• 제목/요약/키워드: Pump tower

검색결과 36건 처리시간 0.026초

석유정제산업에서의 유기성 유해대기오염물질의 비산배출량 산정 (Estimation of Fugitive Emission of Organic Hazardous Air Pollutants from Oil Refinery Industry)

  • 양성봉;유미선;이영준;유은진;최성헌
    • 한국대기환경학회지
    • /
    • 제24권2호
    • /
    • pp.229-237
    • /
    • 2008
  • Hazardous air pollutants emitted from the oil refinery plant were surveyed from 1993 US and 2005 Korean TRI data. Toluene, xylene, methanol, MTBE and n-hexane, relatively large in amount of fugitive emission, are considered as candidates of newly designated HAPs in Korea. The sealed oil pump, one of equipments among fugitive sources in the crude oil distillation tower was examined for the estimation of amounts of annual HAPs emissions according to several calculation methods using registered emission factors. Emission rates showed to be decreased with following calculation factors; average emission factor>pegged emission factor>concentration emission factor>correlation equation. Annual emission amounts of benzene, toluene, xylene. ethyl benzene and nhexane from the distillation tower were estimated and amounts of these HAPs calculated with TVOC concentrations obtained from LDAR program and correlation equations showed only 6% of those from using concentration factors.

버즈 두바이 콘크리트 건물의 설계와 시공 (Design and Construction of the Burj Dubai Concrete Building Project)

  • Abdelrazaq, Ahmad
    • 콘크리트학회지
    • /
    • 제20권6호
    • /
    • pp.28-35
    • /
    • 2008
  • 700미터 이상의 높이와 160층 이상으로 설계된 버즈두바이가 완공되면 버즈두바이는 인간이 건축한 건축물 중에서 최고높이의 건축물이 될 것이다. 바람의 동적효과를 완화하고 제어시키는 것이 가장 중요한 설계요소중의 하나이며, 설계초기의 공기역학적 형상과 풍공학에 대한 고려가 이러한 주상복합건물의 건축적 형상 및 디자인에 있어 큰 역할을 하는 반면, 건물의 구조시스템을 위한 재료 선택 또한 디자인의 중요한 요소이고 그 다음으로 세부적인 재료기술에 대한 평가 및 기술자 수급이 요구되어진다. 콘크리트는 콘크리트의 강도, 강성, 감쇠, 잉여력, 형틀성, 내화성, 시공성, 원가 등을 고려하여 선정된다. 이 논문은 콘크리트를 활용한 구조시스템을 적용하면서의 설계적으로 도전되었던 부분과 버즈두바이의 콘크리트공사의 초기계획에 대해 집중적으로 다룰 것이다.

흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구 (A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions)

  • 박찬우;조현철;강용태
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.

저속 고토크 가혹감속기의 저비용 테스트 시스템 개발에 관한 연구 (A Study on the Low Cost Testing System Development of the Low Speed and High Torque Harsh Reducer)

  • 박태현
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.379-386
    • /
    • 2022
  • The goal of this research is to verify a performance test system for a low speed, high torque, and harsh reducer at low cost. The reducer rotates a cooling fan with a diameter of 10 meters, in a high temperature (50℃) cooling tower in a geothermal power plant. It requires about 500 kgf·m torque and 47.75 kW power to rotate the fan at a maximum power condition. An expensive dynamometer is commonly used for performance test of a motor or a reducer. In this paper, a low cost system is developed using a hydraulic pump as a load unit to generate torque instead of a dynamometer. We accurately calculated the required power, the flow meter, and the pressure of the pump, and selected to design and optimize the system at minimal cost. The system also applied another reverse reducer and a gearbox to increase the rotational speed and to reduce the torque from the low speed and high torque target reducer. This allows low-cost systems to be built using inexpensive components. The developed system was able to successfully measure the high torque and the low rotational speed of the target reducer at high temperature.

사무용건물에서 지열히트펌프냉난방시스템의 운전성능 평가 (Performance for Geothermal Heating & Cooling System by Heatpump in Office Building)

  • 안형준;백성권;조정식;손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권1호
    • /
    • pp.23-29
    • /
    • 2007
  • For the perfomance test of geothermal system, a large pilot of capacity of 50RT is built and operated in office building. This system is planed hybrid system with cooling tower as asisstance heat sink. From October, 2004 to September, 2005, this system is operated andmonitored. As the result, COP of heating periods is about 3.46 and COP of cooling periods is about 4.1. Therefore, geothermal system is useful and suitable in Korea.

  • PDF

무다짐 콘크리트를 이용한 높은 40m CFT 기둥의 시공 (Practical Use of Self Compacting Concrete to be filled inside the Steel Tube Columns)

  • 김규동;김한준;손유신;이승훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.1023-1028
    • /
    • 2003
  • The structure of Tower Palace III Sports Center building was designed as concrete Filled Steel Tube(CFT) Column and the filled-in concrete was designed as high compressive strength of 500kgf/$m_2$. The self compacting concrete(SCC, non-vibrating concrete) with 65$\pm$5cm flow must be applied to this case for filling the CFT by injecting the concrete from the column bottom. Laboratory tests and pilot productions of batcher plant were performed for optimum mix design and the full scale Mock-Up test was performed to check the appicability of the construction method. As a result, we observed that good quality SCC and the pressure change of concrete pump normally used domestically. Based on these results, we have constructed 20-40m height CFT columns successfully.

  • PDF

공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 -)

  • 정광섭;김민수;김용찬;박경근;박병윤;조금남
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

중앙냉방시스템의 최적제어에 관한 연구 (Optimal Control for Central Cooling Systems)

  • 안병천
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.354-362
    • /
    • 2000
  • Optimal supervisory control strategy for the set points of controlled variables in the central cooling system has been studied by computer simulation. A quadratic linear regression equation for predicting the total cooling system power in terms of the controlled and uncontrolled variables was developed using simulated data collected under different values of controlled and uncontrolled variables. The optimal set temperatures such as supply air temperature, chilled water temperature, and condenser water temperature, are determined such that energy consumption is minimized as uncontrolled variables, load, ambient wet bulb temperature, and sensible heat ratio, are changed. The chilled water loop pump and cooling tower fan speeds are controlled by the PID controller such that the supply air and condenser water set temperatures reach the set points designated by the optimal supervisory controller. The influences of the controlled variables on the total system and component power consumption was determined. It is possible to minimize total energy consumption by selecting the optimal set temperatures through the trade-off among the component powers. The total system power is minimized at lower supply, higher chilled water, and lower condenser water set temperature conditions.

  • PDF

PIV에 의한 선박 슬로싱 유동 측정해석 (Measurements on a Ship's Sloshing Flows by PIV)

  • 도덕희;조용범;편용범;백태실;권순홍;이정한;황윤식;류민철
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.119-122
    • /
    • 2007
  • The sloshing flows in the cargo tank model of a ship are measured by PIV and are analyzed with the results. The measurement system is consisted of a Nd-Yag laser(120mJ, 15Hz). two cameras($1k\;{\times}\;1k$) and a host computer. Four experimental cases were tested for the tank model. in which swaying motions are made by 6 DOF-motion platform. The amplitudes of swaying are 9.76mm and 29.29mm, and the frequencies are 0.633Hz and 0.828Hz. The measurement regions are the vertical plane 50mm away from the front wall of the tank where a pump tower is installed. It was verified that the flow patterns of the sloshing are similar each other when the swaying amplitudes are similar.

  • PDF

구형 LNG운반선의 탱크지지 구조인 스커트의 좌굴강도에 대한 연구 (A Study on the Buckling Strength of the Skirt Structure in the Spherical LNG Carriers)

  • 김을년
    • 대한조선학회논문집
    • /
    • 제54권5호
    • /
    • pp.393-405
    • /
    • 2017
  • This paper deals with the buckling strength of the skirt structure in the spherical LNG carriers. The spherical cargo tank systems consist of spherical tank, skirt, tank cover, pump tower, etc. The skirt supports the spherical cargo tank and is connected with ship hull structure. It is designed to act as a thermal brake between the tank and the hull structure by reducing the thermal conduction from the tank to the supporting structure. It is built up of three parts, upper aluminum part, middle stainless steel part and lower carbon steel part. The 150K spherical LNG carrier was designed and carried out the strength verification under Classification Societies Rule. The design loads due to acceleration, thermal distribution, self-weight and cargo weight were estimated considering requirements of the Class Rule and numerical simulation analyses. Based on the obtained design loads and experienced project data, the initial structure scantling was carried out. To verify the structural integrity, theoretical and numerical analyses were carried out and strength was evaluated aspect of buckling capacity. The results by LR and DNV design code are shown and discussed.