• Title/Summary/Keyword: Pure Ti

Search Result 598, Processing Time 0.03 seconds

Thermoelectric Properties of n-Type Half-Heusler Compounds Synthesized by the Induction Melting Method

  • Du, Nguyen Van;Lee, Soonil;Seo, Won-Seon;Dat, Nguyen Minh;Meang, Eun-Ji;Lim, Chang-Hyun;Rahman, Jamil Ur;Kim, Myong Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.6
    • /
    • pp.342-345
    • /
    • 2015
  • The n -type Hf0.25Zr0.25Ti0.5NiSn0.998Sb0.002 Half-Heusler (HH) alloy composition was prepared by using the induction melting method in addition to the mechanical grinding, annealing, and spark plasma sintering processes. Analysis of X-ray diffraction (XRD) results indicated the formation of a pure phase HH structured compound. The electrical and thermal properties at temperatures ranging from room temperature to 718 K were investigated. The electrical conductivity increased with increasing temperatures and demonstrated nondegenerate semiconducting behavior, and a large reduction in the thermal conductivity to the value of 2.5 W/mK at room temperature was observed. With the power factor and thermal conductivity, the dimensionless figure of merit was increased with temperature and measured at 0.94 at 718 K for the compound synthesized by the induction melting process.

EVALUATION OF BONE RESPONSE BY RESONANCE FREQUENCY ANALYSIS OF ANODIZED IMPLANTS

  • Roh Hyun-Ki;Heo Seong-Joo;Rhyu In-Chul
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.745-750
    • /
    • 2005
  • Statement of problem. Resonance frequency analysis has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized data using RFA. Purpose. This study was performed to evaluate RFA value changes in two anodized implant groups. Material and method. Among a total of 24 implants, twelve screw shaped implants as a test group (H2-R8.5) were manufactured, which had a pitch-height of 0.4 mm, an outer diameter of 4.3 mm, a length of 8.5 mm, and external hexa-headed, were turned from 5 mm rods of commercially pure titanium (ASTM Grade IV, Warantec Co., Seoul, Korea), and another twelve implants as a control group were $Br{\aa}nemark$ Ti-Unite MK4 (diameter 4.0 mm, length 8.5 mm). Each group was installed in tibia of rabbit. Two implants were placed in each tibia (four implants per rabbit). Test two implants were inserted in right side and control two in left side. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, and 12 weeks later and evaluated the RFA changes. Results. Mean and SD of baseline ISQ values of test group were $75.0{\pm}3.4$ and $68.7{\pm}8.1$ for control group. Mean and SO of ISQ values 12 weeks after implant insertion were $73.2{\pm}4.7$ for test group and $72.6{\pm}3.9$ for control group. There were no statistically significant differences between groups in ISQ values after 3 months (P>0.05). From the data, RFA gains after 3 months were calculated, and there was statistically significant difference between groups (P<0.05). Conclusion. Although there were RFA changes between groups, implant stability after experimental period shows alike tendency and good bone responses.

Pyroelectric Peyformance Evaluation of Pure PZT and Alternately Deposited PZT/PT Thin Films (PZT 순수박막과 PZT/PT 교차박막의 적외선 감지 특성 비교)

  • Ko, Jong-Soo;Kwak, Byung-Man
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1001-1007
    • /
    • 2002
  • To improve the performance of the PZT thin flms, each PZT and PT layer was alternately deposited on a Pt/Ti/Si$_3$N$_4$/SiO$_2$/Si substrate by a modified sol-gel solid precursor technique. For comparison, PZT thin films were also prepared with an identical method under the same conditions. XRD measurement revealed that the diffraction pattern of the multilayer film was due to the superimposition of the PZT and PT patterns. At 1㎑, a dielectric constant of 389 and 558, a dielectric loss of 1.2% and 1.1% were obtained for the PZT/PT and PZT thin films, respectively. If we consider the PT dielectric constant to be 260, it is clear that the dielectric constant of alternately deposited PZT/PT thin films was well adjusted. The PZT/PT thin film showed a low dielectric constant and a similar dielectric loss compared with those of the PZT film. The figures of merit on detectivity for the PZT/PT and PZT thin films were 20.3$\times$10$\^$-6/㎩$\^$-$\sfrac{1}{2}$/, and 18.7$\times$10$\^$-6/㎩$\^$-$\sfrac{1}{2}$/, and the figures of merit on voltage response were 0.038㎡/C and 0.028 ㎡/C, respectively. The high figures of merit for the PZT/PT film were ascribed to its relatively low dielectric constant when compared to the PZT thin films.

Manufacturing Ti-Alloy Frames of Classes with High-Precision Laser Beam Welding (초정밀 레이저용접을 이용한 티타늄 안경테 제조)

  • 황용화;김수성;이형권;민덕기;고진현
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.2
    • /
    • pp.1-8
    • /
    • 2000
  • An attempt was made to develop commercially pure titanium frames of glasses with a high-precision laser beam welding machine, in which a resonator with 12kw of the peak power and 200 W of maximum mean power has the capacity of variable in the range of 0.08~10 ms pulse width. In addition the optical fiber beam transmission with 400 ${\mu}{\textrm}{m}$ of the core diameter and a weld chamber to contain specimens in the inert gas atmosphere were also designed and used. In the present study. titanium frames of glasses parts such as temple plus spring hinge. bridge and top bar were experimentally manufactured by utilizing the optimum welding parameters with the optical fiber of GI 400 ${\mu}{\textrm}{m}$, 2.9J energy per pulse, and focussing position for Tee and butt joints. The titanium welded joints with laser beam welding did not reveal any severe weld defects or weld bead appearance except some pores in the weld section.

  • PDF

Interaction between RuO2 and Carbon Nanotubes - Photoemission and X-ray Absorption Study

  • Lee, Seung-Youb;Kim, Yoo-Seok;Jeon, Chel-Ho;Ihm, Kyu-Wook;Kang, Tai-Hee;Park, Chong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.567-567
    • /
    • 2012
  • Since the carbon nanotubes (CNTs) have extraordinary material properties, many researchers are trying to make a practical application in various fields [1]. In particular, the high surface area of CNTs was fascinated for nano-template on the catalytic system. $RuO_2$ coated CNTs are useful functional nano-composites in many applications, including super capacitors, fuel cells, biosensors, and field emitters. However, the research of interaction between CNTs and $RuO_2$ was not satisfied with various fields [2]. In this study, we will introduce the change of chemical and electrical state of $RuO_2$/CNTs at different temperatures by synchrotron radiation photoemission spectroscopy (SRPES). The t-MWCNTs used in this experiment were grown on the Ni/TiN/Si substrates by chemical vapor deposition. $RuO_2$ of 4-20 nm in thickness was deposited on the t-MWNTs by sputter. The SRPES measurements were carried out at the 4B1 beamline of the Pohang Accelerator Laboratory in Korea. The result of XPS measurement indicates that the deposited $RuO_2$ on the CNTs was reduced into pure Ru at above $300^{\circ}C$. And we confirmed that the effective work function of $RuO_2$/CNTs was decreased with increasing temperature.

  • PDF

Study on the Manufacturing Technology Applied on Iron Axes of Proto-Three Kingdoms excavated from Yangchon, Gimpo (김포 양촌유적 출토 원삼국시대 철부에 적용된 제작기술 검토)

  • Yu, Jae Eun;Lee, Jae Sung
    • Journal of Conservation Science
    • /
    • v.29 no.4
    • /
    • pp.367-378
    • /
    • 2013
  • Microstructures and nonmetallic inclusions of five forged iron axes and one cast iron axe were analyzed. The axes were excavated from the Proto-Three Kingdom Period site located in Yangchon, Gimpo. The forging objects were made of almost pure iron and low carbon steel, and only one among five were quenched after its figuration. Malleable cast iron structures showing on the casting suggest that the decarbonized casting method were applied. According to the results of nonmetallic inclusion analysis, the axes were produced by hammering the iron bloom which was attained with low-temperature -solid-reduction-method. Showing higher Fe content over $SiO_2$, it is assumed that the re-collecting rate of Fe was low because of the insufficient forging temperature and the impurities were included during the smelting process. It is assumed that the lime was used as a preparation because of detecting high Ca contents.

Synthesis of Nanocrystalline ZnFe2O4 by Polymerized Complex Method for its Visible Light Photocatalytic Application: An Efficient Photo-oxidant

  • Jang, Jum-Suk;Borse, Pramod H.;Lee, Jae-Sung;Jung, Ok-Sang;Cho, Chae-Ryong;Jeong, Euh-Duck;Ha, Myoung-Gyu;Won, Mi-Sook;Kim, Hyun-Gyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.8
    • /
    • pp.1738-1742
    • /
    • 2009
  • Nanocrystalline Zn$Fe_2O_4$ oxide-semiconductor with spinel structure was synthesized by the polymerized complex (PC) method and investigated for its photocatalytic and photoelectric properties. The observation of a highly pure phase and a lower crystallization temperature in Zn$Fe_2O_4$ made by PC method is in total contrast to that was observed in Zn$Fe_2O_4$ prepared by the conventional solid-state reaction (SSR) method. The band gap of the nanocrystalline Zn$Fe_2O_4$ determined by UV-DRS was 1.90 eV (653 nm). The photocatalytic activity of Zn$Fe_2O_4$ prepared by PC method as investigated by the photo-decomposition of isopropyl alcohol (IPA) under visible light (${\geq}$ 420 nm) was much higher than that of the Zn$Fe_2O_4$ prepared by SSR as well as Ti$O_{2-x}N_x$. High photocatalytic activity of Zn$Fe_2O_4$ prepared by PC method was mainly due to its surface area, crystallinity and the dispersity of platinum metal over Zn$Fe_2O_4$.

Antibacterial effect of urushiol on E. faecalis as a root canal irrigant

  • Kim, Sang-Wan;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.54-59
    • /
    • 2017
  • Objectives: The purpose of this study was to compare the antibacterial activity of urushiol against Enterococcus faecalis (E. faecalis) to that of NaOCl. Materials and Methods: The canals of thirty two single rooted human teeth were instrumented with Ni-Ti files (ProTaper Next X1, X2, X3, Dentsply). A pure culture of E. faecalis ATCC 19433 was prepared in sterile brain heart infusion (BHI) broth. The teeth were submerged in the suspension of E. faecalis and were incubated at $37^{\circ}C$ for 7 days to allow biofilm formation. The teeth were randomly divided into three experimental groups according to the irrigant used, and a negative control group where no irrigant was used (n = 8). Group 1 used physiologic normal saline, group 2 used 6% NaOCl, and group 3 used 10 wt% urushiol solution. After canal irrigation, each sample was collected by the sequential placement of 2 sterile paper points (ProTaper NEXT paper points, size X3, Dentsply). Ten-fold serial dilutions on each vials, and 100 µL were cultured on a BHI agar plate for 8 hours, and colony forming unit (CFU) analysis was done. The data were statistically analyzed using Kruskal-Wallis and Mann-whitney U tests. Results: Saline group exhibited no difference in the CFU counts with control group, while NaOCl and urushiol groups showed significantly less CFU counts than saline and control groups (p < 0.05). Conclusions: The result of this study suggests 10% urushiol and 6% NaOCl solution had powerful antibacterial activity against E. faecalis when they were used as root canal irrigants.

Characteristics of Ir-Re Thin Films on WC for Lens Glass Molding by Ion Beam Assisted DC Magnetron Sputtering (Ion beam assisted DC magnetron sputtering에 대한 렌즈 유리 성형용 WC 합금의 Ir-Re 박막 특성)

  • Park, Jong-Seok;Park, Burm-Su;Kang, Sang-Do;Yang, Kook-Hyun;Lee, Kyung-Ku;Lee, Doh-Jae;Lee, Kwang-Min
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.3
    • /
    • pp.88-93
    • /
    • 2008
  • Ir-Re thin films with Ti interlayer were deposited onto the tungsten carbide substrate by ion beam assisted DC magnetron sputtering. The Ir-Re films were prepared with targets of having two atomic percent of 7:3 and 5:5. The microstructure and surface analysis of the specimen were conducted by using SEM, XRD and AFM. Mechanical properties such as hardness and adhesion strength of Ir-Re thin film also were examined. The interlayer of pure titanium was formed with 100 nm thickness. The film growth of Ir-30at.%Re was faster than that of Ir-50at.%Re in the same deposition conditions. Ir-Re thin films consisted of dense and columnar structure irrespective of the different target compositions. The values of hardness and adhesion strength of Ir-30at.%Re thin film coated on WC substrate were higher than those of Ir-50at.%Re thin film.

Ballistic Properties of Zr-based Amorphous Alloy Surface Composites Fabricated by High-Energy Electron-Beam Irradiation (고에너지 전자빔 투사방법으로 제조된 Zr계 비정질 합금 표면복합재료의 탄도충격 성능)

  • Do, Jeonghyeon;Jeon, Changwoo;Nam, Duk-Hyun;Kim, Choongnyun Paul;Song, Young Buem;Lee, Sunghak
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.12
    • /
    • pp.1047-1055
    • /
    • 2010
  • The objective of this study is to investigate the ballistic properties of Zr-based amorphous alloy surface composites fabricated by high-energy electron-beam irradiation. The mixture of Zr-based amorphous powders and $LiF+MgF_2$ flux powders was deposited on a pure Ti substrate, and then an electron beam irradiated this powder mixture to fabricate a one-layer surface composite. A four-layer surface composite, in which the composite layer thickness was larger than 3 mm, was also fabricated by irradiating the deposited powder mixture by an electron beam three times on the one-layer surface composite. The microstructural analysis results indicated that a small amount of fine crystalline particles were homogeneously distributed in the amorphous matrix of the surface composite layer. According to the ballistic impact test results, the surface composite layers effectively blocked a fast traveling projectile, while many cracks were formed at the composite layers, and thus the surface composite plates were not perforated. The surface composite layer containing ductile ${\beta}$ dendritic phases showed a better ballistic performance than the one without dendrites because dendritic phases hindered the propagation of shear bands or cracks.