Abstract
The air and refrigerant side heat transfer performances are key parameters to improve heat transfer efficiency of the heat exchanger including the fan performance. Design of the fins, treatment of the tube inside, tube diameter and tube array effect heat transfer performance of the heat exchanger. The heat exchanger is used as a condenser at cooling mode and used as an evaporator at heating mode in the heat pump system. The heat pump system uses R410A as the refrigerant. The heat exchangers are consisted with 7 mm diameter tubes with slit-type fins. The study was conducted with variation of arrangement of the refrigerant path and air flow rate and refrigerant pressure drop and heat transfer rate were measured with a code tester. The capacity of the 3 path heat exchanger is more efficient than 2 or 4 path heat exchangers in heating or cooling modes.
Keywords
Heat exchanger; Fin-tube; Pressure drop; Slit fin; Mass flow rate; Condensation; Evaporation;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 RAC with alternative refirgerant R410A /
[ Akutsu,M.(et al.) ] / Sanyo Technical Review
2 Performance and reliability of room air conditioner using R410A /
[ Nonaka,M.(et al.) ] / The Int. Symp. on HCFC Alternative Refrigerants
3 Comparison of performance veriation between R-22 and R410A refrigeration systems /
[ Park,T.J.;Lee,M.K.;Jeong,J.H.;Chang,K.S. ] / Korea Journal of Air-Conditioning and Refrigeration Engineering   과학기술학회마을
4 Comparison of R407C and R410A with R22 in a 10.5 kW residential central air-conditioner /
[ Murphy,F.T.;Low,R.E.;Gilbert,B.E.;Linton,J.W.;Snelson,W.K.;Hearty,P.F. ] / Proceeding of International CFC and Halon Aternative Conference
5 The study of Performance evaluation coefficient of fin and tube heat exchangers with frosting /
[ Choi,B.J.;Hwang,J.H.;Shin,J.M. ] / Korea Journal of Air-Conditioning and Refrigeration Engineering   과학기술학회마을
6 An experimental study on condensation characteristics of slit fin-tube heat exchanger using alternative refrigerants /
[ Jeon,C.D.;Jang,K.K.;Kang,S.H.;Lee,J. ] / Korea Journal of Air-Conditioning and Refrigeration Engineering
7 Room A/C /
[ Nakayama,M.(et al.) ] / Ref.