• Title/Summary/Keyword: Pump it up

Search Result 185, Processing Time 0.032 seconds

Media archaeological research on arcade games since the 1990s: Focusing on the rhythm action game (1990년대 이후 아케이드 게임에 대한 미디어 고고학적 연구: 리듬액션게임을 중심으로)

  • Jeon, Eun Ki
    • Journal of Korea Game Society
    • /
    • v.22 no.1
    • /
    • pp.77-86
    • /
    • 2022
  • This article argues that electronic entertainment has continued to this day, contrary to the existing view that it has been absorbed by digital games since the 1990s. From a media archaeological point of view, it tracks in what cultural and technical context the electronic entertainment called "Pump It Up", which has been popular since the late 1990s, has been accepted and used by gamers. The big trend of 'Pump' took place through a "performative shift" of gamers' creative game performing, and the rise and fall of the 'Pump' took place through competitions and interactions between imaginaries and practices that each subject surrounded the game had. In conclusion, it suggests the necessity of media archaeological research on various genres of arcade games.

Understanding Ion Pump Emissions : Classification, Source Identification and Elimination of Emissions from Ion Pumps

  • Wynohrad, Tony
    • Applied Science and Convergence Technology
    • /
    • v.23 no.6
    • /
    • pp.340-344
    • /
    • 2014
  • Ion pumps continue to be a staple in ultra-high vacuum (UHV) applications. Since their adoption as a primary UHV pump in the 1960's, it has been known that a variety of particles can emanate from within the ion pump and cause undesirable effects on current measurements and optics components. Historically the solution has been baffling and shielding which results in longer conductance paths to the ion pump. Those solutions can work, but require a larger pump and more vacuum plumbing to compensate for conductance losses. The first step was to fully understand the nature of the particles and their charges. Once those were characterized options for emissions reduction were evaluated. It was determined that an efficient design of shielding near the source of the particle generation site was the most cost effective solution. With a slight modification to the chamber of a small ion pump, internal shielding was developed that reduced the emissions by a factor of up to 1000 times.

Implementation of Monitoring and Control System for Fire Engine Pump using the AJAX (AJAX를 이용한 소방엔진펌프의 모니터링과 제어 시스템 구현)

  • Yang, Oh;Lee, Heon-Guk
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.3
    • /
    • pp.40-45
    • /
    • 2016
  • In this paper, the fire engine pump is controlled and monitored by the AJAX (Asynchronous Javascript and Xml) in the web server. The embedded system with built-in system having a processor and a memory of high performance occurs many problems in transmitting the large amount of data in real time through the web server. The AJAX is different from HTML (Hyper Text Makeup Language) with java script technology and can make RIA (Rich Internet Application). It process the necessary data by using asynchronous and it take advantage of usefulness, accessibility, a fast response time. Using AJAX can build up web server with real time and monitoring that fire engine pump status, check processing pump memory in the event of fire, also remotely monitors can do. The web server system can control the fire engine pump as like the black box. The experimental results show the effectiveness and commercialize possibility.

A Study on Optimal Operation of Summer Season Cooling System with Numbers of Heat Pumps (다수의 히트펌프로 구성된 냉난방시스템에서 하절기 히트펌프의 최적운전에 관한 연구)

  • Shin, Kwan-Woo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.35-40
    • /
    • 2006
  • Heat-pump system has a special feature that provides heating operation in winter season and cooling operation in summer season with a single system. It also has a merit that absorbs and makes use of wastewater heat, terrestrial heat, and heat energy from the air. Because heat-pump system uses midnight electric power, it decreases power peak load and is very economical as a result. By using the property that energy source is converted to low temperature when losing the heat, high temperature energy source is used to provide heating water and low temperature energy source is used to provide cooling water simultaneously in summer season. This study made up a heat-pump system with 4 air heat sources and a water heat source and implemented the optimal operation algorithm that works with numbers of heat pumps to operate them efficiently. With the heat-pump system, we applied it to cooling and heating operation in summer season operation mode in a real building.

Leakage and Rotordynamic Analysis of High Pressure Floating Ring Seal in Turbo Pump (터보 펌프 고압 후로팅 링 실의 누설량 및 회전체 동역학적 특성 해석)

  • Ha, Tae Woong;Lee, Yong-Bok;Kim, Chang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.3 s.12
    • /
    • pp.29-38
    • /
    • 2001
  • The floating ring seal has the ability of minimizing clearance without the rubbing phenomenon. It is often used in the turbo pump units of liquid rocket engines due to its superior leakage performance. The exact prediction of the lock-up position of the floating ring, the leakage performance, and the rotordynamic coefficients of the seal is necessary to evaluate the rotordynamic performance of the turbo pump unit. The governing equations(which are based on the Bulk-flow Model) we solved by the Fast Fourier Transform method. The lock-up position, leakage flow rate, and rotordynamic coefficients are evaluated according to the geometric parameters of the floating ring seal.

  • PDF

Experimental Study on the Leakage Performance Characteristics of Floating Ring Seal (플로팅 링 실의 누설 특성에 관한 실험적 연구)

  • 안경민;이용복;김창호;하태웅
    • Tribology and Lubricants
    • /
    • v.20 no.4
    • /
    • pp.183-189
    • /
    • 2004
  • The floating ring seal is used in an oxidizer and a fuel pump of the turbo pump unit in the liquid rocket engine to optimize a leakage without rubbing phenomenon. The damper floating ring seal, one of the floating ring seals, is with round hole pattern surfaces. It can reduce the leakage by increased friction factor that obtained from experimental data. In this paper, the leakage test about floating ring seal and damper floating ring seal was conducted. The test result showed the leakage performance of damper floating ring seal was better than the leakage performance of floating ring seal. With the leakage test the lock-up and rotation test about seal was conducted and that position is measured. The relatively large lock-up eccentric ratio was obtained from the test result of damping floating ring seal. The attitude angle of seal increases with increasing of shaft rotation.

Experimental Study on the Leakage Performance Characteristics of floating Ring Seal (플로팅 링 실의 누설 특성에 관한 실험적 연구)

  • 안경민;이용복;김창호;하태웅
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.820-825
    • /
    • 2004
  • The floating ring seal is used in an oxidizer and a fuel pump of the turbo pump unit in the liquid rocket engine to optimize a leakage without rubbing phenomenon. The damper floating ring seal, one of the floating ring seals, is with round hole pattern surfaces. It can reduce the leakage by increased friction factor that obtained from experimental data. In this paper, the leakage test about floating ring seal and damper floating ring seal was conducted. The test result showed the leakage performance of damper floating ring seal was better than the leakage performance of floating ring seal. With the leakage test the lock-up and rotation test about seal was conducted and that position is measured. The relatively large lock-up eccentric ratio was obtained from the test result of damping floating ring seal. The attitude angle of seal increases with increasing of shaft rotation

  • PDF

A Study on Performance Characteristics According to the Fuel Conditions for a Fuel Pump in LPG Engine (자동차용 LPG 펌프의 연료조건에 따른 성능특성에 관한 연구)

  • Park, Cheol-Woong;Kim, Chang-Up;Choi, Kyo-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.4
    • /
    • pp.266-274
    • /
    • 2008
  • The need for more fuel-efficient and lower-emission vehicles has driven the technical development of alternative fuels such as Liquefied Petroleum Gas(LPG) which is able to meet the limits of better emission levels without many modifications to current engine design. LPG has a high vapor pressure and lower viscosity and surface tension than diesel and gasoline fuels. These different fuel characteristics make it difficult to apply it for the conventional gasoline or diesel fuel pump directly. In this study, experiments are performed to get performance and efficiency of the fuel pump at different condition as temperature, rotating speeds, composition of fuel. The characteristics of fuel pump is affected by cavitation due to the variation of temperature and composition.

Prediction of a Leakage in a Liquid Hydrogen Pump Using a Finite Element Method (유한요소 해석을 이용한 액화수소 펌프 누설량 예측)

  • HYUNSE KIM;YOUNG-BOG HAM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.3
    • /
    • pp.292-296
    • /
    • 2023
  • Until recently, ships, automobiles, and drones using hydrogen energy are being actively researched. In addition, stations and facilities for hydrogen supply are being developed widely. Among them, a hydrogen pump is necessary for compressing it and transfer to other stations. The liquid hydrogen pump is operated at very high pressure up to 90 MPa. In our research, a reciprocating plunger pump is studied. Especially, a leakage in a liquid hydrogen pump is predicted using a finite element method. As a result, it was found that leak mass flow rates changed from 0.09 to 2.20 kg/h, when the gaps were given from 2 to 6 ㎛. Thus pump efficiencies were calculated from 99.9 to 97.9%, when the gaps changed from 2 to 6 ㎛. These results are useful for the design of the liquid hydrogen pump.

A Study on the Development of a Infusion Pump based on an Active Muscle Pump (능동형 근육펌프 구조의 수액 주입 펌프 개발에 관한 연구)

  • Lee, Jeong-Whan;Lee, Sang-Yeob;Lee, Jung-Eun;Ahn, Ihn-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.443-449
    • /
    • 2022
  • In this study, in order to improve the disadvantages of the environmental error of the infusion set that performs infusion therapy in the existing clinical practice and to maximize the user's convenience by miniaturizing the existing infusion pump system, the structure of the muscle pump of the human vein was imitated. As a double check valve method, a method for preventing the backflow of fluid and discharging a constant fluid in one direction by external pressure was proposed. The proposed bio-mimic muscle pump uses a check valve that controls the flow of fluid in one direction and a silicone tube with elasticity, and a chamber is constructed. A peristaltic pump for applying intermittent pressure to the tube chamber was constructed using a multi-cam structure roller. In order to verify the performance of the proposed pump, optimization was performed while changing the number of multi-cam rollers and adjusting the speed of the roller driving motor, and the reproducibility of the instantaneous discharge amount and the continuous discharge amount of the pump was compared and tested. The performance of the muscle pump proposed in this study was verified through experiments that it can inject up to 1L of fluid within 12 hours, and that it is possible to inject the fluid with an accuracy of ±0.1ml. Real-time monitoring of the fluid injection volume through the bio-mimic muscle pump proposed in this study not only increases the convenience of the administrator, but also provides a precise fluid administration environment to more patients at a low cost, and additionally applies bubble detection and occlusion detection technology If so, it is believed that a safer medical environment can be provided to patients.