• Title/Summary/Keyword: Pulse width

Search Result 1,790, Processing Time 0.034 seconds

Inspection on the acoustic output of the focused extracorporeal focused shock wave therapeutic devices approved by MFDS (식약처에서 허가된 집속형 ESWT 치료기의 음향 출력 분석)

  • Choi, Min Joo;Jeon, Sung Joung;Kwon, Oh Bin;Lee, Min Young;Cho, Jin Sik;Kim, Han Soo;Maeng, Eun Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.4
    • /
    • pp.303-317
    • /
    • 2020
  • Extracorporeal Shock Wave Therapy (ESWT) is an innovative treatment in chronic musculoskeletal pain management and cardiovascular diseases. In this study, we surveyed the acoustic shock wave outputs from the domestically used focal type ESWT devices. The survey data were collected through 30 technical documents registered to the Ministry of Food and Drug Safety (MFDS), Rep. Korea. The results show that the focusing geometry varies largely, 5 mm to 65 mm in the focal length, 3 mm to 30 mm in focal width, and 4 mm to 108 mm in focal depth. The maximum positive pressure (P+) ranges from 7 MPa to 280 MPa, the focal Energy Flux Density (EFD) from 0.0035 mJ/㎟ to 35 mJ/㎟, and the energy per pulse (E) from 0.737 mJ to 80.86 mJ. All domestic PE-type (five) and one EM-type domestic devices included in the analysis of the correlation between P+ and EFD are shown to be far beyond the usual ranges and do not comply with expected correlation so that the reliability of their data was suspected. For the suspected, post-performance tests are required by a recognized testing agency. MFDS guidelines need to be revised so that the pass criteria for the shock wave acoustic outputs can be based on the clinical tests for indications.

Pulsed Electric Fields Effects on Drying of White Ginseng and Extraction of Soluble Components (백삼의 건조와 가용성 성분 추출에 미치는 pulsed electric fields(PEF)의 효과)

  • Lim, Jeong Ho;Shim, Jae Min;Lee, Dong Un;Kim, Young Ho;Park, Kee-Jai
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.704-710
    • /
    • 2012
  • This study was designed to investigate the effect of pulsed electric fields on the drying of ginseng and extraction of dried ginseng to reduce energy-consumption. Fresh ginseng was treated in a PEF system of 1 and 2 kV/cm electric field strength, 25 and 200 Hz of frequency, $30{\mu}s$ of pulse width and pulse number of 175. The samples were subsequently dried for 26 h at $55{\pm}1^{\circ}C$, and the characteristic of hot-water extraction on dried ginseng was investigated. The ginseng pretreated with an intensity of 2 kV/cm (200 Hz, n=175) resulted in a reduction of approximately 38% for drying time. The influence of PEF treatment on the water extraction of dried ginseng at $95{\pm}1^{\circ}C$ was also investigated. The application of an electric field intensity of 2 kV/cm (25 and 200 Hz, n=175) increased soluble solid content, significantly reducing sugar content and free sugar content of the extract compared to non-PEF-treated samples.

Decontamination Characteristics of 304 Stainless Steel Surfaces by a Q-switched Nd:YAG Laser at 532 nm (532 nm 파장의 큐스위치 Nd:YAG 레이저를 이용한 스테인리스 스틸 표면 제염특성)

  • Moon, Jei-Kwon;Baigalmaa, Byambatseren;Won, Hui-Jun;Lee, Kune-Woo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.181-188
    • /
    • 2010
  • Metal surface decontamination characteristics were investigated by using a laser ablation method. A second harmonic generation of a Q-switched Nd:YAG laser with a wave length of 532 nm, a pulse energy of 150 mJ and a pulse width of 5 ns was employed to assess the decontamination performance for metal surfaces contaminated with $CsNO_3$, $Co(NH_4)_2(SO_4)_2$, $Eu_2O_3$ and $CeO_2$. The ablation behavior was investigated for the decontamination variables such as a number of laser shots, laser fluence and an irradiation angle. Their optimum values were found to be 8, 13.3 J/$cm^2$ and $30^{\circ}$, respectively. The decontamination efficiency was different depending on the kinds of the contaminated ions, due to their different melting and boiling points and was in the order: $CsNO_3>Co(NH_4)_2(SO_4)_2>Eu_2O_3>CeO_2$. We also evaluated a correlation between the metal ablation thickness and the number of laser shots for the different laser fluences.

Intraosseous anesthesia in symptomatic irreversible pulpitis: Impact of bone thickness on perception and duration of pain

  • Nilius, Manfred;Mueller, Charlotte;Nilius, Minou Helene;Haim, Dominik;Leonhardt, Henry;Lauer, Guenter
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.6
    • /
    • pp.367-375
    • /
    • 2020
  • Background: Intraosseous anesthesia (IO) allows the anesthetic solution to be injected directly into the cancellous bone. The anesthetic solution immediately reaches the periapical region, and thus the axonal area of the nerve, where it can temporarily disable the sodium pump. The effect is felt almost without any time delay, and only a small amount of anesthetic solution is required. Methods: This study aims to investigate the efficacy of IO using the AnestoⓇ device after infiltration anesthesia (IA) and/or inferior alveolar nerve block anesthesia (IANB) failed to work in symptomatic irreversible pulpitis (hot tooth). The 33 patients included in the study were treated additionally with 1.7 ml articaine hydrochloride with 1:100,000 epinephrine hydrochloride (UltracainⓇ D-S, Sanofi-Aventis, Frankfurt, Germany) IO. Results: The electrical pulp test showed that 95.76% of the volunteers reacted positively to the combination of IANB or IA with the IO. In women, the additive IO was effective at 97.22%. In men, the IO led to pain elimination in 94.00% of cases. The duration of the IO was less than a quarter of an hour (13.03 min). The IO worked longer in women than in men (13.61 min vs. 12.33 min). Overall, more than every third tooth that needed trepanation was located in the posterior area of the mandible (36.4%). Treatment of hot teeth in this area was associated with an increased pulse rate and increased residual pain. There was a moderate correlation (Spearman-Rho [IRI] = 0.280) between the Visual Analog Scale (VAS) score and bone density, and a significant correlation (IRI = 0.612) between subjective residual pain and bone width. The IO resulted in a moderate, transient increase in the pulse rate by approximately 20 bpm. This is similar to the temporary increase in heart rate after conventional anesthesia techniques in non-preloaded patients and can be considered clinically irrelevant. Conclusion: IO with the AnestoⓇ device as an extension and deepening of local pain elimination is recommended for the treatment of hot teeth.

Correlation between magnetic resonance imaging and cone-beam computed tomography for maxillary sinus graft assessment

  • Laurino, Fernando Antonio Reis;Choi, Isabela Goulart Gil;Kim, Jun Ho;Gialain, Ivan Onone;Ferraco, Renato;Haetinger, Rainer Guilherme;Pinhata-Baptista, Otavio Henrique;Abdala-Junior, Reinaldo;Costa, Claudio;Cortes, Arthur Rodriguez Gonzalez
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.93-98
    • /
    • 2020
  • Purpose: Little is known regarding the accuracy of clinical magnetic resonance imaging (MRI) protocols with acceptable scan times in sinus graft assessment. The aim of this study was to evaluate the correlations between MRI and cone-beam computed tomographic (CBCT) measurements of maxillary sinus grafts using 2 different clinical MRI imaging protocols. Materials and Methods: A total of 15 patients who underwent unilateral sinus lift surgery with biphasic calcium phosphate were included in this study. CBCT, T1-weighted MRI, and T2-weighted MRI scans were taken 6 months after sinus lift surgery. Linear measurements of the maximum height and buccolingual width in coronal images, as well as the maximum anteroposterior depth in sagittal images, were performed by 2 trained observers using CBCT and MRI Digital Imaging and Communication in Medicine files. Micro-computed tomography (micro-CT) was also performed to confirm the presence of bone tissue in the grafted area. Correlations between MRI and CBCT measurements were assessed with the Pearson test. Results: Significant correlations between CBCT and MRI were found for sinus graft height (T1-weighted, r=0.711 and P<0.05; T2-weighted, r=0.713 and P<0.05), buccolingual width (T1-weighted, r=0.892 and P<0.05; T2-weighted, r=0.956 and P<0.05), and anteroposterior depth (T1-weighted, r=0.731 and P<0.05; T2-weighted, r=0.873 and P<0.05). The presence of bone tissue in the grafted areas was confirmed via micro-CT. Conclusion: Both MRI pulse sequences tested can be used for sinus graft measurements, as strong correlations with CBCT were found. However, correlations between T2-weighted MRI and CBCT were slightly higher than those between T1-weighted MRI and CBCT.

Research on ANN based on Simulated Annealing in Parameter Optimization of Micro-scaled Flow Channels Electrochemical Machining (미세 유동채널의 전기화학적 가공 파라미터 최적화를 위한 어닐링 시뮬레이션에 근거한 인공 뉴럴 네트워크에 관한 연구)

  • Byung-Won Min
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.3
    • /
    • pp.93-98
    • /
    • 2023
  • In this paper, an artificial neural network based on simulated annealing was constructed. The mapping relationship between the parameters of micro-scaled flow channels electrochemical machining and the channel shape was established by training the samples. The depth and width of micro-scaled flow channels electrochemical machining on stainless steel surface were predicted, and the flow channels experiment was carried out with pulse power supply in NaNO3 solution to verify the established network model. The results show that the depth and width of the channel predicted by the simulated annealing artificial neural network with "4-7-2" structure are very close to the experimental values, and the error is less than 5.3%. The predicted and experimental data show that the etching degree in the process of channels electrochemical machining is closely related to voltage and current density. When the voltage is less than 5V, a "small island" is formed in the channel; When the voltage is greater than 40V, the lateral etching of the channel is relatively large, and the "dam" between the channels disappears. When the voltage is 25V, the machining morphology of the channel is the best.

Highly power-efficient and reliable light-emitting diode backlight driver IC for the uniform current driving of medium-sized liquid crystal displays

  • Hong, Seok-In;Nam, Ki-Soo;Jung, Young-Ho;Ahn, Hyun-A;In, Hai-Jung;Kwon, Oh-Kyong
    • Journal of Information Display
    • /
    • v.13 no.2
    • /
    • pp.73-82
    • /
    • 2012
  • In this paper, a light-emitting diode (LED) backlight driver integrated circuit (IC) for medium-sized liquid crystal displays (LCDs) is proposed. In the proposed IC, a linear current regulator with matched internal resistors and an adaptive phase-shifted pulse-width modulation (PWM) dimming controller are also proposed to improve LED current uniformity and reliability. The double feedback loop control boost converter is used to achieve high power efficiency, fast transient characteristic, and high dimming frequency and resolution. The proposed IC was fabricated using the 0.35 ${\mu}m$ bipolar-CMOS-DMOS (BCD) process. The LED current uniformity and LED fault immunity of the proposed IC were verified through experiments. The measured power efficiency was 90%; the measured LED current uniformity, 97%; and the measured rising and falling times of the LED current, 86 and 7 ns, respectively. Due to the fast rising and falling characteristics, the proposed IC operates up to 39 kHz PWM dimming frequency, with an 8-bit dimming resolution. It was verified that the phase difference between the PWM dimming signals is changed adaptively when LED fault occurs. The experiment results showed that the proposed IC meets the requirements for the LED backlight driver IC for medium-sized LCDs.

A Study on the Leading Phase Operation of Single Phase PWM Converter Train (단상PWM컨버터 차량의 진상운전에 관한 연구)

  • Kim, Baik
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.4
    • /
    • pp.357-363
    • /
    • 2012
  • This paper presents a new operation method for the single phase PWM(Pulse Width Modulation) converter train. Recently, the trains adopting the PWM converter have become the majority in the electric locomotives since there are distinct advantages over the predecessors, which can be operated at near unity power factor. However, a slight modification of the control scheme makes this kind of vehicles run in the region of leading power factor. Although this feature seems to be of no significant use by itself, the leading phase operation can improve the voltage profile and the line loss of the feeding systems is decreased by compensating the reactive power loss along the line when it considered together with the feeding systems. This method is even more economical and efficient comparing with the installation of SVC that is mainly used for this purpose since the train can become a movable compensator. With the conditions and some essential formula for the leading phase operation, a new power factor control algorithm has been proposed to implement this scheme. The results of simulation through SIMULINK model show that the proposed method is suitable enough for practical use.

MRAS Speed Estimator Based on Type-1 and Type-2 Fuzzy Logic Controller for the Speed Sensorless DTFC-SVPWM of an Induction Motor Drive

  • Ramesh, Tejavathu;Panda, Anup Kumar;Kumar, S. Shiva
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.730-740
    • /
    • 2015
  • This paper presents model reference adaptive system speed estimators based on Type-1 and Type-2 fuzzy logic controllers for the speed sensorless direct torque and flux control of an induction motor drive (IMD) using space vector pulse width modulation. A Type-1 fuzzy logic controller (T1FLC) based adaptation mechanism scheme is initially presented to achieve high performance sensorless drive in both transient as well as in steady-state conditions. However, the Type-1 fuzzy sets are certain and cannot work effectively when a higher degree of uncertainties occurs in the system, which can be caused by sudden changes in speed or different load disturbances and, process noise. Therefore, a new Type-2 FLC (T2FLC) - based adaptation mechanism scheme is proposed to better handle the higher degree of uncertainties, improve the performance, and is also robust to different load torque and sudden changes in speed conditions. The detailed performance of different adaptation mechanism schemes are performed in a MATLAB/Simulink environment with a speed sensor and sensorless modes of operation when an IMD is operates under different operating conditions, such as no-load, load, and sudden changes in speed. To validate the different control approaches, the system is also implemented on a real-time system, and adequate results are reported for its validation.

Design and Fabrication of S-Band GaN SSPA for a Radar (레이더용 S대역 GaN 반도체 전력증폭기 설계 및 제작)

  • Lee, Jeong-Won;Lim, Jae-Hwan;Kang, Myoung-Il;Han, Jae-Seob;Kim, Jong-Pil;Lee, Sue-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1139-1147
    • /
    • 2011
  • In this paper, a design and fabrication of GaN power amplifier for the S-band frequency (400 MHz bandwidth) are presented. A combining path using ${\lambda}$/4 transmission line is implemented for GaN pallet amp. Both the combiner with suspended-type transmission structure for low-loss and the suspended stripline coupler with aperture coupling for auto gain control are realized for achieving high-power high-efficiency amplifier. Proposed power amplifier demonstrated a 5 kW peak output power, 27.8 % efficiency, 67 dB gain without ALC and a 4 kW peak output power, 25.5 % efficiency, 0.1 dB droop at 200 usec pulse width and 10 % duty with ALC.