• Title/Summary/Keyword: Pump beam

Search Result 91, Processing Time 0.022 seconds

Random Vibration and Harmonic Response Analyses of Upper Guide Structure Assembly to Flow Induced Loads (유체유발하중을 받는 상부안내구조물의 랜덤진동 및 조화응답해석)

  • 지용관;이영신
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.59-68
    • /
    • 2002
  • The cylindrical Upper Guide Structure assembly of the reactor intervals wish the Core Support Barrel and the Inner Barrel Assembly is subjected to flow induced loads horizontally which include random pressure fluctuation due to turbulent flow and pump pulsation pressures. The purpose of this papers is to perform random vibration and harmonic response analyses fort flow induced loads. The dynamic response characteristics due to random turbulence and pump pulsation loads were evaluated using the lumped mass beam model. Especially the model considered the annulus effects due to water gaps existing between cylindrical structures such as the Upper Guide Structure Barrel, the Core Support Barrel, and the Inner Barrel Assembly. The effect of the Inner Barrel Assembly inside the Upper Guide Structure assembly was studied. The peak dynamic responses lot each loading condition due to the addition of IBA were affected by the natural frequencies of the structures. Therefore the peak dynamic responses of the structures should be conservatively obtained from evaluation of dynamic analysis for various loading conditions.

The Absorption Saturation and Diffraction Efficiency of the Permanent Gratings Due to the Photodarkening in Semiconductor Doped Glasses (반도체가 첨가된 유리의 암색화에 따른 포화흡수 변화와 영구 회절격자의 회절효율 연구)

  • Baek, Sung-Hyun;Shin, Sang-Hoon;Kim, Sang-Cheon;Choi, Moon-Goo;Park, seung-Han;Kim, Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.331-336
    • /
    • 1995
  • The steady-state absorption saturation of the photodarkend SDG was investigated. The absorption saturation intensity was observed to increase for the photodarkened sample. The diffraction efficiency of the permanent grating due to photodarkening was also measured using the backward DFWM technique. For the low backward pump intensity, the diffraction efficiency was proportional to the intensity of the pump beam. The origin of increasing diffraction efficiency is attributed to the difference in absorption between the permanent gratings created by photodarkening. ening.

  • PDF

Output Characteristics of a Pulsed Ti:sapphire Laser Oscillator Pumped Longitudinally by Second Harmonic Wave of Nd:YAG Laser and a Ti:sapphire Laser Amplifier Operated along the Single Path of the Oscillator Beam (Nd:YAG 레이저의 제 2조화파로 종여기하는 펄스형 Ti:sapphire 레이저 발진기와 이를 이용한 단일경로 형태의 Ti:sapphire 증폭기의 출력특성)

  • Kim, Kyung-Nam;Jo, Jae-Heung;Lim, Gwon;Cha, Byung-Heon
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.66-73
    • /
    • 2007
  • The various output characteristics of a pulsed Ti:sapphire laser oscillator with a plane-parallel resonator, pumped longitudinally by the second harmonic wave of a Nd:YAG laser, and the output of a Ti:sapphire laser amplifier operated along the single path of the oscillator beam were investigated and analyzed. In the case of the oscillator, we measured the spectrum, the pulse buildup time, the temporal duration time of the pulse, and the output energy according to the variation of the pumping energy, resonator length, and the reflectance of the output coupler. And, in the case of the amplifier, we investigated and analyzed the output energy of the amplifier as a function of the time difference between the two pump beams of the oscillator and the amplifier, the pumping energy of the oscillator, and the pumping energy of the amplifier When pump energies of both the oscillator and the amplifier were 18 mJ/pulse, we could find that the output energy of the amplifier increased linearly and gradually up to the time difference of 35 ns. Finally, we determined that the slope efficiencies of the oscillator and the amplifier were 23.5 % and 11.6 %, respectively.

A Study of the Fiber Fuse in Single-mode 2-kW-class High-power Fiber Amplifiers (단일 모드 2 kW급 고출력 광섬유 증폭기 내의 광섬유 용융 현상에 관한 연구)

  • Lee, Junsu;Lee, Kwang Hyun;Jeong, Hwanseong;Kim, Dong Jun;Lee, Jung Hwan;Jo, Minsik
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.1
    • /
    • pp.7-12
    • /
    • 2020
  • In this paper, we experimentally investigate the fiber fuse in single-mode 2-kW-class high-power fiber amplifiers, depending on the cooling method at the splicing point. We measured the temperature of the splicing point between the pump-signal combiner and gain fiber as a function of laser output power. The temperature of the splicing point increased from 20 to 32℃ with a slope of 0.01℃/W, up to 1.2 kW of laser output power. At higher powers the temperature of the splicing point increased dramatically, with a slope of 0.08℃/W. After that, the fiber amplifier was destroyed during operation at 1.96 kW of output power by fiber fuse. The bullet shape, a common feature of fiber fuse, was observed in the damaged passive fiber core of the pump-signal combiner. Later, we adopted an improved water-cooled cold plate to increase the cooling efficiency at the splicing point, and investigated the laser output power. The temperature at the splicing point was 35.8℃ with a temperature-rise slope of 0.007℃/W at the maximum output power of 2.05 kW. The beam quality M2 was measured to be less than 1.3, and the output beam's profile was a stable Gaussian shape. Finally, neither fiber fuse nor mode instability was observed in the fiber amplifier at the maximum output power of 2.05 kW.

Quasi-continuous-wave Yb-doped Fiber Lasers with 1.5 kW Peak Power (첨두 출력 1.5 kW급 준연속 이터븀 첨가 광섬유 레이저)

  • Jeon, Minjee;Jung, Yeji;Kim, Jiwon;Jeong, Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.3
    • /
    • pp.95-100
    • /
    • 2016
  • High-power quasi-continuous-wave (qcw) operation in Yb-doped double-clad fiber lasers with near-diffraction-limited quality of the output beam is reported. Based on numerical simulation, we built a simple, all-fiberized Yb fiber laser, and a fiber-based master-oscillator power amplifier (MOPA). Both laser systems have successfully produced qcw output with average power greater than 150 W at 1080 nm and 10 ms pulse duration at 10 Hz repetition rate, corresponding to a peak power greater than 1.5 kW for 205 W of pump power at 976 nm. Laser performance, including beam quality and slope efficiency, was characterized in both configurations. Prospects for power scaling and applications are discussed.

An Experimental Study on the Flame Structure of Partially Premixed Flame using OH PLIF (OH PLIF를 이용한 부분 예혼합 화염의 화염구조에 관한 실험적 연구)

  • Lee, Seung-Young;Lee, Jong-Ho;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.54-59
    • /
    • 2001
  • OH radical concentration have been measured in a methane-air partially premixed flames using PLIF. Excitation lines were selected $Q_{1}(6)$ branch, (1,0) band. The system is consisted of Nd:YAG laser, dye laser and frequency doubler to make pump beam for OH radical. On the direct photographs, flame height increases as fuel flow rate and equivalence ratio increase. And on the PLIF images, OH radical is distributed from premixed flame front to nonpremixed flame front through the flame structure with all equivalence ratio. OH overall concentrations increase with equivalence ratio. At the stoichiometric equivalence ratio, the peak of OH radical concentration exists strongly near the inner cone. As equivalence ratio is changed to richer, OH radical distribution goes thinly and the peak is increased as longitudinal direction. As the flow goes to the downstream, OH radical concentration decreases and broadens, because OH radical reacts with another species after OH formation at the initial oxidization. This phenomenon resembles radial distribution. At the l00cc fuel flowrate, the radial peak of OH radical exists from x/R=l.0 to 1.5.

  • PDF

Characteristics of Water Leakage from Cooling Components in a Storage Ring (방사광 차단용 진공부품의 냉각수 누설 특성)

  • Park, C.D.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • We analyzed the characteristics of water leakage from cooling components of the storage ring in the Pohang Light Source. The water leaks led localized pressure bumps and abnormal pressure changes. The leakage also changed the residual gas compositions depending not only on the position between leakage place to gas analyzer but also on on/off switching of ion pump and electron beam. We found that the residual gas analysis of $CH_4$, CO, NO was useful in determining water leaks.

Heteroepitaxial Structure of ZnO Films Deposited on Graphene, $SiO_2$ and Si Substrates

  • Pak, Sang-Woo;Cho, Seong-Gook;Kim, Eun-Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.309-309
    • /
    • 2012
  • Heteroepitaxial growth remains as one of the continuously growing interests, because the heterogeneous crystallization on different substrates is a common feature in the fabrication processes of many semiconductor materials and devices, such as molecular beam epitaxy, pulsed laser deposition, sputtering, chemical bath deposition, chemical vapor deposition, hydrothermal synthesis, vapor phase transport and so on [1,2]. By using the R.F. sputtering system, ZnO thin films were deposited on graphene 4 and 6 mono layers, which is grown on 400 nm and 600 nm $SiO_2$ substrates, respectively. The ZnO thin layer was deposited at various temperatures by using a ZnO target. In this experimental, the working power and pressure were $3{\times}10^{-3}$ Torr and 50 W, respectively. The base pressure of the chamber was kept at a pressure around $10^{-6}$ Torr by using a turbo molecular pump. The oxygen and argon gas flows were controlled around 5 and 10 sccm by using a mass flow controller system, respectively. The structural properties of the samples were analyzed by XRD measurement. The film surface and carrier concentration were analyzed by an atomic force microscope and Hall measurement system. The surface morphologies were observed using field emission scanning electron microscope (FE-SEM).

  • PDF

Analysis of Surface Reflection All-Optical Switches using InGaAs/InAlAs Multiple Quantum Wells (InGaAs/InAlAs 다중 양자우물을 이용한 표면 반사형 전광 스위치의 해석)

  • Choi, Yong-Ho;Kim, Kyung-Whan;Choi, Woo-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.9
    • /
    • pp.23-30
    • /
    • 2000
  • The performance of two types of surface reflecting all-optical switches with InGaAs/InAlAs multiple quantum wells are investigated. The absorption spectra and the refractive index changes of the quantum well are calculated for various pump and probe beam intensities and device conditions. From theses results, on ON/OFF ratio and switching speed of the two switches are compared. It is shown that the switch using DBR has higher ON/OFF ratio and higher switching speed than the switch without DBR.

  • PDF

Numerical Analyses of O-Cell Load Test on Pile (양방향말뚝재하시험의 수치해석)

  • Joo, Yong-Sun;Kim, Nak-Kyoung;Kim, Woong-Jin;Park, Jong-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.748-753
    • /
    • 2008
  • Bi-directional load test is one of O-cell tests. The O-cell test is a system which may be used for performing static load tests on cast in situ reinforced concrete bored piles. The technique was devised and developed by Osterberg of Northwestern University(USA) and has been in use around the world. The principle of the method is that an O-cell is installed in a cast in situ bored pile base. Once the pile concrete reaches its design strength the cell is connected to an hydraulic pump and pressured. Pressurisation causes the cell to expand, developing an upward force on the section of pile above the cell loads, pile movements and strains within the pile then enable the capacity of the pile and its load settlement curves to be ascertained. Bi-directional load tests using O-cell are now becoming common practice around the world, particularly where the loads to be applied are high or where it is not convenient to perform top-down loading tests. In the study, calculate ultimate capacity of bi-directional load test using FEM and beam on elasto-plastic foundation theory.

  • PDF