• 제목/요약/키워드: Pulse radiation

검색결과 245건 처리시간 0.022초

Radiation detector deadtime and pile up: A review of the status of science

  • Usman, Shoaib;Patil, Amol
    • Nuclear Engineering and Technology
    • /
    • 제50권7호
    • /
    • pp.1006-1016
    • /
    • 2018
  • Since the early forties, researchers from around the world have been studying the phenomenon of deadtime in radiation detectors. Many have attempted to develop models to represent this phenomenon. Two highly idealized models; paralyzable and non-paralyzable are commonly used by most individuals involved in radiation measurements. Most put little thought about the operating conditions and applicability of these ideal models for their experimental conditions. So far, there is no general agreement on the applicability of any given model for a specific detector under specific operating conditions, let alone a universal model for all detectors and all operating conditions. Further the related problem of pile-up is often confused with the deadtime phenomenon. Much work, is needed to devise a generalized and practical solution to these related problems. Many methods have been developed to measure and compensate for the detector deadtime count loss, and many researchers have addressed deadtime and pulse pile-up. The goal of this article is to summarize the state of science of deadtime; measurement and compensation techniques as proposed by some of the most significant work on these topics and to review the deadtime correction models applicable to present day radiation detection systems.

Cross Correlated Effects of Radiation Damping and the Distant Dipolar Field with a Pulsed Field Gradient in Solution NMR

  • Chung Kee-Choo;Ahn Sang-Doo
    • 한국자기공명학회논문지
    • /
    • 제10권1호
    • /
    • pp.46-58
    • /
    • 2006
  • With a simple pulse sequence ($\pi/2$-{gradient, duration T}-acquisition) in solution NMR, detected signal has slowly grown up to percents of the equilibrium magnetization. The source of this unusual resurrection of dephased magnetization after a crushed gradient is cross-correlated effects of radiation damping and the distant dipolar field, which has been demonstrated by a numerical simulation and theoretical analysis.

  • PDF

중재적 방사선 분야 방호용구 차폐효과 (Shielding Effect of Radiation Protector for Interventional Procedure)

  • 고신관;강병삼;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권3호
    • /
    • pp.213-219
    • /
    • 2007
  • 중재적 시술의 시술자를 대상으로 방사선 방호용구의 안과 밖의 실제 방사선량을 측정하여 이를 바탕으로 방사선 방호용구의 방사선 차폐율을 비교 분석하는 것이다. 2005년 5월부터 9월까지 중재적 시술 중에서 시행 빈도가 높은 TACE, PTBD를 시행하는 중재적 시술자 4인에게 방사선 방호용구의 착용 시 피폭선량 감쇄효과를 측정하기 위해 각 신체부위별 방호용구 안과 밖에 TLD를 부착하여 피폭선량을 측정하였다. TLD 부착부위는 Goggle inside, Goggle outside, Thyroid protector inside, Thyroid protector outside, Apron inside(waist level), Apron outside(upper chest level), Hand 4th finger(ring type TLD)와 환경방사선을 측정하기 위해 TLD 10개를 Control room 여러 곳에 위치시켰다. TACE 검사시 0.07 mmPb Goggle의 사용으로 연속투시방식에서는 평균 53.8%의 선량율감쇄를 보였으며 펄스투시방식에서는 77.6%의 감쇄효과를 보였고, 0.5 mmPb Thyroid protector의 사용에서는 연속투시방식에서는 평균 88.9%의 선량율감쇄를 보였으며 펄스투시방식에서는 92.8%로 선량율감쇄에서는 유의한 차이가 없었다. PTBD 검사시 0.07 mmPb Goggle의 사용으로 평균 62.7%의 선량율감쇄를 보였으며, 0.5 mmPb Thyroid protector의 사용에서는 평균 89.1% 선량율이 감쇄 되었고 0.5 mmPb Apron의 사용에서도 평균 87.9%의 감쇄효과가 있었다. PTBD 시술은 TACE 시술에 비해 평균 투시시간은 6.14 min이나 적었으나 피폭선량은 체부에서 약 3배, 손에서는 40배 이상 피폭되었다. 납당량이 두꺼운 방호용구를 착용하거나 최소한 권고되어지는 0.5 mmPb 이상의 것을 착용하여야 하며, 시술시 눈을 보호하는 Goggle의 착용을 생활화해야 한다. 테이블 아래쪽에 납커튼을 장착하면 복부의 피폭선량율은 평균 38.4% 감쇄하므로 납커튼을 장착하여 산란선을 차폐하여야 한다. 펄스투시방식을 이용하면 연속투시에 비해 피폭선량율이 평균 59.0% 감쇄되므로 연속투시보다 펄스투시방식을 선택하여 피폭선량을 감소시켜야 한다.

  • PDF

수목(樹木)의 수분특성(水分特性)에 관(關)한 생리(生理)·생태학적(生態學的) 해석(解析)(VII) - Heat pulse법(法)에 의한 낙엽송임분(林分)의 수액류속(樹液流速) 계측(計測) - (Ecophysiological Interpretations on the Water Relations Parameters of Trees(VII) - Measurement of Water Flow by the Heat Pulse Method in a Larix leptolepis Stand -)

  • 한상섭;김선희
    • 한국산림과학회지
    • /
    • 제82권2호
    • /
    • pp.152-165
    • /
    • 1993
  • 본(本) 연구(硏究)는 heat pulse법(法)을 이용하여 낙엽송 임분(林分)의 증산량(蒸散量)을 알기 위한 기초 연구로써, 일사량(日射量), 온도(溫度), 습도(濕度) 등의 변화에 따른 heat pulse 속도(速度)의 일변화와 계절변화, 방위별 heat pulse 속도(速度)의 차이, 변재부(邊材部)에 있어서 깊이별 heat pulse 속도(速度)의 차이, 우세목(優勢木), 준우세목(準優勢木), 열세목(劣勢木)의 heat pulse 속도(速度)의 차이, 엽(葉)의 수분(水分)포텐셜과 heat pulse 속도(速度)와의 관계, 줄기에 있어 수분상승의 방향, heat pulse법(法)으로 추산한 임분(林分)의 증산량(蒸散量)등에 대하여 측정 고찰하였다. 얻어진 결과를 요약하연 다음과 같다. 1 낙엽송의 heat pulse 속도(速度)(V)와 수액유속(樹液流速)(SFR)과의 관계는 SFR=1.37V($r=0.96^{**}$)의 식으로 나타냈다. 2. 우세목(優勢木), 준우세목(準優勢木), 열세목(劣勢木)의 heat pulse 속도(速度)를 비교하면, 수액유속(樹液流速)은 우세목(優勢木)이 가장 높고, 준우세목(準優勢木), 열세목(劣勢木) 순위였다. Heat pulse 속도(速度)는 일사량(日射量), 온도(溫度), 대기포차(大氣飽差) 등의 크기에 따라 심한 변화(變化)를 나타냈다. 3. 입목(立木) 개체간(個體間)의 heat pulse 속도(速度)의 차이는 이른 아침과 밤에는 거의 없으나, 일사량(日射量)이 높은 12시부터 16시 사이에는 약간의 차이를 나타냈다. 4. Heat pulse 속도(速度)와 수분(水分)포텐셜은 거의 비슷한 일변화 경향을 나타냈다. 5. Heat pulse 속도(速度)의 계절변화는 8월에 가장 높았고, 10월이 가장 낮았다. 그리고 6, 7, 9월의 heat pulse 속도(速度)는 거의 비슷한 값을 나타냈다. 6. 줄기에 있어 방위별 heat pulse 속도(速度)는 동측이 가장 높았고, 서측과 북측은 비슷한 속도를 나타냈으며, 남측의 속도가 가장 낮았다. 7. 변재부(邊材部)에 있어서 깊이별 heat pulse 속도(速度)의 차이는 수피(樹皮)로부터 2cm 깊이에서 가장 높고, 다음이 1cm 깊이, 그리고 3cm 깊이에서 가장 낮았다. 8. 줄기에 있어 수분이동방향(水分移動方向)은 5본 모두 오른쪽 나선상승(螺旋上昇)(spiral ascent turning right)을 나타내고 있었다. 특히 지상의 3m까지는 매우 느린 회선(回旋)을 나타내다가 그 이상의 수고(樹高)에서는 매우 빠른 회선(回旋)으로 상승됨을 알 수 있었다. 9. 수액유량(樹液流量)(SF)은 SF=1.37AV 식(式)으로 나타났고, 이 식으로 구한 수액유량(樹液流量)은 우세목(優勢木)이 준우세목(準優勢木)과 열세목(劣勢木)보다 현저히 높았다. 10. 1ha의 임분(林分)에 대한 1일의 증산량(蒸散量)의 구성비율(構成比率)은 낮이 83%, 밤이 17%였고, 증산량(蒸散量)은 약 30.8ton/ha/day이었다. 11. 1ha의 월별(月別) 증산량(蒸散量)은 8월이 1,194ton/ha/month로 가장 많았고, 5월이 386ton/ha/month로 가장 낮았다. 또 1ha의 연간(年間) 증산량(蒸散量)은 3,983ton/ha/yr이었다.

  • PDF

M&S 기반 반도체소자의 펄스감마선 피해평가 시스템 구축 연구 (A Study on Implementation of a Transient Radiation Effects on Electronics(TREE) Assessment System Based on M&S)

  • 이남호;이승민
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.969-973
    • /
    • 2013
  • To simulate the effect of high dose-rate radiation on semiconductor devices, device modeling work has been performed especially in the area of photo-current generation by a PIN diode. The resultant analytical values were compared with experimental ones that were specially designed and performed to benchmark the simulation results. Initial results showed 27.85% error between the simulation and the experiment. The error can be further reduced by improvement both in simulation and in related experiments. The developed technique from the study can be applicable to radiation dosimetry and to analysis on the radiation effects in electronics.

펄스 복사 능력 개선을 위한 리플형 광대역특성을 갖는 비선형 와이어안테나 설계에 관한 연구 (A Study on the Design of Nonlinear Wire Antennas with Ripple-Type Wide Band Characteristics for Improvement of Pulse Radiation Ability)

  • 김연선;박의준
    • 대한전자공학회논문지TC
    • /
    • 제39권3호
    • /
    • pp.150-157
    • /
    • 2002
  • 펄스 안테나로 많이 사용되는 종래의 직선형 혹은 V-형 안테나의 원거리전장은 null점들을 갖는 주파수 특성을 가지므로 제한된 펄스 복사 능력을 가진다. 이를 개선시키기 위해 비선형적 형상을 갖는 와이어안테나의 합성법을 제안하였다 즉, 복사 전장의 주파수 의존성을 최소화시키는 형상방정식을 유도하고 그 해를 산출하므로서 리플형의 광대역 특성을 갖는 형상을 합성하였다. 그 결과 매우 넓은 주요 스펙트럼을 갖는 짧은 펄스의 복사에 유리함을 보였다. 따라서, 펄스폭이 좁을수록 합성된 다이폴 안테나 특성이 종래의 선형 다이폴 보다 우수한 피크치를 갖는 펄스 복사가 이루어짐을 보였다. 전류 분포 및 원거리 전장의 과도해석을 위해 모멘트법에 기반한 역 이산 푸리에 변환을 사용하였다.

광촉매와 조합된 코로나 방전 플라즈마 필터의 유해 가스 및 입자 제거 특성 (A Compact Pulse Corona Plasma System with Photocatalyst for an Air Conditioner)

  • 신수연;문재덕
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.151-155
    • /
    • 2007
  • A compact discharge plasma system with a photocatalyst has been proposed and investigated experimentally for application to air conditioners. It was found that there was intense ultra violet radiation with high energy of 3.2 eV from the corona discharge due to the DC-biased pulse voltage applied on a wire. An electrophotochemical reaction took place apparently on the surfaces of the photocatalyst of $TiO_2$ irradiated ultra violet front the discharge plasma in the proposed plasma system. The proposed discharge plasma system with the photocatalyst of $TiO_2$ showed very high removal efficiency of VOCs by tile additional electrophotochemical reactions on the photocatalyst. The proposed discharge plasma system also showed very high removal efficiency of particles such as smokes, suspended bacteria, and pollen and mite allergens by the electrostatic precipitation part. This type of corona discharge plasma system with a photocatalyst can be used as an effective means of removing both indoor pollutant gases and particles including suspended allergens.

Finite element modeling of laser ultrasonics nondestructive evaluation technique in ablation regime

  • Salman Shamsaei;Farhang Honarvar
    • Advances in Computational Design
    • /
    • 제8권3호
    • /
    • pp.219-236
    • /
    • 2023
  • In this paper, finite element modeling of the laser ultrasonics (LU) process in ablation regime is of interest. The momentum resulting from the removal of material from the specimen surface by the laser beam radiation in ablation regime is modeled as a pressure pulse. To model this pressure pulse, two equations are required: one for the spatial distribution and one for the temporal distribution of the pulse. Previous researchers have proposed various equations for the spatial and temporal distributions of the pressure pulse in different laser applications. All available equations are examined and the best combination of the temporal and spatial distributions of the pressure pulse that provides the most accurate results is identified. This combination of temporal and spatial distributions has never been used for modeling laser ultrasonics before. Then by using this new model, the effects of variations in pulse duration and laser spot radius on the shape, amplitude, and frequency spectrum of ultrasonic waves are studied. Furthermore, the LU in thermoelastic regime is simulated by this model and compared with LU in ablation regime. The interaction of ultrasonic waves with a defect is also investigated in the LU process in ablation regime. Good agreement of the results obtained from the new finite element model and available experimental data confirms the accuracy of the proposed model.

하전입자의 측정을 위한 다중선 비례계수기와 전치증폭기의 설계 제작 (Design and Construction of Multi-wire Proportional Counter and Preamplifier for Measurement of Charged Particle)

  • 김종수;윤석철
    • Journal of Radiation Protection and Research
    • /
    • 제21권2호
    • /
    • pp.139-143
    • /
    • 1996
  • 본 연구에서는 방사선/능의 측정을 위하여 감응 면적이 큰 다중선 비례계수기를 양극선의 지름과 재칠 그리고 선공간을 고려하여 설계 제작하였다. 또한 비례계수기에서 출력하는 펄스를 측정하기 위하여 검출기와 주증폭기 또는 카운터 사이에 연결하는 전치증폭기를 설계 제작하였다. 본 전치증폭기는 전하감응 미분회로, 클리핑회로 그리고 증폭회로로 구성하였다. 이들에 대한 성능시험을 위하여 $^{239}Pu(360Bq)$$^{90}Sr/^{90}Y(250Bq)$의 방사선원을 사용하여 동작전압을 결정한 다음 전치증폭기로부터의 최종 출력펄스 $V_2(t)$를 측정하여 출력펄스에 포함되어 계수시에 영향을 미치는 잡음성분과 비교하였다. 잡음성분은 8mV로 조사선원 각각에 의한 출력펄스 180mV와 200 mV 보다 상당히 작아 계수시 이에 대한 영향은 없었다. 전하감응 미분회로의 출력펄스에서 발생된 중첩펄스는 클리핑 회로와 증폭회로에서 시정수와 증폭도를 변화시키므로서 독립된 펄스로 측정하였으며, 이로 인한 측정손실을 개선할 수 있었다.

  • PDF

Resistive and Inductive Loading Techniques on Microstrip Antenna for Wideband Application

  • Jeon, Sang-Bong;Ahn, Chang-Hoi
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.693-696
    • /
    • 2011
  • In this work, an exponentially tapered microstrip antenna was implemented using a resistive loading technique in order to suppress the internal reflections. The inductive loading was realized by introducing slits on the antenna to improve radiation efficiency. Compared with a resistive-loaded antenna, the proposed antenna had an average improvement of about 6.2% in radiation efficiency within the range of 2-10.5 GHz. In addition, the highest peak of the radiated short pulse from the proposed antenna became 45% greater than that of an antenna with resistive loading only.