• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.022 seconds

Analysis of Solar Simulator's Uncertainty Factor for Maximum Output Power Test of Photovoltaic Module (PV모듈의 발전성능시험을 위한 Solar Simulator의 측정불확도 요인 분석)

  • Kang, Gi-Hwan;Kim, Kyung-Soo;Park, Chi-Hong;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.39-45
    • /
    • 2007
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.36W$ with 95% confidence level for 125W PV module(KD-5125).

Compressive Strength Control of High Strength Concrete Using Transparent Joint Separation Test Body (투명접합분리 시험체를 활용한 고강도 콘크리트의 강도관리에 관한연구)

  • Ki, Jun-Do;Jung, Kwang-Sik;Kim, Hak-Young;Kim, Kwang-Ki;Lee, Young-Do;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.49-52
    • /
    • 2009
  • This paper aims to evaluate hydration and intensity property of different kind of members and intensity in order to evaluate compressive strength of structural concrete using Joint Separation Test Body(JSTB). In fact it is difficult to test and evaluate already have constructed member. In this case, common method used by construction engineer is that ; Schmidt rebound hammer test, Ultrasonic pulse test, Method of using test specimen previously cast. However, these method to control the structural intensity involve many problem and impossibility to adapt construction. 80, this paper proposes advance an opinion which have proper to examine intensity. has also aims to examine its validity and the plan to make similar environment with structural concrete and joint separation test body in order to verify efficiency assessment and on-site application.

  • PDF

Effect of Horticultural Therapy on Anger Control of the Primary Caregivers for Dementia Patients (원예치료가 치매 환자 주 부양자의 분노조절에 미치는 영향)

  • Kyung-Nam Park;Gye-yeong Heo
    • Journal of Environmental Science International
    • /
    • v.32 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • In this study, a horticultural therapy program was performed by employing the anger experienced by people during daily life activities in the emotion regulation strategy-based program to identify the influence of the horticultural program on anger control in the caregivers for patients with dementia. To measure this influence, two tools were used: a self-administered questionnaire survey, which is a subjective test, and an instrumental test, which can measure the physical index that detects the physical changes through anger. For the preliminary test, depression, stress, self-esteem, anxiety, and anger state-characteristic were tested using the self-administered questionnaire. For the follow-up test, the self-administered survey and the test using the physical index were performed in a manner similar to that of the preliminary test. The self-administered questionnaire comprised questions suitable to this study and considered the age, education level, and economic aspect of the subjects. The test results indicated that the experimental group subjected to the emotion regulation strategy-based horticultural therapy showed very significant reduction in depression and anger and significant reduction in stress, self-esteem, and anxiety. In the physical index test, the systolic and diastolic blood pressures were reduced, and the pulse rate and respiration rate reduced before and after the therapy, thus, proving the effectiveness of the therapy in anger control.

Reliability Evaluation of Compressive Strength of Reinforced Concrete Members (철근 콘크리트 구조 부재의 압축강도 추정 신뢰도 평가)

  • Hong, Seong-Uk;Park, Chan-Woo;Lee, Yong-Taeg;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.6
    • /
    • pp.132-140
    • /
    • 2019
  • In this study, a specimen composed of columns, walls, beams, and slabs was fabricated to investigate the estimated reliability using nondestructive test method for the location of structural members of reinforced concrete single layer structures. And for accurate analysis in the comparison process with the existing estimation formula, we try to analyze the reliability through statistical approach by using error rate comparison and Confidence interval estimation. As a result, The average error rate of the core test was 18.8% compared with the result of estimating the compressive strength using the ultrasonic pulse velocity method. The average error rate of the core test results compared with the result of estimating the compressive strength using the rebound hardness method was 20.1%, confirming the field applicability. it is judged that the reliability of the compressive strength estimation can be derived from the wall member to make a quick and efficient structure safety diagnosis using the ultrasonic pulse velocity method. In addition, it is judged that the reliability of the compressive strength estimation can be derived from the beam member to make a quick and efficient structure safety diagnosis using the rebound hardness method.

The Effect of Foot Massage on Post operative Pain in Patients Following Abdominal Surgery (복부수술 환자의 수술후 통증에 미치는 발마사지의 효과)

  • Kim, Jin-Hee;Park, Kyung-Sook
    • Korean Journal of Adult Nursing
    • /
    • v.14 no.1
    • /
    • pp.34-43
    • /
    • 2002
  • More and more non-injured operations are being implemented these days, thanks to the development of medical technology. Still, however, most operations leave direct scars on patient' bodies, as well as accompanying pain. The massage as an independent nursing intervention can stimulate the circulation of the blood of tissue and muscle and increase the relationship between a patient and a nurse. The purpose of this study is to investigate the effect of foot massage on pain in post abdominal operative patients. The nonequivalent control group, pre-post test design is used for this study. From July 7, 2000 to February 20, 2001, the 40 patients who were operated under general anesthesia in a university hospital in Seoul were studied. They were divided into two groups ; 20 patients were part of the experimental group, and the others, in the control group. In order to evaluate the effect of foot massage, severity of pain was checked with the VAS (Visual Analog Scale) and also each patients' vital signs were measured with pulse rate, systolic blood pressure and diastolic blood pressure. The collected datas were processed by SAS version 6.12 program and analyzed by the Chi-square, Fisher's exact test, t-test and repeated measures ANOVA. The results of this study were as follows. 1. The severity of pain decreased significantly in the experimental group as compared to the control group following foot massage (t=-3.317, p= .002). 2. Measured vital signs in the experimental group had more reduction of that than in the control group following foot massage. - The pulse rate in the experimental group was lower than that in the control group following foot massage (F=7.73, p=.008). - The systolic blood pressure in the experimental group was lower than that in the control group following foot massage (F=25.75, p=.000). - The diastolic blood pressure in the experimental group was lower than that in the control group following foot massage (F=15.27, p=.000). In conclusion, foot massage is an effective dependent nursing intervention for pain control of post abdominal operative patients.

  • PDF

Vacuum Characteristics of KSTAR ICRF Antenna during RF Operation (고주파 인가시의 KSTAR ICRF 안테나의 진공특성)

  • Bae, Young-Dug;Kwak, Jong-Gu;Hong, Bong-Geon
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.314-324
    • /
    • 2006
  • The vacuum characteristics of the KSTAR ICRF antenna were experimentally investigated. The fabricated antenna was installed in the RF Test Chamber(RFTC) which has a vacuum system with an effective pumping speed of 1015 l/s. The time variations of RFTC pressure, total gas load and ultimate pressure were measured before the RF test. RF conditioning effect was studied by repeating RF pulses at low power level. A time variation of the RFTC pressure was measured during a RF power was applied to the antenna. Threshold pressure at which a RF breakdown occurs was investigated. Whenever the pressure was higher than $10^{-4}$ mbar, the RF breakdown occurred. During a long pulse testing, the temperature of the antenna and RFTC pressure were measured to investigate long pulse limitation of the maximum available voltage without any cooling, which were compared with testing results with a water cooling of the antenna.

Pulse-mode Response Characteristics of a Small LRE for the Precise 3-axes Control of Flight Attitude in SLV (우주발사체의 비행자세 3축 정밀제어를 위한 소형 액체로켓엔진의 펄스모드 응답특성)

  • Jung, Hun;Kim, Jong Hyun;Kim, Jeong Soo;Bae, Dae Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • A liquid-monopropellant hydrazine thruster has several outstanding advantages such as relatively-simple structure, long/stable propellant storability, clean exhaust products, and so on. Therefore hydrazine thruster has such a wide application as orbit and attitude control system (ACS) for space vehicles. A hydrazine thruster with the medium-level thrust to be used in the ACS of space launch vehicles (SLV) has been developed, and its ground firing test result is presented in terms of thrust, impulse bit, temperature, and chamber pressure. It is verified through the performance test that the response and repeatability of thrust are very excellent, and the thrust efficiencies compared to its ideal requirement are larger than 93%.

Estimation of the Effective Hydraulic Conductivity in the Granite Area as an Equivalent Continuum Medium (등연속체매질로서의 화강암지역의 유효수리전도도 산출)

  • 김경수;김천수;배대석
    • The Journal of Engineering Geology
    • /
    • v.12 no.3
    • /
    • pp.319-332
    • /
    • 2002
  • This study is focused on the characterization of an effective hydraulic conductivity in each hydrogeologic unit assumed as an equivalent continuum medium in the granitic area. Four boreholes of 3" diameter were installed and a Multi-packer system was facilitated in the selected borehole. Various in-situ tests including the fracture logging, constant injection and fall-off tests, slug and pulse tests were carried out. A hydrogeologic unit was defined into the upper and lower zones based on the variation of fracture properties and hydraulic conductivities. The difference of the result obtained by the various hydraulic tests and the effective characterization techniques on rock mass permeability are also discussed. The effective hydraulic conductivity of the upper unit was measured by two times(5.27E-10 m/s~7.57E-10 m/s) that of the lower unit(2.45E-10 m/s~6.81E-10 m/s)through the constant injection and fall-off tests.

Design of a Bounded-wave EMP Simulator Antenna (Bounded-wave EMP Simulator 안테나의 설계)

  • Sun, Da-Young;Choi, Hak-Keun;Lim, Seong-Bin;Jang, Jae-Woong;Kim, Tae-Yoon;Choi, Geun-Kyung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.5
    • /
    • pp.87-93
    • /
    • 2011
  • A threat of the EMP(Electromagnetic Pulse) is recently increasing, so the development of electromagnetic security technology against the EMP is needed. However, the state of the domestic electromagnetic security technology against the EMP is lower level than the foreign. In this paper, the bounded-wave EMP simulator antenna for the development of electromagnetic security technology against a threat of the EMP is designed. The structure of the designed antenna is from a sort of the basic form of the bounded-wave EMP simulator such as a parallel-plate simulator for testing EMP immunity performance within the EUT(Equipment Under Test). The design processes of the designed simulator is including wave launcher, transmission line and termination taper. In the working volume of the designed antenna, the test object within 30 cm is forming predominant TEM field, so it is confirmed that the designed EMP simulator antenna can be used as the EMP simulator.

A Study of the Difference of Vital Sign by Stress Reaction (스트레스 반응으로 나타나는 활력증상 변화에 대한 실증적연구)

  • 김희승;한윤복;김명자;노유자
    • Journal of Korean Academy of Nursing
    • /
    • v.17 no.2
    • /
    • pp.137-144
    • /
    • 1987
  • The main purpose of this study was to examine the validity of the vital sign as an instrument of stress reaction measurement. From July to August 1986, stress reaction was evaluated by the difference of endoscopic vital sign on 93 G-I troubled out-patients who underwent endoscopy for the first time and did not have any evidence of cardiovascular disease. The data were analysed by x$^2$-test, Paired . t-test, ANCOVA and Multiple Comparison Test. The result of study were as follows: 1. The frequency of gastric disease was differed by the family type, and the mobility of gastritis and gastric cancer were more increased in nuclear family than in large family (p=0.019). 2. In a comparison of before with after 5 minutes endoscopic vital sign, and a Pulse rate (P=0.0001), respiration rate (p=0.0001), systolic blood pressure (p=0.0002) and diastolic blood Pressure (P=0.006) were significantly increased after 5minutes by endoscopy in contrast with before 5minutes. 3. The control of before 5 minutes of endoscopic vital sign, after 5 minutes of endoscopic systolic (p=0.024) and diastolic blood pressure (p=0.0146) were more elevated in biopsyed group than in non-biopsyed, group. And after 5minutes of endoscopic respiration rate was more increased in gastric cancer than in gastritis (p=0.0406) or gastric ulcer (p=0.0073). And after 5 minutes of endoscopic systolic blood pressure was elevated over 50years old men (P=0.0238). In short, the increase of a pulse rate af ter 5 minutes of endoscopy was not influenced by general characteristics of samples in this experiment. And systolic blood pressure over 50years old men must be considered of physiological hypertension.

  • PDF