• Title/Summary/Keyword: Pulse wave

Search Result 1,041, Processing Time 0.026 seconds

High-speed angular-scan pulse-echo ultrasonic propagation imager for in situ non-destructive evaluation

  • Abbas, Syed H.;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.22 no.2
    • /
    • pp.223-230
    • /
    • 2018
  • This study examines a non-contact laser scanning-based ultrasound system, called an angular scan pulse-echo ultrasonic propagation imager (A-PE-UPI), that uses coincided laser beams for ultrasonic sensing and generation. A laser Doppler vibrometer is used for sensing, while a diode pumped solid state (DPSS) Q-switched laser is used for generation of thermoelastic waves. A high-speed raster scanning of up to 10-kHz is achieved using a galvano-motorized mirror scanner that allows for coincided sensing and for the generation beam to perform two-dimensional scanning without causing any harm to the surface under inspection. This process allows for the visualization of longitudinal wave propagation through-the-thickness. A pulse-echo ultrasonic wave propagation imaging algorithm (PE-UWPI) is used for on-the-fly damage visualization of the structure. The presented system is very effective for high-speed, localized, non-contact, and non-destructive inspection of aerospace structures. The system is tested on an aluminum honeycomb sandwich with disbonds and a carbon fiber-reinforced plastic (CFRP) honeycomb sandwich with a layer overlap. Inspection is performed at a 10-kHz scanning speed that takes 16 seconds to scan a $100{\times}100mm^2$ area with a scan interval of 0.25 mm. Finally, a comparison is presented between angular-scanning and a linear-scanning-based pulse-echo UPI system. The results show that the proposed system can successfully visualize defects in the inspected specimens.

The Analysis of Pulse Wave Velocity of Jeju female divers (제주 해녀의 맥파전도속도 분석)

  • Lee, Han-Young
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.515-521
    • /
    • 2015
  • In this study, we tried to analyze arterial stiffness of Jeju female divers who diver into cold water without the assistance of oxygen. For this purpose we measured pulse wave velocity and ankle-brachial index of Jeju female divers and same aged females who didn't have any cardiovascular risk for comparing the vascular stiffness. The results were the following : First, the light-femoral pulse wave velocity of Jeju female divers was significantly lower than normal women of the same ages. Second, Jeju female divers's ABI showed higher tendency than normal same aged women. These result showed that Jeju female divers' body had been completed for adaptation to low temperature and high pressure water environment through a long-term immersion activities in old age, as well as due to higher physical activity levels of Jeju female divers peripheral vascular resistance was not reduced.

Case Study of the Anti-Cholesterol Effects on the Prescription of Red Onion (적색 양파 함유 식품의 항고지혈증 효능에 대한 임상사례 보고)

  • Kim, Gyeong-Cheol;Kim, Yi-Soon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.16 no.3
    • /
    • pp.1-10
    • /
    • 2012
  • Objectives: The purpose of this study is to observe clinically the anti-cholesterol effects on the prescription of red onion. Materials and methods: The subject of study were middle-aged people. We measured clinically physiological index, body composition, radial arterial pulse wave after 2 month by taking medicine (the prescription of red onion) Results: The study results were as follows. 1. Systolic and diastolic blood pressure of subjects were decreased significantly in the statistics. 2. Total cholesterol and low-density lipoprotein were decreased significantly after 2 month taking medicine. Triglyceride was decreased after 2 month but there was no significant difference and high density lipoprotein was increased after 2 month but there was no significant difference. 3. Waist-Hip ratio, body mass index and body fat percentage were decreased significantly in the statistics, after 2 month taking medicine. 4. HR was increased significantly in the statistics after 2 month but ESV and ECO were decreased signficantly in the statistics after 2 month taking medicine. 5. Pulse wave energy was increased after 2 month but there was no significant difference in the statistics. 6. RAI was decreased significantly in the statistics after 2 month taking medicine. Conclusion: The prescription of purple onion was showed significant change in physiological index, character of body composition, blood circulation index, pulse wave energy and RAI. Therefore it was showed the effect of anti-cholesterol blood circulation clinically. In the future, with diversified study on effect of prescription of purple onion, Oriental medicinal herbs will be used extensively.

Effects of folic acid supplementation on serum homocysteine levels, lipid profiles, and vascular parameters in post-menopausal Korean women with type 2 diabetes mellitus

  • Vijayakumar, Aswathy;Kim, Eun-kyung;Kim, Hyesook;Choi, Young Ju;Huh, Kap Bum;Chang, Namsoo
    • Nutrition Research and Practice
    • /
    • v.11 no.4
    • /
    • pp.327-333
    • /
    • 2017
  • BACKGROUND/OBJECTIVES: Complications of diabetes, such as cardiovascular disease, are associated with increased mortality among type 2 diabetes mellitus patients. Homocysteine has been recently identified as a predictor of cardiovascular disease-related complications in diabetes. We investigated whether or not supplementation with folic acid tablets can lower homocysteine levels and improve parameters related with vascular complications. SUBJECTS/METHODS: We conducted a non-randomized 8-week trial involving postmenopausal diabetic women (n = 25) supplemented with $800{\mu}g$ of folic acid ($400{\mu}g$ twice a day) daily. Subjects' serum levels of folate, homocysteine, and vitamin $B_{12}$ were measured, along with vascular function and brachial-ankle pulse wave velocity. RESULTS: Folic acid supplementation significantly increased serum folate levels (P < 0.0001), reduced homocysteine levels (P < 0.0001), and increased vitamin $B_{12}$ levels (P = 0.0063). There were significant decreases in low-density lipoprotein cholesterol levels as well as the ratios of low-density lipoprotein cholesterol to high-density lipoprotein cholesterol and total cholesterol to high-density lipoprotein cholesterol. Brachial-ankle pulse wave velocities were not altered by supplementation. Changes in serum vitamin $B_{12}$ after folic acid supplementation were negatively correlated with changes in brachial-ankle pulse wave velocity. CONCLUSIONS: In this study on postmenopausal Korean women with type 2 diabetes mellitus, folic acid supplementation reduced serum homocysteine levels, increased serum folate and vitamin $B_{12}$ levels, and lowered lipid parameters.

Computerized pulse diagnosis system (컴퓨터 맥진시스템)

  • Lee, Ho-Jae;Huh, Woong
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.4
    • /
    • pp.81-90
    • /
    • 1996
  • In this paper, we implemented a computerized pulse diagnosis system for the developement of pulse diagnosis algorithms and the generalization of the pulse diagnosis. The system consists of the hardware and software. The hardware detects pulse waves and inputs the waves into the computer system, while the software not only manages and analyzes the input pulse wave data but also privides the database. In order to clinically test the developed pulse diagnosis system, we applied the carotid-radial pulse diagnosis algorithm to the system. As the results, it is found that the genralizatio of the pulse diagnosis is possible.

  • PDF

Detection and interpretation of wan-maeck by the pulse diagnostic apparatus -on the pulse/respiration rate- (완맥(緩脈)의 동서의학적(東西醫學的) 해석 -맥율(脈率)을 중심으로-)

  • Park, Young-Bae;Kang, Sung-Keel;Kim, Chang-Hwan;Koh, Hyung-Kyun;Kim, Yong-Suk;Lee, Yun-Ho;Kim, Sung-Woon;Huh, Wung;Youn, Chung-Hwa
    • The Journal of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.143-156
    • /
    • 1997
  • This report was conducted to quantify the pulse/respiration ratio and set up the normal range of wan-maeck(緩脈). In order to objectify the pulse diagnosis and use as basic clinical index of Cold-Hot diagnosis, we developed the hardware and software for detection and interpretation of pulse/respiration ratio, pulse/expiration ratio, pulse/respiration ratio, inspiration time, expiration time, respiration frequency, respiration time, duration of one pulse and pulse and pulse rate per minute, The results were as follows; pulse/respiration ratio is $4.30{\pm}1.03$ times, pulse/respiration ratio is $1.60{\pm}0.32$ times, pulse/respiration ratio is $2.37{\pm}0.75$ times, inspiration time is $1.35{\pm}0.20$ sec, expiration time is $1.89{\pm}0.39$ sec, respiration frequency is $17.16{\pm}3.49$ times/min, total respiration time is $3.63{\pm}0.71$ sec, duration of a pulse is $0.86{\pm}0.15$ sec, pulse rate is $71.51{\pm}12.30$ times/min.

  • PDF

A Comparative Study on the Pulse Wave Variables and Sasang Constitution in Hypertension Patients and Healthy Subjects (고혈압 환자와 건강인의 맥상과 사상체질에 관한 연구)

  • Choi, Yong-Seok;Kim, Kyung-Yo;Hwang, Seung-Yeon;Choi, Chul-Won;Kim, Hyun-Hee;Joo, Jong-Cheon
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.2
    • /
    • pp.127-142
    • /
    • 2007
  • 1. Objectives We studied the characteristics of pulse wave variables in hypertensive patients and healthy subjects and would develope the program diagnosing Sasang Constitution. 2. Methods Healthy subjects and hypertensive patients were measured with pulse analyzer. In each of healthy and hypertensive group, means of pulse analyzer variables were compared among Constitution. On these bases of these results, decision tree composed of several rules were developed. 3. Results and Conclusions Decision tree with 72.13% accuracy were developed. (1) if h5(Cheok) < 2.325 & Wm/t(Cheok) < 0.238281 then class = Soeumin (2) if h5(Cheok) < 2.325 & Wm/t(Cheok) ${\ge}$ 0.238281 then class = Taeumin (3) if h5(Cheok) ${\ge}$ 2.325 & t1(Chon) ${\ge}$ 0.143 then class = Soyangin (4) if h5(Cheok) ${\ge}$ 2.325 & t1(Chon) < 0.143 & h3/h1(Cheok) ${\ge}$ 0.963601 then class = Soyangin (5) if h5(Cheok) ${\ge}$ 2.325 & t1(Chon) < 0.143 & h3/h1(Cheok) < 0.963601 & sum of pulse pressure(SPP) of Gwan ${\ge}$ 618 then class = Taeumin (6) if h5(Cheok) ${\ge}$ 2.325 & t1(Chon) < 0.143 & h3/h1(Cheok) < 0.963601 & sum of pulse pressure(SPP) of Gwan < 618 & t3(Chon) < 0.209 then class = Soeumin (7) if h5(Cheok) ${\ge}$ 2.325 & t1(Chon) < 0.143 & h3/h1(Cheok) < 0.936601 & sum of pulse pressure(SPP) of Gwan < 618 & t3(Chon) ${\ge}$ then class = Taeumin From above results, we concluded that pulse analyzer is useful instrument to decide Sasang Constitution.

  • PDF

Effects of Acupuncture Stimulation on the Radial artery's Pressure Pulse Wave in Healthy Young Participants: Protocol for a prospective, single-Arm, Exploratory, Clinical Study

  • Shin, Jae-Young;Ku, Boncho;Kim, Tae-Hun;Bae, Jang Han;Jun, Min-Ho;Lee, Jun-Hwan;Kim, Jaeuk U.
    • Journal of Pharmacopuncture
    • /
    • v.19 no.3
    • /
    • pp.197-206
    • /
    • 2016
  • Introduction: This study aims to investigate the effects of acupuncture stimulation on the radial artery's pressure pulse wave, along with various hemodynamic parameters, and to explore the possible underlying mechanism of pulse diagnosis in healthy participants in their twenties. Methods and analysis: This study is a prospective, single-arm, exploratory clinical study. A total of 25 healthy participants, without regard to gender, in their twenties will be recruited by physicians. Written informed consent will be obtained from all participants. The participants will receive acupuncture once at ST36 on both sides. The radial arterial pulse waves will be measured on the left arm of the subjects by using an applicable pulse tonometric device (KIOM-PAS). On the right arm (appearing twice), electrocardiogram (ECG), photoplethysmogram (PPG), respiration and cardiac output (CO) signals, will be measured using a physiological data acquisition system (Biopac module), while the velocity of blood flow, and the diameter and the depth of the blood vessel will be measured using an ultrasonogram machine on the right arm (appearing twice). All measurements will be conducted before, during, and after acupuncture. The primary outcome will be the spectral energy at high frequencies above 10 Hz ($SE_{10-30Hz}$) calculated from the KIOM-PAS device signal. Secondary outcomes will be various variables obtained from the KIOM-PAS device, ECG, PPG, impedance cardiography modules, and an ultrasonogram machine. Discussion: The results of this trial will provide information regarding the physiological and the hemodynamic mechanisms underlying acupuncture stimulation and clinical evidence for the influence of acupuncture on the pressure pulse wave in the radial artery. Ethics and dissemination: This study was approved by the Institutional Review Board (IRB) of Kyung Hee University's Oriental Medical Center, Seoul, Korea (KOMCIRB-150818-HR-030). The study findings will be published in peer-reviewed journals and presented at national and international conferences. Trial registration number: This trial was registered with the Clinical Research Information Service (CRIS) at the Korea National Institute of Health (NIH), Republic of Korea (KCT0001663), which is a registry in the World Health Organization's (WHO's) Registry Network.

Fast Measurement using Wave-Cutoff Method

  • Seo, Sang-Hun;Na, Byeong-Geun;Yu, Gwang-Ho;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.30-30
    • /
    • 2011
  • The wave-cutoff tool is a new diagnostic method to measure electron density and electron temperature. Most of the plasma diagnostic tools have the disadvantage that their application to processing plasma where toxic and reactive gases are used gives rise to many problems such as contamination, perturbation, precision of measurement, and so on. We can minimize these problems by using the wave-cutoff method. Here, we will present the results obtained through the development of the wave-cutoff diagnostic method. The frequency spectrum characteristics of the wave-cutoff probe will be obtained experimentally and analyzed through the microwave field simulation by using the CST-MW studio simulator. The plasma parameters are measured with the wave-cutoff method in various discharge conditions and its results will be compared with the results of Langmuir probe. Another disadvantage is that other diagnostic methods spend a long time (~ a few seconds) to measure plasma parameters. In this presentation, a fast measurement method will be also introduced. The wave-cutoff probe system consists of two antennas and a network analyzer. The network analyzer provides the transmission spectrum and the reflection spectrum by frequency sweeping. The plasma parameters such as electron density and electron temperature are obtained through these spectra. The frequency sweeping time, the time resolution of the wave-cutoff method, is about 1 second. A short pulse with a broad band spectrum of a few GHz is used with an oscilloscope to acquire the spectra data in a short time. The data acquisition time can be reduced with this method. Here, the plasma parameter measurement methods, Langmuir probe, pulsed wave-cutoff method and frequency sweeping wave-cutoff method, are compared. The measurement results are well matched. The real time resolution is less than 1 ?sec. The pulsed wave-cutoff technique is found to be very useful in the transient plasmas such as pulsed plasma and tokamak edge plasma.

  • PDF

Various Pulse Forming of Pulsed $CO_2$ laser using Multi-pulse Superposition Technique

  • Chung, Hyun-Ju;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.4
    • /
    • pp.127-132
    • /
    • 2001
  • We describe the pulse forming of pulsed $CO_2$laser using multi-pulse superposition technique. A various pulse length, high duty cycle pulse forming network(PFN) is constructed by time sequence. That is, this study shows a technology that makes it possible to make various pulse shapes by turning on SCRs of three PFN modules consecutively at a desirable delay time with the aid of PIC one-chip microprocessor. The power supply for this experiment consists of three PFN modules. Each PFN module uses a capacitor, a pulse forming inductor, a SCR, a High voltage pulse transformer, and a bridge rectifier on each transformer secondary. The PFN modules operate at low voltage and drive the primary of HV pulse transformer. The secondary of the transformer has a full-wave rectifier, which passes the pulse energy to the load in a continuous sequence. We investigated laser pulse shape and duration as various trigger time intervals of SCRs among three PFN modules. As a result, we can obtain laser beam with various pulse shapes and durations from about 250 $mutextrm{s}$ to 600 $mutextrm{s}$.

  • PDF