Abstract
The vacuum characteristics of the KSTAR ICRF antenna were experimentally investigated. The fabricated antenna was installed in the RF Test Chamber(RFTC) which has a vacuum system with an effective pumping speed of 1015 l/s. The time variations of RFTC pressure, total gas load and ultimate pressure were measured before the RF test. RF conditioning effect was studied by repeating RF pulses at low power level. A time variation of the RFTC pressure was measured during a RF power was applied to the antenna. Threshold pressure at which a RF breakdown occurs was investigated. Whenever the pressure was higher than $10^{-4}$ mbar, the RF breakdown occurred. During a long pulse testing, the temperature of the antenna and RFTC pressure were measured to investigate long pulse limitation of the maximum available voltage without any cooling, which were compared with testing results with a water cooling of the antenna.
KSTAR ICRF 안테나의 진공특성을 실험적으로 조사하였다. 제작된 안테나를 총 유효배기속도 1015 l/s의 진공펌프가 장착된 시험용 진공용기에 설치하였으며, 고주파 시험하기 전에 시간에 따른 압력 변화, 총기체 부하, 도달 진공도 등을 측정하였다. 낮은 출력의 고주파를 반복적으로 인가함으로서 세정 효과를 확인하였다. 안테나에 고주파를 인가하여 시험하는 동안 진공도 변화를 측정하였으며, 압력 상승에 의해 방전이 유발되는 한계 압력을 조사하였다. 본 안테나의 경우 고주파 인가 중에 진공용기의 압력이 $10^{-4}$ mbar 이상이 되면 방전이 일어났다. 장펄스 시험에서 안테나의 온도와 시험용 진공용기의 압력을 측정하여 안테나를 냉각하지 않은 상태에서 운전이 가능한 전압을 조사하였으며, 냉각했을 때의 결과와 비교하였다.