• Title/Summary/Keyword: Pulse sequence

Search Result 308, Processing Time 0.025 seconds

Characteristics of Image Sticking Observed During Background Display in AC-PDP (AC PDP의 배경광 잔상특성)

  • 류재화;임성현;김동현;김중균;이호준;박정후
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.2
    • /
    • pp.91-96
    • /
    • 2004
  • In darkroom condition, it was observed that a white picture pattern lasted several minutes leaves a recognizable trace in subsequent black background picture. Although this is not a serious problem for the most current public display or home TV applications, the image sticking should be minimized for future high quality multimedia display applications. In order to characterize this picture memory effect having relatively long time scale, spatially resolved luminance measurement and light waveform measurement have been performed. Pixels located at the outer boundary of white pattern previously displayed shows highest luminance. These cells also shows fastest ignition at the ramp up reset sequence. The luminance and ignition voltage differences between boundary cells and the other cells are increased with display duration and number of sustain-pulse. It is speculated that image sticking observed at the boundary cell is originated from the transport of charged particles and re-deposition of reactive species such as Mg, O provided from strong sustain discharge region.

Carrier Based Common Mode Voltage Reduction Techniques in Neutral Point Clamped Inverter Based AC-DC-AC Drive System

  • Ojha, Amit;Chaturvedi, Pradyumn;Mittal, Arvind;Jain, Shailendra
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.142-152
    • /
    • 2016
  • Common mode voltage (CMV) generation is a major problem in switching power converter fed induction motor drive systems. CMV is the zero sequence voltage generated due to the switching action of power converters. Even a small magnitude of CMV with a high rate of change may circulate large bearing currents which may damage a machine's bearings and shorten its life. There are several methods of controlling CMV. This paper presents 3-level sinusoidal pulse width modulation based techniques to control the magnitude and rate of change of CMV in multilevel AC-DC-AC drive systems. Simulation and experimental investigations have been presented to validate the performance of proposed technique to control CMV in 3-level neutral point clamped inverter based AC-DC-AC system.

Sensorless Starting Method and Fuel Pressure Control of BLDC Motor for Fuel Pump of Vehicle (자동차 연료 펌프용 BLDC 모터의 센서리스 기동 및 연료 압력 제어)

  • Chang, Jin-Wook;Yoon, Duck-Yong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.2
    • /
    • pp.114-121
    • /
    • 2013
  • High efficiency operation is required for motors of vehicle to increase fuel efficiency due to the regulation of exhaust gas. This paper presents a control method of fuel pressure to increase fuel efficiency and a sensorless control method of BLDC motor to get higher efficiency than conventional brushed DC motor. Initial rotor position of BLDC motor is detected from current value that is occurred by test voltage pulse and rotor is accelerated by defined sequence to enter sensorless operation mode. The algorithm to control flow rate of fuel pump uses PI controller that is control motor speed to maintain the target fuel pressure commanded by ECU.

A Study on the Biotelemetry using Infra-red Light (적외선을 이용한 생체신호의 원격측정에 관한 연구)

  • Huh, Soo-Jin
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.169-175
    • /
    • 1993
  • Recently, interest in infra-red(IR) telemetry has increased because of the entirely different propagation and reflection properties of IR light as compared to radiowaves. IR hardly penetrates most materials and is reflected from obstacles. An biotelemetry system using these characteristics of indirect transmitted IR lights was developed, in which 3 ECG's are multiplexed and modulated in PDM/PIM pulse sequence. This proto-type system enables us to realize the non-restraint measurement of biological signals. Compared with conventional radio telemetry, this technique has some merits such as no electromagnetic interference, no frequency allocation problem, no government control over transmission power.

  • PDF

Multi-Parametric Quantitative MRI for Measuring Myelin Loss in Hyperglycemia-Induced Hemichorea

  • Youn, Sung Won;Kwon, Oh Dae;Hwang, Moon Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.148-156
    • /
    • 2019
  • Hyperglycemia-induced hemichorea (HGHC) is a rare but characteristic hyperkinetic movement disorder involving limbs on one side of the body. In a 75-year-old woman with a left-sided HGHC, conventional brain MR imaging showed very subtle T1-hyperintensity and unique gadolinium enhancement in the basal ganglia contralateral to movements. Multi-parametric MRI was acquired using pulse sequence with quantification of relaxation times and proton density by multi-echo acquisition. Myelin map was reconstructed based on new tissue classification modeling. In this case report of multi-parametric MRI, quantitative measurement of myelin change related to HGHC in brain structures and its possible explanations are presented. This is the first study to demonstrate myelin loss related to hyperglycemic insult in multi-parametric quantitative MR imaging.

Advanced Methods in Dynamic Contrast Enhanced Arterial Phase Imaging of the Liver

  • Kim, Yoon-Chul
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.1
    • /
    • pp.1-16
    • /
    • 2019
  • Dynamic contrast enhanced (DCE) magnetic resonance (MR) imaging plays an important role in non-invasive detection and characterization of primary and metastatic lesions in the liver. Recently, efforts have been made to improve spatial and temporal resolution of DCE liver MRI for arterial phase imaging. Review of recent publications related to arterial phase imaging of the liver indicates that there exist primarily two approaches: breath-hold and free-breathing. For breath-hold imaging, acquiring multiple arterial phase images in a breath-hold is the preferred approach over conventional single-phase imaging. For free-breathing imaging, a combination of three-dimensional (3D) stack-of-stars golden-angle sampling and compressed sensing parallel imaging reconstruction is one of emerging techniques. Self-gating can be used to decrease respiratory motion artifact. This article introduces recent MRI technologies relevant to hepatic arterial phase imaging, including differential subsampling with Cartesian ordering (DISCO), golden-angle radial sparse parallel (GRASP), and X-D GRASP. This article also describes techniques related to dynamic 3D image reconstruction of the liver from golden-angle stack-of-stars data.

Principles of Magnetic Resonance Angiography Techniques

  • Shin, Taehoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.209-217
    • /
    • 2021
  • Magnetic resonance angiography (MRA) plays an important role in accurate diagnosis and appropriate treatment planning for patients with arterial disease. Contrast-enhanced (CE) MRA is fast and robust, offering hemodynamic information of arterial flow, but involves the risk of a side effect called nephrogenic systemic fibrosis. Various non-contrast-enhanced (NCE) MRA techniques have been developed by utilizing the fact that arterial blood is moving fast compared to background tissues. NCE MRA is completely free of any safety issues, but has different drawbacks for various approaches. This review article describes basic principles of CE and NCE MRA techniques with a focus on how to generate angiographic image contrast from a pulse sequence perspective. Advantages, pitfalls, and key applications are also discussed for each MRA method.

Optical Signal Sampling Based on Compressive Sensing with Adjustable Compression Ratio

  • Zhou, Hongbo;Li, Runcheng;Chi, Hao
    • Current Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.288-296
    • /
    • 2022
  • We propose and experimentally demonstrate a novel photonic compressive sensing (CS) scheme for acquiring sparse radio frequency signals with adjustable compression ratio in this paper. The sparse signal to be measured and a pseudo-random binary sequence are modulated on consecutively connected chirped pulses. The modulated pulses are compressed into short pulses after propagating through a dispersive element. A programmable optical filter based on spatial light modulator is used to realize spectral segmentation and demultiplexing. After spectral segmentation, the compressed pulses are transformed into several sub-pulses and each of them corresponds to a measurement in CS. The major advantage of the proposed scheme lies in its adjustable compression ratio, which enables the system adaptive to the sparse signals with variable sparsity levels and bandwidths. Experimental demonstration and further simulation results are presented to verify the feasibility and potential of the approach.

Evaluation of Image Quality using SE-EPI and SSH-TSE Techniques in MRDWI (자기공명확산강조영상에서 SE-EPI 와 SSH-TSE 기법을 이용한 영상의 질 평가)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.991-998
    • /
    • 2021
  • The purpose of this study is to investigate the image quality of the SE-EPI and SSH-TSE technique for MR DWI. Datum were analyzed for 35 PACS transmission datum(Normal part: 12 males, 13 females, Cerebral Infarction: 10(5males and 5females), and average age 68±7.32), randomly selected patients who underwent MRDWI tests. The equipment used was Ingenia CX 3.0T, SSH_TSE and SE-EPI pulse sequence and 32 Ch. head coil were used for data acquisition. Image evaluation was performed on the paired t-test and Wilcoxon tests, and was considered significant when the p value was 0.05 or less. As a result of quantitative analysis of SNR for DWI images, the mean and standard deviation values of 4 parts (WM, GM, BG, Cerebellum) in ADC (s/mm2), Diffusion b=0, 1000 images were higher in SE-EPI techniques(ADC: 120.50 ± 40, b=0: 54.50 ± 35.91, b=1000: 91.61 ± 36.63) than in SSH-TSE techniques(ADC: 99.69 ± 31.10, b=0: 43.52 ± 25.00 , b=1000: 60.74 ± 24.85)(p<0.05). The CNR values for GM-WM, BG-WM sites were also higher in SE-EPI technique (ADC: 116.08 ± 43.30, b=0:27.23 ± 09.10, b=1000: 78.50 ± 16.56) than in SSH-TSE(ADC: 101.08 ± 36.81, b=0: 23.96 ± 07.79 , b=1000: 74.30 ± 14.22). As a visual evaluation of observers, ghost artifact, magnetic susceptibility artifacts and overall image quality for SE-TSE and SSH-TSE all yielded high results from SSH-TSE techniques(ADC:3.6 ± 0.1, 2.8 ± 0.2, b=0: 4.3 ± 0.3, 3.4 ± 0.1 b=1000: 4.3 ± 0.2, 3.5 ± 0.2, p=0.000). In conclusion, the SE-EPI technique obtained an superiority in SNR and CNR measurements using SSH-TSE, SE-EPI. In the qualitative analysis, the SSH-TSE pulse sequence was obtained a high result according to the pulse sequence characteristics.

MR Imaging Measurement of the Femoral Anteversional Angle as a PACS Image Viewer (MR 영상에서의 PACS Image Viewer를 이용한 대퇴골 전염각 측정)

  • Kweon, Dae-Cheol;Yang, Sung-Hwan;Park, Peom
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.83-89
    • /
    • 2003
  • The accurate measurement of the femoral anteversion is very important to the practice of orthopedic and osteotomy. It is measured by means of the axis of head and neck of the femur and the knee axis. At the present time, widely used computed tomography method of measuring anteversion on femoral necks of patients. Measurement by the manual method and image viewer of computed tomography to determine the anteversion of femoral head were carried out on both femurs. In September and October 2002, 5 patients 28 to 36 years of age were randomly selected from Seoul National University Hospital. The purpose of this paper was to introduce a new method to measure femoral anteversion angle utilizing PACS image viewer program in the MR imaging. Significant difference was observed between the right and left side the image viewer measurement of femoral anteversion. In conclusion, MR imaging very usefulness in the measured the angle of the femoral anteversion.

  • PDF