• Title/Summary/Keyword: Pump system

Search Result 2,876, Processing Time 0.043 seconds

Reliability Analysis on Firewater Supply Facilities based on the Probability Theory with Considering Common Cause Failures (소방수 공급설비에 대한 공통원인고장을 고려한 확률론적 신뢰도 분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.76-85
    • /
    • 2003
  • In this study, we write down the definitions, their causes and the techniques of analysis as a theoretical consideration of common cause failures, and investigate the limitation and the importance of the common cause failures by applying to the analysis on the fire protection as a representative safety facility. As you can know in the reliability analysis, most impressive cause is the malfunctions of pumping operations; especially the common cause failure of two pumps is dominant. In other words, it is possible to assess system-reliability as twice as actual without CCF From these, CCF is extraordinarily important and the results are highly dependent on the CCF factor. And although it would increase with multiple installations, the reliability are not defined as linear with those multiplications. In addition, the differences in results due to the models for analysis are not significant, whereas the various sources of data produce highly different results. Therefore, we conclude that the reliabilities are dependent on the quality of the usable data much better than the variety of models. As a result, the basic and engineering device for the preventions of CCF of the multiple facilities is to design it as reliably as to design the fire-water pump. That is to say, we must assess those reliabilities using PFD whether they are appropriate to SIL (Safety Integrity Level) which is required for the reliability in SIS (Safety Instrumented System). The result of the analysis on the reliability of the fire-water supply with CCF shows that PFD is 3.80E-3, so that it cannot be said to be designed as safely as in the level of SIL5. However, without CCF, PFD is 1.82E-3 which means that they are designed as unsafely as before.

Noncondensable gas's influence in waster vapor absorption accompanying interfacial disturbance into aqueous solution of LiBr

  • Dong-Ho RIE;Keun-Oh Lee
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.2
    • /
    • pp.63-70
    • /
    • 1992
  • The aim of this research is to obtain a basic quantitative understanding of the effect of a noncondensable gas on the absorption of water vapor by a $H_2O$ / LiBr combination with n-octanol as the surfactant. Nonflowing aqueous solutions of LiBr (40,45,50 mass%) were exposed to saturated water vapor following the addition of an n-octanol sufactant (0.01 and 0.6 mass%). A small amount of a noncondensable gas (air) was allowed into the absorber (0.03 volume%) and its effect was analyzed by measuring the amount of water vapor absorbed. This study will aid to predict the performance of heat pump and safety operating condition when the noncondensable gas is not allowed in the absorber The results indicate that, in the presence of small amounts of a noncondensable gas, vapor absorption enhancement ratios are less than half o( those obtained under the same experimental conditions when a noncondensable gas is not present (1). The presence of a noncondensable gas causes the partial vapor pressure of air to increase at the vapor / liquid interface, which results in an instability of vapor absorption rate nd. hence, in an inhibition of interfacial disturbance.

  • PDF

Groundwater Flow Analysis in Fractured Rocks Using Zonal Pumping Tests and Water Quality Logs (구간양수시험과 수질검층자료에 의한 균열암반내 지하수 유동 분석)

  • Hamm, Se-Yeong;Sung, Ig-Hwan;Lee, Byeong-Dae;Jang, Seong;Cheong, Jae-Yeol;Lee, Jeong-Hwan
    • The Journal of Engineering Geology
    • /
    • v.16 no.4 s.50
    • /
    • pp.411-427
    • /
    • 2006
  • This study aimed to recognize characteristics of groundwater flow in fractured bedrocks based on zonal pump-ing tests, slug tests, water quality logs and borehole TV camera logs conducted on two boreholes (NJ-11 and SJ-8) in the city of Naju. Especially, the zonal pumping tests using sin91e Packer were executed to reveal groundwater flow characteristics in the fractured bedrocks with depth. On borehole NJ-11, the zonal pumping tests resulted in a flow dimension of 1.6 with a packer depth of 56.9 meters. It also resulted in lower flow dimensions as moving to shallower packer depths, reaching a flow dimension of 1 at a 24 meter packer depth. This fact indicates that uniform permissive fractures take place in deeper zones at the borehole. On borehole SJ-8, a flow dimension of 1.7 was determined at the deepest packer level (50 m). Next, a dimension of 1.8 was obtained at 32 meters of packer depth, and lastly a dimension of 1.4 at 19 meters of packer depth. The variation of flow dimension with different packer depths is interpreted by the variability of permissive fractures with depth. Zonal pumping tests led to the utilization of the Moench (1984) dual-porosity model because hydraulic characteristics in the test holes were most suitable to the fractured bedrocks. Water quality logs displayed a tendency to increase geothermal temperature, to increase pH and to decrease dissolved oxygen. In addition, there was an increasing tendency towards electrical conductance and a decreasing tendency towards dissolved oxygen at most fracture zones.

Effects of Priming Progesterone on the LH Surge Expressions in Ovariectomized Shiba Goats (LH surge 발현에 대한 서로 다른 Progesterone 농도의 효과)

  • Kim, Seung-Joon
    • Journal of Veterinary Clinics
    • /
    • v.31 no.1
    • /
    • pp.25-30
    • /
    • 2014
  • This study tested the hypothesis that the priming effects of progesterone on the timing of the LH surge induced by exogenous estradiol are more potentiated the negative feedback actions of progesterone on LH secretion by the existence of estradiol. In previous studies, the time interval from estradiol infusion until the peak of LH surge was gradually and significantly extended by the different levels of progesterone treated before estradiol infusions. Longterm ovariectomized Shiba goats that had received implants of estradiol capsules (Day 0) and three different progesterone silastic packet inducing follicular, subluteal and luteal levels of progesterone were divided into three groups such as non-P, low-P and high-P group. Blood samples were collected daily throughout the experiment for the analysis of gonadal steroid hormone levels. On Day 7, all devices of progesterone and estradiol packets were removed but estradiol capsules were maintained during the experiment, and blood samples were collected at 1 hr interval for 12 h from the time of progesterone removals to determine peripheral changes of estradiol and progesterone concentration. Then all animals were infused estradiol on the Day 7 after 13 h from the removals of progesterone devices with a peristaltic pump into jugular vein at a rate of 3-6 ${\mu}g/h$ for 36 h. For analysis of peripheral LH and estradiol concentration, blood samples were collected via another jugular vein at 2 h intervals for 52 h (from 4 h before the start of estradiol infusion to 48 h after the start of estradiol infusion). In all animals of the three groups treated with estradiol infusion, an LH surge was expressed but the peak time of LH surge was different. This time interval was not extended by the different levels of progesterone treated before estradiol infusions and the difference was not significant during this interval between the Low P and the High P groups. Progesterone pretreatment may contribute to regulating the neural system that is responded by estradiol, and estradiol existence potentiates the negative feedback effect of progesterone on GnRH/LH surge-generating system.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

Performance Improvement of Dielectric Barrier Plasma Reactor for Advanced Oxidation Process (고급산화공정용 유전체 장벽 플라즈마 반응기의 성능 개선)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.459-466
    • /
    • 2012
  • In order to improved treatment performance of dielectric barrier discharge (DBD) plasma, plasm + UV process and gas-liquid mixing method has been investigated. This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical). The basic DBD plasma reactor of this study consisted of a plasma reactor (consist of quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode), air and power supply system. Improvement of plasma reactor was done by the combined basic plasma reactor with the UV process, adapt of gas-liquid mixer. The effect of UV power of plasma + UV process (0~10 W), gas-liquid mixing existence and type of mixer, air flow rate (1~6 L/min), range of diffuser pore size (16~$160{\mu}m$), water circulation rate (2.8~9.4 L/min) and UV power of improved plasma + UV process (0~10 W) were evaluated. The experimental results showed that RNO degradation of optimum plasma + UV process was 7.36% higher than that of the basic plasma reactor. It was observed that the RNO decomposition of gas-liquid mixing method was higher than that of the plasma + UV process. Performance for RNO degradation with gas-liquid mixing method lie in: gas-liquid mixing type > pump type > basic reactor. RNO degradation of improved reactor which is adapted gas-liquid mixer of diffuser type showed increase of 17.42% removal efficiency. The optimum air flow rate, range of diffuser pore size and water circulation rate for the RNO degradation at improved reactor system were 4 L/min, 40~$100{\mu}m$ and 6.9 L/min, respectively. Synergistic effect of gas-liquid mixing plasma + UV process was found to be insignificant.

Dry etching of polycarbonate using O2/SF6, O2/N2 and O2/CH4 plasmas (O2/SF6, O2/N2와 O2/CH4 플라즈마를 이용한 폴리카보네이트 건식 식각)

  • Joo, Y.W.;Park, Y.H.;Noh, H.S.;Kim, J.K.;Lee, S.H.;Cho, G.S.;Song, H.J.;Jeon, M.H.;Lee, J.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.1
    • /
    • pp.16-22
    • /
    • 2008
  • We studied plasma etching of polycarbonate in $O_2/SF_6$, $O_2/N_2$ and $O_2/CH_4$. A capacitively coupled plasma system was employed for the research. For patterning, we used a photolithography method with UV exposure after coating a photoresist on the polycarbonate. Main variables in the experiment were the mixing ratio of $O_2$ and other gases, and RF chuck power. Especially, we used only a mechanical pump for in order to operate the system. The chamber pressure was fixed at 100 mTorr. All of surface profilometry, atomic force microscopy and scanning electron microscopy were used for characterization of the etched polycarbonate samples. According to the results, $O_2/SF_6$ plasmas gave the higher etch rate of the polycarbonate than pure $O_2$ and $SF_6$ plasmas. For example, with maintaining 100W RF chuck power and 100 mTorr chamber pressure, 20 sccm $O_2$ plasma provided about $0.4{\mu}m$/min of polycarbonate etch rate and 20 sccm $SF_6$ produced only $0.2{\mu}m$/min. However, the mixed plasma of 60 % $O_2$ and 40 % $SF_6$ gas flow rate generated about $0.56{\mu}m$ with even low -DC bias induced compared to that of $O_2$. More addition of $SF_6$ to the mixture reduced etch of polycarbonate. The surface roughness of etched polycarbonate was roughed about 3 times worse measured by atomic force microscopy. However examination with scanning electron microscopy indicated that the surface was comparable to that of photoresist. Increase of RF chuck power raised -DC bias on the chuck and etch rate of polycarbonate almost linearly. The etch selectivity of polycarbonate to photoresist was about 1:1. The meaning of these results was that the simple capacitively coupled plasma system can be used to make a microstructure on polymer with $O_2/SF_6$ plasmas. This result can be applied to plasma processing of other polymers.

Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse (단동온실 내 공기순환팬 사용에 따른 온습도 및 에너지소비량 비교 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Kim, Hyung Kweon;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.276-282
    • /
    • 2017
  • The aim of this study was to compare and analyze air temperature and humidity distribution and energy consumptions according to using air circulation fans in single-span greenhouses. The greenhouses located in Cheongnam-myeon, Cheongyang-gun, Chungcheongnam-do, Korea. There were cherry tomatoes in the greenhouses and the size of greenhouses was as follows;ridge height : 3.2 m, wide : 6 m, length : 95 m. The heating system was composed of a hot-water boiler and 6 FCUs(Fan Coil Unit)-4 FCUs were on bottom with duct and 2 FCUs were installed at 2.0 m. A total of 18 air circulation fans(impeller's diameter : 230 mm) were bilaterally arranged in 2 rows in the experimental greenhouse. The sensors for measuring air temperature and humidity were located at a quarter and three quarters of a length. The height of sensors were 0.8 m, 1.8 m. To calculate energy consumption in greenhouses, water temperature at inlet and outlet in a water pump, volume of water were measured. Form February 3rd to March 23th, temperature, humidity and energy consumptions were measured during heating time(6pm~7am). In a greenhouse without fans, the average differences of temperature and humidity were $0.75^{\circ}C$, 2.31%, respectively. The operation of fans showed their differences to $0.42^{\circ}C$, 1.8%. The standard deviation of temperature and humidity between measuring points in the greenhouse with fans was lower than the greenhouse without fans. Total energy consumptions in a greenhouse without fans were 4,673 kWh. In the greenhouse with fans, the total energy consumptions were 4,009 kWh. The energy consumptions in a greenhouse with fans 14.2% were less than the greenhouse without fans. Therefore, air circulation makes temperature and humidity uniform and saves energy consumptions for heating.

Development of a 2-fluid Jet Mixer for Preventing the Sedimentation in Livestock Liquid Manure Storage Tank (가축분뇨액비저장조 침전물 퇴적 방지를 위한 2류체 제트노즐식 교반장치 개발에 관한 연구)

  • Yu, B.K.;Hong, J.T.;Kim, H.J.;Kweon, J.K.;Oh, K.Y.;Park, B.K.
    • Journal of Animal Environmental Science
    • /
    • v.18 no.3
    • /
    • pp.207-220
    • /
    • 2012
  • There are around 7,500 manure tanks to treat the manures from pigs in Korea. In the tank, there are too much sediments deposited on the base and wall, which causes low efficiency of stock capacity and manure fermentation. In order to minimize sediments and to ferment manure effectively, we developed a 2-fluid jet mixer for mixing sediments in liquid livestock manure tank. For developing the prototype, we tested a factorial experimental system with various nozzles, and simulated CFD models with two kinds of nozzle arrangement. From the results of factorial experiment and CFD simulation, we concluded the dia. ratio of primary : secondary nozzle should be 1:2 and the nozzles should be arranged at the same distances toward to the circumferential direction. With this results, we manufactured a 2-fluid jet mixer which is consists of four 2-phase nozzles, centrifugal slurry pump and root's type air blower. And, we carried out the performance test of the prototype in the round shaped liquid manure tank in the farm. The performance test results showed that the uniformity of TS (Total Solid) and VS (Volatile Solid) was raised from 21.3 g/L, 13.3 g/L In steady state to TS and VS to 23.0 g/L, 14.1 g/L in the mixing operation. Therefore, we could conclude that the prototype of 2-fluid mixer could make the solid material which could be sediments in the tank not to be deposited in the tank and to be contacted to air bubbles which could enhance the efficiency of the fermentation of livestock manure.

Research on Improvement of Lake Water Quality Using Artificial Floating Island (호소 수질 개선을 위한 인공식물섬 장치 개발 연구)

  • Kim, Tae-Hoon;Ahn, Tae-Woong;Jung, Jae-Hoon;Choi, I-Song;Oh, Jong-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.263-270
    • /
    • 2010
  • This is a research on development of water purification equipment called artificial floating island (=AFI) for the stagnant water area which can secure exuberant landscape and water-friendility. The equipment devised in this study is designed to make up the weakness of conventional AFIs and improves the removal efficiency of pollutants using the mixture of media and plants. The air compressor positioned at the inlet releases air with inflow continuously, the water pump at the outlet sprays as a form of fountain with causing a disturbance on stable water column, then, both of them contribute improvement of water quality over a large area. We applied Bio-stone as a media in this system and performed an experiment of pre-efficiency test, and we concluded that the higher pollutants concentration of inflow, the higher removal efficiency we obtained. At the result of lab-scale experiment, in the case of high-concentration inflow, in the removal efficiency of SS is 62.2%, BOD is 50.2%, COD is 55.1%, T-N is 31.6%, T-P is 38.4%. In addition, to evaluate the field application, we set up the facilities in Sin-gal lake located in Yongin-Si Gyeonggi-Do, and researched on the removal efficiency of outflow relative to the inflow. As a result, SS is 53.5%, BOD is 32.8%, COD is 36.9%, T-N is 22.6%, T-N is 33.2%.