• 제목/요약/키워드: Pure Potential

Search Result 446, Processing Time 0.024 seconds

Left Atrial Thrombi in Patients With Mitral Stenosis (Risk Factors Related to left Atrial Thrombosis) (승모판협착증 환자의 좌심방혈전)

  • Kim, Kwang-Ho;Hong, Sung-Nok
    • Journal of Chest Surgery
    • /
    • v.15 no.2
    • /
    • pp.204-212
    • /
    • 1982
  • The presence of left atrial thrombus in mitral stenosis has been reported to be associated with several factors. These are age, sex, presence of atrial fibrillation, episodes of congestave heart failure, calcification of mitral valve, embolic episode, etc. Since none of these single factor has been always related to the presence of left atrial thrombus, related risk factors to left atrial thrombosis were studied in patients with mitral stenosis using chi square test. We had operated on 191 cases of mitral valvular heart disease from Jan. 1978 to June 1981 at Severance Hospital, Yunsei University College of Medicine. The left atrial thrombi were present in 41 cases among 191 cases of mitral valvular heart disease and it was present in 31 cases among 89 cases of pure mitral stenosis. Only 10 cases among 74 cases of mitral stenoregurgitation had left atrlal thrombi, whereas no left atrlal thrombus was found in patients with pure mitral regurgitation. Related risk factors studied herein were sex, episodes of congestive heart failure, atrial fibrillation, pulmonary capillary wedge pressure, mitral valve area calculated by Gorlin and Gorlin`s formula cardiac output and left atrial dimension by echocardiogram. In this study presence of atrial fibrillation was deemed to be one of the most potential risk factors and other factors of age, duration of symptoms, episode of embolization, calclfication of mitral valve, associated aortic and tricuspid valve disease, ejection fraction of left ventricle by cineangiocardiogram and echocardiogram were not significantly related to the presence of left atrlal thrombi in a statistical viewpoint.

  • PDF

A Study on the Improvement on the Target Structure in a Magnetron Sputtering Apparatus (마그네트론 스퍼터링 장치의 타겟구조 개선에 관한 연구)

  • Bae, Chang-Hwan;Lee, Ju-Hee;Han, Chang-Suk
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • The cylindrical magnetron sputtering has not been widely used, although this system is useful for only certain types of applications such as fiber coatings. This paper presents electrode configurations which improved the complicacy of the target assembly by using the positive voltage power supply. It is a modified type which has a target constructed with a large cylindrical part, a conical part and a small cylindrical part. When positive voltage was applied to an anode, a stable glow discharge was established and a high deposition rate was obtained. The substrate bias current was monitored to estimate the effect of ion bombardment. As a result, it was found that the substrate current was large. With cylindrical and conical cathode magnetron sputter deposition on the surface of the substrate to prevent re-sputtering, ion impact because it can increase the effectiveness with excellent ductility and adhesion of Ti film deposition can be obtained. We board at the front end of the ground resistance of $5\;k{\Omega}$ attached to the substrate potential can be controlled easily, and Ti film deposition with excellent adhesion can be obtained. Microstructure and morphology of Ti films deposited on pure Cu wires were investigated by scanning electron microscopy in relation to preparation conditions. High level ion bombardment was found to be effective in obtaining a good adhesion for Cu wire coatings.

Improved 1,3-Propanediol Synthesis from Glycerol by the Robust Lactobacillus reuteri Strain DSM 20016

  • Ricci, Maria Antonietta;Russo, Annamaria;Pisano, Isabella;Palmieri, Luigi;de Angelis, Maria;Agrimi, Gennaro
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.6
    • /
    • pp.893-902
    • /
    • 2015
  • Various Lactobacillus reuteri strains were screened for the ability to convert glycerol to 1,3-propanediol (1,3-PDO) in a glycerol-glucose co-fermentation. Only L. reuteri DSM 20016, a well-known probiotic, was able to efficiently carry out this bioconversion. Several process strategies were employed to improve this process. Co2+ addition to the fermentation medium, led to a high product titer (46 g/l) of 1,3-PDO and to improved biomass synthesis. L. reuteri DSM 20016 produced also ca. 3 µg/g of cell dry weight of vitamin B12, conferring an economic value to the biomass produced in the process. Incidentally, we found that L. reuteri displays the highest resistance to Co2+ ions ever reported for a microorganism. Two waste materials (crude glycerol from biodiesel industry and spruce hydrolysate from paper industry) alone or in combination were used as feedstocks for the production of 1,3-PDO by L. reuteri DSM 20016. Crude glycerol was efficiently converted into 1,3-PDO although with a lower titer than pure glycerol (33.3 vs. 40.7 g/l). Compared with the fermentation carried out with pure substrates, the 1,3-PDO produced was significantly lower (40.7 vs. 24.2 g/l) using cellulosic hydrolysate and crude glycerol, but strong increases of the maximal biomass produced (2.9 vs 4.3 g/l CDW) and of the glucose consumption rate were found. The results of this study lay the foundation for further investigations to exploit the biotechnological potential of L. reuteri DSM 20016 to produce 1,3-PDO and vitamin B12 using industry byproducts.

Carbon Dioxide Capture and Carbonate Synthesis via Carbonation of KOH-Dissolved Alcohol Solution (KOH-알코올 용액의 탄산화를 통한 이산화탄소 포집 및 탄산염 합성)

  • Kim, Eung-Jun;Han, Sang-Jun;Wee, Jung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.11
    • /
    • pp.597-606
    • /
    • 2015
  • This work investigates the carbonation of KOH-dissolved methanol and ethanol solution systems carried out for $CO_2$ fixation. Potassium methyl carbonate (PMC) and potassium ethyl carbonate (PEC) were synthesized during the reaction in each solution as the solid powder, and they were characterized in detail. The amount of $CO_2$ chemically absorbed to produce the PMC and PEC precipitates were calculated to be 97.90% and 99.58% of their theoretical values, respectively. In addition, a substantial amount of $CO_2$ was physically absorbed in the solution during the carbonation. PMC precipitates were consisted of the pure PMC and $KHCO_3$ with the weight ratio of 5:5, respectively. PEC precipitates were also mixture of the pure PEC and $KHCO_3$ with the weight ratio of 8:2, respectively. When these two precipitates were dissolved in excess water, methanol and ethanol were regenerated remaining solid $KHCO_3$ in the solutions. Therefore, the process has the potential to be one of the efficient options of CCS and CCU technologies.

Measurement of Thermo-physical Properties of Organic Phase Change Materials using Modified T-history Method (수정된 T-history 법을 이용한 유기 상전이 물질들의 열 물성 측정)

  • Dao, Van-Duong;Choi, Hong-Ki;Choi, Ho-Suk;Oh, Jun-Taek;Kim, Jong-Kuk
    • Korean Chemical Engineering Research
    • /
    • v.48 no.1
    • /
    • pp.93-97
    • /
    • 2010
  • In this study, we have measured the thermo-physical properties of pure organic phase change materials (PCMs) and their mixtures which have the melting points from 0 to $15^{\circ}C$ by using a modified T-history method. These organic PCMs can be used as coolant materials for packaging and shipping of vaccines. Through measuring the thermophysical properties of pure paraffins, we were able to know that we could improve the reliability of measurement if we considered the melting point of each material and subsequently decided an optimum coolant temperature for each system. The modified T-history method showed a potential usefulness for reliably measuring thermo-physical properties of organic mixtures with avoiding possible inaccuracy of measurement due to using a small amount of sample at DSC measurement.

Adipose-Derived Stem Cells Improve Efficacy of Melanocyte Transplantation in Animal Skin

  • Lim, Won-Suk;Kim, Chang-Hyun;Kim, Ji-Young;Do, Byung-Rok;Kim, Eo Jin;Lee, Ai-Young
    • Biomolecules & Therapeutics
    • /
    • v.22 no.4
    • /
    • pp.328-333
    • /
    • 2014
  • Vitiligo is a pigmentary disorder induced by a loss of melanocytes. In addition to replacement of pure melanocytes, cocultures of melanocytes with keratinocytes have been used to improve the repigmentation outcome in vitiligo treatment. We previously identified by in vitro studies, that adipose-derived stem cells (ADSCs) could be a potential substitute for keratinocytes in cocultures with melanocytes. In this study, the efficacy of pigmentation including durability of grafted melanocytes and short-term safety was examined in the nude mouse and Sprague-Dawley rat after grafting of primary cultured human melanocytes, with or without different ratios of primary cultured human ADSCs. Simultaneous grafting of melanocytes and ADSCs, which were separately cultured and mixed on grafting at the ratios of 1:1, 1:2, or 1:3, showed better efficacy than that of pure melanocytes. Grafting of melanocytes cocultured with ADSCs resulted in a similar outcome as the grafting of cell mixtures. Skin pigmentation by melanocytes : ADSCs at the ratios of 1:1 and 1:2 was better than at 1:3. No significant difference was observed between the 1-week and 2-week durations in coculturing. Time-course microscopic examination showed that the grafted melanocytes remained a little longer than 6-week post-grafting. No inflammatory cell infiltration was observed in the grafted skin and no melanocytes were detectable in other organs. Collectively, grafting of melanocytes and ADSCs was equally safe and more effective than grafting of melanocytes alone. Despite the absence of significant differences in efficacy between the group of 1:1 and that of 1:2 ratio, 1:2 ratio for 1-week coculturing may be better for clinical use from the cost-benefit viewpoint.

Characteristics of Welds of Pure Titanium Plate Using Ultrasonic Attenuation (초음파 감쇠를 이용한 순 티타늄 판재의 용접부 특성)

  • Seon, Sang-Won;Yi, Won;Park, Hee-Dong;Hwang, Yeong-Tak
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.205-211
    • /
    • 2013
  • This paper studies on mechanical properties, fractures, and ultrasonic characteristics of Pure Titanium welds using ultrasonic attenuation. Ti specimen was made by using AR purge gas. When the titanium weld specimen is fractured, Tensile tests were conducted in order to observe the ultrasonic signal changes. A scanning electron microscope(SEM) was used to observe changes in failure surface and an ultrasonic normal probe with the central frequency of 4 MHz was used to obtain ultrasonic signals. As a result, the value of the mechanical properties in the weld zone was lower than that in the base zone and heat affected zone(HAZ) from Ti. Also the grain size in the weld zone was bigger than that in the weld zone and HAZ from Ti. Ultrasonic signals using a RMS method presents correlation between envelope area and the tensile strength. Consequently, the ultrasonic method could be potential tool for integrity evaluation of the Ti weld zone.

Grindability of Cast Ti-X%Zr(X=10,20,40) Alloys for Dental Applications (치과주조용 Ti-X%Zr(X=10,20,40)합금의 연삭성)

  • Jung, Jong-Hyun;Noh, Hyeong-Rok
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.263-270
    • /
    • 2011
  • Purpose: The grindability of binary Ti-X%Zr(X=10,20,40) alloys in order to develop a Ti alloy with better machinability than unalloyed titanium has been evaluated. Methods: Experimental Ti-Zr alloys were made in an argon-arc melting furnace. Slabs of experimental alloys were ground using a SiC abrasive wheel on an electric handpiece at circumferential speeds(12000,18000,25000 or 30000rpm) by applying a force(200gr). Grinding rate was evaluated by measuring the amount of metal volume removed after grinding for 1 minute and the volume ratio of metal removed compared to the wheel material lost, which was calculated from the diameter loss (grinding ratio). Experimental datas were compared to those for cp Ti(commercially pure titanium) and Ti-6%Al-4%V alloy were used controls. Results: It was observed that the grindability of Ti-Zr alloys increased with an increase in the Zr concentration. More, they are higher than cp Ti, particularly the Ti-20%Zr alloy exhibited the highest grindability at all circumferential speeds. There was significant difference in the grinding rate and grinding ratio between Ti-20%Zr alloy and cp Ti at any speed(p<0.05). Conclusion: By alloying with Zr, the Ti exhibited better grindability at all circumferential speeds. the Ti-20%Zr alloy has a great potential for use as a dental machining alloy.

Enhancement of Methanol Gas Sensitivity of Cu Intermediate ITO Film Gas Sensors

  • Shin, Chang-Ho;Chae, Joo-Hyun;Kim, Yu-Sung;Jeong, Cheol-Woo;Kim, Dae-Il
    • Korean Journal of Materials Research
    • /
    • v.20 no.5
    • /
    • pp.267-270
    • /
    • 2010
  • Sn doped $In_2O_3$ (ITO) and ITO/Cu/ITO (ICI) multilayer films were prepared on glass substrates with a reactive radio frequency (RF) magnetron sputter without intentional substrate heating, and then the influence of the Cu interlayer on the methanol gas sensitivity of the ICI films were considered. Although both ITO and ICI film sensors had the same thickness of 100 nm, the ICI sensors had a sandwich structure of ITO 50 nm/Cu 5 nm/ITO 45 nm. The ICI films showed a ten times higher carrier density than that of the pure ITO films. However, the Cu interlayer may also have caused the decrement of carrier mobility because the interfaces between the ITO and Cu interlayer acted as a barrier to carrier movement. Although the ICI films had two times a lower mobility than that of the pure ITO films, the ICI films had a higher conductivity of $3.6{\cdot}10^{-4}\;{\Omega}cm$ due to a higher carrier density. The changes in the sensitivity of the film sensors caused by methanol gas ranging from 50 to 500 ppm were measured at room temperature. The ICI sensors showed a higher gas sensitivity than that of the ITO single layer sensors. Finally, it can be concluded that the ICI film sensors have the potential to be used as improved methanol gas sensors.

A study on the effect of tooth ash and hydroxylapatite root implantation on preservation of alveolar ridge (치아회분(齒牙灰粉) 및 인공(人工) 수산화(水酸化) 아파타이트 치근(齒根)이 치조제(齒槽堤) 유지(維持)에 미치는 영향(影響))

  • Hong, Soon-Yong;Yoon, Chang-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.23 no.1
    • /
    • pp.13-37
    • /
    • 1985
  • Biocompatibility of dense synthetic hydroxylapatite is well known and the direct bond with adjacent bone developed. The purpose of this study was to evaluate the potential of clinical application of tooth ash for preservation of alveolar ridge. For this purpose the author performed an experimental implantation of the particulate and root form of both pure dense hydroxylapatite and tooth ash in alveolar sockets immediately after extraction. The pure dense hydroxylapatite was particulate form and root form made by Calciteck Inc. The tooth ash was prepared by incineration at $950^{\circ}C$, and the syrindrical form of the tooth ash was sintered and trimmed to fit the size of the each extraction socket of 10 mongrel dogs. After sugery the clinical, roentgenographical, and histological observation was carried out. The results obtained were as follows; 1. Clinical observation disclosed no dehiscence and exfoliation due to tissue rejection. 2. Vertical resorption of alveolar bone occurred in all experimental sockets as well as the control sites on the roentgenograph. 3. Osteoclastic activity appeared at the inner surfaces of the crestal alveolar bone on the 1st week but disappeared on the 2nd week. 4. There were macrophages in the particulate form on the 1st and 2nd week after surgery but no macrophages appered in the root form. S. New bone formation was developed from the bony wall of experimental sockets and grew to bond with the implant materials. In particulate form the new bone formation did not occur in central zone independently. 6. Tooth ash implant sites were covered with the newly formed bony trabeculation from third week, but Calcitite particles were covered with soft tissue. 7. Generally the healing occurred more rapidly in control sites than in implant sites.

  • PDF