• Title/Summary/Keyword: Pump performance

Search Result 1,915, Processing Time 0.026 seconds

Energy Performance Evaluation of Low Energy Houses using Metering Data (실측데이터를 이용한 저에너지주택의 에너지성능평가)

  • Baek, Namchoon;Kim, Sungbum;Oh, Byungchil;Yoon, Jongho;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.369-374
    • /
    • 2015
  • This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).

Design and Construction of a Bottoming Organic Rankine Cycle System for an Natural Gas Engine (가스엔진용 유기랭킨사이클의 설계 및 제작)

  • Lee, Minseog;Baek, Seungdong;Sung, Taehong;Kim, Hyun Dong;Chae, Jung Min;Cho, Young Ah;Kim, Hyoungtae;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.65-72
    • /
    • 2016
  • ORC system was designed and constructed for utilizing the heat of the exhaust gas and coolant released from the gas engine which was modified to use natural gas as a fuel. In this paper the components of the ORC system were designed and manufactured based on measured data of the gas engine. The components are composed of two plate heat exchanger, the 5kW-class expander and multi stage centrifugal pump. The thermodynamic performance of the ORC system was analyzed by using the electric heater. Also, the developed ORC system was implemented to modified natural gas engine. Two gas engines were used to supply heat to the ORC system. As a result of test bench, when the heat source temperature is $110^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 5.22kW, 7.41, 9.09%. As a result of field test, when the heat source temperature is $86^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 2kW, 3.75, 6.45%.

Study on effect of fuel property change on vehicle important parts and exhaust gas (연료 물성 변화가 자동차 주요부품 및 배출가스에 미치는 영향 연구)

  • Lee, Jung-Cheon;Kim, Sung-Woo;Lee, Min-Ho;Kim, Ki-Ho;Park, An-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.866-873
    • /
    • 2017
  • Exhaust regulations of automobile are being reinforced increasingly as environmental problems issues came to the fore by industrial development. However, it is known that the exhaust emission is not only influenced by the system of automobile but also the fuel properties. In particular, high-performance engines have required high-performance fuels with high lubricity as CRDI engines(diesel engine) have been developed and commercialized. This paper have examined that the fuel property variations affect a major parts and an exhaust gas of automobile. It was confirmed that the high pressure pump, the injector and the DPF(diesel particulate filter) were damaged and fuel efficiency was get worse due to use the fuel of lacking lubricity property($651{\mu}m$/quality standard: less in $400{\mu}m$). In addition, through an iron component was detected in the broken DPF, it was estimated that the breakage of the DPF was caused by the excessive exhaust of the particulate matter due to the iron component of the fuel.

Development Status of Technology Demonstration Model for Staged Combustion Cycle Engine (다단연소사이클 엔진 기술검증시제 개발 현황)

  • Kim, Chaehyoung;Lee, Jungho;Woo, Seongphil;So, Younseok;Yi, SeungJae;Lee, Kwang-Jin;Cho, Namkyung;Han, Yeoungmin;Kim, Jin-han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.4
    • /
    • pp.104-111
    • /
    • 2019
  • Staged combustion cycle engines exhibit higher combustion performance compared with open cycle engines with a gas generator. An advanced research of the staged combustion cycle engine is going on for the next program following the KSLV-II program. Various experiments have been carried out for the technology demonstration model, TDM0A and TDM0B. The experiments on the combustion performance are aimed to understand the engine start condition and combustion characteristics. They also aim to develop the oxidizer-rich pre-burner and the combustor of the staged combustion cycle engine. The engine-shaped model, TDM1A is fabricated based on the experimental data. The combustion experiment of the TDM1A shows that the combustion pressure of the combustor is approximately 91 bar and the turbine rotation is approximately 28,00 rpm. The result is stable and satisfies the development requirements. The present paper reports on the development process and characteristics of engine models from TDM0A to TDM1A.

Fundamental study on sound absorption of a dental hand piece using micro-porous EPP substrate processed by UV laser (UV 레이저응용 마이크로 다공성 EPP 기판의 치과용 핸드피스 흡음성능에 관한 기초연구)

  • You, Dong-Bin;Shin, Myung-Ho;Byun, Hyo-Jin;Choi, Do-Jung;Sung, Kuo-Won;Ma, Yong-Won;Shin, Bo-Sung
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.5
    • /
    • pp.158-164
    • /
    • 2019
  • Recently many studies to reduce the noise of dental hand piece which generate inevitably mechanical sound to offend to the ear of a patient have been spotlighted. Generally, methods of adding a sound absorbing material inside the exhaust valve, air pump of machine or automobile are widely reported as optimal way to reduce the mechanical noise. In this paper we studied a new UV laser aided manufacturing of micro-porous structure of EPP substrate and applied dental hand piece to improve the efficiency of sound absorption. A lot of micro-sized pores were fabricated with UV laser processing on the surface of sliced EPP substrate. From fundamental experiments, more high-performance of micro-porous EPP substrate has finally demonstrated for sound-absorbing structure of the micro muffler inside dental hand piece, which actually has the excellent potential to apply a lot of potable machine.

Determination of proper ground motion prediction equation for reasonable evaluation of the seismic reliability in the water supply systems (상수도 시스템 지진 신뢰성의 합리적 평가를 위한 적정 지반운동예측식 결정)

  • Choi, Jeongwook;Kang, Doosun;Jung, Donghwi;Lee, Chanwook;Yoo, Do Guen;Jo, Seong-Bae
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.9
    • /
    • pp.661-670
    • /
    • 2020
  • The water supply system has a wider installation range and various components of it than other infrastructure, making it difficult to secure stability against earthquakes. Therefore, it is necessary to develop methods for evaluating the seismic performance of water supply systems. Ground Motion Prediction Equation (GMPE) is used to evaluate the seismic performance (e.g, failure probability) for water supply facilities such as pump, water tank, and pipes. GMPE is calculated considering the independent variables such as the magnitude of the earthquake and the ground motion such as PGV (Peak Ground Velocity) and PGA (Peak Ground Acceleration). Since the large magnitude earthquake data has not accumulated much to date in Korea, this study tried to select a suitable GMPE for the domestic earthquake simulation by using the earthquake data measured in Korea. To this end, GMPE formula is calculated based on the existing domestic earthquake and presented the results. In the future, it is expected that the evaluation will be more appropriate if the determined GMPE is used when evaluating the seismic performance of domestic waterworks. Appropriate GMPE can be directly used to evaluate hydraulic seismic performance of water supply networks. In other words, it is possible to quantify the damage rate of a pipeline during an earthquake through linkage with the pipe failure probability model, and it is possible to derive more reasonable results when estimating the water outage or low-pressure area due to pipe damages. Finally, the quantifying result of the seismic performance can be used as a design criteria for preparing an optimal restoration plan and proactive seismic design of pipe networks to minimize the damage in the event of an earthquake.

Comparison of Passive Diffusional Organic Vapor Samplers with Charcoal Tubes for the Measurement of Mixed Organic Solvents (확산형 포집기와 활성탄관을 이용한 공기중 혼합 유기용제 측정에 관한 연구)

  • Ahn, Kyu-Dong;Yeon, You-Yong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.127-136
    • /
    • 1994
  • Diffusional sampling devices offer many advantages for measuring concentration levels of industrial contaminants than the conventional pump and charcoal tubes because they are lightweight, require no power, pump or tubing. This study designed to evaluate and compare the sampling performance of passive sampler to charcoal tube from mixed organic solvent workplace with 181 organic solvent using workers working in different concentration of organic solvents. All study workers kept both devices in their breathing zone simultaneuosly in the workplaces, and the sampling analytical results were compared with those of charcoal tube. The results obtained are as follows: 1. The concentrations of toluene and xylene measured by passive sampler were slightly higher than those of charcoal tube, but there were no significant statistical differences between two methods. 2. The concentrations of MEK and cyclo-hexanone measured by passive sampler in low exposure workplace (below 0.20 of MEK TLV levels and 0.1 of cyclo-hexanone TLV levels) were about 2 times higher than that of charcoal tube sampling. While, absorption efficiency of passive sampler was reduced according to increasing concentration measurements of MEK and cyclo-hexanone in air. 3. The ratios of concentrations of toluene, xylene, MEK and cyc1o-hexanone measured by passive sampler over those measured by charcoal tube were 1.11, 1.07, 1.63 and 3.65 respectively. 4. The percentages of concentration of passive samplers within 0.75 and 1.25 of charcoal tube value as a reference value of 1.0 were 57% in toluene, 74% in xylene, 34% in MEK and 32% in cyclo-hexanone respectively. 5. The correlation coefficients of toluene, xylene, MEK and cyclo-hexanone between passive sampler and charcoal tube sampler were 0.963, 0.957, 0.943 and 0.562 with statistical significance.

  • PDF

Conceptual framework for Emotions in Usability of Products (제품 사용성과 감성에 관한 개념적 연구)

  • Lee Kun-Pyo;Jeong Sang-Hoon
    • Science of Emotion and Sensibility
    • /
    • v.8 no.1
    • /
    • pp.17-28
    • /
    • 2005
  • With the advent of computer technology, the fundamental nature of products has shaped from physical forms towards product interactivity, The focus is now on usability of the product with ease and efficiency rather than conversing with just the looks of the product. However, most definitions of usability and contemporary usability-related researches, have focused on the performance-oriented functional aspects of usability (i.e., how well users perform tasks using a product). Today, user expectations are higher; products that bring not only functional benefits but also emotional satisfaction. So far, there have been many studies on human emotions and the emotional side of products in the field of emotional engineering. Contemporary emotion-related researches have focused mainly on the relationship between product aesthetics and the emotional responses elicited by the products, but little is known about emotions elicited from using the products. The main objective of our research is analyzing user's emotional changes while using a product, to reveal the influence of usability on human emotions. In this research, we suggested conceptual framework for the study on the relationship between usability of products, and human emotions with emphasis on mobile phones. We also extracted emotional words for measuring user's emotions expressed not from looking at the product's appearance, but from using the product. First, we assembled a set of emotions that is sufficiently extensive to represent a general overview of the full repertoire of Korean emotions from the literature study. Secondly, we found emotional words in the after note by the users on the websites. Finally, verbal protocols in which the user says out loud what he/she ks feeling while he/she ks carrying out a task were collected. And then, the appropriateness of extracted emotional words was verified by the members of the consumer panel of a company through web survey. It is expected that emotional words extracted in this research will be used to measure user's emotional changes while using a product. Based on the conceptual framework suggested in this research, basic guidelines on interface design methods that reflect user's emotions will be illustrated.

  • PDF

Clinical Effects of an Improved Pump Reaction Rate and Automatic Occlusion Sensing System in Phacoemulsification (수정체유화장치의 초음파 출력속도 및 자동막힘감지 기능 향상의 술 후 임상결과 비교)

  • Kim, You Na;Lee, Jin Ah;Kim, Jae Yong;Kim, Myoung Joon;Tchah, Hung Won
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1017-1023
    • /
    • 2018
  • Purpose: A recently introduced phacoemulsification system, the WhiteStar $Signature^{(R)}$ PRO, has demonstrated improved nucleus followability and cutting efficiency via an improved pump regulator with a higher reaction response and an automatic occlusion sensing system. In this study, we compared various phacoemulsification parameters between the new system and an older version of the device. Methods: A total of 80 eyes of 68 patients with cataracts who had undergone phacoemulsification by a single surgeon were included in this study. Forty eyes of patients underwent phacoemulsification using the older $Signature^{(R)}$ system (WhiteStar); these patients were classified as the control group. Another 40 eyes of patients underwent phacoemulsification with the newer enhanced system, the WhiteStar $Signature^{(R)}$ PRO; these patients were assigned to the experimental group. During the operation, operative parameters, including the effective phaco time (parameter of effective phaco time with a specific coefficient for the transversal movement expressed in seconds, EFX), ultrasound time (seconds [s]), effective phacoemulsification time (EPT, s), average phacoemulsification power (AVG, %), and balanced salt solution usage, were measured to determine the performance enhancement offered by the updated system. Central corneal thickness was measured before and after surgery to compare corneal edema. The relationships between the two groups were analyzed using an independent t-test. Results: The Signature $PRO^{(R)}$ system showed a lower EFX (p < 0.001), a shorter EPT (p < 0.001), and a smaller AVG (p < 0.001). Postoperative corneal thickness did not differ significantly between the two groups. Conclusions: Comparing the efficacy of the improved reaction speed of the device and automatic occlusion sensing system in performing phacoemulsification, the updated Signature $PRO^{(R)}$ system demonstrated superior followability and cutting efficiency regardless of nuclear cataract hardness.

A Dual Charge Pump PLL-based Clock Generator with Power Down Schemes for Low Power Systems (저 전력 시스템을 위한 파워다운 구조를 가지는 이중 전하 펌프 PLL 기반 클록 발생기)

  • Ha, Jong-Chan;Hwang, Tae-Jin;Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.11
    • /
    • pp.9-16
    • /
    • 2005
  • This paper proposes a programmable PLL (phase locked loop) based clock generator supporting a wide-range-frequency input and output for high performance and low power SoC with multiple clock frequencies domains. The propose system reduces the locking time and obtains a wide range operation frequency by using a dual-charge pumps scheme. For low power operation of a chip, the locking processing circuits of the proposed PLL doesn't be working in the standby mode but the locking data are retained by the DAC. Also, a tracking ADC is designed for the fast relocking operation after stand-by mode exit. The programmable output frequency selection's circuit are designed for supporting a optimized DFS operation according to job tasks. The proposed PLL-based clock system has a relock time range of $0.85{\mu}sec{\sim}1.3{\mu}sec$($24\~26$cycle) with 2.3V power supply, which is fabricated on $0.35{\mu}m$ CMOS Process. At power-down mode, PLL power saves more than $95\%$ of locking mode. Also, the PLL using programmable divider has a wide locking range ($81MHz\~556MHz$) for various clock domains on a multiple IPs system.