• Title/Summary/Keyword: Pulse wave

Search Result 1,041, Processing Time 0.029 seconds

유도결합플라즈마 장비에서 Pulse Modulation Plasma의 전자온도와 플라즈마밀도 컨트롤에 관한 연구

  • Jo, Tae-Hun;Yun, Myeong-Su;Son, Chan-Hui;Kim, Dong-Jin;Nam, Chang-Gil;Jeon, Bu-Il;Jo, Gwang-Seop;Gwon, Gi-Cheong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.406-406
    • /
    • 2012
  • 반도체 공정의 대부분은 plasma를 사용한 공정이 주를 이루고 있다. 이러한 공정에서 최근 선폭의 초 미세화가 진행되면서 pulse modulation plasma에 대한 관심을 가지게 되고 있다. Pulse modulation plasma는 RF 인가 시 일정 간격으로 on, off 시켜주게 된다. 이 때, chamber 내부에서 발생하는 plasma역시 on, off 되게 되는데 이러한 현상을 이용하면 plasma 내의 전자온도가 떨어져서 식각 공정 시 선택비의 개선을 기대할 수 있다. 실제 장비회사에서는 pulse를 이용하기 위한 장비개선 연구가 한창이다. 본 연구에서는 유도결합플라즈마 chamber에서 source와 bias에 RF pulse modulation plasma를 발생시켜 기존 CW (Continuous wave) 방전시킨 plasma의 밀도와 전자온도를 측정하여 차이를 비교, 분석 해보았다.

  • PDF

Evaluation of Significance on the Brachial-ankle arterial pulse wave velocity And Cerebral Artery Vascular Stenosis (상완-발목 맥파 전달 속도와 뇌동맥 혈관 협착과의 유의성 평가)

  • Kim, Ji-Yul;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.873-878
    • /
    • 2019
  • Cerebrovascular disease is one of the three major causes of death in Korea. Since these diseases are associated with atherosclerosis, the diagnosis of atherosclerotic factors should be presented. In this study, we evaluated the relationship between brachial-ankle arterial pulse wave velocity, cerebral artery vascular stenosis, blood pressure, obesity, and abdominal obesity by age group. The significance of cerebral artery stenosis and age group. The risk factors of atherosclerosis, such as blood pressure, obesity, and abdominal obesity, were significant in all age groups. When the pulse wave velocity of the brachial-ankle artery was increased, the cerebral artery stenosis was distributed in 57.3% of the total test subjects. If the arterial stiffness is suspected during the measurement of the pulse wave velocity of the brachial ankle artery, We recommend suspected vascular stenosis and perform a cerebral artery angiography. It is suggested that the data will be used as a baseline data for similar studies after evaluating the significance of blood pressure, obesity, and abdominal obesity as risk factors of atherosclerosis.

A Study on the Direction of Developing a Simulator for Performance Evaluation of Pulse Wave Detectors Through a Review of the Development Status of Cardiovascular Simulators (심혈관계 시뮬레이터 개발 동향 분석을 통한 맥파검사용기기 성능평가 시뮬레이터 연구개발 방향 모색)

  • Lee, Ju-Yeon;Kim, Jaeyoung;Go, Dong-Hyun;Lee, Ji-Won;Lee, Tae-Hee;Park, Chang-Won;Lee, Su-Kyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.136-146
    • /
    • 2022
  • In this study, it is intended to provide basic data that can help develop a cardiovascular simulator for performance evaluation of pulse wave detectors by identifying the development status of domestic and overseas cardiovascular simulators. A total of 119 papers were selected by excluding duplicate literature, gray literature, and literature not related to a cardiovascular simulator. Based on the selected literature, the research trend of cardiovascular simulators was analyzed. As a result of analyzing the purpose of the study, most of the simulators were developed to evaluate the hemodynamic properties of artificial hearts and valves. In addition, it was used for simulation evaluation or hemodynamic studies such as pulse wave studies. As a result of analyzing configurations of the simulators, a heart most often consisted of only one left ventricle. For blood vessels, the Windkessel model was most often constructed using chambers and valves. In most studies, blood was reproduced by mixing glycerin and water to reproduce both density and viscosity. In addition, as a result of analysis from the perspective of medical device performance evaluation, simulators for evaluating artificial heart and artificial valves have been studied a lot, whereas simulators for blood pressure, pulse wave, and blood flow devices have been relatively insignificant. Based on the review results, we suggested considerations when developing a simulator for performance evaluations of a pulse wave detector.

On Study of Pulse Wave Signal According to Postural Change Using Finger Plethysmography (손가락 끝 용적맥파를 이용한 자세변화에 따른 맥파 신호에 관한 연구)

  • Choi, B.C.;Kim, C.H.;Jung, D.K.;Suh, D.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.125-126
    • /
    • 1998
  • Pulse conduction velocity is determined by areterial compliance, which is changed by lateral pressure of arterial wall. Hydrostatic pressure of the limb vessel is changed by body position, especially in elevated arm. The arterial pulse in the finger causes the blood volume to change, changing the optical density of the blood. Photoplethysmograph of index finger was obtained by LED and phototransistor. Pulse transmission time(PTT) was measured by the interval between the peak of ECG R wave and the peak of the finger plethysmogram. PTT was increased by upward position of arm, and decreased by downward position of the arm compared to horizontal position. This result suggests that relationship between finger plethysmography and postural change could be applied to evaluate clinical cardiovascular status.

  • PDF

A Study on the Collection Characteristics of a Moving Electrode Electrostatic Precipitator - II. Effect of Wave Form of Pulse Energization and Dust Concentration - (이동 전극형 전기집진기의 집진특성에 관한 연구 - II. 펄스 하전 파형 및 분진농도의 영향 -)

  • Kim Yong-Jin;Ha Byung-Kil;Jeong Sang-Hyun;Hong Won-Seok;Yoo Joo-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.908-913
    • /
    • 2004
  • This study investigates the effect of the wave form of pulse energization and dust concentration on the collection characteristics of a moving electrode electrostatic precipitator (MEEP). Under the same specific corona power, the collection efficiency of the MEEP for the lower dust concentration ($2g/m^3$) becomes higher than that for the higher concentration ($10g/m^3$). Both the collection efficiency and specific corona power increase with increasing pulse period for the same value of applied voltage. The collection efficiency of MEEP is higher than that of the conventional fixed plate electrode electrostatic precipitator.

Comparative Study on the Pulse Wave Variables and Sasang Constitution in Cerebral Infarction Patients and Healthy Subjects (뇌경새(腦梗塞) 환자(患者)와 건강인(健康人)의 맥상(脈象)과 사상체질(四象體質)에 관(關)한 연구(硏究))

  • Ko, Ki-Duk;Kim, Kyung-Yo;Kim, Jong-Yeol;Lee, Si-Woo;Joo, Jong-Cheon
    • Journal of Pharmacopuncture
    • /
    • v.10 no.2 s.23
    • /
    • pp.119-132
    • /
    • 2007
  • This study was performed to determine whether a pulse analyzer was useful 1) to characterize the variables of pulse wave of cerebral infarction patieno (CI), compared with those of healthy subjects, as well as 2) to determine Sasang Constitution in CI and healthy subjects. 1. Calibrated in Gwan, the amount of energy(Energy), height of main peak(H1), height of aorticvalley(H2), height of aortic peak(H3), total area of pulse wave(At), and area of main peak width(Aw) of the CI group were higher than those of the healthy group. 2. Calibrated in Cheek, Energy, H1, H2, H3, height of valve valley(H4), At, Aw, and main peak angle(MPA) of the CI group were higher than those of the healthy group. 3. Among the healthy (subjects) group, Taeumin showed the highest contact pressure(CP) and height of valve peak(H5) calibrated in Chon. The main peak width divided by whole time of pulse wave(MPW/T) calibrated in Gwan and Cheok, was highest in Soyangin and was lowest in Taeumin. The H3 divided by H1(H3/H1) and the time to valve valley minus the time to main peak and divided by T[(T4-T1)/T] calibrated in Cheek were highest in Soyangin. The time to main peak(T1) was longest in Soumin. 4. Among the CI group, At calibrated in Chon was widest in Taeumin and was narrowest in Soumin The time to aortic peak(T3) calibrated in Cheek was longest in Soumin and was shortest in Soyangin. The time to valve peak(T5) was shortest in Soyangin. 5. There were main effects of cerebral infarction in the area of systolic period(As) and area of diastolic period(Ad) calibrated in Chon, Energy calibrated in Cwan, and Energy, H1, H2, H3, (H4+H5)/Hl, and MPA calibrated in Cheek. 6. There were main effects of Sasang Constitution in (T4-T1)/T, area of systolic period(As), and Ad calibrated in Chon. 7. The interactions between the cerebral infarction and Sasang Constitution were observed in H5/H1 , T, At, As, Ad, and MPA calibrated in Chon, H4, T4, (T4-T1)/T, As, and Ad calibrated in Cwan, and 74,75, and MPW calibrated in Cheok. Therefore, we concluded that pulse analyzer was useful to determine the risk degree of cerebral infarction and Sasang Constitution.

The Effect of Sa-Am Stomach Tonifying Acupuncture on Radial Pulse in Healthy Human Subjects (위정격(胃正格) 자침이 정상 성인의 맥파(脈波)에 미치는 영향)

  • Choi, Joo Young;Kang, Jae Hui;Yim, Yun Kyong;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.29 no.6
    • /
    • pp.57-71
    • /
    • 2012
  • Objectives : The purpose of this study is to find the effects of Sa-Am stomach tonifying acupuncture on radial pulse through the parameters difference. Methods : Forty healthy subjects participated in this study, acupuncture group and control group were divided. Radial pulse were measured using 3 dimensional pulse imaging system(DMP-3000). 19 parameters that significantly changed were selected after comparing between acupuncture group and control group. Then, 19 parameters were analyzed before, immediately after, 30 minutes after and 60 minutes after acupuncture in acupucture group. Results : 1. Heart rate, pulse period, T/T1, T2/T, T4/T, T5/T, T-T4, (T-T4)/T and T4/(T-T4) significantly changed after acupuncture. 2. H1 Amplitude, H2 Amplitude, H4 Amplitude and H5 Amplitude significantly changed after acupuncture. 3. Area of Pulse Wave, Systolic Pulse Area, Diastolic Pulse Area and Area of W significantly changed after acupuncture. 4. AIx/HR significantly changed after acupuncture. Conclusion : Stomach Tonifying Acupuncture exerts an influence on radial pulse parameters. Further radial pulse change study on various acupuncture treatment is required.

Review of the Domestic Trend of Pulse Diagnosis Studies in Korea (맥진 연구의 국내 동향에 대한 고찰)

  • Kan, Sei-young
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.6
    • /
    • pp.1152-1168
    • /
    • 2019
  • Objectives: The aim of this study was to present several proposals for future pulse diagnosis practice and research by investigating the trend of pulse diagnosis studies in Korea. Methods: We searched online medical databases, including National Discovery for Science Leaders (NDSL), the Oriental Medicine Advanced Searching Integrated System (OASIS), the Research Information Sharing Service (RISS), and the Korean Traditional Knowledge Portal (KTKP), for pulse diagnosis articles in Korea. We selected articles on pulse diagnosis but excluded duplicate articles, articles irrelevant to pulse diagnosis, and articles published in foreign countries. Results: In the first screening, 801 articles were selected. We found 251 articles and classified them according to category. The medical engineering field had 148 articles. A total of 24 articles were related to algorithms for pulse wave detection, 34 to sensors, five to pressurization technology, 16 to systems, 11 to remote medical service, five to mobiles, nine to trends, and 44 to basic research. The Korean medicine field had 103 articles. A total of 41 articles were devoted to literature reviews, 20 to case reports, 11 to constitutional medicine, six to experimental studies, and 25 to relevant research. Conclusion: More efforts to practice pulse diagnosis for various diseases should be made and the results actively published.

Parametric Study on Performance of Inertance Pulse Tube Cryocooler

  • Lee, K.H.;Rhee, J.;Kim, J.S.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.205-211
    • /
    • 2014
  • The design parameters to affect the cooling capacity of a cryocooler were examined with the application of numerical modeling to optimize an inertance pulse tube cryocooler. This modeling includes the regenerator, pulse tube, inertance tube, gas reservoir, and heat exchangers. One-dimensional modeling on strings of acoustic and thermoacoustic elements was applied to compare the design parameters. The diameter and length of the pulse tube can significantly affect the cooling capacity and efficiency. The aftercooler was optimized by maintaining a certain size. The efficiency also improved as the length of inertance tube and volume of gas reservoir are increased. It was confirmed that effective design parameters are critical to the performance of an inertance pulse tube cryocooler considering the comparison of the dimensions of each part to optimize its cooling power and efficiency.

A Study on the Auto-diagnosis Plethysmograph by Novel Algorithm for Radial Pulse Detection (새로운 맥파 인식 알고리즘을 적용한 자동 맥파 시스템에 관한 연구)

  • 박승환;홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.241-246
    • /
    • 1996
  • This paper describes a new system that detects radial pulse wave and allows the diagnosis of malfunctions of cardiovascular system by analyzing the waveforms with the newly proposed algorithm. The system consists of a sensor part and a data processing part within which a new detection algorithm is incorporated In acquiring radial pulse signal noninvasively, the sensor used in this system is a new combinational fiber-optic sensor which has a detecting Part and a transmitting Part. Also, In order to analyze the characteristics of pulsation quantitatively, the algorithm proposed in this paper is a method that runs in parallel with both the data of ECG and differential pulse simultaneously. these concepts are based upon the idea that thfee Q points of ECG give obious discrimination of one entire period of pulse in any abnormal cases, and newly defined feature lines at the differential counterpart can be used to recogrlize sDme significant points in one period of pulses.

  • PDF