• Title/Summary/Keyword: Pulse sequence

Search Result 308, Processing Time 0.026 seconds

Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review (간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

Performance of PN Code Based Time Hopping Sequences in M-ary Ultra Wide Band Multiple Access Systems Using Equicorrelated Signal Sets (동일 상관 신호군을 이용하는 M-ary UWB 다원 접속 시스템에서 PN 부호 기반 시간 도약 시퀀스의 성능)

  • 양석철;신요안
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.10A
    • /
    • pp.816-829
    • /
    • 2003
  • In this paper, we evaluate the performance of PN (Pseudo Noise) code based time hopping sequences for M-ary UWB (Ultra Wide Band) multiple access systems using the equicorrelated signal sets. In particular, we consider two different types of M-ary UWB systems in UWB indoor wireless multipath channels: The first type of the systems (System #1) has identical symbol transmission rate regardless of the number of symbols M since the length of signal pulse train is fixed while M increases, and the second type of the systems (System #2) has the same bit transmission rate regardless of M since the length of signal pulse train is extended according to the increase of M. We compare the proposed systems with those using the ideal random time hopping sequence in terms of the symbol error rate performance. Simulation results show that the PN code based time hopping sequence achieves quite good performance which is favorably comparable to that of the ideal random sequence. Moreover, as M increases, we observe that System #2 shows better robustness against multiple access interference than System # 1.

MR Angiography with Simultaneous Data Acquisition of Arteries and Veins(SAAV) Method and Artery-Vein Color Mapping in 0.3T MRI System (0.3T MRI 시스템에서의 동.정맥 동시 획득을 위한 자기공명 혈류 영상 기법(SAAV)과 동.정맥 color mapping)

  • 조종운;조지연;서성만;은충기;문치웅
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.275-280
    • /
    • 2003
  • The method of simultaneous data acquisition of arteries and veins(SAAV) was suggested to obtain MR angiography of arteries and veins at 0.3T low filed MRI system (Magfinder, AlLab. Korea). Two separated artery- and vein-images were put together using AVCM(Artery-Vein Color Mapping) algorithm and presented in the same image. In this study, artery- and vein-separated angiograms of volunteer's neck were obtained. Two dimensioal blood-enhanced images wre sequentially obtained using SAAV pulse sequence based on time-of-flight(TOF) method with flow compensation. Imaging parameters were TR/TE=70/12msec. FOV=230mm, slice thickness = 3mm, flip angle=90$^{\circ}$, matrix size=256${\times}$256${\times}$64mm. TSat TH/SPA=15/20mm, Ts_v=10msec and Ts_a=40ms. 3D MRA images were reconstructed using the maximum intensity projection(MIP) and the artery-vein color mapping(AVCM) algorithm. This study showed good possibility of clinical applications of MRA in 0.3T which provides valuable diagnostic information of clinical vascular diseases.

Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model

  • Dae Joong Kim;Kun Hwang;Hun Kim;Jang Gyu Cha;Hyungseok Jang;Ju-Yong Park;Yeo Ju Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.782-791
    • /
    • 2021
  • Objective: To evaluate the signal intensity of the periosteum using ultrashort echo time pulse sequence with three-dimensional cone trajectory (3D UTE) with or without fat suppression (FS) to distinguish from artifacts in porcine tibias. Materials and Methods: The periosteum and overlying soft tissue of three porcine lower legs were partially peeled away from the tibial cortex. Another porcine tibia was prepared as three segments: with an intact periosteum outer and inner layer, with an intact periosteum inner layer, and without periosteum. Axial T1 weighted sequence (T1 WI) and 3D UTE (FS) were performed. Another porcine tibia without periosteum was prepared and subjected to 3D UTE (FS) and T1 WI twice, with positional changes. Two radiologists analyzed images to reach a consensus. Results: The three periosteal tissues that were partially peeled away from the cortex showed a high signal in 3D UTE (FS) and low signal on T1 WI. 3D UTE (FS) showed a high signal around the cortical surface with an intact outer and inner periosteum, and subtle high signals, mainly around the upper cortical surfaces with the inner layer of the periosteum and without periosteum. T1 WI showed no signal around the cortical surfaces, regardless of the periosteum state. The porcine tibia without periosteum showed changes in the high signal area around the cortical surface as the position changed in 3D UTE (FS). No signal was detected around the cortical surface in T1 WI, regardless of the position change. Conclusion: The periosteum showed a high signal in 3D UTE and 3D UTE FS that overlapped with artifacts around the cortical bone.

Design of ECG/PPG Gating System in MRI Environment (MRI용 심전도/혈류 게이팅 시스템 설계)

  • Jang, Bong-Ryeol;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.132-138
    • /
    • 2007
  • MR(magnetic resonance) image of moving organ such as heart shows serious distortion of MR image due to motion itself. To eliminate motion artifacts, MRI(magnetic resonance imaging) scan sequences requires a trigger pulse like ECG(electro-cardiography) R-wave. ECG-gating using cardiac cycle synchronizes the MRI sequence acquisition to the R-wave in order to eliminate image motion artifacts. In this paper, we designed ECG/PPG(photo-plethysmography) gating system which is for eliminating motion artifacts due to moving organ. This system uses nonmagnetic carbon electrodes, lead wire and shield case for minimizing RF(radio-frequency) pulse and gradient effect. Also, we developed a ECG circuit for preventing saturation by magnetic field and a finger plethysmography sensor using optic fiber. And then, gating pulse is generated by adaptive filtering based on NLMS(normalized least mean square) algorithm. To evaluate the developed system, we measured and compared MR imaging of heart and neck with and without ECG/PPG gating system. As a result, we could get a clean image to be used in clinically. In conclusion, the designed ECG/PPG gating system could be useful method when we get MR imaging of moving organ like a heart.

Performance of Multi-rate Optical Wireless PPM-CDMA System over an Indoor Non-directed Diffuse Channel (실내 비방향성 분산채널에서 다중전송률 광무선 PPM-CDMA 시스템의 성능 분석)

  • 황성수;이재홍
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.7A
    • /
    • pp.943-950
    • /
    • 2000
  • In this paper, an asynchronous multi-rate optical wireless pulse position modulation-code division multiple access (PPM-CDMA) is proposed for an indoor non-directed diffuse channel. As a signature sequence for CDMA, an optical orthogonal code (OOC) is used and an interference cancellation scheme is applied to improve the bit error rate. It is known that the optical PPM-CDMA has advantages due to its power efficiency. Moreover, it provides multi-rate services by varying the modulation level with fixed pulse duration. In the proposed multi-rate PPM-CDMA system with fixed pulse duration, chip rate and sampling time do not change for each transmission rate and this simplifies overall system structure.

  • PDF

Damped dynamic responses of a layered functionally graded thick beam under a pulse load

  • Asiri, Saeed A.;Akbas, Seref D.;Eltaher, Mohamed A.
    • Structural Engineering and Mechanics
    • /
    • v.75 no.6
    • /
    • pp.713-722
    • /
    • 2020
  • This article aims to illustrate the damped dynamic responses of layered functionally graded (FG) thick 2D beam under dynamic pulse sinusoidal load by using finite element method, for the first time. To investigate the response of thick beam accurately, two-dimensional plane stress problem is assumed to describe the constitutive behavior of thick beam structure. The material is distributed gradually through the thickness of each layer by generalized power law function. The Kelvin-Voigt viscoelastic constitutive model is exploited to include the material internal damping effect. The governing equations are obtained by using Lagrange's equations and solved by using finite element method with twelve -node 2D plane element. The dynamic equation of motion is solved numerically by Newmark implicit time integration procedure. Numerical studies are presented to illustrate stacking sequence and material gradation index on the displacement-time response of cantilever beam structure. It is found that, the number of waves increases by increasing the graduation distribution parameter. The presented mathematical model is useful in analysis and design of nuclear, marine, vehicle and aerospace structures those manufactured from functionally graded materials (FGM).

Signal Processing and Implementation of Transmitter for Cochlear Implant (인공 와우를 위한 신호 처리 및 전달부의 구현)

  • Chae, D.;Choi, D.;Byun, J.;Baeck, S.;Kong, H.;Park, S.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.284-286
    • /
    • 1993
  • Software and hardware for cochlear implant system have been developed to create a speech signal processing system which, in real-time, extracts model parameter including formants, pitch, amplitude information. The system is based on the Texas Instruments TMS320 family. In hardware, computer interface has been desisted and implemented that allows presentation of biphasic pulse stimuli to patients with the hearing handicapped. The host computer sends a stream of bytes to the parallel port. Upon receipt of the data the interface generates the appropriate burst sequence that is delivered to the patient's external transmitter coil. The coded information is interpreted by the Nucleus-22 internal receiver that delivers the pulse to the specified electrodes at the specified amplitude and pulse width.

  • PDF

Elucidation of Central Line Refocusing in Quadrupolar Echo Formation

  • Han, Duk-Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.3 no.1
    • /
    • pp.27-35
    • /
    • 1999
  • Quadrupolar interaction is a strong line broadening agent for nuclei of half-integer spin except the central line. The two-pulse quadrupolar echo technique is widely used, which refocuses the quadrupolar broadening. Echo formation is due to the cancellation of quadrupolar broadening effect by the applied two pulses. Since the central line is not quadrupolar broadened, it should not be involved in the echo formation. However, the central line peak always appears in experiments. This is explained qualitatively here by close examination on the time development of individual coherence. This explanation is used to predict the number of echoes that will be formed with 2 pulse sequence for nuclei of I=3/2, 5/2, 7/2, 9/2 with ease.

  • PDF

A Study on Performance Analysis of IEEE 802.15.4b Noncoherent Receivers at 915MHz under Pulse Jamming (Pulse Jamming 환경 하에서 IEEE 802.15.4b 915MHz 비동기식 수신기 성능 분석에 대한 연구)

  • Lee, Sung-Yong;Cheong, Cha-Keon
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.296-298
    • /
    • 2009
  • In this paper, we are performance analysis of IEEE 802.15.4b LR-WAPN(Low-Rate Wireless Personal Area Network; Zigbee) system noncoherent receivers at 915MHz under Jamming. IEEE 802.15.4b concerns itself with devices at 915MHz, which employ a higher data rate of up to 250 kbps, and which use O-QPSK(Offset Quradrature Phase Shift Keying modulation with DSSS(Direct Sequence Spread Spectrum). Communication between devices can still be hampered by the presence of interferers outside the network, whether the interference be intentional or not. Hence the receivers can not have stable receiving condition due to worse BER. To solve this problem, we present a mere stabilized receiver system of using noncoherent detection. In this paper, we look instead at the effect of jamming, i.e. intentional interference, on the BER performance of IEEE 802.15.4 devices.

  • PDF