Non-destructive Testing Methods to Evaluate the Effectiveness of Crack Repair Using Expoxy and Microcement (균열 주입부의 비파괴 검사에 의한 주입효과 판정에 관한 연구)

  • 최홍식;이시우;이호범;송영철;방기성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.841-846
    • /
    • 2002
  • Development on non-destructive testing methods were performed to evaluate the effectiveness of crack repair for test beams induced a crack. Cracked beams are repaired with expoxy and microcement, and then they are tested by two methods, the ultrasonic pulse velocity method and the transfer function method. It is proved that the ultrasonic pulse velocity method is very valid for the evaluation of the effectiveness on expoxy repair, and the transfer function method is very applicable to evaluate the effectiveness on microcement repair.

  • PDF

Analysis of Insulation Characteristics of Low-Voltage Induction Motors Fed by Pulse-Controlled Inverters (인버터 구동형 저압 유동전동기의 절연특성 분석)

  • 박도영
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.195-198
    • /
    • 2000
  • In this paper the insulation characteristics test results of 25 low-voltage induction motors($3\phi$, 5HP, 380V) are presented. Five different types of insulation techniques are applied to 25 motors. The maximum partial discharge (PD) magnitude ($\textrm{Q}_{m}$) discharge inception voltage (DIV) dissipation factor tip-up ($\Delta$tan$\delta$) and rate of change in AC current($\Delta$I) are measured by PD and AC current tests. Also the insulation breakdown tests by high voltage pulse are performed and the corresponding breakdown voltage are obtained.

  • PDF

The Effects of Essential Oils from Softwood on Pain and Cardiovascular System (침엽수종 유래 정유가 진통 및 순환기계에 미치는 영향)

  • 나기정;정의배
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.253-256
    • /
    • 1999
  • The influence of essential oils from aboriginal softwoods as Pinus densiflora, Pinus koraiensis, Chamaecyparis obtusa and Chamaecyparis pisifera on the motor coordination, pulse, mean blood artery pressure and pain reducing test was investigated in mice and rats. The motor coordination of mouse was not induced by the inhalation of each oil. Furthermore, these oils did not alter the changes of the mean blood pressure and pulse rate. Chamaecyparis pisifera trand to reduce the mean blood pressure. The abdominal pain induced by acetic acid was reduced only by an essential oil from Pinus koraiensis in mouse.

  • PDF

Pulse-Grouping Control Method for High power Density DC/DC Converters

  • Kang, Shin-Ho;Jang, Jun-Ho;Lee, Jun-Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.2 s.19
    • /
    • pp.45-48
    • /
    • 2007
  • The proposed method offers an improved DC/DC converter scheme to increase power density. It is based on half-bridge topology with newly introduced pulse-grouping control method, which helps to reduce the transformer size and the volume of semiconductor devices maintaining high efficiency. Test results with 85W(18.5V/4.6A) design shows that the measured efficiency is 93.5% with power density of $36W/in^3$.

  • PDF

Characteristics of Lightweight Concrete and Their Application in Structures

  • ;R.N. Swamy
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.34 no.E
    • /
    • pp.60-69
    • /
    • 1992
  • The research significance of the paper is to identify the major properties of synthetic lightweight concrete that are affected by ASR expansion and to determine the extent and magnitude of the loss in these properties. Emphasis is also given to the use of non-destructive testing techniques ; Such as dynamic modulus of elasticity and ultrasonic pulse velocity, to examine whether these methods could be used to identify the initiation of expansion and the internal structural damage caused by ASR.

  • PDF

Development of Airborne High Density High Voltage Power Supply for Traveling Wave Tubes

  • Park Young-Ju
    • Journal of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.257-263
    • /
    • 2005
  • This paper describes the development and testing results of a high density High Voltage Power Supply (HVPS) that drives microwave Traveling Wave Tubes (TWTs) of phased array transmitters for airborne EW systems. The HVPS is designed to consist of a number of modules connected in series. Among them, especially, the high-density pulse transformer module including the resonant circuit is newly designed to make the HVPS much more reliable. In addition, this paper describes the development of high voltage solid-state modulation using fast switching devices (FETs) and also represents the test results of a modulator module.

Pressure Drop Predictions Using Multiple Regression Model in Pulse Jet Type Bag Filter Without Venturi (다중회귀모형을 이용한 벤츄리가 없는 충격기류식 여과집진장치 압력손실 예측)

  • Suh, Jeong-Min;Park, Jeong-Ho;Cho, Jae-Hwan;Jin, Kyung-Ho;Jung, Moon-Sub;Yi, Pyong-In;Hong, Sung-Chul;Sivakumar, S.;Choi, Kum-Chan
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.2045-2056
    • /
    • 2014
  • In this study, pressure drop was measured in the pulse jet bag filter without venturi on which 16 numbers of filter bags (Ø$140{\times}850{\ell}$) are installed according to operation condition(filtration velocity, inlet dust concentration, pulse pressure, and pulse interval) using coke dust from steel mill. The obtained 180 pressure drop test data were used to predict pressure drop with multiple regression model so that pressure drop data can be used for effective operation condition and as basic data for economical design. The prediction results showed that when filtration velocity was increased by 1%, pressure drop was increased by 2.2% which indicated that filtration velocity among operation condition was attributed on the pressure drop the most. Pressure was dropped by 1.53% when pulse pressure was increased by 1% which also confirmed that pulse pressure was the major factor affecting on the pressure drop next to filtration velocity. Meanwhile, pressure drops were found increased by 0.3% and 0.37%, respectively when inlet dust concentration and pulse interval were increased by 1% implying that the effects of inlet dust concentration and pulse interval were less as compared with those changes of filtration velocity and pulse pressure. Therefore, the larger effect on the pressure drop the pulse jet bag filter was found in the order of filtration velocity($V_f$), pulse pressure($P_p$), inlet dust concentration($C_i$), pulse interval($P_i$). Also, the prediction result of filtration velocity, inlet dust concentration, pulse pressure, and pulse interval which showed the largest effect on the pressure drop indicated that stable operation can be executed with filtration velocity less than 1.5 m/min and inlet dust concentration less than $4g/m^3$. However, it was regarded that pulse pressure and pulse interval need to be adjusted when inlet dust concentration is higher than $4g/m^3$. When filtration velocity and pulse pressure were examined, operation was possible regardless of changes in pulse pressure if filtration velocity was at 1.5 m/min. If filtration velocity was increased to 2 m/min. operation would be possible only when pulse pressure was set at higher than $5.8kgf/cm^2$. Also, the prediction result of pressure drop with filtration velocity and pulse interval showed that operation with pulse interval less than 50 sec. should be carried out under filtration velocity at 1.5 m/min. While, pulse interval should be set at lower than 11 sec. if filtration velocity was set at 2 m/min. Under the conditions of filtration velocity lower than 1 m/min and high pulse pressure higher than $7kgf/cm^2$, though pressure drop would be less, in this case, economic feasibility would be low due to increased in installation and operation cost since scale of dust collection equipment becomes larger and life of filtration bag becomes shortened due to high pulse pressure.

Test & Evaluation for the Configuration Optimization of Thrust Chamber in 70 N-class N2H4 Thruster (Part II: Pulse-mode Performance According to the Chamber Length Variation) (70 N급 하이드라진 추력기의 추력실 최적설계와 시험평가 (Part II: 추력실 길이변화에 따른 펄스모드 성능특성))

  • Jung, Hun;Kim, Jong Hyun;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.1
    • /
    • pp.50-57
    • /
    • 2014
  • A ground hot-firing test (HFT) was conducted to take out the optimal design configurations for the thrust chamber of 70 N-class liquid rocket engine under development. Monopropellant grade (purity: ${\geq}98.5%$) hydrazine was adopted as a propellant for the HFT, and three kinds of thrust chambers having characteristic lengths ($L^*$) of 2.79, 2.95, and 3.13 m were selected for their performance evaluation. It is revealed through the test and evaluation that the increase of the $L^*$ leads to a performance degradation in the test condition specified, and pulse response performance of the development model shows superior characteristics to commercialized hydrazine thrusters.

Development and Testing of a Prototype Long Pulse Ion Source for the KSTAR Neutral Beam System

  • Chang Doo-Hee;Oh Byung-Hoon;Seo Chang-Seog
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.357-363
    • /
    • 2004
  • A prototype long pulse ion source was developed, and the beam extraction experiments of the ion source were carried out at the Neutral Beam Test Stand (NBTS) of the Korea Superconducting Tokamak Advanced Research (KSTAR). The ion source consists of a magnetic bucket plasma generator, with multi-pole cusp fields, and a set of tetrode accelerators with circular apertures. Design requirements for the ion source were a 120kV/65A deuterium beam and a 300 s pulse length. Arc discharges of the plasma generator were controlled by using the emission-limited mode, in turn controlled by the applied heating voltage of the cathode filaments. Stable and efficient arc plasmas with a maximum arc power of 100 kW were produced using the constant power mode operation of an arc power supply. A maximum ion density of $8.3{\times}10^{11}\;cm^{-3}$ was obtained by using electrostatic probes, and an optimum arc efficiency of 0.46 A/kW was estimated. The accelerating and decelerating voltages were applied repeatedly, using the re-triggering mode operation of the high voltage switches during a beam pulse, when beam disruptions occurred. The decelerating voltage was always applied prior to the accelerating voltage, to suppress effectively the back-streaming electrons produced at the time of an initial beam formation, by the pre-programmed fast-switch control system. A maximum beam power of 0.9 MW (i.e. $70\;kV{\times}12.5\;A$) with hydrogen was measured for a pulse duration of 0.8 s. Optimum beam perveance, deduced from the ratio of the gradient grid current to the total beam current, was $0.7\;{\mu}perv$. Stable beams for a long pulse duration of $5{\sim}10\;s$ were tested at low accelerating voltages.

Classification method of chronic gastritis by modeling of pulse signal (맥파 모델링을 통한 만성위염 분류 기법)

  • Choi, Sang-Ho;Shin, Ki-Young;Shin, Jitae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.3
    • /
    • pp.144-151
    • /
    • 2012
  • Chronic gastritis is the disease that is occuring in one in every 10 persons in Korea. In western medicine, endoscopy is needed to diagnose chronic gastritis, but it causes patients a pain and budget of expense. According to the TEM (Traditional Eastern Medicine), on the other hand, the 'Guan' position of the right wrist is related to a stomach. Thus we can diagnosis chronic gastritis by analyzing of pulse signal. However, pulse signal diagnosis is depended on oriental doctor's knowledge and experience. In this study, a systematic approach is proposed to analyze the computerized pulse signal. The pulse signals are firstly pre-processed, Gaussian model is adopted to fit the pulse signal, and then some related parameters are extracted from the model. Consequently, disease-sensitive parameters are selected by T-test and statistical difference. Finally, the selected parameters are entered into a Fuzzy C-Means (FCM) algorithm for classification. Classification results show that healthy persons and chronic gastritis patients are 95% and 87%, respectively.