• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.022 seconds

Development of WMTS Module Based Pulse Rate Period Detection and Human Sensibility Evaluation System (WMTS 무선통신 모듈을 이용한 맥파의 주기검출 및 감성평가 시스템 개발)

  • Lee, Hyun-Min;Kim, Dong-Jun;Jeon, Ki-Man;Son, Jae-Gi
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.811-817
    • /
    • 2013
  • In this study we present a system for pulse-rate period detection and human sensibility evaluation based on the wireless medical telemetry service (WMTS) used for transmission of data from medical telemetry devices to various medical facilities and services. We develop a medical-purpose specific WMTS communication module to transmit biometric signals. From the pulse rate variability(PRV) signal, we attempt to classify positive and negative emotional states based on analysis of the ratio of LF/HF in the frequency domain. We measure the data reception rate according to distance in order to test the performance of the WMTS module and analyze the effects on human sensibility evaluation.

Improvement of Welding Performance of MIG Arc Welding using Superposition Ac Pulse (MIG 아크용접에서의 교류중첩펄스를 이용한 용접성능향상)

  • Kim, Tae-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.141-149
    • /
    • 2008
  • Because aluminum has a lighter weight and higher strength than iron, it is frequently used in the transportation industry for the purpose of reducing the weight of a chassis, and thereby increasing fuel efficiency. However, there are some difficulties with arc welding aluminum due to its lower melting point, high thermal conductivity and oxidation coating on its surface. This study proposed using superposition ac pulse MIG arc welding, which has been improved from the pulse waveform of conventional MIG welding. A MIG arc welding power source was developed to test the effectiveness of this method.

Hybrid Fuzzy PI-Control Scheme for Quasi Multi-Pulse Interline Power Flow Controllers Including the P-Q Decoupling Feature

  • Vural, Ahmet Mete;Bayindir, Kamil Cagatay
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.787-799
    • /
    • 2012
  • Real and reactive power flows on a transmission line interact inherently. This situation degrades power flow controller performance when independent real and reactive power flow regulation is required. In this study, a quasi multi-pulse interline power flow controller (IPFC), consisting of eight six-pulse voltage source converters (VSC) switched at the fundamental frequency is proposed to control real and reactive power flows dynamically on a transmission line in response to a sequence of set-point changes formed by unit-step reference values. It is shown that the proposed hybrid fuzzy-PI commanded IPFC shows better decoupling performance than the parameter optimized PI controllers with analytically calculated feed-forward gains for decoupling. Comparative simulation studies are carried out on a 4-machine 4-bus test power system through a number of case studies. While only the fuzzy inference of the proposed control scheme has been modeled in MATLAB, the power system, converter power circuit, control and calculation blocks have been simulated in PSCAD/EMTDC by interfacing these two packages on-line.

Development of a Reference-Pulse Type 3-Axis Simultaneously Controlled PC-NC Milling System (Reference-Pulse 방식 3축 동시제어 PC-NC 밀링 시스템 개발에 관한 연구)

  • Yang, Min-Yang;Hong, Won-Pyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.11
    • /
    • pp.197-203
    • /
    • 1999
  • Increasing demands on precision machining have necessitated the tool to move not only position error as small as possible, but also with smoothly varying feedrates. Because of the lack of accurate and efficient algorithms for generation of 3-dimensional lines and circles, a full accomlishment for available machine tool resolution is generally unavailable. In this paper, a reference-pulse type 3-axis PC_NC milling system is developed for the precision machining of complex shapes in 3-dimensional space. Three AC servomotors are used as the actuator instead of the hand wheel to operate a 3-axis milling machine under the same mechanical structure. A PC is used to handle the control signal calculation for various types of motion command. To achieve the synchronous 3-axis motion, a real-time reference-pulse 3-dimensional linear and circular interpolator based on the intersection criteria is developed in software. The performance test via computer simulation and actual machining have shown that the PC-NC milling system is useful for the machining of arbitrary lines and circles in 3-dimensional space.

  • PDF

Implementation of Efficient Pile-up Pulse Processing Algorithm Based on Trapezoidal Filter (사다리꼴 필터를 이용한 효율적인 중첩펄스 처리 알고리즘 구현)

  • Piao, Zheyan;Chung, Jin-Gyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.162-167
    • /
    • 2013
  • X-ray or ${\gamma}$-ray spectroscopy systems are widely used for analyzing material characteristics. Pile-up pulses are very often encountered for several reasons in XRF systems. Thus, it is necessary to reject or recover pile-up pulses to accurately analyze the material under test. In this paper, a pile up pulse rejection and recovery method is presented for XRF systems using trapezoidal pulse shaping of the input signals. Since the proposed method is based on the trapezoidal pulse shaping method widely-used in XRF systems, only two counters and a few registers are needed to implement the additional function of pile-up pulse rejection and recovery. Consequently, the proposed system is much simpler than conventional pulse reconstruction systems. It is shown that the proposed method can detect and reject pile-up pulses exactly. It is also shown that the pile-up pulses can be recovered if some conditions are satisfied.

Change in Rouleau Formation of Red Blood Cells by Pulse Magnetic Field Stimulus in the Hand (펄스자기장 자극에 의한 손의 적혈구 형태학적 변화)

  • Hwang, Do Guwn
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.1
    • /
    • pp.28-33
    • /
    • 2014
  • The change of rouleau formation of red blood cells in the hand stimulated by pulse magnetic field having a maximum intensity of 0.27 Tesla and pulse duration of 0.102 msec was investigated. Before pulse magnetic field stimulus, the red blood cells of test subject were adjoined over ten and the flow of cells was slowed. However after the stimulus in the hand during 10 minutes, the red blood cells adjoined over tens was spreaded out each other and its motion was fast. Also the red blood cells of left hand unstimulated by pulse magnetic field were spreaded out each other, even though the right hand was stimulated during 10 minute. It prove that the rouleau formation of red blood cells can be improve in the whole body in spite of stimulus in the hand because the blood is flowing a whole body.

A Case of Moderate Paraquat Intoxication with Pulse Therapy in the Subacute Stage of Pulmonary Fibrosis (파라쿼트로 발생한 폐 섬유화증에서 pulse therapy로 호전된 환자 1례)

  • Hong, Ki-Hun;Jung, Jin-Hee;Eo, Eun-Kyung
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.6 no.2
    • /
    • pp.130-133
    • /
    • 2008
  • In South Korea, attempted suicide by paraquat (PQ) intoxication is fairly common, and is lethal by pulmonary fibrosis and hypoxemia. However, the treatment of PQ poisoning is primarily supportive management. To increase the survival rate associated with PQ intoxication, many treatments have been developed. Here, we treated a case of PQ intoxication with steroid pulse therapy. A 23-year-old man was admitted to the hospital because of PQ intoxication. He drank two mouthfuls of Gramoxon (24% commercial paraquat). His vital signs were stable, but he had a throat infection, and navy blue urine in the sodium dithionite test. Standard treatment, including gastric lavage with activated charcoal was performed, and emergent hemoperfusion with a charcoal filter was initiated 11 h after PQ ingestion. Pharmacotherapy was initiated 18 h after PQ ingestion with the administration of 5 mg dexamethasone. On day 10, chest PA showed pulmonary fibrosis. Therefore, we initiated steroid pulse therapy, with 1g methylprednisolone in 100 mL of D5W administered over 1 h repeated daily for 3 days, and 1 g cyclophosphamide in 100 mL of D5W administered over 1 h daily for 2 days. On day 15, dexamethasone therapy was initiated. On day 30, pulmonary fibrosis was improved. Thus, if pulmonary fibrosis becomes exacerbated after dexamethasone therapy during the subacute stage, pulse therapy with methylprednisolone and cyclophosphamide could be helpful.

  • PDF

A Study on the Analasys of the Eight-Constitution Questionnaire (팔체질 설문문항 분석-I)

  • Kim, Hee-Ju;Shin, Young-Sup;Min, Jae-Young;Kim, Min-Yong;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.22-41
    • /
    • 2008
  • Background: Eight-Constitution Medicine (ECM) devides the human body into eight constitutions. Up until now, checking the pulse types is only way to classify the eight constitution. Recently we try to make a questionnaire that is based on the Eight-Constitution characters and analyze the answer from patients who were classified into one of the eight constitutions according to their pulse types and their responses to constitution-acupuncture therapy Objective: This study intends to analyze each answer of the Eight-Constitution Questionnaire with independent sample t-test. Methods: Participants of this study were outpatients in ECM clinics located in Korea. The resources were collected from 925 patients who were classified into one of the eight constitutions according to their pulse types and their responses to constitution-acupuncture therapy. SPSS 13.0 for Windows was used for independent sample t-test. Results and Conclusions: 1. The proportion of participants' constitutions is in the order of Pancreotonia (28.0%), Colonotonia (17.3%), Pulmotonia (18.1%), Hepatonia (18.1%), Vesicotonia (8.5%), Cholecystotonia (7.0%), Renotonia (2.6%) and Gastrotonia (0.4%). 2. Eight-Constitution Questionnaire consists of 5 parts; Appearance, Character, Body reaction, Physiology & Pathology and Food reaction. 3. 10 items were chosen among 42 question about Appearance. 4. Due to the deficiency of Gastrotonia examples, useful items have to be given up. If we can gather Gastrotonia examples, we can use meaningful items more than 10.

  • PDF

Estimating properties of reactive powder concrete containing hybrid fibers using UPV

  • Nematzadeh, Mahdi;Poorhosein, Reza
    • Computers and Concrete
    • /
    • v.20 no.4
    • /
    • pp.491-502
    • /
    • 2017
  • In this research, the application of ultrasonic pulse velocity (UPV) test as a nondestructive method for estimating some of the mechanical and dynamic properties of reactive powder concrete (RPC) containing steel and polyvinyl alcohol (PVA) fibers, as well as their combination was explored. In doing so, ten different mix designs were prepared in 19 experimental groups of specimens containing three different volume contents of steel fibers (i.e., 1, 2, and 3 %) and PVA fibers (i.e., 0.25, 0.5, and 0.75 %), as well as hybrid fibers (i.e., 0.25-0.75, 0.5-0.5, and 0.75-0.25 %). The specimens in these groups were prepared under the two curing regimes of normal and heat treatment. Moreover, the UPV test results were employed to estimate the compressive strength, dynamic modulus, shear modulus, and Poisson's ratio of the RPC concrete and to investigate the quality level of the used concrete. At the end, the effect of the specimen shape and in fact the measuring distance length on the UPV results was explored. The results of this research suggest that the steel fiber-containing RPC specimens demonstrate the highest level of ultrasonic pulse velocity as well as the highest values of the mechanical and dynamic properties. Moreover, heat treatment has a positive effect on the density, UPV, dynamic modulus, Poisson's ratio, and compressive strength of the RPC specimens, whereas it leads to a negligible increase or decrease in the shear modulus and static modulus of elasticity. Furthermore, the specimen shape affects the UPV of fiber-lacking specimens while negligibly affecting that of fiber-reinforced specimens.

A Study on the Analasys of the Eight-Constitution Questionnaire (8체질 분류 설문지의 문항 분석-II - 성향 및 성격을 중심으로 -)

  • Kim, Hee-Ju;Shin, Young-Sup;Min, Jae-Young;Kim, Min-Yong;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.13 no.1
    • /
    • pp.89-110
    • /
    • 2009
  • Background : Eight-Constitution Medicine (ECM) devides the human body into eight constitutions. Up until now, checking the pulse types is only way to classify the eight constitution. Recently we try to make a questionnaire that is based on the Eight-Constitution characters and analyze the answer from patients who were classified into one of the eight constitutions according to their pulse types and their responses to constitution-acupuncture therapy. Objective : This study intends to analyze each answer of the Eight-Constitution Questionnaire with independent sample t-test. Methods : Participants of this study were outpatients in ECM clinics located in Korea. The resources were collected from 925 patients who were classified into one of the eight constitutions according to their pulse types and their responses to constitution-acupuncture therapy. SPSS 13.0 for Windows was used for independent sample t-test. Results and Conclusions : 1. The proportion of participants' constitutions is in the order of Pancreotonia (28.0%), Colonotonia (17.3%), Pulmotonia (18.1%), Hepatonia (18.1%), Vesicotonia (8.5%), Cholecystotonia (7.0%), Renotonia (2.6%) and Gastrotonia (0.4%). 2. Eight-Constitution Questionnaire consists of 5 parts; Appearance, Character, Body reaction, Physiology & Pathology and Food reaction. 3. 18 items were chosen among 81 question about Character. 4. Due to the deficiency of Gastrotonia examples, useful items have to be given up. If we can gather Gastrotonia examples, we can use meaningful items more than 18.

  • PDF