• Title/Summary/Keyword: Purified water

Search Result 646, Processing Time 0.029 seconds

Distribution of THMs at Drinking Water Purification Plants in the East Coast Region of Gangwon-do (강원도 동해안 지역 정수장의 THMs 분포)

  • Huh, In-Ryang;Shin, Yong-Keon;Park, Sung-Bin;Lee, Teak-Soo;Shim, Tae-Heum
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.3
    • /
    • pp.223-229
    • /
    • 2013
  • Objectives: In an effort to examine the distribution of THMs (Trihalomethane) generated from chlorine disinfection by the drinking water treatment plants located on the east coast region of Gangwon-do, this study surveyed the distribution and concentrations of each component of THMs twice per month for 5 years from 2008 to 2012. Fluctuation pattern in the seasonal generation amount was identified. In addition, the correlation between the concentration of organic substances in water and THMs was assessed, along with stability of purified water quality supplied by the water treatment plants on the east coast by analyzing the composition ratio of each component that constitutes THMs and the detection frequency. Method: The research was done on purified water supplied by 29 water treatment plants in 7 cities and counties (Goseong-gun, Sokcho-si, Yangyang-gun, Gangneung-si, Donghae-si, Samcheok-si, Taebaek-si) located in Gangwon-do on the east coast. Water samples were collected twice a month from 2008 to 2012 and were investigate for chloroform, bromodichloromethane (BDCM), dibromochloromethane (DBCM), and bromoform, based on analysis through Purge-Trap (Tekmar 3000) devices using FID-attached GC (HP 6890, Hewlett Packard). Result: THMs concentration detected at Gangneung-si was 0.0086mg/L, Goseong-gun 0.0019mg/L, Donghae-si 0.0099 mg/L, Samcheok-si 0.0016 mg/L, Sokcho-si 0.0057 mg/L, Yangyang-gun 0.0027 mg/L and Taebaek-si 0.0038 mg/L. As the THMs composition rate, chloroform constitutes 51.4% followed bybromodichloromethane 22.3%, bromoform 15.2% and dibromochloromethane 11.1% respectively. Conclusion: Throughout the entire THMs survey areas and period, the maximum concentration was 0.072mg/L, which did not exceed the water quality standards (0.1 mg/L), and the overall average concentration was very low at 0.0044 mg/L.

Influence of D.I. Water Pressure and Purified $N_2$ Gas on the Inter Level Dielectric-Chemical Mechanical Polishing Process (탈이온수의 압력과 정제된 $N_2$ 가스가 ILD-CMP 공정에 미치는 영향)

  • Kim, Sang-Yong;Seo, Yong-Jin;Kim, Chang-Il;Chung, Hun-Sang;Lee, Woo-Sun;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.31-34
    • /
    • 2000
  • It is very important to understand the correlation of between inter layer dielectric(ILD) CMP process and various facility factors supplied to equipment system. In this paper, the correlation between the various facility factors supplied to CMP equipment system and ILD CMP process were studied. To prevent the partial over-polishing(edge hot-spot) generated in the wafer edge area during polishing, we analyzed various facilities supplied at supply system. With facility shortage of D.I. water(DIW) pressure, we introduced an adding purified $N_2(PN_2)$ gas in polishing head cleaning station for increasing a cleaning effect. DIW pressure and PN2 gas factors were not related with removal rate, but edge hot-spot of patterned wafer had a serious relation. We estimated two factors (DIW pressure and PN2 gas) for the improvement of CMP process. Especially, we obtained a uniform planarity in patterned wafer and prohibited more than 90% wafer edge over-polishing. In this study, we acknowledged that facility factors supplied to equipment system played an important role in ILD-CMP process.

  • PDF

Evidence for Existence of a Water-Extractable Anticoagulant in an Earthworm, Lumbricus rubellus

  • Woo, Jeong-Im;Bahk, Yun-Kyung;Yu, Kyoung-Hee;Paik, Seung-R.;Chang, Chung-Soon
    • BMB Reports
    • /
    • v.29 no.6
    • /
    • pp.500-506
    • /
    • 1996
  • We have isolated a water-extracted novel regulator for blood coagulation from an earthworm, Lumbricus rubellus. As a folk remedy, the earthworm has been known to facilitate blood circulation. After complete heat inactivation of endogenous proteases in the earthworm, an anticoagulant(s) was purified through ammonium sulfate fractionation and three consecutive gel permeation chromatography of Sephacryl S-300, Sephadex G-75, and G-150 by measuring activated partial thromboplastin time (APTT) The anticoagulant was further purified to 2,800 fold with a C4 reversed-phase HPLC This activity was stable under heat ($100^{\circ}C$ for 30 min) and acidic conditions (0.4 N HCl). The effects of this partially purified anticoagulant on thrombin were observed with various substrates such as N${\alpha}$-benzoyl-DL-arginine-p-nitroanilide (BApNA), H-D-phenylalanyl-L-pipecoyl-L-arginine-p-nitroanilide (S-2238), N${\alpha}$-p-tosyl-L-arginine methyl ester (TAME), and fibrinogen as a natural substrate. Only TAME hydrolysis, due to an esterase activity of the enzyme, was inhibited among the chromogenic substrates. In addition, the anticoagulant not only inhibited the conversion of fibrinogen to fibrin but also prolonged the fibrin clot formation monitored with the in vitro coagulation test. Based on these observations, we suggest the significance of measuring the ability of antithrombotic drugs to inhibit the esterase activity of thrombin. In this report, it was also shown that the earthworm indeed contained a water-extractable, heat- and acid-stable anticoagulant which could be used as a novel antithrombotic agent.

  • PDF

Understanding on TDS Creep Phenomena of Reverse Osmosis Membranes in Water Purifiers (역삼투막 정수기에서 발생하는 총용존고형물 크리프 현상의 이해)

  • Kang, Sanghyeon;Yun, Sunghan
    • Membrane Journal
    • /
    • v.32 no.2
    • /
    • pp.126-132
    • /
    • 2022
  • Water purifiers have a quite different characteristic in comparison with general membrane water treatment processes in which the running and resting are repeated dozens of times a day. In the case of water purifiers using reverse osmosis membranes, this characteristic makes a phenomenon that the total dissolved solids (TDS) of permeate in water purifiers at the beginning of running shows a higher value than a normal value (TDS reduction is lower than a normal value). It is called "TDS creep". The effects of resting times and feed concentrations on the TDS creep were investigated. The feed flushing, the volume increase in permeate side and the flushing with purified water were applied to reduce TDS creep and the effectiveness were observed. Among these trials, the minimization of concentration between feed and permeate side of reverse osmosis membrane like the flushing with purified water can be an ultimate solution to reduce the TDS creep.

Influence of DI Water Pressure and Purified $N_2$Gas on the Inter Level Dielectric-Chemical Mechanical Polishing Process (탈이온수의 압력과 정제된 $N_2$가스가 ILD-CMP 공정에 미치는 영향)

  • 김상용;이우선;서용진;김창일;장의구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.10
    • /
    • pp.812-816
    • /
    • 2000
  • It is very important to understand the correlation of between inter dielectric(ILD) CMP process and various facility factors supplied to equipment to equipment system. In this paper, the correlation between the various facility factors supplied to CMP equipment system and ILD-CMP process was studied. To prevent the partial over-polishing(edge hot-spot) generated in the wafer edge area during polishing, we analyze various facilities supplied at supply system. With facility shortage of D.I water(DIW) pressure, we introduced an adding purified $N_2$(P$N_2$)gas in polishing head cleaning station for increasing a cleaning effect. DIW pressure and P$N_2$gas factors were not related with removal rate, but edge hot-spot of patterned wafer had a serious relation. We estimated two factors (DIW pressure and P$N_2$gas) for the improvement of CMP process. Especially, we obtained a uniform planarity in patterned wafer and prohibited more than 90% wafer edge over-polishing. In this study, we acknowledged that facility factors supplied to equipment system played an important role in ILD-CMP process.

  • PDF

Effects of Consumable on STI-CMP Process (STI-CMP 공정에서 Consumable의 영향)

  • 김상용;박성우;정소영;이우선;김창일;장의구;서용진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.185-188
    • /
    • 2001
  • Chemical mechanical polishing(CMP) process is widely used for global planarization of inter-metal dielectric (IMD) layer and inter-layer dielectric (ILD) for deep sub-micron technology. However, as the IMD and ILD layer gets thinner, defects such as micro-scratch lead to severe circuit failure, which affect yield. In this paper, for the improvement of CMP Process, deionized water (DIW) pressure, purified $N_2$ (P$N_2$) gas, slurry filter and high spray bar were installed. Our experimental results show that DIW pressure and P$N_2$ gas factors were not related with removal rate, but edge hot-spot of patterned wafer had a serious relation. Also, the filter installation in CMP polisher could reduce defects after CMP process, it is shown that slurry filter plays an important role in determining consumable pad lifetime. The filter lifetime is dominated by the defects. However, the slurry filter is impossible to prevent defect-causing particles perfectly. Thus, we suggest that it is necessary to install the high spray bar of de-ionized water (DIW) with high pressure, to overcome the weak-point of slurry filter. Finally, we could expect the improvements of throughput, yield and stability in the ULSI fabrication process.

  • PDF

Investigation on alkalinity of pore solution and microstructure of hardened cement-slag pastes in purified water

  • Hu, Ya-Ru;Zuo, Xiao-Bao;Li, Xiang-Nan;Jiang, Dong-Qi
    • Advances in concrete construction
    • /
    • v.12 no.6
    • /
    • pp.507-515
    • /
    • 2021
  • To evaluate the influence of slag on the alkalinity of pore solution and microstructure of concrete, this paper performs a leaching experiment on hardened cement-slag pastes (HCSP) slice specimens with different slag content in purified water. The pH value of pore solution, average porosity, morphology, phase composition and Ca/Si of HCSP specimens in the leaching process are measured by solid-liquid extraction, saturated-dried weighing, scanning electron microscopy-energy dispersive spectrometry (SEM-EDS) and X-ray diffraction (XRD). Results shows that the addition of slag can mitigate an increase in porosity and a decrease in Ca/Si of HCSP in the leaching process. Besides, an appropriate slag content can improve the microstructure so as to obtain the optimum leaching resistance of HCSP, which can guarantee the suitable alkalinity of pore solution to prevent a premature corrosion of reinforced bar. The optimum slag content is 40% in HCSP with a water-binder ratio of 0.45, and an excessive slag causes a significant decrease in the alkalinity of pore solution, resulting in a loss of protection on reinforced bar in HCSP.

Change of General Bacteria and Coliform Group in Drinking Water according to Storage Condition (음용수의 저장에 따른 일반세균과 대장균군의 변화)

  • 양지영;김병철;이재우
    • Journal of Food Hygiene and Safety
    • /
    • v.14 no.4
    • /
    • pp.433-435
    • /
    • 1999
  • The number of viable microorganism in drinking water was monitored according to storage temperature and storage period. The number of general bacteria in underground water was 10$^2$~10$^{5}$ CFU/ml and that of coliform group was decreased after 7days. The number of general bacteria in bottle water was increased until 7days but decreased after that day. Coliform group in bottle water were detected only 1 sample. The number of general bacteria in purified water was 10$^3$~10$^4$CFU/ml and 10$^2$~10$^4$CFU/m1 at 8$^{\circ}C$ and $25^{\circ}C$, respectively. Coliform group were not detected in purified water.

  • PDF

Synthesis of Biosurfactant-Based Silver Nanoparticles with Purified Rhamnolipids Isolated from Pseudomonas aeruginosa BS-161R

  • Kumar, C. Ganesh;Mamidyala, Suman Kumar;Das, Biswanath;Sridhar, B.;Devi, G. Sarala;Karuna, Mallampalli SriLakshmi
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.7
    • /
    • pp.1061-1068
    • /
    • 2010
  • The biological synthesis of nanoparticles has gained considerable attention in view of their excellent biocompatibility and low toxicity. We isolated and purified rhamnolipids from Pseudomonas aeruginosa strain BS-161R, and these purified rhamnolipids were used to synthesize silver nanoparticles. The purified rhamnolipids were further characterized and the structure was elucidated based on one- and two-dimensional $^1H$ and $^{13}C$ NMR, FT-IR, and HR-MS spectral data. Purified rhamnolipids in a pseudoternary system of n-heptane and water system along with n-butanol as a cosurfactant were added to the aqueous solutions of silver nitrate and sodium borohydride to form reverse micelles. When these micelles were mixed, they resulted in the rapid formation of silver nanoparticles. The synthesized nanoparticles were characterized by UV-Visible spectroscopy, transmission electron microscopy, and energy dispersive X-ray spectroscopy (EDS). The nanoparticles formed had a sharp adsorption peak at 410 nm, which is characteristic of surface plasmon resonance of the silver nanoparticles. The nanoparticles were monodispersed, with an average particle size of 15.1 nm (${\sigma}={\pm}5.82$ nm), and spherical in shape. The EDS analysis revealed the presence of elemental silver signal in the synthesized nanoparticles. The formed silver nanoparticles exhibited good antibiotic activity against both Grampositive and Gram-negative pathogens and Candida albicans, suggesting their broad-spectrum antimicrobial activity.

The Control Realities of Water Purifier in Northern Part of Gyeonggi-do. (경기북부지역의 정수기물 관리실태 조사)

  • 박용배;손진석;강정복;방선재;김중범;최명순
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • There are lots of waterborne diseases which are caused by pathogenic microorganisms disseminated in contaminated environment. The purpose of this study is to investigate the status of water qualify and in order to investigate the sanitary condition of water purifier in northern part of Gyeonggi-do. We analyzed pathogenic microorganisms and 44 items of drinking water criteria from April to July in 2002. The results were as follows. 1. In 774 samples of water purifier, Pathogenic bacteria(salmonella, E coli O-157, O-26, O-111, shigella, pseudomonas etc.) were not isolated and total coliforms not detected. 2. About 76.5% of the water with purifier are found to be appropriated to the drinking water quality criteria. but 182 samples(23.5%) were without limits of drinking water criteria. 3. In the microbiological examination, 774 samples of purified water showed that 169 samples(21.9%) exceed the range of recommended limits(100 $CFU/m{\ell}$) to the total viable bacterial counts by pour plate method.