• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.031 seconds

Influence of Parasitic Parameters on Switching Characteristics and Layout Design Considerations of SiC MOSFETs

  • Qin, Haihong;Ma, Ceyu;Zhu, Ziyue;Yan, Yangguang
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1255-1267
    • /
    • 2018
  • Parasitic parameters have a larger influence on Silicon Carbide (SiC) devices with an increase of the switching frequency. This limits full utilization of the performance advantages of the low switching losses in high frequency applications. By combining a theoretical analysis with a experimental parametric study, a mathematic model considering the parasitic inductance and parasitic capacitance is developed for the basic switching circuit of a SiC MOSFET. The main factors affecting the switching characteristics are explored. Moreover, a fast-switching double pulse test platform is built to measure the individual influences of each parasitic parameters on the switching characteristics. In addition, guidelines are revealed through experimental results. Due to the limits of the practical layout in the high-speed switching circuits of SiC devices, the matching relations are developed and an optimized layout design method for the parasitic inductance is proposed under a constant length of the switching loop. The design criteria are concluded based on the impact of the parasitic parameters. This provides guidelines for layout design considerations of SiC-based high-speed switching circuits.

Fabrication and Test of Hundred ns, Hundred kV Pulse Power Supply (수백ns, 수백 kV 펄스전원공급장치 제작 및 시험)

  • Park, Soung-Soo;Heo, Hoon;Kim, Sung-Chul;Kim, Sang-Hee;Kim, Sung-Hwan;Park, Young-Jung;Choi, O-Rong;Nam, Sang-Hoon;Shin, J.W.;So, J.H.;Jang, W.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1364_1366
    • /
    • 2009
  • 고출력 펄스 전원으로 PFN Marx 펄스 전원공급장치를 설계 및 제작하였다. PFN Marx는 커패시터와 인덕터 그리고 스파크 갭과 전원을 공급하는 전원공급장치와 전류 인덕터로 구성하여 제작을 하였다. 여기에 사용하는 스파크 갭 스위치는 개스를 채우는 방식으로 개스의 압력을 조정하여 스위치의 스위칭 전압을 조정하여 준다. PFN Marx는 커패시터와 인덕터가 직병렬로 구성이 되며 펄스폭과 PFN의 임피던스를 결정하는 중요한 요소이다. PFN marx는 33단으로 구성을 하였으며 부하를 $100{\Omega}$으로 설계 및 시뮬레이션을 통하여 제작하였다. PFN Marx 펄스전원공급장치를 약 500 kV, 수백 ns까지 시험을 하였다. 본 논문에서는 PFN Marx 펄스전원장치의 설계 제작 및 시험에 대하여 고찰하고자 한다.

  • PDF

In-cylinder Spray Flow Characteristics in Direct-injection Gasoline Engine (직접 분사식 가솔린 엔진의 실린더 내 분무 유동 특성에 관한 연구)

  • 김진수;전문수;윤정의
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.6
    • /
    • pp.51-59
    • /
    • 2000
  • In-cylinder spray flow motion plays an important in the adjustment of mixture preparation with a fundamental spray characteristics and in-cylinder flow field well in direct-injection gasoline engine. In this study, the fundamental spray characteristics such as mean drop size, velocity distribution, spray angle were measured and in-cylinder spray flow motion was visualized in order to optimize intake port, piston top land and combustion chamber shapes in the development stage of mass-produced G야 engine. For these experiments, the PDPA measurements and Mie scattering technique were used for detailed spray characteristics and in-cylinder spray motions were obtained by use of ICCD camera through the single-cylinder optical engine. From the experimental results, the test injector shows a good low-end linearity between the dynamic flow and fuel injection pulse width and the fuel spray of 20mm or less in SMD with good spray symmetry. In addition, the in-cylinder tumble flow has more effect on the homogeneous mixture formation than that of in-cylinder swirl flow at early injection mode and the in-cylinder swirl flow plays a better role of stratified mixture preparation than tumble flow at late injection mode.

  • PDF

The effect of sucrose on infants during a painful procedure

  • Joung, Kyoung-Hwa;Cho, Soo-Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.8
    • /
    • pp.790-794
    • /
    • 2010
  • Purpose: The purpose of this study was to test the efficacy of treating the pain among newborn infants associated with a medical procedure with sucrose with regard to overall physiological and behavioral stability. Methods: 103 newborn infants were enrolled in this study. The control group (n=63) did not receive any treatment. The experimental group (n=40) received 2 mL of 24% sucrose solution two minutes before a routine heel stick. The pain was assessed by measurements of physiological changes [e.g. pulse rate, oxygen saturation, salivary cortisol (hydrocortisone)] and behavioral changes [e.g. crying time, and the neonatal infant pain scale (NIPS) for neonates]. Results: There were no differences among the groups with respect to physiological changes associated with the pain from the procedure. However, there were significant group differences in behavioral changes to the pain. In the control group, the median crying time was 13 seconds, while in the experimental group, the median crying time was 3.5 seconds ($P$=.000). In the control group the median NIPS score was 4, while in the experimental group the median NIPS score was 2 ($P$=.000). Conclusions: These findings suggest that sucrose can be an effective method for the management of stress responses in infants with regard to behavior. However, this treatment had no significant physiological effects.

Response Analysis of the NE213-PSD System for Neutron Energy Spectreum Measurement (중성자 에너지 측정을 위한 NE213-PSD 장치의 감응 분석)

  • Lee, Kyung-Ju
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.367-372
    • /
    • 1992
  • In order to measure the energy spectrum of a radioactive neutron source, the pulse shape discrimination (PSD) system with organic scintillator, NE-213, was characterized by using some of the gamma ray sources and neutron source, Am-Be. The figure of merit of the rise time spectrum of AmBe source measured by this system was about 1.13. This value agrees well with the value of 1.3 which is measured for monoenergetic source, $^{12}C(d,\;n)^{13}N$. The results of present experiment for performance test of NE213-PSD system will provide the useful technique to measure the spectrum of neutron-gamma mixed field and to establish the neutron energy spectrum and flux density standards.

  • PDF

A Development of Ultrasonic Defect Analysis Program for Composite Motor Case (복합재 연소관의 초음파 결함 분석 프로그램 개발)

  • Kim, Dong-Ryun;Lim, Soo-Yong;Chung, Sang-Ki;Lee, Kyung-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.393-399
    • /
    • 2011
  • A defect analysis program of the composite motor case was developed to apply the ultrasonic signal processing method on basis of the ultrasonic pulse-echo method and the defects of FRP delamination and FRP/Rubber disbond in the composite motor case could be quantitatively measured. The defects detected in the composite motor case were in agreement with the results measured with the computed tomography and video microscope. This paper was described about the development process of the defect analysis program to convert the ultrasonic test data into the C-Scan image.

  • PDF

A Clinical Study of Succinylcholine-Atracurium for Cesarian Section (제왕절개환자에 있어서 Succinylcholine-Atracurium의 임상적 고찰)

  • Park, Dae-Pal
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.49-51
    • /
    • 1986
  • Atracurium was used in 10 parturients undergoing elective cesarian section under general Anesthesia. An initial bolus of 0.4 mg/kg of the atracurium was injected after recovery from succinylcholine block. Complete neuromuscular block resulted in all cases. Muscular relaxation was maintained by incremental dose of 0.2mg/kg of atracurium. Administration of atracurium did not cause significant change in blood pressure, pulse rate and infants Apgar score. The residual neuromuscular block could be antagonized at the end of the procedure by mixture of 0.005mg/kg glycopyrrolate and 0.03 mg/kg of neostigmine. In all parturients, antagonism was adequate as evidenced by respiratory response and head lift test. Atracurium may be advantageous in parturients undergoing cesarian section under general anesthesia cause it maintained cardiovascular stability, is non-cumulative, is readily antagonized by neostigmine and has no deleterious effect on the newborn.

  • PDF

Voltage Source Equipment for the Grid Fault Testing and Analysis of Total Harmonic Distortion According to PWM Methods

  • Gwon, Jin-Su;Kim, Chun-Sung;Kang, Dae-Wook;Park, Jung-Woo;Kim, Sungshin
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1081-1092
    • /
    • 2014
  • Renewable energy is being spotlighted as the electric power generating source for the next generation. Due to an increase in renewable energy systems in the grid system, their impact on the grid has become non-negligible. Thus, many countries in the world, including Europe, present their own grid codes for grid power conversion devices. In order to experiment with these grid codes, grid fault test equipment is required. This paper proposes both equipment and a control method, which are constructed with a 7-level cascaded H-bridge converter, that are capable of generating various grid faults. In addition, the Pulse Width Modulation (PWM) method for multilevel converters is compared and analyzed. The proposed structure, the control method, and the PWM method are verified through simulation and experimental results.

Ultrasonographic Resistive Index of the Interlobar Renal Artery in Renal Failure Induced by Ochratoxin A and Citrinin Toxicosis in Dogs (Ochratoxin-A 및 Citrinin 중독 신부전 개에서 신장엽간동맥 혈관저항지수에 대한 도플러초음파 평가)

  • Bae, Jun-Woo;Seong, Yun-Sang;Oh, Tae-Ho;Jang, Kwang-Ho;Lee, Keun-Woo;Eom, Ki-Dong
    • Journal of Veterinary Clinics
    • /
    • v.23 no.4
    • /
    • pp.427-431
    • /
    • 2006
  • Pulse Doppler ultrasonographic evaluation was performed to investigate the resistive index (RI) of the Interlobar renal artery in 17 dogs (32 kidneys) which were diagnosed with an acute renal failure caused by ochratoxin-A and citrinin contaminated commercial diet. RI was investigated in 7 normal beagle dogs and recovered patients. The mean of RI was resulted as $0.69{\pm}0.04$ in normal dog, however, significantly (p<0.001) increased as $0.76{\pm}0.05$ in renal failure dog. But RI had no relationship with the results of blood chemistry, urine analysis, and excretory urographic image quality. From these results, even though the results of the renal function test were within a normal reference range, it was considered that RI index is more reliable to represent a damaged renal parenchyma, and may have the potential to be a useful clinical tool in monitoring of the renal function.

A Novel Control Algorithm of a Three-phase PWM Inverter with LC Filter (정현파 출력 필터를 가지는 3상 PWM 인버터 제어 기법)

  • Kim, Kwang-Seob;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.239-246
    • /
    • 2015
  • A novel control method of a three-phase PWM inverter with LC filter is proposed. The transfer function of LC filter is the same as that of second-order low pass filter(LPF), which has a zero damping ratio. A simple method of implementing second-order LPF with damping ratio is to add a resistor in an LC circuit. However, in a real power system, adopting damping resistors is impractical because it results in losses proportional to the square of the current flowing through the resistors. Instead of inserting resistors, the proposed control strategy utilizes the measured capacitor voltages to control the oscillation of LC circuit. The overall transfer function of the proposed method is the same as a second-order LPF, and its damping ratio is controllable via control variables. The current controller can have overshoots caused by LC filter. Improved current controller is implemented by an equivalent second-order of LC filter. A 7.5 kVA PWM converter and a PWM inverter with a 5.5 kW induction motor are set up to verify the proposed control algorithm. Test waveforms are also presented to verify the proposed LC filter control algorithm.