several layers of about 9 to 20 times, and thickness of the layer is not uniform in the $10{\sim}100{\mu}m$. The putty was used for the surface treatment before painting. Inorganic analysis showed that one type of the putty consist of minium and kaolin, talc, titanium dioxide. According to the results of infrared spectroscopy, paint samples were identified as alkyd resin. Some bands such as C-H bending, C-O and C-C stretching, C-H rocking were found in spectra.

Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

  • Pastoret, Marie-Helene;Krastl, Gabriel;Buhler, Julia;Weiger, Roland;Zitzmann, Nicola Ursula
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.287-293
    • /
    • 2017
  • PURPOSE. To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS. A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (${\pm}SD$). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS. Dimensional changes compared to reference values varied between -74.01 and $32.57{\mu}m$ (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION. The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth.

A Study on the Ratio between Epoxy putty and Original Sculpey for the Ceramic Restoration -As Focus on the White Porcelain of the Joseon Dynasty Period- (도자기 복원을 위한 소성점토와 에폭시퍼티 혼합비 연구 - 조선백자를 중심으로 -)

  • Kim, Heejin;Koh, Minjeong;Lim, Sookyung;Lee, Taejin;Hwang, Hyunsung
    • Conservation Science in Museum
    • /
    • v.14
    • /
    • pp.29-35
    • /
    • 2013
  • In cases, such as white porcelain with openwork lotus scroll design, where the ceramics has intricate form and decorations, we normally use casts to restore the work, in that current restoration materials have short molding time which causes difficulties in delicate work. However, since using a cast for restoration requires longer work-time and uses more materials, we decided to restore in direct. Since the molding time in the restoration material is closely related to the workability, restoration material which secures longer work hours is necessary when directly restoring a complex form of body. Therefore we experimented on the work-time, color variation and workability as time passes by making mixtures of Epoxy putty and Baked clay in different ratios. As a result of the experiment, the mixture ratio of OS8:RQ2 turned out to be the most effective ratio.

Development of a Thermoplastic Oral Compensator for Improving Dose Uniformity in Radiation Therapy for Head and Neck Cancer (두경부암 방사선치료 시 선량 균일도 향상을 위한 Thermoplastic 구강 보상체의 개발)

  • Choi, Joon-Yong;Won, Young-Jin;Park, Ji-Yeon;Kim, Jong-Won;Moon, Bong-Ki;Yoon, Hyong-Geun;Moon, Soo-Ho;Jeon, Jong-Byeong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.269-278
    • /
    • 2012
  • Aquaplast Thermoplastic (AT) is a tissue-equivalent oral compensator that has been developed to improve dose uniformity at the common boundary and around the treated area during radiotherapy in patients with head and neck cancer. In order to assess the usefulness of AT, the degree of improvement in dose distribution and physical properties were compared to those of oral compensators made using paraffin, alginate, and putty, which are materials conventionally used in dental imprinting. To assess the physical properties, strength evaluations (compression and drop evaluations) and natural deformation evaluations (volume change over time) were performed; a Gafchromic EBT2 film and a glass dosimeter inserted into a developed phantom for dose verification were used to measure the common boundary dose and the beam profile to assess the dose delivery. When the natural deformation of the oral compensators was assessed over a two-month period, alginate exhibited a maximum of 80% change in volume from moisture evaporation, while the remaining tissue-equivalent properties, including those of AT, showed a change in volume that was less than 3%. In a free-fall test at a height of 1.5 m (repeated 5 times as a strength evaluation), paraffin was easily damaged by the impact, but AT exhibited no damage from the fall. In compressive strength testing, AT was not destroyed even at 8 times the force needed for paraffin. In dose verification using a glass dosimeter, the results showed that in a single test, the tissue-equivalent (about 80 Hounsfield Units [HU]) AT delivered about 4.9% lower surface dose in terms of delivery of an output coefficient (monitor unit), which was 4% lower than putty and exhibited a value of about 1,000 HU or higher during a dose delivery of the same formulation. In addition, when the incident direction of the beam was used as a reference, the uniformity of the dose, as assessed from the beam profile at the boundary after passing through the oral compensators, was 11.41, 3.98, and 4.30 for air, AT, and putty, respectively. The AT oral compensator had a higher strength and lower probability of material transformation than the oral compensators conventionally used as a tissue-equivalent material, and a uniform dose distribution was successfully formed at the boundary and surrounding area including the mouth. It was also possible to deliver a uniformly formulated dose and reduce the skin dose delivery.

Histologic findings of three-wall intrabony defects around dental implants using different grafting materials in beagle dogs (수종의 골이식재를 이용한 성견의 임플란트 주위 3면 골내낭의 조직학적 관찰)

  • Moon, Hee-Il;Moon, Sang-Kwon;Shim, Chang-sung;Shim, Jung-Sung;Lee, Yong-Keun;Cho, Kyu-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.439-455
    • /
    • 2003
  • 연구목적 : SLA surface dental implant 주위의 3면 골내낭에서 xenogeneic demineralized bone matric putty, porous ${\beta}$-tri-calcium phosphate, 새로이 개발된 non-crystalline calcium phosphate glass를 사용한 치료를 조직학적으로 비교 평가하기 위한 것이다. 연구방법 : 실험동물로는 15개월에서 18개월 사이의 12kg에서 15kg 정도되는 성견을 사용하였다. 20개의 SLA surface implant가 사용되었으며, 성견 하악의 양측에 각각 2개씩 사용되었다. 임플란트 식립전에, 각각의 임플란트 근심면에 straight fissure bur를 이용하여 표준화된 3면 골내앙(근원심 5mm ${\times}$협설 3mm ${\times}$깊이 3mm)을 형성하였다. 형성된 골 결손부에는 demineralized bone matrix putty, porous ${\beta}$-tri-calcium phosphate, non-crystalline calcium phosphate glass를 넣은 것을 각각 실험군으로, 이식재를 넣지 않은 것을 대조군으로 사용하였다. 8주 후에 실험 동물을 희생시키고 조직학적 관찰을 하였다. 결과 : 조직학적 소견상 임플란트 주위에 급성 염증 소견은 보이지 않았으며, non-crystalline calcium phosphate glass은 매우 적은량의 신생골을, ${\beta}$-TCP을 이용한 골내낭에서는 약간의 기저부에서 유래된 신생골이 관찰된다. ${\beta}$-TCP granules 가운데로 상당량의 측면의 골에서 유래된 신생골 형성이 보인다. xenogeneic DBM putty에서는 많은 량의 신생골이 기저부에 형성된 것을 볼수 있으나 대조군과의 차이는 크지 않다. 이식재의 종류와 상관없이 흡수되지 않은 이식재를 임플란트 주위에서 관찰할 수 있었다. 골내낭 안의 이식재들은 모두 connective tissue로 둘러 싸여 있었다. 모든 실험군에서 이식재에서 기인한 신생골 형성과 임플란트 표면에 신생 골유착의 조직학적 증거는 발견되지 않았다.

Analysis of Paint used in Streetcar No. 381 of Registered Culture Property (등록문화재 전차381호의 도료 분석)

  • Kim, Soo Chul;Park, Min Soo;Seo, Jeong Hun
    • Journal of Conservation Science
    • /
    • v.28 no.3
    • /
    • pp.277-283
    • /
    • 2012
  • This study conducted analysis of paint samples from a streetcar No. 381 (Registration Cultural Property No. 467) to identify the characteristics of the modern paint. The samples were analyzed by Microscopic observation, infrared spectroscopy and SEM-EDS. The upper part is consist of 26 layers and the under part is 29 layers. And the layers were painted various thickness from $10{\mu}m$ to $100{\mu}m$, and confirmed that several color had been used. The putty was used for surface treatment before painting. According to the results of infrared spectroscopy, paint specimens were identified as alkyd resin. Some bands such as C-H and C=O stretcing, aromatic, C-H bending, C-O stretching were found in spectra. Inorganic analysis showed that gold color on the surface was used copper-based paint. And type of the putty was lacquer-putty that was consist of kaolin, talc and zinc white.

A comparative study of the improvement after different self-assessment methods of tooth preparation (치아 삭제의 다른 자가 평가 방법 후 개선에 대한 비교 연구)

  • Kim, JungHan;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.220-227
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the degree of tooth preparation abilities of students according to three self-assessment methods. Materials and Methods: forty-eight sophomores in Kyungpook National University College of Dentistry were divided into three experimental groups. Students performed tooth preparation of the left mandibular first molar for full gold crown. They performed self-assessment using the three methods (visual, digital, and putty index self-assessment group), and reperformed tooth preparation. An intraoral scanner was used to scan each tooth model (prepared tooth and unprepared tooth), and data were acquired in standard tessellation language (STL) file format. The STL files of prepared tooth and unprepared tooth were superimposed using the 3-dimensional analysis software (Geomagic control X). And the reduction amount was measured. In the statistical analysis, all values of reduction amount were analyzed with the Wilcoxon signed rank test and Kruskal-Wallis test (α = 0.05). Results: The three self-assessment methods showed statistically significant differences (P < 0.001). The putty index self-assessment group showed the highest reduction in error than the digital self-assessment method. Conclusion: Within limitations of this study, students showed significant differences in improvement of tooth preparation ability according to the three self-evaluation methods.

In vitro evaluation of resonance frequency analysis values to different implant contact ratio and stiffness of surrounding material

  • Kwak, Mu-Seung;Kim, Seok-Gyu
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.428-433
    • /
    • 2013
  • PURPOSE. The present study was aimed to evaluate the influence of implant contact ratio and stiffness of implant-surrounding materials on the resonance frequency analysis (RFA) values. MATERIALS AND METHODS. Seventy resin blocks that had the different amounts (100, 50, 30, 15%) of resin-implant contact (RIC) were fabricated. Ten silicone putty blocks with 100% silicone-implant contact were also made. The implants with ${\phi}5.0mm{\times}13.0mm$ were placed on eighty specimen blocks. The RFA value was measured on the transducer that was connected to each implant by Osstell Mentor. Kruskal-Wallis and Scheffe's tests (${\alpha}$=.05) were done for statistical analysis. RESULTS. The control resin group with 100% RIC had the highest RFA value of 83.9, which was significantly different only from the resin group with 15% RIC among the resin groups. The silicone putty group with 100% contact had the lowest RFA value of 36.6 and showed statistically significant differences from the resin groups. CONCLUSION. Within the limitations of this in vitro study, there was no significant difference in the RFA values among the resin groups with different RIC's except when the RIC difference was more than 85%. A significant increase in the RFA value was observed related to the increase in stiffness of material around implant.