• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.034 seconds

A Study on L.V.I. Diagnosis Field Application of Transformer Winding Deformation (변압기 권선변형 L.V.I. 진단 실적용을 위한 연구)

  • Cho, Kook-Hee;Kang, Dong-Sik;Kim, Kwang-Hwa;Kweon, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1638-1640
    • /
    • 1998
  • We describe the possibility of field application and the diagnosis method of winding deformation in the power transformers using L.V.I. test system. Any winding deformation will result in a change of capacitance between winding parts and passibly some change in the winding inductance. These changes will then result in a change in the responce to the applied pulse in both the magnitude and period of the resulting oscillations. And we discuss with respect to test result of model transformer and commercial transformer, appear good results with application possibility in field.

  • PDF

Load Simulator with Power-Recovery Capability Based on Voltage Source Converter-Inverter Set (전력회수 능력을 갖는 전압원 컨버터-인버터 세트로 구성된 부하모의장치)

  • Bae B.Y.;Han B.M.
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.76-80
    • /
    • 2004
  • This paper describes a load simulator with power-recovery capability, which is based on the voltage source converter-inverter set. The load simulator described in this paper can save the electric energy that should be consumed to test the operation and performance of the distributed generation system and the power quality compensator. The load simulator consists of a converter-inverter set with a DSP controller for system control and PWM pulse generation. The converter operates as a universal load to model the linear load and the non-linear load, while the inverter feed the energy back to the power source with harmonic compensation. The load simulator can be widely used in the lab to test the performance of the distributed generation system and the power quality compensator.

  • PDF

Wideband Lamb wave analysis based on continuous wavelet transform

  • Shi, Lihua;Wang, Xinwei;Li, Gang;Zhang, Lingyan
    • Smart Structures and Systems
    • /
    • v.1 no.3
    • /
    • pp.257-266
    • /
    • 2005
  • In Lamb wave detection of damages in smart structures, the excitation pulse is usually designed as a narrow band burst wave for the convenience of analysis and recognition. However, the wideband excitation can excite more modes in plate/shell structure and thus provides extra information for changes of the structure. This paper presents a method that can extract information in wideband Lamb wave signals. By transforming the detected signals into various sub-frequency band, the measured signal can be converted to its equivalences of narrow band excitations, therefore, the information in different frequency bands can be acquired from a single test and in the same time the complicity of wideband signal can be simplified. Some test results are provided to verify this method.

A Study on the Determination of In-Situ Concrete Strength by Combined Nondestructive Testing Method (조합법에 의한 현장 콘크리트 강도의 비파괴 측정에 관한 연구)

  • 임선택;김창환;김영진;정한중
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.04a
    • /
    • pp.114-119
    • /
    • 1992
  • The main disadvantages of destructive testing methods are the delay in obtaining test results, the relatively high cost of testing, and the lack of reproducibility in the test results. As a result, nondestructive testing methods are generally used. There are three objectives in this paper. The first is to determine the equations of the compressive strength of concrete estimated by Schmidt hammer technique, ultrasonic pulse velocity method and combined method respectively in laboratory. The second is to determine the correction factors according to the concrete age which affects most in evaluating the compressive strength of in-situ concrete. The third is to examine the applicability of the equations to evaluation of the compressive strength of in-situ concrete structures.

  • PDF

A Study on Gate Trigger Current of SCR (SCR 게이트 전류의 변화특성에 관한 연구)

  • Seong, Houng-Su;Won, Hak-Jai;Han, Seung-Mun;Ha, Jeong-Hoon;Park, Ho-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1333-1335
    • /
    • 2000
  • In order to turn on the SCR gate, trigger signal source have to provide appropriate gate current and voltage under the gate rating based on the characteristic of SCR, the nature of load and power. It will be essential design factors such as trigger source impedance, trigger signal occurring, signal time width and turn off conditions. Also minimum gate trigger current is changed with the deterioration of SCR. SCR, which is needed large gate trigger current absolutely, is very important for SCR characteristic test because it causes unstable output in the misfile or makes a trouble to pulse trigger circuits. This paper shows scheme to test the performance of SCR with the precision analyzing mechanism and the changing trend of minimum gate current under the trigger conditions.

  • PDF

Investigation on Adhesive Properties depending on the Environmental Variation of the Steel Plate Adhesive Strengthening Method by the Epoxy Resin (에폭시 수지 접착 강판보강공법의 환경 변화에 따른 부착 특성 검토)

  • Han, Cheon-Goo;Byun, Hang-Yong;Park, Yong-Kyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.3
    • /
    • pp.107-113
    • /
    • 2007
  • This study is to investigate adhesive properties depending on the temperature, humidity, and freeze-thraw of the Steel plate adhesive strengthening method by the epoxy resin. The results are summarized as following. For the temperature variation, the debonding failure appear only after 1 cycle of temperature varoation because the coefficient of thermal expansion of the epoxy resin is comparatively large, and the bonding strength is decreased. The deformation properties and ultrasonic pulse velocity on each materials are similar until 4 cycles on the dry and moisture test. As the freeze-thraw test, the epoxy resin is degraded easily subjected to freeze-thaw cycle, comparatively easy, so the debonding failure may occur in short term because of the freeze-thaw repeatition.p

Quench characteristics of stainless steel laminated DyBCO coated conductor (스테인레스강 라미네이션된 DyBCO 초전도 선재의 퀜치 특성)

  • Dixit Manglesh;Kim Tae Hyung;Oh Sang Soo;Song Kyu Jeong;Kim Ho Min;Park Kwon Bae
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.1-4
    • /
    • 2005
  • As high temperature superconductor applications became a reality due to increase in coated conductor performance, it is important to understand their stability behavior to design safe electrical power systems. Coated conductors can be stabilized with different metals and alloys for different types of application, to yield excellent electrical, thermal and mechanical performance. We have experimentally studied the dependence of quench and recovery characteristics of stainless steel stabilized coated conductors on the amplitude of current and duration time. Stability test of 3cm long sample were performed in a liquid nitrogen bath cooling condition by applying a short period over current pulses for 50 and 100ms, with amplitude up to ~6 times the critical current. The transport current that flows before and after the current pulse was fixed at about ~80-85% critical current. We analyzed the quench and recovery phenomena of the test sample using the current voltage characteristic.

Load Simulator with Power-Recovery Capability Based on Voltage Source Converter-Inverter Set (전력회수 능력을 갖는 전압원 컨버터-인버터 세트로 구성 된 부하모의 장치)

  • Bae Byung-Yeol;Han Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.4
    • /
    • pp.181-187
    • /
    • 2005
  • This paper describes a load simulator with power-recovery capability, which is based on the voltage source converter-inverter set. The load simulator described in this paper can save the electric energy that should be consumed to test the operation and performance of the distributed generation system and the power quality compensator. The load simulator consists of a converter-inverter set with a DSP controller for system control and PWM pulse generation. The converter operates as a universal load to model the linear load and the non-linear load, while the inverter feed the energy back to the power source with harmonic compensation. The load simulator can be widely used in the lab to test the performance of the distributed generation system and the power quality compensator.

Design of 1500V solar inverter stack beyond megawatt in NPC1 topology

  • Hao, Xin;Ma, Kwok-Wai;Zhao, Jia;Sun, Xin-Yu
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.7-11
    • /
    • 2017
  • This paper describes a design concept of NPC1 power stack for 1500VDC megawatt level solar inverter. This stack uses three latest half-bridge IGBT modules with highest power density and operation junction temperature, which enable realization of power level beyond 1MW without paralleling. Critical design concept on loop inductance is explained. Dynamic characteristics are verified by double-pulse test. Thermal characteristics and output power limits are verified by thermal test. Temperature-sensitive component on PCB as output power constraint is identified. Different PCB repositioning solutions are tested to give the overall output power thermal derating curves, which enable output power of 1.15MW at $T_A=55^{\circ}C$ with $15^{\circ}C$ thermal margin. The power stack characteristic and performance change under different thermal environment is further analyzed.

  • PDF

Partial Discharge Measuring System of Mold Transformer (몰드변압기의 부분방전 측정 시스템)

  • Kang, Dong-Sik;Sun, Jong-Ho;Lim, Tae-Hoon;Hwang, Don-Ha;Kim, Yong-Joo;Kweon, Dong-Jin;Oeu, Soo-Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1891-1893
    • /
    • 2003
  • In order to development of diagnosis system for mold transformer, partial discharge measurement technique is recommended the best effective method for the evaluation of insulation condition. However, this technique was not applied to mold transformer yet. The purpose of this paper is to describe the method of partial discharge measurement for mold transformer. As we reviewed on-line test technique, sensor, transducer of pulse signal processing, set-up of test circuit for loading back device and now testing.

  • PDF