• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.026 seconds

A Design of Fire-Command Synchronous Satellite Pyrotechnic Circuit (점화 명령에 동조된 인공위성 파이로테크닉 회로 설계)

  • Koo, Ja Chun;Ra, Sung Woong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.81-92
    • /
    • 2013
  • The satellite includes many release mechanisms such as solar array deployment, antenna deployment, cover to protect contamination in scientific equipment, pyro value of the propulsion subsytem, and bypass device in Li-Ion cell module. A drive the initiators is a critical to the successful mission because the initiators of release mechanism driving by the pyrotechnic circuit is operated in single short. The pyrotechnic circuit has to provide switching network for safety. A typical switching network has defect consisting of high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit is required some form of power conditioning to reduce the peak power demanded from the bus if the initiators are to be fired from the main bus. This paper design a pyrotechnic circuit synchronized to the fire-command to activate the fire switch to overcome use high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit provides a current limited widow pulse for fire current synchronized to the fire-command to insure that fire switch will only carry the current but never switch it. The current limited widow pulse for fire current can be possible to use low current rating and light mass switch in switching network. The current limit function in the pyrotechnic circuit reduces supply voltage to initiator and provides the effect of power conditioning function to reduce peak bus power. The pyrotechnic circuit to apply satellite development on geostationary orbit is verified the function by test in development model.

A Study on Threshold Voltage Degradation by Loss Effect of Trapped Charge in IPD Layer for Program Saturation in a MLC NAND Flash Memory (멀티레벨 낸드 플래쉬 메모리 프로그램 포화 영역에서의 IPD 층에 트랩된 전하의 손실 효과에 의한 문턱 전압 저하 특성에 대한 연구)

  • Choi, Chae-Hyoung;Choi, Deuk-Sung;Jeong, Seung-Hyun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.3
    • /
    • pp.47-52
    • /
    • 2017
  • This research scrutinizes the data retention characteristics of the MLC NAND Flash Memory instigated by the loss effect of trapped charge when the memory is in the state of program saturation. It is attributed to the threshold voltage saturation phenomenon which engenders an interruption to the linear increase of the voltage in the memory cell. This phenomenon is occasioned by the outflow of the trapped charge from the floating gate to the control gate, which has been programmed by the ISPP (Incremental Step Pulse Programming), via Inter-Poly Dielectric (IPD). This study stipulates the significant degradation of thermal retention characteristics of threshold voltage in the saturation region in contrast to the ones in the linear region. Thus the current study evaluates the data retention characteristics of voltage after the program with a repeated reading test in various measurement conditions. The loss effect of trapped charge is found in the IPD layer located between the floating gate and the control gate especially in the nitride layer of the IPD. After the thermal stress, the trapped charge is de-trapped and displays the impediment of the characteristic of reliability. To increase the threshold saturation voltage in the NAND Flash Memory, the storage ability of the charge in the floating gate must be enhanced with a well-thought-out designing of the module in the IPD layer.

Suppression of Osteoporotic bone loss on the site to which low Intensity Ultrasound is Irradiated - In vivo test on BMD and Morphological Characteristics (저강도 초음파 조사 부위의 골 소실 억제 효과 -골 밀도 및 형태학적 특성 평가)

  • Ko, Chang-Yong;Seo, Dong-Hyun;Kim, Hyo-Seon;Kim, Han-Sung;Kim, Sang-Hee;Kim, Jin-Man;Kim, Ki-Won;Lim, Do-Hyung
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.49-55
    • /
    • 2009
  • Purpose : The aim of this study is to evaluate a possibility of clinical application for the effects of low intensity ultrasound stimulation (LIUS) in morphological characteristics (i.e., structure, bone mineral density) of bone on osteoporotic fracturesprevention. Materials and Methods : Eight virgin 14-week-old ICR mice (approximate weight 25g) were used and ovariectomized (OVX) to induce osteoporosis. Right tibia (US) for each mouse served as the LIUS (1.5MHz frequency, 1.0 kHz pulse repetition on frequency, $30mW/cm^2$ intensity, $200{\mu}s$ pulse length, and stimulation for 20 minutes a day and 5 days a week over a 6-week period). Left tibia (CON) for each mouse served as the non-stimulated controls. Structural parameters and bone mineral density ($g/cm^3$) on trabecular bone of tibiae were calculated and measured from images derived in-vivo micro computed tomography (micro-CT) at 0 week and after 6weeks. Results : The BV/TV and Tb.N in US group were significantly bigger than those in CON group. The Tb.Pf in US group, moreover, was significantly smaller than that in CON group (p<0.05).For the others structural parameters and BMD, however, there were no significant difference between US group and CON group (p>0.05). Conclusion : The LIUS might prevent bone loss and keep bone connectivity in osteoporotic bones. Therefore, the LIUS might prevent effectively the osteoporotic fractures in clinics.

Acquisition and Verification of Dynamic Compression Properties for SHPB of Woven Type CFRP (Woven Type CFRP의 SHPB에 대한 동적 압축 물성 획득 및 검증)

  • Park, Ki-hwan;Kim, Yeon-bok;Kim, Jeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.5
    • /
    • pp.363-372
    • /
    • 2020
  • Dynamic compressive material properties at high strain rates is essential for improving the reliability of finite element analysis in dynamic environments, such as high-speed collisions and high-speed forming. In general, the dynamic compressive material properties for high strain rates can be obtained through SHPB equipment. In this study, SHPB equipment was used to acquire the dynamic compressive material properties to cope with the collision analysis of Woven tpye CFRP material, which is being recently applied to unmanned aerial vehicles. It is also used as a pulse shaper to secure a constant strain rate for materials with elastic-brittle properties and to improve the reliability of experimental data. In the case of CFRP material, since the anisotropic material has different mechanical properties for each direction, experiments were carried out by fabricating thickness and in-plane specimens. As a result of the SHPB test, in-plane specimens had difficulty in securing data reproducibility and reliability due to fracture of the specimens before reaching a constant strain rate region, whereas in the thickness specimens, the stress consistency of the specimens was excellent. The data reliability is high and a constant strain rate range can be obtained. Through finite element analysis using LS-dyna, it was confirmed that the data measured from the pressure rod were excessively predicted by the deformation of the specimen and the pressure rod.

Effect of Various Divalent Ions on the Calcium Current of Adrenal Medullary Chromaffin Cells in the Rat

  • Kim, Jun;Leem, Chae-Hun;Kim, Sang-Jeong
    • The Korean Journal of Physiology
    • /
    • v.26 no.2
    • /
    • pp.113-122
    • /
    • 1992
  • It is well known that chromaffin cells of adrenal medulla secrete catecholamine in response to sympathetic nerve activation and the influx of $Ca^{2+}$ through the voltage dependent $Ca^{2+}$ channels (VDCC) in the cell membrane do a major role in this secretory process. In this study, we explored the effect of divalent cations on VDCC of rat chromaffin cells. Rat (Sprague-Dawley rat, 150-250 gm) chromaffin cells were isolated and cultured. Standard giga seal, whole cell recording techniques were employed to study $Ca^{2+}$ current with external and internal solutions that could effectively isolate VDCC currents $(NMG\;in\;external\;and\;TEA\;and\;Cs^{2+}\;in\;internal\;solution)$. The voltage dependence and the inactivation time course of VDCC in our cells were identical to those of bovine chromaffin cells. A persistent inward current was first activated by depolarizing step pulse from the holding potential (H.P.) of -80 mV to -40 mV, increased to maximum amplitude at around +10 mV, and became smaller with progressively higher depolarizing pulses to reverse at around +60 mV. The inactivation time constant $(\tau)$, fitted from the long duration test potential (2 sec) was $1295.2{\pm}126.8$ msec $(n=20,\;1\;day\;of\;culture,\;mean\;{\pm}S.E.M.)$ and the kinetic parameters were not altered along the culture duration. Nicardipine $(10\;{\mu}M)$ blocked the current almost completely. Among treated divalent cations such as $Cd^{2+},\;Co^{2+},\;Ni^{2+},\;Zn^{2+}\;and\;,Mn^{2+},\;Cd^{2+}$ was the most potent blocker on VDCC. When the depolarizing step pulse from -80 mV to 10 mV was applied, the equilibrium dissociation constant $(K_d)$ of $Cd^{2+}\;was\;39\;{\mu}M,\;K_d\;of\;Co^{2+}\;was\;100\;{\mu}M\;and\;K_d\;of\;Ni^{2+}];was];780{\mu}M.$ The principal findings of this study are as follows. First, the majority of $Ca^{2+}$ channels in rat chromaffin cells are well classified to L-type $Ca^{2+}$ channel in the view of kinetics and pharmacology. Second, all divalent cations tested could block the $Ca^{2+}$ current and the most potent blocker among the tested was $Cd^{2+}$.

  • PDF

The Effect of Body Positioning on Physiologic Index in Patients with Unilateral Lung Disease (편측성 폐질환 환자의 체위변경이 생리적 지표에 미치는 영향)

  • Cho, Jee Yeon;Lee, Hyang Yeon
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.1
    • /
    • pp.122-133
    • /
    • 2000
  • The purpose of this study was to identify the effect of body positioning on $PaO_2$, $SpO_2$, systolic blood pressure, diastolic blood pressure, pulse, and respiration(above all defined physiologic index), of patients with unilateral lung disease. The subjects for this study were eleven patients admitted to I.C.U. of K.H.M.C. with a diagnosis of unilateral lung disease confirmed by chest X-ray and the attending doctor, from January 30th. to April 20th. 1999. A quasi-experimental repeated-measures cross-over design was used to compare three body positions(semi-Fowler's, lateral decubitus with good lung dependent, and lateral decubitus with diseased lung dependent). Each subject spent 30 minutes in semi-Fowler's position and 2 hours in good lung dependent position and diseased lung dependent position. Starting in the semi-Fowler's position, then in the lateral position with the good lung dependent or the diseased lung dependent as assigned in random order. Thirty minutes after each positioning, arterial blood sample was analyzed. Measurements of all physiologic index were recorded at the specified intervals(0, 30, 60 90, and 120 minutes) in good lung dependent and diseased lung dependent position. Statistical comparison of $PaO_2$ value was done using the Wilcoxon Signed Rank Test, and Multivariate repeated-measures analysis of variance was performed to analyse the within-subject effect of two dependent position for 2 hours on the five dependent variables: (1) $PaO_2$ (2) $SpO_2$ (3) systolic blood pressure (4) diastolic blood pressure (5) pulse. The results obtained were as follows: 1. The $PaO_2$ value in the good lung dependent position was significantly higher than the $PaO_2$ value in the diseased lung dependent position(Z=-2.8451, p=.002). 2. The $PaO_2$ value in the good lung dependent position was significantly higher than the $PaO_2$ value in the semi-Fowler's position (Z=-2.6673, p=.003). 3. The difference between the $PaO_2$ value in the semi-Fowler's position and the $PaO_2$ value in the diseased lung dependent position was not significant(Z=-1.2448, p=.10). 4. There were no statistically significance in the trends of physiologic index in the good lung dependent position and the diseased lung dependent position. From the results, it may be concluded that the good lung dependent position is the most effective position for patients with unilateral lung disease that improve oxygenation. Identification of positioning over time may be need further studies.

  • PDF

The Physical and Mechanical Properties of No-Fines Lightweight Concrete Using Synthetic Lightweight Coarse Aggregate (인공경량조골재(人工輕量粗骨材)를 사용(使用)한 무세골재(無細骨材) 경량(輕量)콘크리트의 물리(物理)·가학적(加學的) 특성(特性))

  • Kim, Seong Wan;Min, Jeong Ki;Cho, Seung Seup;Sung, Chan Yong
    • Korean Journal of Agricultural Science
    • /
    • v.23 no.1
    • /
    • pp.39-50
    • /
    • 1996
  • The normal cement concrete is widely used material to build the construction recently, but it has a fault to increase the dead load on account of its unit weight is large compared with strength. So, many engineers are continuously searching for new materials of construction to provide greater performance at lower density. Many studies were carried out on the lightweight aggregate concrete in foreign country in the latter half of the 19th century, therefore lightweight aggregate concrete has been used successfully for many years for structural members. The main purpose of the work described in this paper were to establish its physical and mechanical properties of no-fines lightweight concrete using synthetic lightweight coarse aggregates. Test results are summarized as follows ; The water-cement ratio was shown less than 33% in use synthetic lightweight coarse aggregates, unit weights of synthetic lightweight concrete was shown less than $1,800kg/m^3$ and compressive strength was higher than $200kg/m^2$. And the pulse velocity was more than 3,000m/sec. The relationship of compressive strength between unit weight and pulse velocity was shown to be approximately linear.

  • PDF

Automatic On-Chip Glitch-Free Backup Clock Changing Method for MCU Clock Failure Protection in Unsafe I/O Pin Noisy Environment (안전하지 않은 I/O핀 노이즈 환경에서 MCU 클럭 보호를 위한 자동 온칩 글리치 프리 백업 클럭 변환 기법)

  • An, Joonghyun;Youn, Jiae;Cho, Jeonghun;Park, Daejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.99-108
    • /
    • 2015
  • The embedded microcontroller which is operated by the logic gates synchronized on the clock pulse, is gradually used as main controller of mission-critical systems. Severe electrical situations such as high voltage/frequency surge may cause malfunctioning of the clock source. The tolerant system operation is required against the various external electric noise and means the robust design technique is becoming more important issue in system clock failure problems. In this paper, we propose on-chip backup clock change architecture for the automatic clock failure detection. For the this, we adopt the edge detector, noise canceller logic and glitch-free clock changer circuit. The implemented edge detector unit detects the abnormal low-frequency of the clock source and the delay chain circuit of the clock pulse by the noise canceller can cancel out the glitch clock. The externally invalid clock source by detecting the emergency status will be switched to back-up clock source by glitch-free clock changer circuit. The proposed circuits are evaluated by Verilog simulation and the fabricated IC is validated by using test equipment electrical field radiation noise

Analysis on PD Pulse Distribution by Defects Depending on SF6 Pressure (SF6 압력에 따른 결함별 부분 방전 펄스의 분포 분석)

  • Kim, Sun-Jae;Jo, Hyang-Eun;Jeong, Gi-Woo;Kil, Gyung-Suk;Kim, Sung-Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.1
    • /
    • pp.40-45
    • /
    • 2015
  • Electrode systems: a protrusion on conductor (POC), a protrusion on enclosure (POE), a crack in epoxy plate and a free particle (FP) were fabricated to simulate insulation defects in a gas insulated switchgear (GIS). $SF_6$ gas was filled in the electrode systems by 3 bar and/or 5 bar, respectively. Partial discharge (PD) pulses were detected through a $50{\Omega}$ non-inductive resistor. A calibration test was carried out according to IEC 60270, and the sensitivity was 0.25 pC/mV. PD pulses were distributed in the phase of $50^{\circ}{\sim}135^{\circ}$ and over 95% of them existed in the phase of $55^{\circ}{\sim}120^{\circ}$ for the POC. PD pulses were distributed in the phase of $230^{\circ}{\sim}310^{\circ}$ and over 90% of them existed in phase of $220^{\circ}{\sim}300^{\circ}$ for the POE. PD pulses occurred in the phase of $40^{\circ}{\sim}60^{\circ}$ and $220^{\circ}{\sim}300^{\circ}$ for the crack, and pulse counts were 25% higher in negative polarity than in positive polarity. PD pulses were distributed in every phase unlike to other three electrode systems and the peak magnitude was measured at $118^{\circ}$ and $260^{\circ}$ for the FP. As described above, PD pulses were observed in positive polarity for the POC, in negative one for the POE, in both one for the crack and the FP. In conclusion, it is expected that the identification rate of defect type can be improved by considering the polarity ratio of PD pulses on the PRPDA method.

Safety and Efficacy of Submucosal Midazolam When Combined with Oral Chloral Hydrate, Hydroxyzine and Nitrous Oxide Sedation by using Houpt's Scale (Midazolam을 구강 점막 하로 병용 투여한 진정법의 안정성과 Houpt Scale을 이용한 진정효과에 대한 연구)

  • Park, Mi-Koung;Kim, Yun-Hee;Jung, Sang-Hyuk;Beak, Kwang-Woo
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.6 no.2 s.11
    • /
    • pp.103-112
    • /
    • 2006
  • Background: The purpose of this study was to compare the clinical safety and effect with and without additional submucosal midazolam to oral chloral hydrate and hydroxyzine when used for pediatric conscious sedation in a clinical dental environment. Methods: Thirty one cases of pediatric conscious sedations were performed in this study. Selection criteria included good health (ASA I), under 6 years old, 20 kg of body weight, uncooperative behavior and the need for sedation to receive dental treatment including anesthesia and restorative or surgical procedure for at least two teeth. In each visit, patients were randomly assigned into one of two groups; CH group: chloral hydrate (60 mg/kg), hydroxyzine (1 mg/kg), CH-M group: chloral hydrate (60 mg/kg). hydroxyzine (1 mg/kg) and submucoal midazolam (0.1 mg/kg). 50% nitrous oxide-oxygen was maintained during the sedation period Sedations were monitored using a pulse oximeter for estimating pulse rate (PR) and percutaneous oxygen saturation ($SpO_2$). Behavior response rated using Houpt's scale and need of restraint was assessed every 2 minutes through 30 minutes of operative procedure reviewing the videotape recording. Evaluation of overall behavior success was performed using modified overall behavior rate of Houpt's scale. Data was analyzed using t-test. Results: PR and $SpO_2$ for both groups remained within the normal values. The mean scores for sleep and movement of CH-M group were higher than those of CH group (P < 0.05). There were no significant difference in mean score for crying between two groups. The mean scores of overall behavior of CH-M group was higher than those of CH group (P < 0.01). Reinstraint of CH-M group was less required than that of CH group (P < 0.05). Conclusions: Oral chloral hydrate (60 mg/kg) and hydroxyzine (1 mg/kg) combined with submucosal injection of midazolam was safer and showed more improved sedation effect than oral chloral hydrate (60 mg/kg) and hydroxyzine (1 mg/kg) without midazolam for sedation of pediatric dental patients.

  • PDF