• Title/Summary/Keyword: Pump array

Search Result 35, Processing Time 0.02 seconds

A Hydraulic Model Stydy of the Water-Intake Structure near River Mile 37 on the Missouri River

  • Byungman-Yoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1992.07a
    • /
    • pp.133-141
    • /
    • 1992
  • A three water-intake structure designed to built along the right bank of the Missouri River near Chesterfield, Missouri was model-tested at an undistorted scale of 1:5. Although the discharge capacity of each of six pumps to be installed is only 21,000 gpm, the model indicated strong flow circuation and unstable free-surface conditions as flow entered the two-pump bay through a narrow sluice opening at an angle. Strong free-surface vartices were also observed in the model. The sump modifications developed in the study included an array of baffle bars, a perforated plate, floor splitters, and floor-corner fillets. The solutions developed in this study could be applied to other pump sumps with multiple pump units.

  • PDF

A Study on Performance Characteristics of Heat Exchanger for Heat Pump with R410A Refrigerant (R410A 냉매를 사용한 열펌프용 열교환기의 형상에 따른 성능특성 연구)

  • 정규하;박윤철;오상경
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.340-348
    • /
    • 2004
  • The air and refrigerant side heat transfer performances are key parameters to improve heat transfer efficiency of the heat exchanger including the fan performance. Design of the fins, treatment of the tube inside, tube diameter and tube array effect heat transfer performance of the heat exchanger. The heat exchanger is used as a condenser at cooling mode and used as an evaporator at heating mode in the heat pump system. The heat pump system uses R410A as the refrigerant. The heat exchangers are consisted with 7 mm diameter tubes with slit-type fins. The study was conducted with variation of arrangement of the refrigerant path and air flow rate and refrigerant pressure drop and heat transfer rate were measured with a code tester. The capacity of the 3 path heat exchanger is more efficient than 2 or 4 path heat exchangers in heating or cooling modes.

pH Measurements with a Microcantilever Array-Based Biosensor System

  • Hur, Shin;Jung, Young-Do
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.186-191
    • /
    • 2012
  • In this paper, we present a pH measurement method that uses a microcantilever-array-based biosensor system. It is composed of microcantilever array, liquid cell, micro syringe pump, laser diode array, position sensitive detector, data acquisition device, and data processing software. Four microcantilevers are functionalized with pH-sensitive MHA(mercaptohexadecanoic acid) as a probe, while three microcantilevers are functionalized with HDT(hexadecane thiol) as reference. We prepare PBS(phosphate buffered saline) solutions of different pH and inject them into the liquid cell with a predefined volumetric speed at regular time intervals. The functionalized mircocantilevers in the liquid cell deflect as a self-assembled monolayer on the microcantilever binds with probe molecules in the solution. The difference in deflection between the MHA-covered probe microcantilever and the HDT-covered reference microcantilever was used to compensate for thermal drift. The deflection difference clearly increases with increasing pH in the solution. It was shown that when the pH values of the PBS solutions are high, there were large variations in the deflection of microcantilevers, whereas there were small variations for low pH value. The experimental results show that the microcantilever array functionalized with MHA and HDT can detect pH value with good repeatability.

A Fabrication and Experiment of Induction-type EHD Micropump with Temperature Gradient (온도차를 이용한 유도형 마이크로 EHD 펌프의 제작 및 실험)

  • Youn, Yong-Kyu;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.198-200
    • /
    • 1993
  • This paper represents the experimental results of electrohrdrodynamic(EHD) micropump driven by traveling- wave voltage. We fabricated 60 electrodes array with $100{\mu}m$ width and $100{\mu}m$ interval on the pyrex glass. On that glass we fabricated the micro channel which had the cross section of 3mm by 0.5mm. This pump was driven by 6 phase square traveling-wave voltage. We used the corn oil for experiments and increased the temperature of fluid by resistive heater. An optical microscope with CCD camera and monitor was used for observation. The fluid velocity was large for the large driving voltage and the high temperature. This EHD pump had the fluid velocity in specific frequency (near 1Hz) which had relation to the charge relaxation time in that oil.

  • PDF

Performance Estimation and Test of Protype Pulse Tube Cryopump (맥동관형 크라이오펌프 시제품 성능예측과 평가)

  • In, Sang Ryul;Kang, Sang Paek
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.2
    • /
    • pp.45-54
    • /
    • 2013
  • The cryopump of the pulse tube type has been developed successfully, and manufacturing of a prototype pump is finished under leading of Woosung Vacuum. The target pumping speed of the prototype pump is above 3,600 L/s for nitrogen with the intake port of 14 inches I.D (16 inches O.D). For designing optimally the pump structure including the charcoal array, thermal shield, and baffle, the pumping speed was simulated for various configurations through Monte Carlo method. Pumping performances of the protype cryopump manufactured on the basis of optimal design were conformed experimentally with a standard test system and procedures. The measured $N_2$ pumping speed of the prototype cryopump was 4,600 L/s which agreed well with simulated one and exceeded the target value.

Fabrication of Transient Absorption Spectroscopic System and Measurement of Transient Absorption Changes of DDI (순간흡수 분광학 측정장치 구성 및 DDI의 순간흡수율 변화 측정)

  • Seo, Jung-Chul;Lee, Min-Yung;Kim, Dong-Ho;Jeong, Hong-Sik;Park, Seung-Han;Kim, Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.209-213
    • /
    • 1991
  • Recently, the developments in generating and amplifying ultrashort optical pulses $(ps=10^{-12}s or fs=10^{-15}s)$ have imposed on great advances in the time-resolved laser spectroscopy. Especially, the transient absorption spectroscopy has a wide application range and the main idea of this technique is pump & probe method. After the pump pulse makes the material an excited or a transient states, the probe pulse is sent through the material to measure the absorbance change due to the transient states. Here, if the absorbance change was measured by the time delay between pump & probe pulses, the dynamic information of the excited or the transient states (the transient abnsorption changes by time & wavelength) can be obtained. At our laboratory, the ultrashort optic1 pulse (

  • PDF

A Study on the contamination measurement of spacecraft components under High Vacuum Environment (고진공하에서의 위성체 부품의 오염측정에 관한 연구)

  • 이상훈;서희준;문귀원;최석원
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.2
    • /
    • pp.87-96
    • /
    • 2002
  • Outgassing from such sources as paints, coatings, adhesives and other non-metallic surfaces can contaminate satellites, especially second surface mirror and optical lens, it cause satellite to fail in own missions. The vacuum bake-out test using high temperature(more than $85 ^{\circ}C$)and high vacuum(less than $5.0{\times}1-^{-3}$ Pa) certify that the components of satellite work properly and can survive and operate in space environment like high vacuum. In the bake-out chamber installed at SITC of KARI, Rotary vacuum pump and Booster pump produce low vacuum of 5.0 Pa, and then two cryopumps produce high vacuum of below $5.0{\times}10^{-3}$ Pa. Also 48 ceramic heaters were provided to simulate high temperature. During the vacuum bake-out test, we detected contaminants using RGA(Residual Gas Analyzer) and measure the outgassing rate of the contaminant using the TQCM(Thermoelectric Quartz Crystal Microbalance). Also, IR/UV Spectrometer and witness plate be used to certify that the components were suitable for the spacecraft. This paper includes the preparation and procedures of the bake-out test for SAR(Solar Array Regulator) and MLI(Multi Layer Insulator), which were the components of the spacecraft. Especially, we discussed the methods and results of the contamination measurement. In the bake-out for SAR, the contamination was measured continuously although it was on the decrease from TQCM results. And RCA established that it is a highly polymerized compound. In the MLI bake-out using RGA and witness plate, we didn't detect any contamination materials.

Design of a Low-Power and Low-Area EEPROM IP of 256 Bits for an UHF RFID Tag Chip (UHF RFID 태그 칩용 저전력, 저면적 256b EEPROM IP 설계)

  • Kang, Min-Cheol;Lee, Jae-Hyung;Kim, Tae-Hoon;Jang, Ji-Hye;Ha, Pan-Bong;Kim, Young-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.671-674
    • /
    • 2009
  • We design a low-power and low-area asynchronous EEPROM of 256 bits used in a passive UHF RFID tag chip. For a low-power solution, we use a supply voltage of 1.8V and design a Dickson charge pump using N-type Schottky diodes with a low-voltage characteristic. And we use an asynchronous interface and a separate I/O method for a low-area solution of the peripheral circuit of the designed EEPROM. And we design a Dickson charge pump using N-type Schottky diodes to reduce an area of DC-DC converter. The layout area of the designed EEPROM of 256 bits with an array of 16 rows and 16 columns using $0.18{\mu}m$ EEPROM process is $311.66{\times}490.59{\mu}m^2$.

  • PDF

Development of UBMS(Unbalanced Magnetron Sputtering) System and Ion Current Density Measurement of Copper Target (UBM 마그네트론 스퍼터 시스템을 이용한 구리 타겟의 이온전류밀도 향상 연구)

  • Kang, Chunghyeon;Joo, Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.3
    • /
    • pp.192-197
    • /
    • 2017
  • A 6-way-cross consisting of a 2.75-inch CF flange was used as a main chamber on a PFEIFFER VACUUM TMP station based on a 67 l / sec turbo molecular pump and a diaphragm pump to produce a magnet array with a volume ratio of 5.5: 1.A 1-inch diameter copper target and graphite target were fabricated using MDX-1.5K from Advanced Energy Industries, Inc as a DC power supply. Ion current density of copper target and graphite target was measured by unbalanced magnetron sputtering. The basic pressure condition was $6.3{\times}10^{-7}mbar$ and the process pressure was Ar 50 sccm at $1.0{\times}10^{-2}mbar$ (7.5 mTorr) in the Ar atmosphere. Therefore, the relative density of copper ions reaching the substrate with the measured ion current density was derived.