Effective Cu Filling Method to TSV for 3-dimensional Si Chip Stacking (3차원 Si칩 실장을 위한 효과적인 Cu 충전 방법)

  • Hong, Sung Chul;Jung, Do Hyun;Jung, Jae Pil;Kim, Wonjoong
    • Korean Journal of Metals and Materials
    • /
    • 제50권2호
    • /
    • pp.152-158
    • /
    • 2012
  • The effect of current waveform on Cu filling into TSV (through-silicon via) and the bottom-up ratio of Cu were investigated for three dimensional (3D) Si chip stacking. The TSV was prepared on an Si wafer by DRIE (deep reactive ion etching); and its diameter and depth were 30 and $60{\mu}m$, respectively. $SiO_2$, Ti and Au layers were coated as functional layers on the via wall. The current waveform was varied like a pulse, PPR (periodic pulse reverse) and 3-step PPR. As experimental results, the bottom-up ratio by the pulsed current decreased with increasing current density, and showed a value of 0.38 on average. The bottom-up ratio by the PPR current showed a value of 1.4 at a current density of $-5.85mA/cm^2$, and a value of 0.91 on average. The bottom-up ratio by the 3-step PPR current increased from 1.73 to 5.88 with time. The Cu filling by the 3-step PPR demonstrated a typical bottom-up filling, and gave a sound filling in a short time.

Investigation of 0.5 MJ superconducting energy storage system by acoustic emission method.

  • Miklyaev, S.M.;Shevchenko, S.A.;Surin, M.I.
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.961-965
    • /
    • 1998
  • The rapid development of small-scale (1-10 MJ) Superconducting Magnetic Energy Storage Systems (SMES) can be explained by real perspective of practical implementation of these devices in electro power nets. However the serious problem of all high mechanically stressed superconducting coils-problem of training and degradation (decreasing) of operating current still exists. Moreover for SMES systems this problems is more dangerous because of pulsed origin of mechanical stresses-one of the major sources of local heat disturbances in superconducting coils. We investigated acoustic emission (AE) phenomenon on model and 0.5 MJ SMES coils taking into account close correlation of AE and local heat disturbances. Two-coils 0.5 MJ SMES system was developed, manufactured and tested at Russian Research Center in the frames of cooperation with Korean Electrical Engineering Company (KEPCO) [1]. The two-coil SMES operates with the stored energy transmitted between coils in the course of a single cycle with 2 seconds energy transfer time. Maximum operating current 1.55 kA corresponds to 0.5 MF in each coil. The Nb-Ti-based conductor was designed and used for SMES manufacturing. It represents transposed cable made of Nb-Ti strands in copper matrix, several cooper strands and several stainless steel strands. The coils are wound onto fiberglass cylindrical bobbins. To make AE event information more useful a real time instrumentation system was used. Two main measured and computer processed AE parameters were considered: the energy of AE events (E) and the accumulated energy of AE events (E ). Influence of current value in 0.5 MJ coils on E and E was studied. The sensors were installed onto the bobbin and the external surface of magnets. Three levels of initial current were examined: 600A, 1000A, 2450 A. An extraordinary strong dependence of the current level on E and E was observed. The specific features of AE from model coils, operated in sinusoidal vibration current changing mode were investigated. Three current frequency modes were examined: 0.012 Hz, 0.03 Hz and 0.12 Hz. In all modes maximum amplitude 1200 A was realized.

  • PDF

Angular dependence of critical current of SmBCO coated conductor fabricated by co-evaporation method

  • Kim, Ho-Sup;Ha, Hong-Soo;Oh, Sang-Soo;Song, Kyu-Jeong;Ko, Rock-Kil;Ha, Dong-Woo;Kim, Tae-Hyung;Youm, Do-Jun;Lee, Nam-Jin;Moon, Seung-Hyun;Yoo, Sang-Im;Park, Chan
    • Progress in Superconductivity and Cryogenics
    • /
    • 제10권2호
    • /
    • pp.16-19
    • /
    • 2008
  • Angular dependence of critical current density of SmBCO coated conductor fabricated by co-evaporation method was investigated. For comparison, three samples were fabricated by a co-evaporation method and one sample was fabricated by a pulsed laser deposition process. The deposition system, named EDDC (Evaporation using Drum in Dual Chambers), is a batch type co-evaporation system, which is composed of reaction chamber and evaporation chamber. The normalized critical current density ratio ($I_c/I_c$(H//ab-plane)) of EDDC-SmBCO samples was found to be higher than that of PLD-YBCO sample in the whole range of angle. While the EDDC-SmBCO samples evidently had a peak at the angle of H//c-axis in the plot of the angular dependence of critical current, the normalized critical current of PLD-YBCO sample decreased monotonically without any peak as angle increased. The field dependence of critical current under the magnetic field parallel to the normal direction of those samples showed similar aspect in the range of $0\;G{\sim}5000\;G$.

Acceleration of Wound Healing and Collagen Deposition in Rat Skin by High Voltage Pulsed Current Stimulation (고전압맥동전류자극이 흰쥐 피부 창상치유와 교원질 축적에 미치는 효과)

  • Lee Jae-hyoung;Song In-young;Kim Jong-Gyu
    • The Journal of Korean Physical Therapy
    • /
    • 제15권4호
    • /
    • pp.1-12
    • /
    • 2003
  • The purpose of this study was to investigate the effect of high voltage pulsed current stimulation (HVPCS) on the healing rate of a dermal wound in a rat. We also determined the mechanism of promoting healing by HVPCS. Twenty male Sprague-Dawley rats were randomly divided into two group; HVPCS group (n=10) and control group (n=10). The HVPCS rats received electrical stimulation with a current intensity of 50 V at 100 pps for a duration of 30 minutes, while the control group was given the same treatment without electricity for a week. The biopsy specimens were fixed in formalin, embedded in paraffin and stained with Masson's trichrome, hematoxylin and eosin (H&E). The fibroblasts and collagen density were counted using a light microscope and computerized image analysis system and calculated as the density and the percent. A Student t-test showed a significantly higher wound healing rate of the HVPCS group than control (t=-4.161, p<0.001). The fibroblasts in the HVPCS group were higher than in the control group (t=-4.921, p<0.001). The density of collagen in the HVPCS group was also higher than in the control group (t=-4.367, p<0.001). These results indicate that the HVPCS accelerated the rate of healing in dermal wound, and increased fibroblasts and collagen density in the regenerative dermis. These findings suggest that the HVPCS may activate fibroblasts by alteration of the electrical environment, and it may increase collagen synthesis in the regenerative dermal wound.

  • PDF

Preparation of Ni Nanoparticles-TiO2 Nanotube Arrays Composite and Its Application for Electrochemical Capacitor

  • He, Huichao;Zhang, Yunhuai;Xiao, Peng;Yang, Yannan;Lou, Qing;Yang, Fei
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권5호
    • /
    • pp.1613-1616
    • /
    • 2012
  • Ni nanoparticles-$TiO_2$ nanotube arrays (Ni/$TiO_2NTs$) composites were prepared by pulsed electrodeposition method and subsequently characterized by means of field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD) and energy dispersive X-ray spectroscopy (EDX). The FESEM results showed that highly dispersed Ni nanoparticles were not only loaded on the top of the $TiO_2NTs$ but also within the tubular structure, and the particle size of Ni prepared at different current amplitude (100, 200 and 300 $mA{\cdot}cm^{-2}$) was in the range of 15 to 70 nm. The electrochemical studies indicated that Ni nanoparticles loaded on the highly ordered $TiO_2NTs$ are readily accessible for electrochemical reactions, which improve the efficiency of the Ni nanoparticles and $TiO_2NTs$. A maximum specific capacitance (27.3 $mF.cm^{-2}$) was obtained on the Ni/$TiO_2NTs$ composite electrode that prepared at a current of 200 $mA.cm^{-2}$, and the electrode also exhibited excellent electrochemical stability.

Mechanical Properties and Fabrication of WC-Co Hard Materials by Rapid Sintering Method for Friction Stir Welding Tool Application (급속소결 방법을 이용한 마찰교반 접합 툴용 WC-Co 소결체 제조 및 특성 평가)

  • Park, Hyun-Kuk;Youn, Hee-Jun;Ryu, Jung-Han;Jang, Jun-Ho;Shon, In-Jin;Oh, Ik-Hyun
    • Journal of Welding and Joining
    • /
    • 제30권6호
    • /
    • pp.92-97
    • /
    • 2012
  • Using the pulsed current activated sintering method, the WC-10wt.% Co materials were densified using a WC and Co powder. The WC-Co almost completely dense with a relative density of up to 99.5 % after the simultaneous application of a pressure of 60 MPa and an electric current for 3 minutes almost without any significant change in the grain size. The average grain size of about $0.3{\mu}m$. The hardness and fracture toughness at $1000^{\circ}C$ were about $2200kg/mm^2$ and $9.8MPa.m^{1/2}$, respectively.

Electrolytic Synthesis of Cobalt Nanorods without Using a Supporting Template (템플릿 없이 전해 합성된 코발트 나노 로드)

  • Kim, Seong-Jun;Shin, Heon-Cheol
    • Korean Journal of Materials Research
    • /
    • 제24권6호
    • /
    • pp.319-325
    • /
    • 2014
  • Cobalt nano-rods were fabricated using a template-free electrochemical-deposition process. The structure of cobalt electro-deposits strongly depends on the electrolyte composition and on the density of the applied current. In particular, as the content of boric acid increased in the electrolyte, deposits of semi-spherical nuclei formed, and then grew into one-dimensional nano-rods. From analysis of the electro-deposits created under the conditions of continuous and pulsed current, it is suggested that the distribution of the active species around the electrode/electrolyte interface, and their transport, might be an important factor affecting the shape of the deposits. When transport of the active species was suppressed by lowering the deposition temperature, more of the well-defined nano-rod structures were obtained. The optimal conditions for the preparation of well-defined nano-rods were determined by observing the morphologies resulting from different deposition conditions. The maximum height of the cobalt nano-rods created in this work was $1{\mu}m$ and it had a diameter of 200 nm. Structural analysis proved that the nano-rods have preferred orientations of (111).

Comparison of $Y_2O_3$ and ZnO Nanoparticles Introduced in YBCO Multilayered Films as Artificial Pinning Centers (YBCO 다층박막에 첨가된 $Y_2O_3$와 ZnO 나노입자의 자속꽂음 중심 특성 비교)

  • Wie, C.H.;Tran, D.H.;Putri, W.B.K.;Kang, B.;Kim, Y.J.;Oh, S.J.;Lee, N.H.;Kang, W.N.
    • Progress in Superconductivity
    • /
    • 제13권2호
    • /
    • pp.90-96
    • /
    • 2011
  • We investigated the properties of artificial pinning centers of YBCO multilayer films in which $Y_2O_3$ and ZnO nanoparticles are uniformly introduced by using the pulsed laser deposition (PLD) technique. $Y_2O_3$ and ZnO nanoparticles were deposited on top of YBCO buffer layer and the density of nanoparticles was controlled by varying the number of nanoparticle layers. YBCO superconducting layers with total thickness of 250 nm were deposited on top of $Y_2O_3$ and ZnO nanoparticles. Based on analyses of the surface morphology, the transition temperature $T_c$, and the critical current density $J_c$, we discussed the difference between the two kinds of nanoparticles as flux pinning centers.

Oxygen Annealing Effect of SrTiO$_3$ Single Crystal Substrate Damaged by Ar$^+$ Ion Milling (Ar 이온 밀링으로 손상된 단결정 SrTiO$_3$ 기판의 산소 열처리 효과)

  • Choi, Hee-Seok;Hwang, Yun-Seok;Kim, Jin-Tae;Lee, Doon-Hoon;Lee, Soon-Gul;Park, Yong-Ki;Park, Jong-Chul
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.87-90
    • /
    • 1999
  • We have studied the annealing effects of 570 (SrTiO$_3$) single crystal substrate and the I-V properties of step-edge junctions after Ar ion milling. YBa$_2Cu_3O_7$ (YBCO) thin films are fabricated on the substrates by using pulsed laser deposition (PLD) and photolithography. The surface of Ar ion milled substrate was characterized with atomic force microscope (AFM) and scanning electron microscope (SEM) images. After the substrate was damaged by milling, the critical current density of YBCO thin films deposited on the substrate was lowered. The annealing of the damaged substrate at about 1000 $^{\circ}C$ recovered the critical current density to that before the milling. Futhermore the annealing helped junction formation due to high quality film and increased the yield rate for the fabrication of high quality step-edge junction.

  • PDF

Effect of an additional resistance on Shapiro steps of the Josephson junction (조셉슨 접합의 샤피로 계단특성에 대한 부가저항의 효과)

  • Shim, Woo-Seok;Cho, Won-Il;Song, I-Hun;Kim, Do-Hyun;Park, Gwang-Seo;Song, In-Sang
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.223-228
    • /
    • 1999
  • We have investigated the microwave properties of a high-T$_c$. superconducting Josephson junction by Shapiro step measurements. A Josephson junction was fabricated on the bicrystal MgO substrate using pulsed laser deposition method. We have measured Shapiro steps in the I-V characteristics under the irradiation of 1.36 cm wavelength up to 45 K and found inclined current steps above 50 K. In order to understand these results, we introduced an additional resistance connected in series to RSJ model. Using this modified RSJ model, we could explain the inclined current steps as a result of superposition of the junction and an additional resistance above certain temperatures. Also, we presented the received power of the Josephson junction above 50 K.

  • PDF