• Title/Summary/Keyword: Pulse rates

Search Result 245, Processing Time 0.024 seconds

Protective Effects and Anti-oxidative Effects of Sipjeon-Daebo-Tang and Gami-Sipjeon-Daebo-Tang in C6 Glioma Cell (십전대보탕(十全大補湯) 및 가미십전대보탕(加味十全大補湯)의 항산화 효과 및 신경교세포주 보호 효과)

  • Lee, Sang-Yeong;Kim, Hyung-Woo;Kim, Gye-Yep;Choi, Chan-Hun;Yun, Yeo-Chung;Jeong, Hyun-Woo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.6
    • /
    • pp.1292-1298
    • /
    • 2009
  • Sipjeon-Daebo-Tang (SDT) is indicated for deficiency syndrome of both gi and blood, marked by pale or sallow complexion, dizziness, lassitude, shortness of breath, dislike for talking, poor appetite, pale tongue with thin whitish fur, thready and weak pulse. Gami-Sipjeon-Daebo-Tang(GSDT) is composed of 10 herbs within SDT and Cervi Pantotrichum Cornu (CPC). CPC can noursh kidney-yang, promote the production of the essence and blood, strengthen tendons and bones. Recently SDT is known as anti-cancer drug. Especially CPC is reported to have anti-oxidative action. For these reasons, we investigated the protective effects on cell death induced by chemicals such as paraquat, hydrogen peroxide and anti-oxidative effects in C6 glioma cells. In our results, GSDT accelerated proliferation rates of C6 cells in vitro. In addition, protective effects on cell death induced by hydrogen peroxide and rotenone. In addition, SOD activities were increased by treatment with both SDT and GSDT. In conclusion, these results suggest the possibility of GSDT to protect brain cell or neuronal cell from damage induced by oxidative stress. And also suggest that related mechanisms are involved in SOD activities.

Partial Discharge Phenomena with $SF_{6}$ Gas Pressures in Insulation Consisted of Insulation Paper and $SF_{6}$ Gas(II) ($SF_{6}$가스와 절연지의 절연계에서 가스압력에 따른 부분방전 현상(II))

  • Seon, Jong-Ho;Kim, Gwang-Hwa;Park, Jeong-Hu;Jo, Jeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.9
    • /
    • pp.430-435
    • /
    • 2002
  • The $SF_{6}$ gas insulated power equipments have the insulation systems which are composed of $SF_{6}$ gas and insulation paper. It is repored that their insulation abilities are influenced by the $SF_{6}$ gas gaps in those insulation systems and gas pressures. This paper describes partial discharge phenomena with $SF_{6}$ gas pressures in insulation system of $SF_{6}$ gas-insulation paper Specimens of $SF_{6}$ gas-insulation paper were prepared and aramid paper was used as insulation paper. Partial discharge inception voltages(PDIV) and breakdown voltages for the existence of $SF_{6}$ gas gaps were measured by short term tests with gas pressures. Also, average PD quantities and pulse counts, life times of each specimens were calculated from the results of long term aging tests with gas pressures. It was found that the $SF_{6}$ gas gaps decrease increasing rates of PDIV and brealdown voltages according to gas pressure increase and the insulation breakdown caused by the smaller PD quantities than 1[pC] at the high gas pressure of 300kPa is due to the increase of energy density with increase of gas pressure.

An Ultrasonic Measurement Model to Predict a Reflected Signal from Non-Linear Burning Surface of Solid Propellants

  • Song, Sung-Jin;Kim, Hak-Joon;Oh, Hyun-Taek;Lee, Sang-Won;Song, Seung-Hyun;Kim, In-Chul;Yoo, Ji-Chang;Jung, Jung-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.6
    • /
    • pp.531-540
    • /
    • 2007
  • While determination of the solid propellant burning rates by ultrasound, it has been reported that the frequent data scatters were caused by two major factors; 1) variation in the acoustical properties, and 2) non-linear burning of a solid propellant sample under investigation. This work is carried out for the purpose of investigating the effect of non-linear burning of solid propellant samples. Specifically, we propose an ultrasonic measurement model that can predict the reflections from solid propellant surfaces with non-linear burning by the combination of two ingredients; 1) a pulse-echo ultrasonic measurement model for a planar, circular reflector imbedded in the second medium in an immersion set-up, and 2) an efficient model of non-linear burning surfaces with a number of small, planar circles. Then, we demonstrate the capability of the proposed measurement model by simulation of the surface echo signals from four different burning surfaces that have been generated by the combination of two factors; the base shape (flat or paraboloidal) and the surface roughness (perfectly smooth or randomly rough). From the simulation presented here, we can confirm the fact that the non-linear burning of the propellant can cause the waveform change of the burning surface echo and the corresponding spectrum variation.

Effect of Spiral Turbulent Ring on Detonation Performances of Acetylene-Oxygen Mixture (나선형 난류고리가 아세틸렌-산소 혼합기의 데토네이션파 성능에 미치는 영향)

  • Son, Min;Seo, Chanwoo;Lee, Keon Woong;Koo, Jaye;Smirnov, N.N.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.2
    • /
    • pp.9-15
    • /
    • 2013
  • An effect of a spiral turbulent ring, so-called Shchelkin spiral, on a detonation performance was studied experimentally for acetylene and oxygen mixture. A couple of dynamic pressure transducers were used to calculate a detonation wave velocity by a time difference between two pressure peaks. In addition, impulse was measured by a load cell and the impulse was used to analyze the spiral effect on the detonation performance. A CFD analysis was adopted to calculate mass flow rates of the propellants and the minimum filling time. The maximum velocity and pressure were measured at the equivalence ratio of 2.4, and the measured values showed similar trend to C-J conditions calculated from CEA. For the shorter chamber with the short spiral, the maximum detonation velocity was appeared. In contrast, the longer chamber without the spiral showed the maximum thrust performance.

Central Venous Catheterization before Versus after Computed Tomography in Hemodynamically Unstable Patients with Major Blunt Trauma: Clinical Characteristics and Factors for Decision Making

  • Kim, Ji Hun;Ha, Sang Ook;Park, Young Sun;Yi, Jeong Hyeon;Hur, Sun Beom;Lee, Ki Ho
    • Journal of Trauma and Injury
    • /
    • v.31 no.3
    • /
    • pp.135-142
    • /
    • 2018
  • Purpose: When hemodynamically unstable patients with blunt major trauma arrive at the emergency department (ED), the safety of performing early whole-body computed tomography (WBCT) is concerning. Some clinicians perform central venous catheterization (CVC) before WBCT (pre-computed tomography [CT] group) for hemodynamic stabilization. However, as no study has reported the factors affecting this decision, we compared clinical characteristics and outcomes of the pre- and post-CT groups and determined factors affecting this decision. Methods: This retrospective study included 70 hemodynamically unstable patients with chest or/and abdominal blunt injury who underwent WBCT and CVC between March 2013 and November 2017. Results: Univariate analysis revealed that the injury severity score, intubation, pulse pressure, focused assessment with sonography in trauma positivity score, and pH were different between the pre-CT (34 patients, 48.6%) and post-CT (all, p<0.05) groups. Multivariate analysis revealed that injury severity score (ISS) and intubation were factors affecting the decision to perform CVC before CT (p=0.003 and p=0.043). Regarding clinical outcomes, the interval from ED arrival to CT (p=0.011) and definite bleeding control (p=0.038), and hospital and intensive care unit lengths of stay (p=0.018 and p=0.053) were longer in the pre-CT group than in the post-CT group. Although not significant, the pre-CT group had lower survival rates at 24 hours and 28 days than the post-CT group (p=0.168 and p=0.226). Conclusions: Clinicians have a tendency to perform CVC before CT in patients with blunt major trauma and high ISS and intubation.

Performance of hybrid modulation for digital IoT doorlock system with color grid (컬러그리드기반 디지털 IoT 도어락 시스템을 위한 혼합변조의 성능)

  • Lee, Sun-Yui;Sun, Young-Ghyu;Sim, Issac;Hwang, Yu-Min;Yoon, Sung-Hoon;Cha, Jae-Sang;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.91-97
    • /
    • 2018
  • This paper presents implementation possibilities of digital IoT doorlock systems via VLC(Visible Light Communication)'s color grid. The color grid-based VLC modulation scheme which are discussed in this paper utilize the straightness of light and abundant frequency resources which are the properties of the light. Performance results in this paper are compared to that of conventional modulations with Bit Error Rate (BER) and Signal to Noise Ratio (SNR) simulations. With respect to a channel model, the proposed modulation schemes select the nearest Line Of Sight (LOS) except Non Line Of Sight (NLOS). Experiments in this paper show error rates of received symbols by changing power dB at a distance of 3m between Tx and Rx in an indoor environment. Through performance results and experiments, this paper demonstrates superiority of the proposed color grid-based modulation schemes.

Feasibility study of CdZnTe and CdZnTeSe based high energy X-ray detector using linear accelerator

  • Beomjun Park;Juyoung Ko;Jangwon Byun;Byungdo Park ;Man-Jong Lee ;Jeongho Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2797-2801
    • /
    • 2023
  • CdZnTeSe (CZTS) has attracted attention for applications in X- and gamma-ray detectors owing to its improved properties compared to those of CdZnTe (CZT). In this study, we grew and processed single crystals of CZT and CZTS using the Bridgeman method to confirm the feasibility of using a dosimeter for high-energy X-rays in radiotherapy. We evaluated their linearity and precision using the coefficient of determination (R2) and relative standard deviation (RSD). CZTS showed sufficient RSD values lower than 1.5% of the standard for X-ray dosimetry, whereas CZT's RSD values increased dramatically under some conditions. CZTS exhibited an R2 value of 0.9968 at 500 V/cm, whereas CZT has an R2 value of 0.9373 under the same conditions. The X-ray response of CZTS maintains its pulse shape at various dose rates, and its properties are improved by adding selenium to the CdTe matrix to lower the defect density and sub-grain boundaries. Thus, we validated that CZTS shows a better response than CZT to high-energy X-rays used for radiotherapy. Further, the applicability of an onboard imager, a high-energy X-ray (>6 MV) image, is presented. The proposed methodology and results can guide future advances in X-ray dose detection.

In Vitro Development of Bovine Nuclear Transfer Embryos Reconstructed with Fetal Fibroblasts (태아 섬유아세포로 재구성된 핵치환 소 수정란의 체외발달)

  • Koo, D.B.;Choi, Y.H.;Park, J.S.;Kim, H.N.;Kang, Y.K.;Lee, C.S.;Han, Y.M.;Park, H.D.;Lee, K.K.
    • Korean Journal of Animal Reproduction
    • /
    • v.24 no.4
    • /
    • pp.407-417
    • /
    • 2000
  • The present study was to examine effects of various electrical stimulus treatments used for electro-fusion on the preimplantation development of bovine nuclear transfer (NT) embryos with fetal fibroblast cells. Fetal fibroblast cells were isolated from one fetus at day 45 of gestation in Holstein cow, and passaged 3 to 4 times before being transferred into enucleated oocytes. Single fibroblast cells were individually placed into the perivitelline space of enucleated oocytes by using a micromanipulator. At first, the fusion and developmental rates of reconstructed oocytes were compared between different electric stimulation conditions. When fusion of the reconstructed oocyte was induced by different electric pulse periods (15, 30 and 45 $\mu$sec) at a DC pulse of 1.8 kV/cm, 15 (45.5%, 120/264) or 30 $\mu$ sec group (43.9%, 106/241) showed a higher fusion rate than 45 $\mu$sec group (23.2%, 58/250, P<0.05). However, no difference was detected in the development rate of the fused oocytes to blastocysts between groups. Next experiment was to examine the effects of different electrical field strengths (1.5, 1.8 and 2.1 kV/cm) for 15 $\mu$sec at electrofusion on in vitro development of the NT embryos. As results, there was no difference in the fusion and developmental rates of the NT embryos between electrical strength (P>0.05). Finally, developmental competence of bovine NT embryos with somatic cells was compared with IVF-derived embryos. Of enucleated oocytes fused with fibroblast cells, 27.4% (75/274) developed to the blastocyst stage, which is similar to that (24.5%, 58/237) of IVF-derived embryos. However, mean nuclei number of NT blastocysts was smaller than that of IVF-derived blastocysts. Thus, we have established an optimal condition (1.8 kV/cm, 15 $\mu$sec) for electric fusion of bovine NT oocytes with somatic cells. The present study indicates that bovine reconstructed embryos with somatic cells normally develop to blastocyst stage in vitro, although having smaller nuclei numbers of blastocysts as compared to IVF-derived embryos.

  • PDF

$^{17}O$ NMR Study On Water Excharge Rate of Paramagnetic Contrast Agents ($^{17}O$ NMR 기법을 이용한 상자성 자기공명조영제의 물분자 교환에 관한 연구)

  • Yongmin Chang;Sung Wook Hong;Moon Jung Hwang;Il Soo Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.33-37
    • /
    • 2001
  • Purpose : The water exchange rate between bulk water and bound water is an important parameter in deciding the efficiency of paramagnetic contrast agents. In this study, we evaluated the water exchange rates of various Gd-chelates using oxygen-17 NMR technique. Material and Methods : The samples (Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA, Gd-EOB-DTPA) were prepared by mixing 5% $^{17}O-enriched$ water (Isotech, USA). The pH of the samples was adjusted to physiological value [pH=7.0] by buffer solution. The variable temperature $^{17}O-NMR$ measurements were performed using Bruker-600 (14.1 T, 81.3 MHz) spectrometer. Bruker VT-1000 temperature control units were used to stabilize the temperature. The $^{17}O$ spin-spin relaxation times (T2) were measured using Carr-Purcell-Meiboom-Gill (CPMG)I pulse sequence with 24 echo trains. The variable temperature T2 relaxation data were then fitted into Solomon-Bloembergen equations using least square fit algorithm to estimate the water exchange times. Results : From the measured $^{17}O-NMR$ relaxation rates, the determined water exchange rates at 300K are $0.42{\;}{\mu}s$ for Gd-DTPA, $1.99{\;}{\mu}s$ for Gd-DTPA-BMA, $0.27{\;}{\mu}s$ for Gd-DOTA, and $0.11{\;}{\mu}s$ for Gd-EOB-DTPA. The Gd-DTPA-BMA showed slowest exchange whereas Gd-EOB-DTPA had fastest water exchange rate. In addition, it was found that the water exchange rates (${\tau}_m$) of all samples had exponential temperature dependence with different decay constant. Conclusion : $^{17}O-NMR$ relaxation rate measurements, when combined with variable temperature technique, provide a solid tool for studying water exchange rate, which is very important in investigating the detailed mechanism of relaxation enhancement effect of the paramagnetic contrast agents.

  • PDF

Effects of Electric Stimulation and Activation Conditions on the Fusion and Development of Porcine Somatic Cell Nuclear Transfer Embryos (전기적 융합과 활성화 방법이 돼지 체세포 복제수정란의 체외발달에 미치는 영향)

  • 정기화
    • Journal of Embryo Transfer
    • /
    • v.19 no.1
    • /
    • pp.43-51
    • /
    • 2004
  • The present study was conducted to investigate the effects of fusion and/or activation protocol on in vitro development of porcine somatic cell nuclear transfer (SCNT) embryos. Porcine fetal fibroblast cells were transferred into the perivitelline space of enucleated in vitro matured oocytes. Cell fusion and activation were induced simultaneous fusion/activation (SA) or delayed activation (DA) with or without cytochalasin B (CB) treatment with electic pulses in 0.28 M mannitol-based medium. The SCNT embryos were cultured in vitro for 7 days and stained with Hoechst 33342 to determine the number of nuclei. After 7 days culture, cleavage and blastocyst formation rates were 72.4% and 7.6% in SCNT and 76.3% and 20.4% in parthenotes. To examine the effect of electric field strengths on development of SCNT embryos, oocytes were fused two pulses of 110 V/mm, 130 V/mm or 150 V/mm for 30 sec post-injection. The fusion and cleavage rates in 130 V/mm group (70.2% and 72.6%) and 150 V/mm group (72.6% and 70.5%) were higher (P<0.05) than 110 V/mm group (47.1% and 48.6%), respectively. However, the rate of embryos developing to the blastocyst stage (8.1%, 9.7% and 10.7%) were not different among three groups. The cleavage rates and the blastcyst formation rates were not different among three treatment groups (SA group, 71.4% and 9.7%; SA+CB treatment group, 74.7% and 8.0%; DA+CB treatment group, 70.8% and 11.2%, respectively). And, no different in the number of cells in blastocysts was observed among the three groups (22.5$\pm$12.8, 23.3$\pm$11.2 and 21.6$\pm$10.4, respectively). These result suggest that two pulses of 130 V/mm or 150 V/mm for 30 sec with SA treatment or DA treatment are enough for fusion/activation of porcine somatic cell nuclear transfer (SCNT) embryos to develop to the blastocyst stage.