• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.027 seconds

Analysis of Comparison Test and Measurement Error Factor for I - V Performance of Photovoltaic Module (PV모듈 발전성능 비교시험과 계측편차 요인 분석)

  • Kang, Gi-Hwan;Kim, Kyung-Soo;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.70-75
    • /
    • 2009
  • In this experiment, we did sampling 6 kinds of photovoltaic modules and analyzed the discrepancy of measurement results between l laboratory and 4 PV makers to have performance repeatability at Standard Test Condition(STC) condition. From the KIER's results, Korea's standard test laboratory, other laboratory showed -10% measurement variation. The causes came from correction of reference cell, test condition and the state of skill. Form the comparison test, we analyzed the problems. But three PV maker reduced measurement variation, other one PV maker and one test laboratory didn't improve the problems of correction of reference cell, test condition and the state of skill. Also, High Efficiency Module had a big discrepancy of -10.0$\sim$-6.2% among 3 laboratories which have a less than 10msec light pulse duration time. This made low spectrum response speed so the Fill Factor decreased maximum output power under 10msec light pulse duration time

Clinical Test on Application of ShiHo-GuizhiTang (시호계지탕(柴胡桂枝湯)의 임상치험(臨床治驗)에 관(關)한 소고(小考))

  • Lee, Min-seop;Kim, Dong-hee;Shin, Soon-shik
    • Journal of Haehwa Medicine
    • /
    • v.9 no.1
    • /
    • pp.201-214
    • /
    • 2000
  • Precise and detailed clinical research and evaluation based on objective standards are imperative factors in securing reliability of a clinical test. Built on this principle, this clinical test has been conducted during the period between March 1999 and March 2000 dealing with 31 outpatients treated with ShiHo-GuizhiTang or ShiHo-GuizhiTang modify and ShiHo-GuizhiTang mixed prescriptions at the Sung-bo ORIENTAL MEDICAL CLINIC. A variety of information relating to those patients has been collected and analyzed under such criteria as precise diagnoses and their clinical effectiveness. The analysis was duly based on "The theory of cold syndrome". Then, the 31 patients' individual clinical information was compared one another by breaking down the results into sub-categories including gender, age, disease, main symptom, blood pressure, pulse beats, syndrome of abdomen, treatment period, modify and mixed prescription, and evaluation. The result of this clinical test can be summarized as follows: First, ShiHo-GuizhiTang appears to be more frequently prescribed in the case of female patients than in the case of male patients despite the fact that it does not necessarily need to be applied only to female. In addition, the numbers of prescriptions of ShiHo-GuizhiTang in the two age groups consisting of elementary school children and economically active adults respectively were the highest among other age groups. Second, ShiHo-GuizhiTang proved to be most effective in treatment for respiratory ailments and arthritis. Third, ShiHo-GuizhiTang brought down blood pressure of hypertension patients and at the same time benefited patients with normal or lower-than-normal blood pressure who were vulnerable to diseases due to low disease-resistance. Fourth, ShiHo-GuizhiTang was effective in the case of frequent pulse(rapid pulse) and thereby indicating the fact it carries Taiyang superficies syndrome. 지맥 arises from suppressed immune responses owing to adrenocortical hormones. ShiHo-GuizhiTang controls and revitalizes those suppressed immune systems which stem from slow pulse and, as a consequence of that process, helps them return to normal condition of pulse. Fifth, from the standpoint of syndrome of abdomen, feeling of obstruction in the epigastrium serves as an important standard in the process of diagnosing diseases and evaluating effectiveness of treatments. Sixth, according to the results of the clinical test with the 31 patients, a total of 81 percent of test subjects benefited from the treatment. The figure is the sum of 52 percent of I-class (both main symptom and accompanying symptoms had been eliminated) and 29 percent of II-class (part of main symptom and accompanying symptoms had been eliminated) respectively. All told it is safe to say that ShiHo-GuizhiTang can elect to be a viable clinical treatment. In conclusion, it is estimated that this clinical study has drawn up guidelines for objective diagnostic standards and evaluation on specific treatments' effectiveness. This will lead to more general application of ShiHo-GuizhiTang. On top of that, this study could also provide an opportunity to stress the significance of ShiHo-GuizhiTang and ShiHo-GuizhiTang modify and ShiHo-GuizhiTang mixed prescriptions as an alternative treatment for collagen disease which comes from environmental degradation and pollution.

  • PDF

Development and High Power RF Test of the Vacuum Feedthrough for KSTAR ICRF Antenna

  • Bae, Young-Dug;Hwang, Churl-Kew;Kwak, Jong-Gu
    • Nuclear Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.211-217
    • /
    • 2002
  • A 1-MW vacuum feedthrough for the KSTAR ICRF antenna is fabricated and high power RF test is performed. It is designed to have two alumina $(Al_2O_3)$ ceramic cylinders and O-ring seal instead of a brazed seal for good mechanical and thermal strength, which is important in long pulse or steady state operation. For cooling of the ceramics, dry air is circulated in a space between the two cylinders and the outer conductor. Independent cooling water channels are installed to cool the inner conductor of the feedthrough. RF high voltage test is performed using two kinds of ceramics with the purities of 99.7% and 97%. Stable operation is possible with the RF voltage of 30 kVp at long pulse of 300 sec without any severe damage.

High Power Microwave Resonant Ring (고출력 마이크로파 Resonant Ring)

  • Park, S.S.;Park, S.W.;Kim, S.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1275-1277
    • /
    • 1995
  • We designed and constructed an extremly high power s-band traveling wave resonator for the test of high power microwave components using 80MW pulsed klystron with $4{\mu}s$ pulse width. The 10dB directional coupler for the input power coupling was used, and the ring consists of phase shifter, tuner, H-band, and other microwave components. The designed total electrical length of the system is 10 times of the waveguide wavelength, ${\lambda}_g$=15.3cm, and the measured total insertion loss is 0.15dB. The low power test measurment showed the power multiplication of 14.69. The design goal is to achieve the peak power of 300MW, pulse width $4{\mu}s$ with 30 pulse repetition rate. In this article we discuss the treveling wave resonant ring constructed at the PAL laboratory together with the test results.

  • PDF

Test & Evaluation for the Configuration Optimization of Thrust Chamber in 70 N-class N2H4 Thruster (Part I: Pulse-mode Performance According to the Chamber Diameter Variation) (70 N급 하이드라진 추력기의 추력실 최적설계와 시험평가 (Part I: 추력실 직경변화에 따른 펄스모드 성능특성))

  • Kim, Jong Hyun;Jung, Hun;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.1
    • /
    • pp.42-49
    • /
    • 2014
  • Performance evaluation was carried out for the 70 N-class hydrazine thruster whose design performance had been already verified. The pulse-mode firing test was conducted for the development model thrusters with various thrust chamber diameters. Evaluation was made by the performance parameters such as specific impulse, impulse bit, and characteristic velocity, etc: specific impulse and characteristic velocity were deteriorated as the thrust chamber diameter deviates from a standard model. Consequently, it is revealed that the performance characteristics of standard model is most superior among the test models.

Development of a Finite Element Model for Frontal Crash Analysis of a Mid-Size Truck (중형 트럭의 정면 충돌 특성해석을 위한 유한요소 모델의 개발)

  • 홍창섭;오재윤;이대창
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.4
    • /
    • pp.226-232
    • /
    • 2000
  • This paper develops a finite element model for studying the crashworthiness analysis of a mid-size truck. A simulation for a truck frontal crash to a rigid barrier using the model is performed with PAM-CRASH installed in super computer SP2. Full vehicle model is composed of 86467 shell elements, 165 beam elements and 98 bar elements, and 86769 nodes. The model uses four material model such as elastic, elastic-plastic(steel), rigid and elastic-plastic(rubber) material model which are in PAM-CRASH. Frame and suspension system are modeled with 28774 shell elements and 31412 nodes. Cab is modeled with 34680 shell elements and 57 beam elements, and 36254 nodes. Bumper is modeled with 2262 shell elements, and 2508 nodes. Axle, steering shaft, etc are modeled using beam or bar elements. Mounting parts are modeled using rigid bodies. Bodies are interconnected using nodal constrains or joint options. To verify the developed model, frontal crash test with 30mph velocity to a rigid barrier is carried out. In the crash test, vehicle pulse at lower part of b-pillar is measured, and deformed shapes of frame and driver seat area are photographed. Those measured vehicle pulse and photographed pictures are compared those from the simulation to verify the developed finite element model.

  • PDF

Performance Estimation and Test of Protype Pulse Tube Cryopump (맥동관형 크라이오펌프 시제품 성능예측과 평가)

  • In, Sang Ryul;Kang, Sang Paek
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.2
    • /
    • pp.45-54
    • /
    • 2013
  • The cryopump of the pulse tube type has been developed successfully, and manufacturing of a prototype pump is finished under leading of Woosung Vacuum. The target pumping speed of the prototype pump is above 3,600 L/s for nitrogen with the intake port of 14 inches I.D (16 inches O.D). For designing optimally the pump structure including the charcoal array, thermal shield, and baffle, the pumping speed was simulated for various configurations through Monte Carlo method. Pumping performances of the protype cryopump manufactured on the basis of optimal design were conformed experimentally with a standard test system and procedures. The measured $N_2$ pumping speed of the prototype cryopump was 4,600 L/s which agreed well with simulated one and exceeded the target value.

Effect of Hematocrit Level on the Radial Pulse Wave (적혈구 용적이 요골 동맥의 맥파에 미치는 영향)

  • Ryu, Hyun-Hee;Jeon, Young-Ju;Kim, Jae-Uk;Lee, Hae-Jung;Woo, Young-Jae;Lee, Yu-Jung;Kim, Jong-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.1035-1040
    • /
    • 2009
  • In this work, we investigate the effect of blood hematocrit level on the radial pulse wave to study the clinical application of the pulse analyzer. For this purpose, we measured the radial pulse wave at the left Gwan for 15 males with abnormal high hematocrit level and 47 males with normal hematocrit level at the age of thirties and forties. Various variables of the radial pulse wave between two groups were analyzed by Student's T test. We found significant differences in several characteristic variables in the amplitude, time-span and the integrated area of the amplitude and time of the pulse wave. The systolic peak in the amplitude of the radial pulse wave was higher in abnormal high hematocrit group. In contrast, the third peak from the second incisure was higher and longer in normal hematocrit group. Our study suggests that the radial pulse wave can be useful in distinguishing the patient group with high hematocrit level and thus with high blood viscosity. Our finding may motivate research activities towards diverse clinical applications of the pulse wave.

Performance improvement of 2 stage GM-type pulse tube Cryocooler for cryopump

  • Park, Seong-Je;Koh, Deuk-Yong;Suh, Jeong-Kyoon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.4
    • /
    • pp.30-35
    • /
    • 2011
  • This paper describes experimental study and performance improvement of 2 stage Gifford-McMahon (G-M) type pulse tube cryocooler for cryopump. The objective of this study is to improve the efficiency of 2 stage pulse tube cryocooler for substituting 2 stage G-M cryocooler used in cryopump. The target cooling capacities are 5 W at 20 K and 35 W at 80 K for the $1^{st}$ and the $2^{nd}$ stage, respectively. These values are good cooling capacities for vacuum level in medium size ICP 200 cryopump. Design of the 2 stage pulse tube cryocooler is conducted by FZKPTR(Forschungs Zentrum Karlsruhe Pulse Tube Refrigerator) program. In order to improve the performance of 2 stage pulse tube cryocooler, U-type pulse tube cryocooler is fabricated and connecting tubes are minimized for reducing dead volumes and pressure losses. Also, to get larger capacities, orifice valves and double inlet valves are optimized and the compressor of 6 kW is used. On the latest unit, the lowest temperatures of 2 stage pulse tube cryocooler are 42 K ($1^{st}$ stage) and 8.3 K ($2^{nd}$ stage) and the cooling capacities are 40 W at 82.9 K ($1^{st}$ stage) and 10 W at 20.5 K ($2^{nd}$ stage) with 6.0 kW of compressor input power. This pulse tube cryocooler is suited for commercial medium size cryopump. In performance test of cryopump with 2 stage pulse tube cryocooler, pumping speed for gaseous nitrogen is 4,300 L/s and the ultimate vacuum pressure is $7.5{\times}10^{-10}$ mbar.

The Femto Second Laser Induced Ablation on the Titanium Alloy for Various Beam Overlap Ratio (빔 중첩율에 따른 티타늄 합금의 펨토초 레이저 어블레이션)

  • Chung, Il-Young;Kang, Kyung-Ho;Kim, Jae-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.17-23
    • /
    • 2010
  • Titanium alloy is one of the hard processing materials made by the traditional manufacturing method because of the excellent mechanical strength. Ablation of titanium alloy is investigated by using a femtosecond laser which is a regenerative amplified Ti:sapphire laser with 1kHz repetition rate, 184fs pulse duration time and 785nm wavelength. Experiments are carried out under various ablation conditions with different pulse overlap ratios for the rectangular shape and micro hole. Test results show that the ablation characteristic according to pulse overlap ratio of titanium alloy seems to be as non-linear type at the different zone of energy fluence. The optimal condition of rectangular shape processing is obtained at the laser peak power 1.3mW, pulse overlap ratio of 90%, beam gap of $1\;{\mu}m$. The micro hole has a good quality from the pulse overlap ratio of 99% at the same laser peak power. With the optimal processing condition, the fine rectangular shape and micro hole without burr and thermal damage are achieved.