• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.028 seconds

Combustion Stability Rating Test of Liquid Rocket Engine Thrust Chamber (액체로켓엔진 연소기 연소안정성 평가시험)

  • Ahn, Kyubok;Kim, Jong-Gyu;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.2
    • /
    • pp.60-66
    • /
    • 2014
  • As a evaluation method of combustion stability in a liquid rocket engine thrust chamber, external disturbance devices are used. In the paper, the study on pulse-gun ignition tests for a combustion stability rating test of a thrust chamber was performed. Charging volume of pulse-guns was determined by confirming the intensities of the pressure waves from the ignition tests in the cold-flow conditions. While using same injector head, combustion instabilities were not encountered during 14 hot-firing tests without pulse-guns but combustion instabilities were triggered by pulse-gun ignition during 2 hot-firing tests. The results showed that the pulse-gun ignition test could be the evaluation method and could reduce the hot-firing test number for the stability rating of a thrust chamber.

Life Firing Test of 1 N-class Monopropellant Thruster Development Model -Part II: Pulse Mode Performance (1 N급 단일추진제 추력기 개발모델의 장기수명 연소시험 -Part II: 펄스모드 성능 특성)

  • Won, Su-Hee;Kim, Su-Kyum;Jun, Hyoung-Yoll;Lee, Jun-Hui;Park, Su-Hyang;Lee, Jae-Won
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.6
    • /
    • pp.68-74
    • /
    • 2014
  • During the life firing test of 1 N-class thruster development model, pulse mode performance and performance changes were examined. The deviation of pulse mode response time according to thruster feed pressure was relatively small and the resultant ignition delay, response time, tail-off time were 32-35 ms, 86-91 ms, 89-98 ms, respectively. For the stabilized pulse region the impulse bit revealed the outstanding reproducibility of 1.41, 1.32, 2.10% at $3{\sigma}$. During the life firing test, the impulse bit was decreased with limited amounts, therefore the pulse mode performance could be considered to be maintained. The thrust centroid was also maintained during the life firing test.

Effect of Electrochemical Redox Reaction on Growth and Metabolism of Saccharomyces cerevisiae as an Environmental Factor

  • Na, Byung-Kwan;Hwang, Tae-Sik;Lee, Sung-Hun;Ahn, Dae-Hee;Park, Doo-Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.445-453
    • /
    • 2007
  • The effect of an electrochemically generated oxidation-reduction potential and electric pulse on ethanol production and growth of Saccharomyces cerevisiae ATCC 26603 was experimented and compared with effects of electron mediators (neutral red, benzyl viologen, and thionine), chemical oxidants (hydrogen peroxide and hypochlorite), chemical reductants (sulfite and nitrite), oxygen, and hydrogen. The oxidation (anodic) and reduction (cathodic) potential and electric pulse activated ethanol production and growth, and changed the total soluble protein pattern of the test strain. Neutral red electrochemically reduced activated ethanol production and growth of the test strain, but benzyl viologen and thionine did not. Nitrite inhibited ethanol production but did not influence growth of the test strain. Hydrogen peroxide, hypochlorite, and sulfite did not influence ethanol production and growth of the test strain. Hydrogen and oxygen also did not influence the growth and ethanol production. It shows that the test strain may perceive electrochemically generated oxidation-reduction potential and electric pulse as an environmental factor.

Study to detect bond degradation in reinforced concrete beams using ultrasonic pulse velocity test method

  • Saleem, Muhammad
    • Structural Engineering and Mechanics
    • /
    • v.64 no.4
    • /
    • pp.427-436
    • /
    • 2017
  • Concrete technologists have used ultrasonic pulse velocity test for decades to evaluate the properties of concrete. However, the presented research work focuses on the use of ultrasonic pulse velocity test to study the degradation in steel-concrete bond subjected to increasing loading. A detailed experimental investigation was conducted by testing five identical beam specimens under increasing loading. The loading was increased from zero till failure in equal increments. From the experimentation, it was found that as the reinforced concrete beams were stressed from control unloaded condition till complete failure, the propagating ultrasonic wave velocity reduced. This reduction in wave velocity is attributed to the initiation, development, and propagation of internal cracking in the concrete surrounding the steel reinforcement. Using both direct and semidirect methods of testing, results of reduction in wave velocity with evidence of internal cracking at steel-concrete interface are presented. From the presented results and discussion, it can be concluded that the UPV test method can be successfully employed to identify zones of poor bonding along the length of reinforced concrete beam. The information gathered by such testing can be used by engineers for localizing repairs thereby leading to saving of time, labor and cost of repairs. Furthermore, the implementation strategy along with real-world challenges associated with the application of the proposed technique and area of future development have also been presented.

A Study on the Pulse Wave Parameter in Post Mastectomy Women (유방암 절제술 여성의 맥파요인 연구)

  • Kim, Gyeong-Cheol;Park, Sang-Wook;Kim, Yi-Soon;Kim, Yun-Hee
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.101-112
    • /
    • 2011
  • Objectives : This study was done to investigate the degree of the pulse wave parameter of post-mastectomy women and to identify the relationships between each of them. Methods : Data were obtained from public health center in Busan Metropolitan city. Participants were 82 post-mastectomy women aged 31-82. the data collection was from Oct, 1, 2010 to Oct, 31, 2010. the data were analyzed with descriptive statistics, one-way ANOVA, Duncan test. A p-value less than .05 was considered significant by 2-tailed test. All statistical analyses were performed with SPSS/Win(ver 12.0). Results : As for the difference in the pulse wave by the general characteristics. The pulse energy was showed highly in the order of Chon, Quan and Chuk of left and right pulse respectively. In the pulse energy of left Quan and right Chon, the case of both mastectomy was showed highly and in the pulse energy of left Chuk, the case of right mastectomy was showed highly. Left and right pulse energy of menopause female were significantly higher than normal range except left Chon and Chuk. In h1, h2, h4, h5, t1, t2, AP and Aw, the pulse energy of left Chon was showed the largest significantly. In As, the pulse energy of right Chon was showed the smallest and in Ad, right Chuk was showed the largest. In RAI, right and left Chuk was showed the highest respectively. Conclusions : From these result, we can see that there are relation between women's age, area of operation breast and menopause after mastectomy in pulse wave. The result of this study will become basic data necessary for the Oriental Medicine treatment to reduce or prevent women's functional difficulties, symptomatology after mastectomy.

Estimation of Compressive Strength of Concrete Using Whinstone Aggregates by Ultrasonic Non-destructive test (초음파법 비파괴 시험에 의한 현무암 골재를 사용한 콘크리트의 강도평가)

  • 김상우;이백수;이승석;류현기;김무한;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.389-392
    • /
    • 2000
  • This paper provide nondestructive test method of concrete by applying ultrasonic pulse test. Whinstone aggregates produced from cheju island are used for coarse aggregate. The purpose of this study is to contribute to the standardization of nondestructive test for estimating compressive strength of concrete manufactured from cheju island. According to experimental results, it is found that compressive strength of Whinstone aggregates concrete shows higher than that of granite stone concrete, whereas ultrasonic pulse of Whinstone aggregates concrete shows lower that of granite concrete Based on the results of this study, estimation formula compressive strength by ultrasonic pulse test are presented in Fig 2.

  • PDF

Estimating Compressive Strength of High Strength Concrerte by Ultrasonic Pulse Velocity Method (초음파속도법에 의한 고강도 콘크리트의 압축강도 추정에 관한 연구)

  • Lim, Seo-Hyung;Kang, Hyun-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.3
    • /
    • pp.123-130
    • /
    • 2001
  • The purpose of this study is to suggest the non-destructive equation for the estimation of concrete strength by ultrasonic pulse velocity at the Age of 28day compressive strength of $600{\sim}1000kg/cm^2$. For this purpose, selected test variables were water-hinder ratio, replacement ratio of silica fume, binder content, maximum size of coarse aggregate and sand-aggregate ratio. From the results, the average increase or decrease of ultrasonic pulse velocity is 61m/sec for each 1% of moisture content. And the correlation equation between the ultrasonic pulse velocity and the compressive strength of concrete is as follows. $F_c=896.3V_p-3514$ ($R^2$ = 0.81) where, $F_c$ : compressive strength($kgf/cm^2$), $V_p$ : ultrasonic velocity(km/sec).

  • PDF

Study of the RF Test signal generation methods for receiver performance verification (신호수신시스템 성능예측을 위한 신호원 모의발생 방안 연구)

  • Kim, Dong-Gyu;Yoon, Won-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.353-356
    • /
    • 2011
  • A Signal Receiving system to collect and analyze RF signals should be verified under simulated RF signal environment prior to verification on operation in fields and tested by using simulated RF signals in order to estimate its electrical performance. Generally, typical Signal Receiving system can measure, analyze frequency, pulse modulation, scan modulation, phase modulation on pulse, frequency modulation on pulse etc on RF signals. These RF signals should be generated from simulated RF sources in laboratory. Also the simultaneous RF signals should be simulated on laboratory. This paper describes the results of studying effective simulated RF signal source generation, the methods of the precise RF test signal generation in consideration of operational scenario.

  • PDF

An Experimental Study of Three Buffer Pulse Tube Refrigerator (Three buffer 맥동관 냉동기에 관한 실험적 연구)

  • 박성제;고득용;김효봉;신완순
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.189-193
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus was constructed. This paper presents operating process of three buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in three pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27W at 120K.

  • PDF

Evaluating the pull-out load capacity of steel bolt using Schmidt hammer and ultrasonic pulse velocity test

  • Saleem, Muhammad
    • Structural Engineering and Mechanics
    • /
    • v.65 no.5
    • /
    • pp.601-609
    • /
    • 2018
  • Steel bolts are used in the construction industry for a large variety of applications that range from fixing permanent installations to temporary fixtures. In the past much research has been focused on developing destructive testing techniques to estimate their pull-out load carrying capacity with very little attention to develop non-destructive techniques. In this regards the presented research work details the combined use of ultrasonic pulse velocity and Schmidt hammer tests to identify anchor bolts with faculty installation and to estimate their pull-out strength by relating it to the Schmidt hammer rebound value. From experimentation, it was observed that the load capacity of bolt depends on its embedment length, diameter, bond quality/concrete strength and alignment. Ultrasonic pulse velocity test is used to judge the quality of bond of embedded anchor bolt by relating the increase in ultrasonic pulse transit time to the presence of internal pours and cracks in the vicinity of steel bolt and the surrounding concrete. This information combined with the Schmidt hammer rebound number, R, can be used to accurately identify defective bolts which resulted in lower pull-out strength. 12 mm diameter bolts with embedment length of 70 mm and 50 mm were investigated using constant strength concrete. Pull-out load capacity versus the Schmidt hammer rebound number for each embedment length is presented.