• Title/Summary/Keyword: Pulse rate

Search Result 1,679, Processing Time 0.035 seconds

Speed Control of DC Motor for Roller Type Seeder (롤러형 파종기 구동용 직류모터의 회전속도 제어)

  • 이중용;김유용;박상래
    • Journal of Biosystems Engineering
    • /
    • v.25 no.5
    • /
    • pp.351-358
    • /
    • 2000
  • This study was conducted to develop a speed control system of a DC motor which drove a barley seeder mounted on a combine harvester. Barley seeder mounted on a combine has been known to reduce labor and cost of barley cultivation. However, development of the seeder has been unsuccessful because the combine, a dedicated rice and barley harvester has not enough space and proper power take-off for barley seeder. To develop a barley seeder, small powered motor speed controller was required. A proximity sensor for detecting working speed of the combine and a programmable one board microprocessor was used to develope a control system. Motor parameters and motor constant, relationship between seeding rate, motor speed, groove volumes of a tested roller, torque were measured. The proximity sensor sent a frequency signal to the microprocessor. In laboratory experiments, the excitation voltage of the motor was shown not to be proportional to the size of pulse width (duty ratio). A table transforming frequency signal, that represented for working speed to proper pulse width was developed from seeding rate experiments. However, seeding rate at low frequency signal was not proportional to the working speed. Seeding rate control proportional to the frequency signal was achieved by shifting of the frequency signal.

  • PDF

An ACLMS-MPC Coding Method Integrated with ACFBD-MPC and LMS-MPC at 8kbps bit rate. (8kbps 비트율을 갖는 ACFBD-MPC와 LMS-MPC를 통합한 ACLMS-MPC 부호화 방식)

  • Lee, See-woo
    • Journal of Internet Computing and Services
    • /
    • v.19 no.6
    • /
    • pp.1-7
    • /
    • 2018
  • This paper present an 8kbps ACLMS-MPC(Amplitude Compensation and Least Mean Square - Multi Pulse Coding) coding method integrated with ACFBD-MPC(Amplitude Compensation Frequency Band Division - Multi Pulse Coding) and LMS-MPC(Least Mean Square - Multi Pulse Coding) used V/UV/S(Voiced / Unvoiced / Silence) switching, compensation in a multi-pulses each pitch interval and Unvoiced approximate-synthesis by using specific frequency in order to reduce distortion of synthesis waveform. In integrating several methods, it is important to adjust the bit rate of voiced and unvoiced sound source to 8kbps while reducing the distortion of the speech waveform. In adjusting the bit rate of voiced and unvoiced sound source to 8 kbps, the speech waveform can be synthesized efficiently by restoring the individual pitch intervals using multi pulse in the representative interval. I was implemented that the ACLMS-MPC method and evaluate the SNR of APC-LMS in coding condition in 8kbps. As a result, SNR of ACLMS-MPC was 15.0dB for female voice and 14.3dB for male voice respectively. Therefore, I found that ACLMS-MPC was improved by 0.3dB~1.8dB for male voice and 0.3dB~1.6dB for female voice compared to existing MPC, ACFBD-MPC and LMS-MPC. These methods are expected to be applied to a method of speech coding using sound source in a low bit rate such as a cellular phone or internet phone. In the future, I will study the evaluation of the sound quality of 6.9kbps speech coding method that simultaneously compensation the amplitude and position of multi-pulse source.

High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved Ion-Recombination Corrections

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Jang, Kyoung Won
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.145-152
    • /
    • 2020
  • Purpose: In ionization-chamber dosimetry for high-dose-rate electron beams-above 20 mGy/pulse-the ion-recombination correction methods recommended by the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) are not appropriate, because they overestimate the correction factor. In this study, we suggest a practical ion-recombination correction method, based on Boag's improved model, and apply it to reference dosimetry for electron beams of about 100 mGy/pulse generated from an electron linear accelerator (LINAC). Methods: This study employed a theoretical model of the ion-collection efficiency developed by Boag and physical parameters used by Laitano et al. We recalculated the ion-recombination correction factors using two-voltage analysis and obtained an empirical fitting formula to represent the results. Next, we compared the calculated correction factors with published results for the same calculation conditions. Additionally, we performed dosimetry for electron beams from a 6 MeV electron LINAC using an Advanced Markus® ionization chamber to determine the reference dose in water at the source-to-surface distance (SSD)=100 cm, using the correction factors obtained in this study. Results: The values of the correction factors obtained in this work are in good agreement with the published data. The measured dose-per-pulse for electron beams at the depth of maximum dose for SSD=100 cm was 115 mGy/pulse, with a standard uncertainty of 2.4%. In contrast, the ks values determined using the IAEA and AAPM methods are, respectively, 8.9% and 8.2% higher than our results. Conclusions: The new method based on Boag's improved model provides a practical method of determining the ion-recombination correction factors for high dose-per-pulse radiation beams up to about 120 mGy/pulse. This method can be applied to electron beams with even higher dose-per-pulse, subject to independent verification.

A Study on the Microhole Machining Characteristics of the ${Al_2}{0_3}$ Ceramics using Excimer Laser (Excimer laser를 이용한 알루미나(${Al_2}{0_3}$) 세라믹의 미세구멍 가공 특성에 대한 연구)

  • 김병용;이건상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.1072-1075
    • /
    • 2001
  • $Al_2O_3$ ceramics are generally used as components in processing equipment, devices or machinery because it can perform some functions better than competing metals or polymers. Many of these applications rely on $Al_2O_3$ ceramics special electromagnetic properties, its relative chemical inertness, hardness, strength and its temperature capabilities. But $Al_2O_3$ ceramics are brittle materials, a fact that may cause problems and at the same time be helpful while machining with laser. This study described a basic study of the input parameters effect on the dimension of the microhole at the $Al_2O_3$ ceramics using Excimer laser. In the laser microhole machining of $Al_2O_3$ ceramics, major input parameters are pulse energy, pulse power, pulse frequency and pulse numbers. In conclusion, we can get a smaller microhole and diameter rate by an appropriate pulse energy, pulse frequency and pulse number.

  • PDF

Lab-Scale Biosparging Study to Remediate Diesel-Contaminated Soil and Groundwater : the effect of air injection rate and pattern

  • 조수형;이시진;권순열;장순웅
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.462-466
    • /
    • 2003
  • This study was conducted to examine the potential of biosparging process in removing diesel contaminated soil and groundwater. The experiment was carried out lab-scale biosparging reactor and the biodegradation rate of diesel was evaluated as function of air injection rate and pattern. When renter was operated as air injection rate of 1000$m\ell$/min and pulsed air injection(15min pulse, 15min downtime), DO concentration in the renter was higher than another operating condition. The evidence for biodegradation of diesel was the $O_2$ utilization and $CO_2$ product following the cessation of sparging. Especially, air injection rate of 2000$m\ell$/min and pulsed air injection(15min pulse, 15min downtime) enhanced the diesel biodegradation during the operating. After 120day, the biodegradation rate of diesel was decreased as the lack of carbon source.

  • PDF

Effects of Information Provision on Anxiety, Blood Pressure & and Pulse in Cerebral Angiography Clients (정보제공이 뇌혈관조영술 대상자의 불안, 혈압, 맥박에 미치는 영향)

  • Lee, Sun Yeon;Lee, Kyung-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.18 no.4
    • /
    • pp.280-287
    • /
    • 2016
  • Purpose: This study was to evaluate the effects of information on anxiety, blood pressure and pulse in cerebral angiography clients. Methods: The data were collected from June to November 2014. The participants were 42 (21 each for experimental and control group) patients who to received cerebral angiography. The information developed from researchers' materials for cerebral angiography was provided only to experimental group. Measured variables were anxiety, systolic and diastolic blood pressure, and pulse rate. Research tools for anxiety were Spielberger's state anxiety inventory, and 10 point visual analogue scale (VAS). Results: The difference in mean systolic blood pressure after intervention between the experimental group ($129{\pm}15.34$) and the control group ($141{\pm}17.70$) was statistically significant (t=-2.28, p=.028). The differences between the two groups in state anxiety, VAS anxiety, diastolic blood pressure, and pulse rate after intervention were not statistically significant (p>.05). Conclusion: The information using educational material was effective in to decreasing systolic blood pressure in patients who received cerebral angiography. Therefore this study material could be used as a nursing intervention for patients in cerebral angiography.

Effects of Moxibustion on Physiological Indices and Autonomic Nervous Symptoms in Adults with Prehypertension (뜸요법이 전고혈압 성인의 생리적 지수와 자율신경계 증상에 미치는 효과)

  • Cho, Soon-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.5
    • /
    • pp.686-694
    • /
    • 2010
  • Purpose: This study was done to examine the effects of moxibustion on physiological indices, such as 24-hr blood pressure, pulse pressure, and pulse rate, and autonomic nervous symptoms among adults with prehypertension. Methods: Participants were adults whose systolic and diastolic blood pressures were in the prehypertension stage and were not under treatment for the condition. Both experimental and control group consisted of 13 participants who were taking classes on acupuncture and moxibustion at a private institute. The experimental group received moxibustion once a day for 15 min, at least 5 days a week for 8 weeks. The results were analyzed using $x^2$-test, t-test, Fisher's exact test, Wilcoxon rank sum test and repeated measures ANOVA with the SAS program. Bonferroni correction method was adopted for multiple comparisons. Results: No significant change was observed in the 24-hr systolic and diastolic blood pressure between the two groups. Differences in the 24-hr pulse pressure and pulse rate were also not significant. However, significant decreases in headache, symptoms of flushing and fatigue were observed in the experimental group. Conclusion: The results suggest that moxibustion contributes to alleviating symptoms such as headache, flushing and fatigue associated with the autonomic nervous system among adults with prehypertension.

Expansion Ratio of Pulse Power Underreamed Anchor (펄스방전 그라운드 앵커의 확공 특성에 관한 연구)

  • Kim, Nak-Kyung;Ju, Yonh-Sun;Kim, Sung-Kyu;Seo, Hyo-Kyun;Kim, Sun-Ju
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1107-1112
    • /
    • 2009
  • Ground anchor should not be used in soft clay, because anchor resistance can not be guaranteed. However, there is a way to increase the capacity of anchors. The pulse powered anchor is an underreamed anchor by using high voltage electrokinetic pulse energy. In this study, a series of field test were carried out in order to find expansion rate related in number of pulse charge. and Anchor pull-out tests were performed at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea. Data were analyzed in order to define a relation between expansion rate and ultimate pullout load.

  • PDF

A Study on the Retention Characteristics with the Charge Injection Conditions in the Nonvolatile MNOS Memories (전하주입조건에 따른 비휘발성 MNOS 기억소자의 기억유지특성에 관한 연구)

  • Lee, Kyoung-Leun;Yi, Sang-Bae;Lee, Sang-Eun;Seo, Kwang-Yell
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1265-1267
    • /
    • 1993
  • The switching and the retention characteristics with the injection conditions(pulse height and pulse width) were investigated in the nonvolatile MNOS memories with thin oxide layer of $23{\AA}$ thick. The shift of flatband voltage was measured using the fast ramp C-V method and experimental results were analized using the previously developed models. It was shown that the experimental results were described quit well by the trap-assisted and modified Fowler-Nordheim tunneling models for the voltage pulse of $15V{\sim}19V,\;24V{\sim}25V$, respectively. However, the direct tunneling model was agreement with experimental values in all range of pulse height. As increasing the initial shift of the flatband voltage, the decay rate was increased. But for the same initial shift of the flatband voltage, the decay rate was smaller for low and long pulse than for high and short one.

  • PDF

ANALYSIS OF ER:YAG LASER IRRADIATION ON CUTTING EFFICACY AND TEMPERATURE CHANGES OF DENTIN (Er:YAG 레이저의 상아질 삭제효과 및 이에 따른 온도변화)

  • Im, Kwang-Ho;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.32-44
    • /
    • 2001
  • The purpose of this study was to investigate the effects of Er : YAG laser on cutting efficacy and temperature changes of dentin. We used the dentin specimens of human premolars and molars which contain the physiologic saline and maintain the pulpal pressure in dentinal tubules. Each specimen was exposed to Er : YAG laser with non-contact handpiece type delivery system under different treatment condition of irradiation energy, pulse repetition rate, and exposure time. Two procedures were conducted by the presence of water flow during lasing. The specimens were grouped by thickness of dentin. We investigated the cavity pattern, volume, and temperature change of dentin specimen to determine the cutting efficacy and temperature rise of Er : YAG laser, and obtained following results. 1. Cutting volume of dentin was increased by increasing the irradiation energy, pulse repetition rate, and exposure time(P<0.05). 2. Margins of abulated cavities were sharp and clean and floors of cavities were conical in shape and showing smooth surfaces. Upper diameter of abulated cavities were increasing as laser parameter of irradiation energy, pulse repetition rate, and exposure time were increased. A few cracks were observed on abulated surfaces under treatment condition of laser parameter with 150mJ, 5Hz, and 5sec. 3. Temperature was increased as laser parameter of irradiation energy, pulse repetition rate, and exposure time were increased, and temperature rise was decreased as dentin thickness was increased(P<0.05). 4. Temperature rise was decreased under water flow compared with no water flow during laser exposure(P<0.05). From these results, we think that the method of using a Er:YAG laser would be effective and safe in cutting dentin for clinical application.

  • PDF